2. PLUMBING CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER CONTRACTORS CD CONDENSATE DRAINAGE
INVOLVED IN THE PROJECT. NUMBER OF DETAIL ON SHEET CWR CONDENSER WATER RETURN
3. PLUMBING BIDDERS SHALL VISIT THE JOB SITE TO LOCATE WATER AND SANITARY PIPING TIE- NUMBER OF SHEET WHERE DETAIL APPEARS
IN POINTS. CWS CONDENSER WATER SUPPLY
4. INSULATION:
A. SEE INSULATION SPECIFICATION SECTION IN THE PROJECT MANUAL OR ON THE 1 KEYNOTE HWR HEATING WATER RETURN
2' - 0"
DRAWINGS FOR INSULATION THICKNESS AND REQUIREMENTS. HWS HEATING WATER SUPPLY
B. HANDICAPPED SINK AND LAVATORY WASTE PIPING AND WATER SUPPLY PIPING SHALL BE CONTINUATION SYMBOL
INSULATED TO COMPLY WITH THE ILLINOIS ACCESSIBILITY CODE AND THE AMERICANS Room G NATURAL GAS
WITH DISABILITIES ACT USING PREFABRICATED INSULATION. 1
5. PLUMBING FIXTURES, EQUIPMENT AND DRAINS: ROOM NAME AND NUMBER PG PROPANE GAS
A. FURNISH AND INSTALL PLUMBING FIXTURES AND DRAINS SCHEDULED COMPLETE WITH REF-L REFRIGERANT-LIQUID
APPROPRIATE TRAPS, CARRIERS, WASTE FITTINGS, AND LOCAL STOPS.
1' - 0"
B. MANUFACTURERS LISTED ARE AN INDICATION OF THE QUALITY EXPECTED. EQUIVALENT ITEM TO BE DEMOLISHED REF-S REFRIGERANT-SUCTION
PRODUCTS FROM OTHER MANUFACTURERS MAY BE SUBMITTED FOR REVIEW.
6. PLUMBING DOMESTIC WATER SYSTEM AND SANITARY SYSTEM SHALL NOT HAVE DEAD ENDS. REF-HG REFRIGERANT-HOT GAS
AREA NOT IN CONTRACT
A. DOMESTIC WATER SYSTEM SHALL COMPLY WITH 890-1200C. STM STEAM
B. SANITARY SYSTEM SHALL COMPLY WITH 890-1320D.
1" = 1' - 0"
7. THE VERTICAL DEFLECTION OF PVC PIPE SHALL NOT EXCEED 5%. NO DEFLECTION IS 2" PIPE SIZE TAG (DIAMETER) CDR CONDENSATE RETURN
PERMITTED FOR IRON PIPE. ABOVE GROUND PIPING
0' - 0"
AUTHORITIES HAVING JURISDICTION, AND THIS SPECIFICATION. PIPING BEING DEMOLISHED F-CW FILTERED COLD WATER
2. THE WORK SHALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, HOISTING AND RIGGING,
SCAFFOLDING, LOADING AND UNLOADING, CLEAN-UP OF DEBRIS AND OTHER SERVICES, RO REVERSE OSMOSIS WATER
TO PROVIDE THE OWNER WITH FULLY OPERATIONAL SYSTEMS.
ABBREVIATIONS
HW HOT WATER
3. ALL WORK SHALL BE PROPERLY COORDINATED WITH THE WORK OF OTHER TRADES TO
AVOID CONFLICTS. REFER TO THE ARCHITECTURAL AND STRUCTURAL DRAWINGS ONLY Ø ROUND LVR LOUVER
HW 140° HOT WATER 140°
ABV ABOVE LWT LEAVING WATER TEMPERATURE
4' - 0"
EXTRA LABOR, MATERIALS AND EQUIPMENT, REQUIRED BECAUSE OF ADDITIONAL AP ACCESS PANEL MFR MANUFACTURER
ARCH ARCHITECT/ARCHITECTURAL MIN MINIMUM IW INDIRECT WASTE
DIFFICULTIES ENCOUNTERED, WHICH COULD HAVE BEEN FORESEEN HAD SUCH AN
EXAMINATION BEEN MADE. BFF BELOW FINISHED FLOOR MISC MISCELLANEOUS OV OIL VENT
5. ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BLW BELOW MTR MOTOR
1/2" = 1' - 0"
FROM DATE OF FINAL ACCEPTANCE OF THIS WORK. ENGAGE THE SERVICES OF VARIOUS BTU BRITISH THERMAL UNITS MU/A MAKE-UP/AIR OW OIL WASTE
MANUFACTURER'S SUPPLYING THE EQUIPMENT FOR THE PROPER START-UP BTUH BRITISH THERMAL UNITS PER HOUR NC NOISE CRITERIA
PD PUMP DISCHARGE
ADJUSTMENT AND OPERATION OF THE EQUIPMENT, AND INSTRUCT THE OWNER'S CAP CAPACITY NC NORMALLY CLOSED
0' - 0"
PERSONNEL IN THE PROPER OPERATION AND MAINTENANCE OF THE PLUMBING SYSTEMS. CB CATCH BASIN NIC NOT IN CONTRACT V SANITARY VENT
6. PROVIDE SPARE PARTS: SPARE PARTS SHALL BE PROVIDED PER SPECIFICATION OR NO CFM CUBIC FEET PER MINUTE NO NUMBER
LESS THAN 5% OF INSTALLED AMOUNT OR ONE OF EACH. CLG CEILING NO NORMALLY OPEN SAN SANITARY SEWER
7. THIS CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS AND APPROVALS AND CO CLEAN OUT NTS NOT TO SCALE SHWR SOLAR HOT WATER RETURN
TRANSMIT ORIGINALS TO THE OWNER FOR RECORD. CONTRACTOR SHALL BE CW COLD WATER O OXYGEN
RESPONSIBLE FOR ALL FEES. D DEGREE O/A OUTSIDE AIR SHWS SOLAR HOT WATER SUPPLY
8. SUBMIT PDFS OF THE PLUMBING INSTALLATION SHOP DRAWINGS, CERTIFIED BY ALL DB DRY BULB ORD OVERFLOW ROOF DRAIN
TRADES THAT COORDINATION HAS BEEN ESTABLISHED. SUBMIT PLUMBING FIXTURE CUTS DIA DIAMETER PD PRESSURE DROP SD STORM DRAINAGE
12' - 0"
WITH TRIM, INSULATION, PIPE MATERIALS, FITTINGS, VALVES AND CERTIFIED EQUIPMENT DN DOWN PIV POST INDICATOR VALVE OSD OVERFLOW STORM DRAINAGE
CUTS WITH CONSTRUCTION WIRING DIAGRAMS. SUBMIT PDFS OF OPERATING AND DW DISTILLED WATER PLBG PLUMBING
SERVICE MANUALS WHICH SHALL INCLUDE COPIES OF ALL SHOP DRAWINGS, FIXTURE AND EA EACH PRESS PRESSURE
EQUIPMENT CUTS, SERVICE INSTRUCTIONS. PIPE DROP 4" 4" 2"
EAT ENTERING AIR TEMPERATURE PRV PRESSURE REDUCING VALVE
9. CONVECTION OVENS AND STEAM EQUIPMENT SHALL HAVE THE APPROVED DUAL CHECK ELEC ELECTRICAL PSI POUNDS PER SQUARE INCH PIPE RISE
VALVE ASSEMBLY INSTALLED ON THE WATER SUPPLY LINE. SECTION 890.1130 (F). PLUG
EQUIP EQUIPMENT PSIG POUNDS PER SQUARE INCH GAUGE PIPE TEE
8' - 0"
10. AN APPROVED REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTER DEVICE SHALL EWC ELECTRIC WATER COOLER PWR POWER 4" REDUCING 45
