Searchring Name: BRGY. RIZAL, BUENAVISTA, GUIMARAS
Site ID: IVS1002 – OPTION A – JULIAN GUMARIN
Site Address: Brgy. Rizal, Buenavista, Guimaras
02-03-2022
2/2/2022
Name __________________________
Calixter John Advincula APPROVED DOCUMENT
AGILE VIS NSB - TRANSPORT
Designation______________________ APPROVED SOLUTION
REJECTED
Additional Remarks:
RF Details: MW Assessment:
CORRECT SR Name: BrgyRizal_Buenavista_Guimaras ACL: 35m, 35m (JMBASA)
S1: Brgy Rizal AZIMUTH: 276.24, 96.23
S2: Brgy Sto Rosario ANTENNA SIZE: 1.2m
S3: Brgy Rizal MW TYPE: 1G
S4: MacArthurs Wharf and Ferry Terminal Remarks: With LOS based on table top assessment.
Azimuth: 80/140/220/280
Antenna: 16-Port Rosenberger
BTS Type: Indoor
Tower Height: 40m for ATC (SST)
Proposed Tech: G9*|L9*+L7*|G18|L18+L21|L23|L26MM
(TBD once final CLP is available)
ACL: 38m FOC not Doable, site is on island, no existing FOC facility in the area, Recommended for MW solution.
MDT: 2/2/2/2
PUBLIC
For Public Use
Table of Contents
NEW SITE
IVS1002 – OPTION A – JULIAN GUMARIN
A. GENERAL INFORMATION
Note: Provide all photos necessary for the site completion, if such photo item mentioned above
is not applicable then just put remark as” NA"
PUBLIC
For Public Use
Survey Team
A. GENERAL INFORMATION
Longitude: 122.6172
Latitude: 10.6878517
PUBLIC
For Public Use
A2. Vicinity Map
PUBLIC
For Public Use
B. SITE SURVEY REPORT
A. Distance from shoreline: 42 m
B. Type and Height of Structure: GBT‐SST/ 30m
C. Type of Attachment /Anchorage
15 15
C1. Topographic Condition of the Site
C2. If the site is Rolling or Mountains, does it require?
C3. Is the site located in one of the following conditions?
Swamp or Pond Rocky Ground Others: Used land/clay
Dense Forest Reclaimed Land
Additional Findings:
N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A
N/A
N/A
PUBLIC
N/A
For Public Use
D. Type of Radio Room ‐ N/A
N/A N/A
N/A N/A
N/A N/A
E. Accessibility to Site
0.3 m high
F. Commercial Power availability
Greenfield Site:
Secondary Power Line
Length of tapping point from (Service Entrance to existing pole) : 20.77m
(From existing pole to existing transformer) : 78.12m
Primary Power Line
Distance of primary line (from existing transformer to primary line): N/A
Estimated no. of poles at ______m pole to pole : N/A
Commercial AC to power supplied by Electric Company/Cooperative: GUIMELCO
PUBLIC
For Public Use
Ground Base Tower Sites:
Approval of lessor of the proposed location of meter of submeter (NA)
Check the availability of required loads with building owner (NA)
Avail temporary power supply during constructions and during On‐air site of Site until permanent power is available
(Yes. To apply for temporary power)
(to provide conceptual drawing of AC Commercial Tapping point) – To be included on conceptual drawing.
Temporary Power Source:
G. Earthing System (for Rooftop sites)
N/A N/A
Negotiate with Building owner the proposed location where to drive ground rod and test pit. (NA)
Discuss with the Building owner the possible grounding and cable route and get approval (NA)
N/A N/A
Discuss with building owner the possible earthing cable route and get approval
Check the tapping point and the terminal lug to be used
Check if there are obstructions along the proposed cable route
H. Drainage System (for greenfield only)
Provide possible location on conceptual drawing (drainage will not reflect on CD)
I. Obstruction during erection
Discuss with building owner the possible earthing cable route and get approval (NA)
Check the tapping point and the terminal lug to be used (NA)
Check if there are obstructions along the proposed cable route (No Obstructions).
PUBLIC
For Public Use
J. Flood History (as acquired by lessor and/or neighbors)
According to Lessor & Resident there is no history for flooded (with respect to road and proposed site)
K. Lot elevation from fronting road (approx.) (+) 0.3 m / (‐) ____m
L. Soil condition Report (to be secured from engineering office, if not available subsoil exploration
to be conducted as may require by client)
M. Usage of proposed Location
N. Existing Ordinance
PUBLIC
For Public Use
O. Variation Works:
Temporary access road, Temporary facilities, temporary safety fence and cutting of trees.
P. Peace and Order Situation, History:
Area is relatively peaceful.
Q. Mode of Transportation going to proposed site, in detail (starting from main road/town)
All heavy equipment and any type of vehicle can access the area
R. Remarks and Narrative Report:
As per our site validation the residents of this area are willing to install cell site tower in order
to provide good communication. The road right of way is owned by the lessor, which is 5
meters in width and 21 meters in length.
PUBLIC
For Public Use
B2. Proposed Site Layout & ROW Details
Proposed Site
15mx15m
ROW 5m width,
21m in length
PUBLIC
For Public Use
B3. Proposed Location and Distance to Nominal Point
PUBLIC
For Public Use
B4. Proposed Lot Perimeter Layout
PUBLIC
For Public Use
B5. Coordinates (Proposed Site Coordinates & Fronting Road Coordinates)
PUBLIC
For Public Use
B6. Access Road (ROW, Barangay Road & Main Road)
Access Road to Site
Entrance to Site
PUBLIC
For Public Use
B7. Panoramic Pictures
0° 30°
60° 90°
120° 150°
PUBLIC
For Public Use
180° 210°
240° 270°
300° 330°
PUBLIC
For Public Use
B8. Coverage Objectives (Sector 1 to Sector 3)
80°
30° - SECTOR 1
140°
230° - SECTOR 2
PUBLIC
For Public Use
220°
290° - SECTOR 3
280° - Sector 4
PUBLIC
For Public Use
B9. Nearest Tapping Point & Cable Routing from Power Source to Site (78.12 m to Site)
Transformer to Proposed Site
Proposed Site
PUBLIC
For Public Use