LT-352 INSTALLATION PROCEDURE

Large Capacity Tray

Applied Machine: Konica 7055/7065,7060/7150

I. Accessory parts III. Installation procedure


1. Using a nipper, cut out the paper feeding cover on
No. Name Shape Q’ty
the right side of the main body to make a hole.
1 Lower cover
(front) Caution:
1 • Carefully cut off the cover so that the projections
made around the hole should not exceed 1mm.
2 Lower cover • When using a nipper, be careful not to damage
(right) the guide plate inside the paper feeding cover.
1 (Damaging the guide plate may cause paper
jam.)
3 LCT installation
plate 1
Within 1mm Paper feeding cover

4 TP screw
(M5x8)
2
Within 1mm
5 TP screw
(M4x14) 4

6 SEMS II screw
(M4x6) 1

7 TP screw
(black) 4 2. Remove the lower right side cover of the main body,
(M3x6) and remove the two screws to remove the con-
nector cover.
8 TP screw
3. Using nipper, cut off the three portions illustrated
(M3x6) 1 below.

Lower right side cover


of the main body
II. Preparation Connector cover

1. Be sure to turn OFF the power switch of the main 2 screws


body before starting this operation.
2. DO NOT turn ON the power switch until all the
locking materials are removed from the LCT.

E-1 129M97071
4. Install the LCT installation plate with TP screws Caution:
(M4x14: 4pcs.). Tighten the screws in the order of • When closing the top cover with the LCT laid
q to w. down, be careful that the paper feed roller is not
caught.
• Carefully set up the LCT so as not to deform the
lower covers (front and right).
TP screw M4x14: 4 pcs. 10. Remove the two rail fixing screws (front and rear)
of the LCT.
w q

LCT installation plate

5. Take out the LCT from the packing carton with


lower cushions attached. LCT (rear) LCT (front)
6. Remove the right side plate of LCT.
7. Remove the 4 screws to remove the locking plate.
Peel off the four lock tapes and remove the two Rail fixing screw
locking pieces.
Caution:
After pushing down the two locking pieces in the 11. Remove the cord fixing plate on the right side of
direction of the locking plate, remove them. the main body by removing two TP screws
(M4x6).
Locking plate

[Right side
of the main body]

Locking piece Screws: 4 pcs.

TP screw M4x6: 2 pcs.

Cord fixing plate


Locking plate of the main body

Lock tapes: 4
Locking
piece

12. Connect the three connectors on LCT cord fixing


plate to those on the cord fixing plate of the main
body , and fix those two cord fixing plates with a
8. Reinstall the right side plate of LCT. TP screw (M3x6).
9. Install the lower covers (front and right) with black
TP screws (M3x6: 2 pcs. each)
TP screw (black) M3x6: 2 pcs.
Connectors of LCT
Cord fixing plate of the main body

TP screw M3x6
Lower cover (right)

TP screw (black) Cord of LCT


M3x6: 2 pcs.
LCT cord fixing plate

Lower cover (front)

E-2
13. Fit the cord fixing plates to the main body with IV. Adjustment
two TP screws (M4x6) removed in step 7, and fix
the earth cord with a SEMS II screw (M4x6). [Adjustment for machine inclination]
Proceed the following adjustment so that the gap be-
tween LCT and main body should be equal from the
top through the bottom, and that the LCT could be
easily locked to the main body.
[Right side of 1. Draw the LCT apart from the main body until the
the main body] height adjustment nut appears.

Cord fixing plate

TP screw M4x6: 2 pcs.

LCT

SEMS II screw M4x6


Earth cord

Height adjustment nut

14. Install the LCT to the main body with a TP screw


(M5x8) each on the two joints of the LCT, placing
the positioning screw attached to the front joint
into the hole on the frame of main body. 2. With the nut loosened, turn the caster axis by us-
Caution: ing a screwdriver to adjust the inclination in front
Tighten the screws while pressing down the joints and rear or right and left.
of the LCT. 3. Adjust also the height of front and rear casters
of the LCT so that the actuator of the LCT instal-
lation plate installed to the main body should be
inserted in the center of the LCT interlock SW
window.
TP screw M5x8
[Main body]

Actuator of the LCT installation plate


TP screw M5x8 Positioning screw
LCT interlock SW window

[LCT]

15. Reinstall the lower right side cover of the main


body.

E-3
Caution: [Adjustment for centering error]
Adjust and verify that the gap between the main 1. Turn ON the power switch while pressing Ten keys
body and LCT should fall within 5 ± 1 mm from the c and n simultaneously.
top through the bottom. 2. Select v Test pattern output mode.
3. Enter 16 using Ten keys, and touch the keys in
the order of “SET” and “Copy Screen”.
4. Select “Tray 5” and press START PRINT button to
make a sheet of copy.
5. Check if the centering error occurs. (Standard:
1mm or less)
6. When the centering error is found, follow the ad-
justment procedure described below.
<For the error over 2mm>
Open the upper cover, loosen the 8 screws illus-
trated below, and change the position of the side
guides until the error is improved.
(In this case, move the front and rear side guides
equally in the length by referring to the stamps on
the reinforcing plates (front/rear) of the side guides
4. When the adjustment is completed, tighten the nut. or on the bottom plate.)
5. Check that the LCT is securely locked to the main
Upper cover
body.

Screw: 4 pcs. Screw: 4 pcs.

<For the error less than 2mm>


1. Turn ON the power switch while pressing Ten keys
c and n simultaneously.
2. Select x Image adjustment.
3. Select b Centering adjustment.
4. Select z Centering adjustment (Front).
5. Select 400dpi .
6. Touch the arrow key and select “Tray 5”.
7. Change the data and touch the keys in the order
of “SET” and “Copy Screen”.
Range available to be entered: –32 ~ +32
1 step = 0.06mm
8. Press START PRINT button to make a sheet of
copy.
9. Check if the centering error occurs.
For readjusting the error, press C button while
pressing P button.
10. Repeat the steps 7 to 9 until the error is improved.

E-4