BE INSTALLED IN THE POTABLE WATER SUPPLY TO EACH LOCATION WHERE SANITIZING EWT ENTERING WATER TEMPERATURE R DUCT RISER CAP DEGREE TEE
CHEMICALS OR DETERGENTS WILL BE ASPIRATED OR PUSHED BY WATER PRESSURE INTO E/A EXHAUST AIR R/A RETURN AIR 45 DEGREE TEE
CLEANSING/SANITIZING OPERATION. SPILL PROOF OR PRESSURE VACUUM BREAKERS ARE EXIST EXISTING RCP RADIANT CEILING PANEL
PROHIBITED AS PER 2004 ILLINOIS PLUMBING CODE SECTION 890.1130 (F) AND IEPA. F DEGREES FAHRENHEIT RD ROOF DRAIN PIPE ACCESSORY TAGS
11. CARBONATED BEVERAGE DISPENSER SHALL HAVE AN ASSE 1022 OR ASSE 1032 (WITH FCO FLOOR CLEAN OUT REC RECESSED 2" DOM. WM 2" M-CNTRL
PORT) DEVICE IN LINE AND THE DOUBLE CHECK DEVICE SHALL BE CONSTRUCTED OF FD FLOOR DRAIN RED REDUCER DOMESTIC WATER METER MOTORIZED CONTROL VALVE
4' - 0"
STAINLESS STEEL MATERIALS. SECTION 890.1130 (F). FD FIRE DAMPER RH RELATIVE HUMIDITY
12. DEAD ENDS SHALL BE AVOIDED IN DRAINAGE SYSTEM, EXCEPT WHERE NECESSARY TO FDV FIRE DEPARTMENT VALVE RL/A RELIEF AIR 2" BALANCING 2" 3-WAY CNTRL
EXTEND THE SYSTEM TO INSTALL A CLEANOUT IN AN ACCESSIBLE LOCATION. THE DEAD FL FLOOR RM ROOM BALANCING VALVE 3 WAY MOTORIZED CONTROL
ENDS INTENDED FOR FUTURE CONNECTION OR CREATED BY REMOVAL OR
1/4" = 1' - 0"
FOS FUEL OIL SUPPLY S/A SUPPLY AIR 2" CHECK 3/8" SOLENOID
(D). CHECK VALVE REFRIGERANT SOLENOID VALVE
FPM FEET PER MINUTE SAN SANITARY
13. WATER DISTRIBUTION PIPE THAT HAS BEEN TERMINATED OR IS AN UNUSED SEGMENT
FS FLOOR SINK SF SQUARE FOOT 2" TMV 2" BUTTERFLY
SHALL HAVE NO DEAD ENDS. NO SEGMENT OF PIPE WITH A DEVELOPED LENGTH OF MORE
FT FOOT/FEET SD SMOKE DAMPER 3-WAY MIXING VALVE BUTTERFLY VALVE
THAN TWO (2'-0") FEET SHALL BE PERMITTED. SECTION 890.1190 (C)
FTR FIN TUBE RADIATION SM SURFACE MOUNT
14. IN LIEU OF AIR CHAMBERS PROVIDE WATER HAMMER ARRESTORS PER OSHA DRAIN TAGS
GAL GALLON SP STANDPIPE
REQUIREMENTS.
GC GENERAL CONTRACTOR SP STATIC PRESSURE DRAIN SIZE
GPM GALLONS PER MINUTE STM STEAM
24' - 0"
FLOOR DRAIN 4" FD-1 TYPE (SEE SCHEDULE) 4" AD-6 AREA DRAIN
GW GREASE WASTE T THERMOSTAT
HB HOSE BIB TD TEMPERATURE DROP FLOOR DRAIN 4" FD-3P "P" - INDICATES
HP HORSE POWER TDR TRENCH DRAIN 4" SD-29 DECK DRAIN
PRIMER CONNECTION
HTG HEATING TEMP TEMPERATURE
FLOOR SINK 4" FS-4 FLOW CONTROL
HTR HEATER TYP TYPICAL 4" SD-12
DRAIN
HW HOT WATER UG UNDERGROUND 4" FD-13
16' - 0"
HYD HYDRANT VAC VACUUM HUB DRAIN 4" SD-15 STORM DRAIN
8 WFU FIXTURE UNITS
ID INDIRECT V VENT
IN INCH VAV VARIABLE AIR VOLUME
INV INVERT VENT VENTILATION ROOF AREA 6" RD-1 COMBINATION
LB POUND VTR VENT THROUGH ROOF SERVED BY DRAIN 4000 SF DRAINS
LB/HR POUNDS PER HOUR W WASTE PLUMBING FIXTURE TAGS
LAT LEAVING AIR TEMPERATURE WB WET BULB TYPE (SEE SCHEDULE) L-1A
8' - 0"
WATER CLOSET -
WALL HUNG - ADA WC-1A WC-1 1 WFU
PLUMBING SHEET INDEX U-1
0' - 0"
PIPE
Sheet No. Sheet Name ACCESSORY
P-000 PLUMBING TITLE SHEET TAG
4" WCO 4" WCO
P-100 UNDERGROUND PLUMBING PLAN
P-101 100 LEVEL PLUMBING PLAN
P-102 200 LEVEL PLUMBING PLAN EQUIPMENT ABBREVIATIONS
P-103 ROOF PLUMBING PLAN
48' - 0"
P-901 SANITARY WASTE & VENT RISER DIAGRAM CT COOLING TOWER HRU HEAT RECOVERY UNIT
P-902 SANITARY WASTE & VENT RISER DIAGRAM CUH CABINET UNIT HEATER PRV POWER ROOF VENTILATOR
P-903 DOMESTIC RISER DIAGRAM CWP CONDENSER WATER PUMP RE RETURN/EXHAUST FAN
P-904 DOMESTIC RISER DIAGRAM CHWP CHILLED WATER PUMP RTU ROOFTOP UNIT
P-905 STORM RISER DIAGRAM DBP DOMESTIC WATER BOOSTER PUMP SEP SEWAGE EJECTOR PUMP
DC DUCT MOUNTED COIL SF SUPPLY FAN
16' - 0"
* NOTE *
ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN
0' - 0"
THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT
BE USED IN THIS SET OF DRAWINGS.
120' - 0"
90' - 0"
60' - 0"
3 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 2 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
1
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
18
A A.5 A.8 B C D E PLUMBING KEYNOTES
0' - 0"
14
KEY
VALUE KEYNOTE TEXT
3 1 2" SANITARY UP THRU FLOOR.
5
2 2" SANITARY UP TO SINK.
8" SD
3 4" SANITARY UP TO FLOOR CLEANOUT.
1 7 1
3' - 0"
WIC OFFICE
10 4" SANITARY UP TO PLUMBING CHASE.
108
11 INCOMING 3" DOMESTIC WATER SERVICE ENTRY. 3" DOMESTIC WATER SERVICE, INCLUDING WATER
1/8" / 1'-0" METER, ASSOCIATED STRAINER AND GATE VALVES IS INSTALLED UPSTREAM IN CIVIL "HOT BOX" HEATED
4" SAN
6" SD ENCLOSURE. WATER METER SHALL BE SIZED PER WATER DEPARTMENT SIZING REQUIREMENTS. "HOT
1 1 1 1 15 BOX" IS PROVIDED AND INSTALLED BY CIVIL CONTRACTOR. REFER AND COORDINATE WITH CIVIL
1.5 1.5 DRAWINGS.
STAIR #1
1' - 0"
107 ELEVATOR 6" SAN 6" SAN 19 15 ELEVATOR SUMP PUMP DISCHARGE UP. PROVIDE CHECK VALVE AND BALL VALVE ON RISE. ROUTE PUMP
109 105
P101 DISCHARGE TO NEAREST DRAIN RECEPTOR UNDER SINK AS INDICATED. PROVIDE AIR GAP.
0' - 0"
16
16 3" SANITARY UP TO HUB DRAIN SERVING ELEVATOR SUMP PUMP DISCHARGE.
3 1 3 17 4" SANITARY UP THRU FLOOR SERVING WATER CLOSET.
1.8 1.8
18 8" UG-STORM TO SEWER. REFER TO CIVIL DRAWINGS.
3 4" SAN 19 6" UG-SANITARY TO SEWER. REFER TO CIVIL DRAWINGS.
