I. Objective
This report covers the student’s first technical inspection report to a steam power
plant with steam engine
II. Theory and Analysis
III. Procedure
Make a physical study and layout of the Steam Power Plant TH-3134 based on American Society of
Mechanical Engineers (ASME) and Philippine Society of Mechanical Engineers (PSME) test codes. Include
the following:

General Instructions

1. Steam-piping Layout. Starting with the shut-off valve on the boiler, sketch the high pressure piping to
to each of the steam engine. Indicate the location of each valve and fitting. Give the type and purpose of
each and the reason for its particular location. Show the steam separators and steam traps.

2. Exhaust steam, Condensate, and Feedwater Piping. In a second sketch, indicate the path of exhaust
steam, of the condensate. Observe the general outline given for the previous sketch and, in addition,
indicate the following: source of make-up or raw water supply and where it gets to be admitted into the
system, how it is controlled and measured.

3. Main Units. A description of the steam boiler and steam engine units should be given.

a. Steam Boiler - Manufacturer's name, model, serial number, type, heating surface, steam output, fuel
consumption, power consumption, approximate shipping weight, operating pressure and load, method
of measuring output and rating, automatic and safety controls.

b. Steam Turbine - Manufacturer's name, model, size, power rating, normal running speed, emergency
trip speed, maximum pressure, classification (condensing or non-condensing), kind of load, blade
dimension, method of lubrication, safety controls and procedure in starting, running and shutdown.

auxiliaries should be included in the report.

4. Auxiliaries. A brief description of the type, size and conditions of operation of each of the major
auxiliaries should be included in the report.

a. Condenser (surface or jet) - Manufacturer's name, overall dimensions, condenser tube specification
(number of tube, Inside diameter and outside diameter), number of pass; size of steam, water and air
connection; pressure and temperature at the time of observation. and source of circulating water.

b. Condenser Pump - Wet or dry air pumps, condensate pumps and circulating water pumps should be
described.

C. Feed water System

Heaters (open or closed) - Method of piping, treatment of feedwater and pressure and temperature at
the time of observation.

Pumps - Type, size and speed.

Control Type and method of operation of feedwater regulators and pump - governors.
d. Other auxiliaries - Note the type and location of each of the following, if they are provided:
superheaters, economizers, forced draft fans, induced-draft fans, soot blowers, carbon dioxide
recorders, oil purifiers and air compressors.