Lighting Design - BIAL Cabin - Victor Uni

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Object :

Installation : BIAL Office, Bangalore


Project number : BIAL Cabin - Trial 01
Date : 19.11.2022

1 Cabin 01
1.1 Summary, Cabin 01
1.1.1 Result overview, Evaluation area 1

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 x [m]

0 100 150 200 300 500 750 1000


Illuminance [lx]

General
Calculation algorithm used Average indirect fraction
Height of luminaire plane 2.70 m
Maintenance factor 0.80

Total luminous flux 4840.00 lm


Total power 44.0 W
Total power per area (16.00 m²) 2.75 W/m² (2.66 W/m²/100lx)

Evaluation area 1 Reference plane 1.1


Horizontal cylindrical
Em 103 lx 63 lx
Emin 40 lx 35 lx
Emin/Em (Uo) 0.39 0.55
Emin/Emax (Ud) 0.23
Ec/Eh 0.51
Position 0.75 m 1.20 m
UGR (2.8H 2.8H) <=25.9
Luminaire :
(Victor Uni (22+22W) (! 1x44W) (1))

Major surfaces Em Uo
M 1.5 (Ceiling) 71.2 lx 0.30
M 1.1 (Wall) 92 lx 0.34
M 1.2 (Wall) 82.1 lx 0.35
M 1.3 (Wall) 90.9 lx 0.34
M 1.4 (Wall) 60.7 lx 0.68

-please put your own address here-


Relux1 Page 1/2
Object :
Installation : BIAL Office, Bangalore
Project number : BIAL Cabin - Trial 01
Date : 19.11.2022

1 Cabin 01
1.1 Summary, Cabin 01
1.1.1 Result overview, Evaluation area 1

Type No.\Make

REGENT
1 1x Order No. :!
Luminaire name : Victor Uni (22+22W)
Equipment : 1 x LED 4000K 44 W / 4840 lm

-please put your own address here-


Relux1 Page 2/2