2 2
EDUCATION ROOM
114 VESTIBULE
100
1/8" / 1'-0"
FINANCIAL
4" SAN
4' - 0"
11
2.5 2.5
2' - 0"
MECH
119 1/8" / 1'-0"
3 4" SAN 4" SAN 4" SAN
1/2" = 1' - 0"
CLINIC GENERAL
PUBLIC CORRIDOR
WAITING
TOILET-W 100A
8 1 TOILET-M 100D
A.3 118 117
0' - 0"
JC
7
120 8 10
8
1 1
3 3
8 9 8
12' - 0"
ELEC 1
4" SAN
119A 10
4" SAN EXAM
IT ROOM EXAM EXAM EXAM
121 126 129 130 131
EXAM ISOLATION ROOM
127 128 6
BLOOD LAB
8' - 0"
122 2 6" SD
3.3 3 3.3
2
1/8" / 1'-0"
3 4" SAN 4" SAN
4' - 0"
SOILED UTILITY
4" SAN
17 124 NURSES / MA
2 141A
8
1/4" = 1' - 0"
8
8 10
TREATMENT BARIATRIC EXAM
17
125 132
0' - 0"
DOCTORS
141C
4" SAN
TOILET TOILET 1/8" / 1'-0"
13 STERIL. ROOM 2 MEDICINE
145A 123 4" SAN
144 141 1/8" / 1'-0"
2 4" SAN C.5
14 6" SD 1
4 7 4
24' - 0"
1/8" / 1'-0"
ULTRASOUND EXAM 2 EXAM 7
CLEAN UTILITY
4" SAN
145 3 2 140 NURSES / MA 133
143 141B
6" SD
6" SD
6 SUPPORT
EXAM CORRIDOR
16' - 0"
CORRIDOR
163 1/8" / 1'-0" 101B
6" SD
STAIR #2
S102 15
8' - 0"
FREIGHT
ELEVATOR EXAM EXAM EXAM
EXAM EXAM
VESTIBULE F101 BULK STORAGE EXAM 136 135 134
138 137
101 142 139
1/8" = 1' - 0"
3 1 1
5 5
8" SD
5
1
48' - 0"
18
3 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 2 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
1
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
A.5 A.8 B C D E
0' - 3"
3" = 1' - 0"
A PLUMBING KEYNOTES
0' - 0"
KEY
VALUE KEYNOTE TEXT
8" GCO 27
1 3" SANITARY UP TO FLOOR DRAIN WITH 2" VENT UP.
25 25 25 25 25 25
2 3" LAB WASTE UP TO FLOOR SINK WITH 2" VENT UP.
26 3 2" SANITARY UP THRU FLOOR.
1 1" CW 1
3' - 0"
4 2" TRAPPED AND VENTED SANITARY UP THRU FLOOR SERVING DENTAL CHAIR.
3/4" F-CW 1" F-CW 3/4" F-CW 3/4" F-CW 7 5 2" SANITARY UP, 2" VENT UP, 3/4" COLD WATER UP AND 3/4" HOT WATER PIPING UP TO ISLAND SINK.
1" RPZ
2"
3 BREAK AREA 4 WIC OFFICE 4 4 4 4 6 (2) 2" VENT UP, 3/4" COLD WATER UP AND 3/4" HOT WATER PIPING UP THRU FLOOR.
S
6" SD
AN
111 110 S-1
24 WIC OFFICE 7 (2) 2" VENT DROP, 2" SANITARY DOWN THRU FLOOR SERVING SINK. 2" VENT DOWN THRU FLOOR. PROVIDE
WIC OFFICE WIC OFFICE N. RIVERA OFFICE TRIAGE TRAPPED AND VENTED FUNNEL DRAIN UNDER SINK. PROVIDE INDIVIDUALLY VALVED 3/4" COLD WATER AND
108
2" S
5 106 104 103 102 1" CW 3/4" HOT WATER DROPS.
3 5 5
A
5 2" V
2' - 0"
3/4" HW
N
S-2 4" FCO 8 2" VENT DROP, 2" SANITARY DOWN THRU FLOOR SERVING SINK. 2" VENT DOWN THRU FLOOR. PROVIDE
1" CW 6 3/4" HW-R INDIVIDUALLY VALVED 3/4" COLD WATER AND 3/4" HOT WATER DROPS.
GT-1
6" SD
2" V
3/4" HW 9 2" VENT DROP, 2" SANITARY DOWN THRU FLOOR SERVING SINK. PROVIDE INDIVIDUALLY VALVED 3/4" COLD
2" SAN
2" V
3" V
2" V
2" V
2" V
2" V
2" V
3/4" HW-R WATER AND 3/4" HOT WATER DROPS.
6" FCO
10 2" VENT DROP, 2" SANITARY DOWN THRU FLOOR SERVING BACK TO BACK SINKS. PROVIDE (2) SETS OF
INDIVIDUALLY VALVED 3/4" COLD WATER AND 3/4" HOT WATER DROPS.
1.5 31 1.5
1' - 0"
2" PD 11 2" VENT DROP SERVING CLINICAL SERVICE SINK. 4" SANITARY DOWN THRU FLOOR. (2) 2" VENT DOWN THRU
32 FLOOR SERVING FLOOR DRAINS. PROVIDE INDIVIDUALLY VALVED 1-1/2" COLD WATER AND 3/4" HOT WATER
3/4" CW
MOTHER'S ROOM 2
6 105 DROPS.
33 3/4" HW 12 2" VENT DROP SERVING WATER CLOSET. 4" SANITARY DOWN THRU FLOOR. 1-1/2" COLD WATER DROP.
1" = 1' - 0"
6 6 4" FCO STAIR #1 13 3/4" COLD WATER DROP, 3/4" HOT WATER DROP TO LAVATORY. 2" VENT DROP, 2" SANITARY OFFSET TO
WC-2A WIC INTERVIEW PASSENGER ELEVATOR
WIC SHARED OFFICE S101 SANITARY RISER IN WALL AS INDICATED.
L-2A 6" FCO
109 P101
0' - 0"
2" SAN
4" FD-1
15 4" SANITARY UP TO WATER CLOSET, WITH 2" VENT UP.
1.8 8 1.8 16 6" STORM UP THRU FLOOR.
3/4" CW 17 6" STORM DOWN THRU FLOOR.
SOCIAL WORKER NFWH-1 18 ELEVATOR SUMP PUMP DISCHARGE UP. PROVIDE CHECK VALVE AND BALL VALVE ON RISE. ROUTE PUMP
1 1/2" CW 113 4" FCO 29 4" FCO DISCHARGE TO NEAREST DRAIN RECEPTOR UNDER SINK AS INDICATED. PROVIDE AIR GAP.
3/4" HW 3 WIC OFFICE 19 6" STORM UP.
6' - 0"
2" SAN
100B 21 2" SANITARY DOWN THRU FLOOR.
EDUCATION ROOM
22 3" SANITARY UP TO JANITOR'S MOP BASIN WITH 2" VENT UP.
2" V
114 VESTIBULE
1 100 23 2" VENT UP.
24 1" FILTERED WATER UP THRU FLOOR TO WATER FILTER.
23
4' - 0"
S-1 8 25 3/4" FILTERED WATER UP THRU FLOOR SERVING DENTAL CHAIR. FIELD VERIFY AND COORDINATE WITH
FINANCIAL COUNSEL 3 DENTAL EQUIPMENT CONTRACTOR.
2" SAN
3" V 22
115 26 1" COLD WATER DROP SERVING 1" REDUCED PRESSURE ZONE BACKFLOW PREVENTER (RPZ). DRAIN
1
ADMIN ASSISTANT DISCHARGE OUTLET INDIRECTLY TO OVER FUNNEL DRAIN. PROVIDE AIR GAP. EXTEND 1" COLD WATER TO
116 EXTERIOR GROUND YARD HYDRANT.
27 1" COLD WATER DOWN THRU FLOOR. EXTEND AND CONNECT TO EXTERIOR GROUND YARD HYDRANT.
4" SAN
MECH
2.5 3/4" HW-R 2.5
2' - 0"
119 28 3/4" COLD WATER DROP, 3/4" HOT WATER DROP SERVING MOP BASIN.
1 1/2" HW
1 29 2" SUMP PUMP DISCHARGE DROP. ROUTE TO OVER UTILITY BOX STANDPIPE DRAIN IN PLUMBING CHASE.
3" V
21 2 1/2" CW
P-401 PROVIDE AIR GAP.
PUBLIC CORRIDOR 30 2" COLD WATER, 1-1/2" HOT WATER AND 3/4" HOT WATER RISERS UP THRU FLOOR.
1/2" = 1' - 0"
100A 31 2" SANITARY FROM SINK AND 2" VENT DROP TO GREASE TRAP. 2" GREASE TRAP SANITARY OUTLET TO BE
TOILET-M CLINIC GENERAL WAITING PIPED IN WALL AND DOWN THRU FLOOR. PROVIDE INDIVIDUALLY VALVED 3/4" COLD WATER AND 3/4" HOT
A.3 TOILET-W
117 WATER DROPS.
0' - 0"
1 118 1 100D
JC 32 2" SANITARY DROP, 4" SANITARY DOWN THRU FLOOR, 2" VENT DROP SERVING WATER CLOSET AND
L-1 19
WC-1A WC-1A SANITARY RISER. 1-1/4" COLD WATER DROP.
120 L-1A
30 20 33 2" VENT DROP SERVING LAVATORY. 2" SANITARY DOWN THRU FLOOR. 3/4" COLD WATER AND 3/4" HOT
12 12 9 10 WATER DROPS.
13 13
34 PLUMBING CONTRACTOR SHALL PROVIDE SOLENOID VALVES SERVING PLUMBING FIXTURES IN TOILET
3 3 ROOM 123. FIXTURES SHALL SHUT OFF UPON SWITCH ACTIVATION. COORDINATE SWITCH LOCATION WITH
MB-1 ELECTRICAL CONTRACTOR.
12' - 0"
1" CW
28 1" RPZ S-1
ELEC 1 1/2" HW S-1 S-1
BLOOD LAB S-1 S-1
119A 2" CW
3" V
122 10 9
3 16 6" FCO
1
IT ROOM EXAM EXAM ISOLATION ROOM EXAM EXAM EXAM
8' - 0"
15
121 126 127 128 129 130 131
3.3 4" FCO 3.3
4" FCO S-1 8
8 S-1
3/4" HW-R 3/4" HW-R 3/4" HW-R
1" HW 3/4" HW 3/4" HW
4' - 0"
TOILET 14 TOILET
145A 1" CW SOILED UTILITY 3/4" CW 3/4" CW
123 BARIATRIC EXAM
13 124 8
WC-2A 4" FD-1 S-1 NURSES / MA 132
12 EXAM CORRIDOR
1/4" = 1' - 0"
2 1/2" V
4" FD-1 11 CSS-1 S-1 TREATMENT 141A
101B
L-1A 34
125
1" CW
3/4" HW-R
0' - 0"
13 8 3/4" HW
2" V
17 8 3/4" CW S-1
S-1 8
L-1A WC-2A 8 1 1/2" CW S-1 MEDICINE
4" FD-1 S-1 141
8 S-1
1
3 10
4 27 ULTRASOUND NURSES / MA DOCTORS 4
145 1" CW S-1 141B 141C
24' - 0"
STERIL. ROOM
1" HW 8 8
144 S-1
3/4" HW-R
S-1 29 EXAM
EXAM
SUPPORT CORRIDOR CLEAN UTILITY 140
133
STAIR #2 163 143 3/4" HW-R 3/4" HW-R
S102 1" HW 3/4" HW
16' - 0"
6" FCO
EXAM 3/4" HW EXAM EXAM 3/4" HW 3/4" CW EXAM EXAM
18 139 3/4" HW-R 137 3/4" HW-R 3/4" HW
8' - 0"
5 5
10 10 10
8" GCO
48' - 0"
3 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 2 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
1
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
PLUMBING KEYNOTES
0' - 0"
KEY
VALUE KEYNOTE TEXT
1 2" VENT UP TO 2" x 4" VENT THRU ROOF.
A A.5 A.8 B C D E
2 2-1/2" VENT UP TO 2-1/2" X 4" VENT THRU ROOF.
3 4" VENT UP TO 4" x 6" VENT THRU ROOF.
3' - 0"
2 1/2" V
2' - 0"
2" V
S-4 S-4 S-4 S-4
12 S-4 24 INDIVIDUALLY VALVED 3/4" COLD WATER AND 3/4" HOT WATER DROPS.
14 11 2" VENT DROP, 2" SANITARY DOWN THRU FLOOR SERVING BACK TO BACK SINKS. 2" VENT DOWN THRU
S-1 25 FLOOR. PROVIDE (2) SETS OF INDIVIDUALLY VALVED 3/4" COLD WATER AND 3/4" HOT WATER DROPS.
1" CW S-3 S-3 S-3 S-3 12 2" VENT DROP, 2" SANITARY DOWN THRU FLOOR SERVING SINK. 3" VENT DOWN THRU FLOOR. PROVIDE
1' - 0"
3/4" HW 8 3/4" CW INDIVIDUALLY VALVED 3/4" COLD WATER AND 3/4" HOT WATER DROPS.
3/4" HW-R 3/4" HW-R
3/4" HW-R 3/4" HW DENTAL CORRIDOR 3/4" HW 13 2" VENT DROP, 2" SANITARY DOWN THRU FLOOR SERVING SINK. PROVIDE (2) SETS OF INDIVIDUALLY
1" HW 14 25 3/4" HW-R 200D 3/4" CW VALVED 3/4" COLD WATER AND 3/4" HOT WATER DROPS SERVING SINK AND EMERGENCY EYEWASH.
6" SD PROVIDE EMERGENCY THERMOSTATIC MIXING VALVE UNDER COUNTER IN CABINET. EXTEND AND
1.5 1.5
1" = 1' - 0"
LEAD PHYSICAN 16 25 25 8 3/4" HOT WATER DOWN THRU FLOOR. EXTEND AND CONNECT TO SINK. FIELD VERIFY AND COORDINATE
213 S-1 WITH DENTAL EQUIPMENT CONTRACTOR.
3/4" CW
S-1 29 15 2" VENT DROP, 2" SANITARY DOWN THRU FLOOR SERVING SINK. PROVIDE INDIVIDUALLY VALVED (2) 3/4"
DENTAL EQUIPMENT
EEW-1 13 6 COLD WATER AND 3/4" HOT WATER DROPS SERVING SINK AND COLD WATER OUTLET. PROVIDE CHECK
DI-1 210 VALVE AT COLD WATER OUTLET. EXTEND AND CONNECT TO MODEL TRIMMER. FIELD VERIFY AND
DENTAL LAB 14 14 7
STERIL. LAB PASSENGER ELEVATOR
3" V
212 3" FD-1 COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR.
CLINIC MANAGER 211 3/4" DCV WORK ROOM P101
16 2" VENT DROP SERVING SINK. 2" SANITARY OFFSET IN WALL TO SANITARY RISER. PROVIDE INDIVIDUALLY
1.8 3/4" F-CW 200E 1.8 VALVED 3/4" COLD WATER AND 3/4" HOT WATER DROPS.
6' - 0"
214
CWO-1 EEW-1 17 2" VENT DROP SERVING CLINICAL SERVICE SINK. 4" SANITARY DOWN THRU FLOOR. (3) 2" VENT DOWN THRU
S-1 S-1 PUBLIC CORRIDOR FLOOR SERVING MOB BASIN AND (2) FLOOR DRAINS. PROVIDE INDIVIDUALLY VALVED 1-1/2" COLD WATER
28
2 1/2" V 200A AND 3/4" HOT WATER DROPS SERVING CLINICAL SERVICE SINK. PROVIDE INDIVIDUALLY VALVED 3/4" COLD
WATER AND 3/4" HOT WATER DROPS SERVING MOB BASIN.
DENTAL SOILED UTILITY 18 2" VENT DOWN THRU FLOOR SERVING FLOOR DRAIN.
2 15 3" FD-1
2
4' - 0"
216
3/4" HW-R 26 WATER FILTER (WF-1) LOCATED IN CABINET ABOVE SINK. PROVIDE DUAL CHECK BACKFLOW PREVENTER
2.5 1 1/2" HW
2.5
PUBLIC CORRIDOR UNDER CABINET. EXTEND AND CONNECT TO WATER FILTER.
2" CW
0' - 0"
200A 27 PROVIDE FILTERED WATER FOR DENTAL CHAIR. 3/4" FILTERED COLD WATER FED FROM BELOW. RIGHT
6 ANGLE MANUAL SHUT OFF VALVE SUPPLIED AND INSTALLED BY THE DENTAL EQUIPMENT CONTRACTOR.
7
PLUMBING CONTRACTOR SHALL PROVIDE A 2" TRAPPED AND VENTED DRAIN. REFER TO DENTAL
3 EQUIPMENT INSTALLATION REQUIREMENTS. FIELD VERIFY AND COORDINATE EXACT POINT OF NEW
TOILET-W TOILET-M P-401 CONNECTIONS.
SHARED CONFERENCE 221 220 28 PROVIDE POINT OF USE DI WATER SYSTEM FOR STERILE LAB 211. PROVIDE 3/4" COLD WATER DROP AND
ROOM 3/4" HW-R DUAL CHECK VALVE BACKFLOW PREVENTER. EXTEND AND CONNECT TO DEIONIZED WATER SYSTEM (DI-1).
1 1/2" HW 6" SD
EXTEND AND CONNECT TO FAUCET. FIELD VERIFY AND COORDINATE WITH DENTAL EQUIPMENT
12' - 0"
218
2" CW 6" OSD
6" SD
11 9 11 CONTRACTOR.
29 PROVIDE MPGL04GK2 MILLIPAK 40 0.22UM PT/HB MICROBIAL CAPSULE FILTER ON FAUCET. FIELD VERIFY
AND COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR.
3 3
6" OSD
ELEC 30 1" COLD WATER UP THRU ROOF SERVING NON-FREEZE POST HYDRANT. PROVIDE SHUT-OFF/DRAIN VALVE
3" V 4" V 4" V 2" V IN ACCESSIBLE AND CONVENIENT LOCATION FOR WINTERIZATION OF NON-FREEZE POST HYDRANT. 1"
222
S-1 S-1 S-1 S-1 S-1 INDIRECT DISCHARGE FROM NON-FREEZE POST HYDRANT. ROUTE TO OVER MOP BASIN AS INDICATED.
8' - 0"
4" V
WC-2A 9
18
3" FD-1 3/4" HW-R EXAM EXAM EXAM ISOLATION ROOM EXAM EXAM
19
1" HW 226 227 228 229 230 231
3.3 1" CW 3.3
4' - 0"
20
3
21 8 SOILED UTILITY
1/4" = 1' - 0"
4" V
0' - 0"
4" OSD
3" FD-1
1" SAN
PROVIDER STAFFING 225 241A
CSS-1 S-1 3/4" HW-R
246 3/4" HW
16 BARIATRIC EXAM
3/4" CW 3/4" HW-R
4" V 10 232
7 3/4" HW
DOCTORS
4" SD
3/4" HW-R 3/4" CW
22 23 6 241C 24 S-1
1" HW
24' - 0"
6" OSD
6" SD
5 S-1 241
1
24 S-1
16' - 0"
11 11 11
32' - 0"
3 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 2 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
1
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
A.5 A.8 B C D E
PLUMBING KEYNOTES
0' - 0"
KEY
A VALUE KEYNOTE TEXT
1 2-1/2" X 4" VENT THRU ROOF.
2 2" x 4" VENT THRU ROOF.
1 3 4" x 6" VENT THRU ROOF.
3' - 0"
1 1
2' - 0"
3
1' - 0"
1.5 1.5
1" = 1' - 0"
0' - 0"
3
1.8 1.8
6' - 0"
2 2
4' - 0"
2' - 0"
2.5 2.5
1/2" = 1' - 0"
0' - 0"
3 3
3
8' - 0"
3.3 3.3
4' - 0"
NFPH-1
1/4" = 1' - 0"
0' - 0"
24' - 0"
3
0' - 0"
5 5
48' - 0"
32' - 0"
GENERAL NOTE:
120' - 0"
3 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 2 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
1
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
17
3" V
0' - 6"
A 15 17 15 A.5
0' - 3"
2" V
19
3" = 1' - 0"
3"
2 1/2" V
V
12
PLUMBING KEYNOTES
0' - 0"
CW W-R 14 KEY
/2"
2 1 1/4" H 11 4" FD-1 4" FD-1 20 1" RPZ VALUE KEYNOTE TEXT
1
W 1 HOT WATER RETURN ASSEMBLY. REFER TO DETAIL ON SHEET P501.
V 2" H 2 DOMESTIC WATER PIPING TO SYSTEM. REFER TO FLOOR PLANS.
/2" 2.5 2.5
21 3 2" COLD WATER, 1-1/2" HOT WATER AND 3/4" HOT WATER RISERS DOWN THRU FLOOR.
10
3' - 0"
3" CW
W 7 3" VENT DOWN THRU FLOOR.
HWRP-1 13 2" H 3"
V 8 3/4" COLD WATER DROP SERVING ELECTRIC WATER COOLER. 2" VENT DROP, 2" SANITARY DOWN THRU
HWRP-1 FLOOR. 2" VENT DOWN THRU FLOOR.
3" V
2 1/2" V
2' - 0"
9 INCOMING 3" DOMESTIC WATER SERVICE ENTRY. 3" DOMESTIC WATER SERVICE, INCLUDING WATER
METER, ASSOCIATED STRAINER AND GATE VALVES IS INSTALLED UPSTREAM IN CIVIL "HOT BOX" HEATED
1" CW
2"
V ENCLOSURE. WATER METER SHALL BE SIZED PER WATER DEPARTMENT SIZING REQUIREMENTS. "HOT
17 BOX" IS PROVIDED AND INSTALLED BY CIVIL CONTRACTOR. REFER AND COORDINATE WITH CIVIL
4" FD-1 DRAWINGS.
2" HW
10 3/4" COLD WATER AND 3/4" HOT WATER TO DISTRIBUTION MAINS IN CORRIDOR.
4" FD-1
1 1/4" HW-R
DWBP-1
1' - 0"
1 1/2" CW
1 1/2" HW
AN 1 1/4" HW-R
4" S 13 HOT WATER RECIRCULATION PUMP (HWRP-1). REFER TO DETAIL ON SHEET P502. PLUMBING CONTRACTOR
SHALL PROVIDE AND INSTALL (2) HWRP-1 COMPLETE WITH ASSOCIATED TIMER AND AQUASTAT
1" = 1' - 0"
(REDUNDANCY). UNITS SHALL ALTERNATE HOURS OF OPERATION TO REDUCE WEAR AND TEAR.
2" V
13 HWRP-1
2" V
3" 14 HOT WATER RECIRCULATION PUMP. REFER TO DETAIL ON SHEET P501.
2" V
CW HWRP-1
0' - 0"
4" FD-1 4" MB-1 15 2" VENT DOWN THRU FLOOR SERVING FLOOR DRAIN.
3" CW
SA 4" FD-1 2 1/2" V
N 16 (3) 2" VENT DOWN THRU FLOOR.
2" HW 11 17 3" VENT TO PLUMBING FIXTURES.
4" FD-1
18 2" VENT TO PLUMBING FIXTURES.
3" V
4"
SA 19 EXTEND AND CONNECT 1" COLD WATER TO MECHANICAL EQUIPMENT.
N GWH-1 GWH-1 MTMV-1 4" FD-1
MTMV-1 20 1" COLD WATER DROP SERVING 1" REDUCED PRESSURE ZONE BACKFLOW PREVENTER (RPZ). DRAIN
2 1/2" V
ET-1 ET-1 DISCHARGE OUTLET INDIRECTLY TO OVER FLOOR DRAIN. PROVIDE AIR GAP.
6' - 0"
4"
W SA
3" C N 15
16
9
AN GWH-1
4" S
ET-1
4" FD-1
3" V
4' - 0"
GWH-1
ET-1
2' - 0"
A 17
A.5
1/2" = 1' - 0"
0' - 0"
A.8 B C 2
2
8' - 0"
EWC-1
2" CW 2" CW 2" CW
2 1 1/2" HW 1 1/2" HW 3/4" HW
3/4" HW-R 3/4" HW-R
2" C
W
1 1/2" HW
EL 3/4" HW-R
EV
4' - 0"
L 11
2" CW
OF
1 1/2" CW
/2" 3/4" HW
1 1/2" CW
3/4" HW
HW
RO - 0"
3/4" HW
' 1 1/2" CW
28 3/4
"
1/4" = 1' - 0"
HW
-R
3/4" HW-R
8
2" V
0' - 0"
3
3" FD-1 1/8" / 1'-0"
17 W
3/4" HW-R
A "C
P-P 1/2 5 6" SD 6" SD
3" F 1
"H
W
3 /4 1
3" FD-1 1/8" / 1'-0" 4
WC-1A WC-1 WC-1 WC-1A
3" V
24' - 0"
3/4
2" V "H
16' - 0"
W
3/4" HW
2
3" V
3 3
1 1/2" CW
1
3/4" CW
W
"H
3 /4
8' - 0"
L CW
VE /2"
3/4" HW-R
0L
E
WC-1A 11 A.8 B C
20 - 0" 4" 2" V
' SA 3" FD-1
14
1/8" = 1' - 0"
N
4" SAN
L-1 18
1 /8 3 200 LEVEL ENLARGED BATHROOMS
2" V "/
1'- P-401 3/8" = 1'-0"
0' - 0"
3" FP-PA
7
L-1A EWC-1 "/ D
1'-
0"
WC-1 6" O
SD
1 1/2" CW
21
2" SAN
6 /2"
SA
6" SD
N
48' - 0"
2" V
4
32' - 0"
5 17
21
/2"
L-1A SA
N
3" V
3" FD-1
16' - 0"
L-1
1/16" = 1' - 0"
U-1A
U-1
0' - 0"
4" SAN
WC-1A
120' - 0"
3" V
6
90' - 0"
3 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 2 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
1
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
CIRCUIT SETTER
CHECK VALVE
THERMOMETER
3" = 1' - 0"
STRAINER
REFER TO MECHANICAL DRAWINGS.
N.O.
0' - 0"
3"CW
3" COLD WATER TO BUILDING AND
DOMESTIC WATER BOOSTER PUMP.
1" VALVED DRAIN LINE TO OVER
HWRP-1 FLOOR
1-1/4" HOT WATER RE-CIRCULATION FLOOR DRAIN. PROVIDE AIR GAP.
GAS PIPING. REFER TO
BY-PASS VALVE MECHANICAL DRAWINGS.
3' - 0"
4"
4"
2-1/2"COLD WATER FROM CW CW THERMOMETER
5'-0" MINIMUM VALVE AND CAP 4"UG-SAN WITH 2"VENT
DOMESTIC WATER SYSTEM EARTH COVER
HW HW
HWR
FLOOR DRAIN BY PLUMBING
4"
4"
1-1/2" 1-1/2" CONTRACTOR
GAS PIPING. REFER TO
SLEEVE AND LINK SEAL PIPE
2' - 0"
HW
CONNECT AT MIDPOINT PROVIDE TIE ROD OR CONCRETE
OF COMMON PIPE THRUST BLOCK RESTRAINTS AT ALL
1-1/2" ASME TEMPERATURE & 5'-0"
ELBOWS AND CHANGES IN DIRECTION
PRESSURE RELIEF VALVE. PIPE
2"
1-1/2" DISCHARGE FULL SIZE TO NEW INCOMING 3" DOMESTIC WATER SERVICE ENTRY
1' - 0"
1-1/2" FLOOR DRAIN. PROVIDE AIR GAP. (DUCTILE IRON). WATER METER AND ASSOCIATED STRAINER
2-1/2"
CW
HW
HW
HW
ARE LOCATED UPSTREAM IN "HOT BOX" ENCLOSURE. WATER
G
1-1/4" METER SIZED AND INSTALLED PER WATER DEPARTMENT
REQUIREMENTS. REFER TO CIVIL DRAWINGS.
1" = 1' - 0"
GWH-1 GWH-1
CW
CW
27" MIN. 27" MIN.
(145°) (145°)
DETAIL
CW
ET-1 ET-1
TMV-1
DRAIN INDIRECTLY TO FLOOR
(120°) DRAIN. PROVIDE AIR GAP.
6' - 0"
FIRST FLOOR
DRAIN VALVE(TYPICAL) GAS CONTROL VALVE SHUT-OFF VALVE CAST IRON CLEANOUT WITH CAST IRON CLEANOUT WITH
POWER BURNER ASSEMBLY CONDENSATE P-TRAP REGULATOR COVER FOR DUTY REQUIRED COVER FOR DUTY REQUIRED
(TYPICAL). DIRT LEG "CO" TO BE
TAPERED BODY TAPERED BODY
4" CONCRETE HOUSEKEEPING PAD. CAST IN COVER
4' - 0"
2 N.T.S.
WATER HEATERS PIPING DETAIL
1/2" = 1' - 0"
3/4" CHECK VALVE 3/4" BALL VALVE TERMINATE SLEEVE FLUSH PARTITIONS SHALL BE 20 GAUGE SHEET METAL. THE SPACE
STEEL PIPE SLEEVE TO
WITH FINISHED WALL BETWEEN THE PIPE AND ITS SLEEVE SHALL NOT EXCEED ONE-
3/4" BALL VALVE PASS PIPE
SURFACES HALF INCH. THE SLEEVE SHALL HAVE A SUFFICIENT LENGTH TO BE NOTE: CLEANOUTS SHALL BE
FLUSH WITH THE FINISHED WALL SURFACE. FLOW INSTALLED EVERY 45 TO 50 FEET FLOW
B. EXPOSED PIPING PASSING THROUGH WALLS, FLOORS OR CEILING ON THE HORIZONTAL RUN
3/4" HWR FROM FIXTURES 3/4" HWR TO WATER HEATER SHALL BE FITTED WITH CHROMIUM-PLATED CAST BRASS TO BUILDING DRAIN OR TO BUILDING DRAIN OR
8' - 0"
REFER TO SPECS. OPENING AND THE PIPE SHALL NOT EXCEED ONE-HALF INCH.
C. ANNULAR SPACES BETWEEN PIPING AND SLEEVES OR CORE
DRILLED FLOOR OPENINGS SHALL BE PACKED WITH MINERAL
WOOL AND SEALED, TO RETAIN THE FIRE INTEGRITY OF THE
0' - 0"
WEEP HOLES
PLUG-IN POWER CORD TO PUMP
DETAIL
BRAIDED FLOOR
CEMENT BED
WATERPROOF MEMBRANE 6 PIPE SLEEVE THRU INTERIOR WALL DETAIL
0' - 0"
PRIMER N.T.S.
ESCUTCHEON
CONCRETE FILL
HOSE
CLEANOUT
UNION
VENT PIPING
GATE VALVE
CHECK VALVE PIPE MOUNTED LEVEL SENSOR
AND OIL DETECTOR
FLASHING CLAMP
LAVATORY WITH WEEP HOLES
32' - 0"
FLOAT SWITCH
STRUCTURAL SLAB COUNTER
PROVIDE A METAL SUPPORT
SINK
PLATE WHEN DRAIN IS THREADED, CAULKED OR
WALL CHASE INSTALLED IN AN EXISTING NO-HUB CONNECTION 2" VENT
FLOOR - CAULK AROUND
16' - 0"
ASSE 1044
WATER SAVER
DRAIN PRIOR TO PIPE SIZE AS NOTED ON PLAN
TRAP PRIMER TRAP PRIMER RE-GROUTING
1/16" = 1' - 0"
FLOOR SLAB
ELEVATOR SUMP PUMP (ESP-1) SEALANT (TYP.)
2" SINK WASTE IN WALL
2" WASTE BEHIND SINK CABINET
NOTES:
1. COORDINATE LOCATION OF PUMP DISCHARGE PIPING AND SUMP PUMP SYSTEM CONTROL PANEL WITH THE
ELEVATOR CONTRACTOR.
120' - 0"
2. INSTALL ELEVATOR SUMP PUMP SYSTEM INCLUDING SUMP PUMP, LEVEL SENSOR/ OIL DETECTOR, CONTROL DEEP SEAL FLOOR
PANEL, AND REMOTE ALARM PER MANUFACTURER'S RECOMMENDATIONS. CONNECTION TO TRAP P-TRAP
3 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 2 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
1
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
FLOW
0' - 6"
0' - 3"
0' - 0"
ALL THREAD
HANGER ROD.
SUPPORT UNINSULATED PIPE IN-LINE RECIRCULATING
FROM PUMP (SEE PUMP SCHEDULE)
STRUCTURE*
INSULATION
2' - 0"
INSULATION
PIPE
DIAL TYPE PRESSURE GAUGE
PIPE
(0-100 PSIG)
WELD
UNION
1' - 0"
5 MICRON RESIN
DUAL CHECK VALVE TYPE
PRESSURE GAUGE DUAL CHECK VALVE TYPE CARTRIDGE PRESSURE GAUGE TRAP FILTER
BACKFLOW PREVENTER
(TYP.) BACKFLOW PREVENTER CARBON FILTER (TYP.)
(ASSE 1024)
1/2" = 1' - 0"
(ASSE 1024)
TWO POINTS OF USE
1" CW IN 1" FILTERED
1" CW IN 3/8 INCH POLY TUBING
0' - 0"
WATER OUT
UNION
(TYP.) WATER PRIMARY POLISHER
FILTER
PRIMARY AND POLISHER D-45
MIXBED DEIONIZERS 8"x18"
8' - 0"
NOTE:
NOTE: 1. PROVIDE ROOM FOR INSULATING PIPING. ALL INTERCONNECTION
1. PROVIDE ROOM FOR INSULATING PIPING. PIPING IS 3/8 INCH TUBING. TWO 120VAC OUTLETS REQUIRED.
DETAIL DETAIL
4' - 0"
5 N.T.S.
WATER FILTER INSTALLATION
4 N.T.S.
POINT OF USE DEIONIZER INSTALLATION
1/4" = 1' - 0"
0' - 0"
24' - 0"
16' - 0"
8' - 0"
1/8" = 1' - 0"
0' - 0"
48' - 0"
32' - 0"
16' - 0"
1/16" = 1' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
Drawn FA
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
4
No.
06/25/2019
Date
ISSUE FOR BID
Issue
Drawings are not to be scaled.
GENERAL PLUMBING FIXTURE NOTES: OUTLET WASTE VENT COLD WATER HOT WATER
1. SEE ARCHITECTURAL PLANS AND DETAILS FOR ROUGH-IN ROUGH-IN ROUGH-IN CONNECTOR
PLUMBING FIXTURE MOUNTING HEIGHTS.
MOTION SENSOR VOLUME PER PIPE PIPE
2. FLUSH HANDLE ON ALL A.D.A. COMPLIANT WATER
TAG QTY DESCRIPTION MANUFACTURER MODEL MATERIAL DESCRIPTION FINISH WFU OUT MANUFACTURER MODEL TYPE CONTROL FLUSH PIPE SIZE WFU SIZE PIPE SIZE CWFU DIAMETER HWFU SPECIFICATION REMARKS
CLOSETS SHALL BE ON THE "WIDE" SIDE OF THE
0' - 6"
TOILET ROOM. COORDINATE WITH ARCHITECTURAL CSS-1 3 CLINICAL SERVICE SINK AMERICAN STANDARD 9515.999.020 WHITE VITREOUS CHINA WHITE 6 ZURN INDUSTRIES Z60842AV-BWN-BG-H MANUAL 4” 6 12.25 2.25 CLINICAL SERVICE SINK - WALL HUNG, BLOW OUT FLUSHING RIM. FLUSH VALVE/FAUCET: 6 GPF, QUIET DIAPHRAGM TYPE, CHROME PLATED, PROVIDE WALL CARRIER.
DETAILS AND VERIFY IN FIELD. NON-HOLD OPEN, WALL BRACKET, SUPPORT ROD, CONTROL STOP HAS INTERNAL SIPHON GUARD PROTECTION, BEDPAN WASHER
3. FURNISH AND INSTALL ASSE 1016 THERMOSTATIC ASSEMBLY, BIOCARE HANDLE, HANDLE ON FRONT OF FLUSH VALVE, 4" VANDAL RESISTANT BRASS WRISTBLADE COLOR CODED HANDLES.
MIXING VALVE TO LIMIT HOT WATER DISCHARGE PROVIDE RIM/WALL GUARD MODEL 7832512.075.
TEMPERATURE TO 110°F MAX. FOR LAVATORIES AND EWC-1 2 ELECTRIC WATER COOLER ELKAY LZSTL8WS-S GALVANIZED STEEL STAINLESS 0.5 No 2” 0.5 1-1/2” 1/2” 0.25 0 ELECTRIC WATER COOLER WITH BOTTLE FILLING STATION - 8 GPH, INTEGRATED SILVER ION ANTI-MICROBIAL PROTECTION, SANITARY, PROVIDE WALL CARRIER.
0' - 3"
SINKS AT JOB COMPLETION. PIPE PER STEEL CABINET TOUCHLESS ACTIVATION (BOTTLE FILLER), EASY-TOUCH FRONT AND SIDE PUSHBAR CONTROLS (COOLER), WATERSENTRY PLUS 3000
MANUFACTURER AND FAUCET TYPE GALLON CAPACITY FILTRATION SYSTEM, LAMINAR FLOW, FLEXI-GUARD STREAM SAVER, VISUAL USER INTERFACE DISPLAY, REAL DRAIN
SPECIFICATIONS. FURNISH AND INSTALL LEAD-FREE SYSTEM.
3" = 1' - 0"
THERMOSTATIC MIXING VALVE, WATTS LFUSG-B-M2. GYD-1 2 EXTERIOR GROUND YARD HYDRANT J.R. SMITH 5811-HC1-W-NB BRONZE NICKEL BRONZE MANUAL No 0 1” 3 0 GROUND YARD HYDRANT - HINGED COVERED BOX, NICKEL BRONZE BOX, 1" HOSE CONNECTION ADAPTOR, "WATER" CAST ON COVER, "T" PROVIDE REDUCED PRESSURE ZONE BACKFLOW PREVENTER (RPZ).
4. A.D.A. COMPLIANT STAINLESS STEEL SINKS TO HAVE HANDLE KEY. LOCATE IN BACK OF THE HOUSE ROOM (MECHANICAL ROOM, JANITOR'S
0' - 0"
"OFF-CENTERED REAR" DRAIN OPENING. CLOSET, ETC.) AND EXTEND AND CONNECT TO FIXTURE UNDERGROUND.
5. PROVIDE A CONTINUOUS PLASTIC SLEEVE PIPE RPZ DISCHARGE TO OVER NEAREST DRAIN RECEPTOR.
ENCASEMENT PER CODE SECTION 18-29-420.3.
L-1 4 LAVATORY - COUNTER AMERICAN STANDARD K2210 WHITE VITREOUS CHINA WHITE 1 KOHLER K13468 ELECTRONIC Yes 2” 1 1-1/2” 1/2” 1.5 1/2" 1.5 LAVATORY - UNDERMOUNT, OVAL BASIN WITH GLAZED UNDERSIDE, OVERFLOW DRAIN. FAUCET:SINGLE HOLE MOUNTING, ELECTRONIC
COORDINATE WITH ARCHITECT.
HARDWIRED, VANDAL RESISTANT AERATOR, WITH MIXER. PROVIDE THERMOSTATIC MIXING VALVE. PROVIDE TRANSFORMER. PROVIDE
6. INSTALL VACUUM BREAKER@7'-6". VERIFY IF
STRAINER, P-TRAP, TAILPIECES, SUPPLIES AND STOPS.
REQUIRED BY LOCAL CODE.
7. FURNISH AND INSTALL McGUIRE 8903, 1-1/2", CAST L-1A 7 LAVATORY - COUNTER - ADA AMERICAN STANDARD K2210 WHITE VITREOUS CHINA WHITE 1 KOHLER K13468 ELECTRONIC Yes 2” 1 1-1/2” 1/2” 1.5 1/2" 1.5 LAVATORY - ADA COMPLIANT, UNDERMOUNT, OVAL BASIN WITH GLAZED UNDERSIDE, OVERFLOW DRAIN. FAUCET:SINGLE HOLE MOUNTING,
BRASS BODY, CHROME PLATED P-TRAP WITH ELECTRONIC HARDWIRED, VANDAL RESISTANT AERATOR, WITH MIXER. PROVIDE THERMOSTATIC MIXING VALVE. PROVIDE TRANSFORMER.
3' - 0"
CLEANOUT PLUG AND ESCUTCHEON. PROVIDE STRAINER, P-TRAP, TAILPIECES, SUPPLIES AND STOPS. INSULATE WATER AND WASTE TO MEET ADA REQUIREMENTS.
8. FURNISH AND INSTALL McGUIRE H2165LK, HEAVY L-2A 1 LAVATORY - WALL HUNG - ADA TOTO LHT242G WHITE VITREOUS CHINA WHITE 1 KOHLER K13468 ELECTRONIC Yes 2” 1 1-1/2” 1/2” 1.5 1/2" 1.5 LAVATORY - ADA COMPLIANT, WALL HUNG, REAR OVERFLOW. FAUCET:SINGLE HOLE MOUNTING, ELECTRONIC HARDWIRED, VANDAL ADA COMPLIANT ONLY WITHOUT SHROUD. PROVIDE WALL CARRIER.
DUTY ANGLE SUPPLY STOP, BRASS BODY, CHROME RESISTANT AERATOR, WITH MIXER. PROVIDE THERMOSTATIC MIXING VALVE. PROVIDE TRANSFORMER. PROVIDE STRAINER, P-TRAP,
PLATED WITH ESCUTCHEON, CHROME PLATED TAILPIECES, SUPPLIES AND STOPS. INSULATE WATER AND WASTE TO MEET ADA REQUIREMENTS.
COPPER TUBE RISER, BRASS STEM, LOOSE KEY. MB-1 3 MOP BASIN CREATIVE INDUSTRIES VENETIAN PRECAST TERRAZZO WHITE 2 CHICAGO FAUCET CO 911-ISCP MANUAL No 3” 2 2” 3/4” 2.25 3/4" 2.25 MOP BASIN, 24"x24"x12" HIGH, STAINLESS STEEL CAP EDGE, VANDAL PROOF DRAIN. FAUCET: WALL MOUNTED, INTEGRAL SERVICE STOPS,
9. FURNISH AND INSTALL PROWRAP PW2000, 612-MC2424-612 5-3/4" RIGID SPOUT, WALL FLANGE, PAIL HOOK, 3" CROSS HANDLES, ELEVATED VACUUM BREAKER ASSEMBLY, 3/4" MALE HOSE THREAD
2' - 0"
INSULATING KIT FOR TAILPIECE, P-TRAP, OFFSET OUTLET, WALL BRACE ASSEMBLY. PROVIDE WALL PROTECTION, MOP HANGER, HOSE AND HOSE BRACKET, STAINLESS STEEL WALL GUARD,
DRAIN, WALL BEND, AND 2 SUPPLY COVERS. SILICONE SEALANT.
NFPH-1 1 ROOF HYDRANT WOODFORD RHY2-MS MANUAL No 0 1” 5 0 NON-FREEZE TYPE ROOF HYDRANT, WITH ASSE 1052 DOUBLE CHECK BACKFLOW PREVENTER, VALVE ON THE INSIDE OF THE ROOF, HOSE
CONNECTION WITH BACKFLOW PREVENTER, AND CLOCKING HANDLE ON THE OUTSIDE OF THE ROOF. ALL EXPOSED PARTS SHALL BE
PAINTED. MAKE ARRANGEMENTS WITH THE GENERAL CONTRACTOR TO PROVIDE THE NECESSARY SUPPORT OF ROOF. PROVIDE SHUTOFF
VALVE IN ACCESSIBLE LOCATION AND ROUTE DRAIN PIPE TO NEAREST DRAIN RECEPTOR. PROVIDE ACCESS PANEL WHERE REQUIRED.
1' - 0"
NFWH-1 1 EXTERIOR WALL HYDRANT WOODFORD 67 MANUAL No 0 3/4” 3 0 NON-FREEZE TYPE WALL HYDRANT, WITH DOUBLE CHECK BACKFLOW PREVENTER, VALVE ON THE INSIDE OF THE WALL, SPOUT WITH
BACKFLOW PREVENTER, AND LOOSE KEY SOCKET ON THE OUTSIDE OF THE WALL. MAKE ARRANGEMENTS WITH THE GENERAL CONTRACTOR
TO PROVIDE THE NECESSARY RECESS IN THE WALL. WHERE A RISER TO A WALL HYDRANT OCCURS IN AN OUTSIDE WALL THE CONTRACTOR
SHALL INSULATE THE CHASE WITH 2” STYROFOAM INSULATION ON ALL SIDES OF THE CHASE, EXCEPT THE INSIDE WALL OF THE CHASE.
PROVIDE SHUTOFF VALVE IN ACCESSIBLE LOCATION.
1" = 1' - 0"
S-1 52 EXAM ROOM SINK - SINGLE ELKAY LR1919PD STAINLESS STEEL STAINLESS 2 CHICAGO FAUCET CO 1100-E35-317ABCP MANUAL No 2” 2 2” 1/2” 1.5 1/2" 1.5 SINGLE COMPARTMENT, ADA COMPLIANT, SELF-RIMMING, 18 GAUGE. SINGLE LEVER SWIVEL FAUCET. ONE ELKAY MODEL NO. LK35 BASKET
STEEL STRAINER, P-TRAP, TAILPIECES, SUPPLIES AND STOPS. INSULATE WATER AND WASTE TO MEET ADA REQUIREMENTS.
0' - 0"
S-2 1 BREAK ROOM SINK ELKAY DEMR23322R STAINLESS STEEL STAINLESS 2 KOHLER PURIST K7505-CP MANUAL No 2” 2 2” 1/2” 1.5 1/2" 1.5 SINGLE COMPARTMENT, ADA COMPLIANT, SELF-RIMMING, 18 GAUGE. SINGLE LEVER SWIVEL FAUCET. ONE ELKAY MODEL NO. LK35 BASKET
FIXTURE UNIT SUMMARY STEEL STRAINER, P-TRAP, TAILPIECES, SUPPLIES AND STOPS. INSULATE WATER AND WASTE TO MEET ADA REQUIREMENTS.
U-1 2 URINAL AMERICAN STANDARD WASHBROOK 6590.001 WHITE VITREOUS CHINA WHITE 2 SLOAN ROYAL 186 ELECTRONIC Yes 0.125 gal 2” 2 1-1/2” 3/4” 5 0 URINAL, WALL HUNG, ULTRA HIGH EFFICIENCY, FLUSHING RIM, WASHOUT FLUSH ACTION. FLUSH VALVE: 0.125 GPF, DUAL FILTERED BYPASS, PROVIDE WALL CARRIER.
FIXTURE UNITS ESS-0.125-DBP-TMO-HW POLISHED CHROME FINISH, TRUE MECHANICAL OVERRIDE, HARDWIRED, EXPOSED, OPTIMA EL-1500 SELF ADAPTIVE INFRARED SENSOR WITH
TAG QTY FIXTURE DESCRIPTION WFU CWFU HWFU INDICATOR LIGHT.
CSS-1 3 CLINICAL SERVICE SINK 18 36.75 6.75 U-1A 2 URINAL - ADA AMERICAN STANDARD WASHBROOK 6590.001 WHITE VITREOUS CHINA WHITE 2 SLOAN ROYAL 186 ELECTRONIC Yes 0.125 gal 2” 2 1-1/2” 3/4” 5 0 URINAL, WALL HUNG, ULTRA HIGH EFFICIENCY, FLUSHING RIM, WASHOUT FLUSH ACTION. FLUSH VALVE: 0.125 GPF, DUAL FILTERED BYPASS, PROVIDE WALL CARRIER.
ESS-0.125-DBP-TMO-HW POLISHED CHROME FINISH, TRUE MECHANICAL OVERRIDE, HARDWIRED, EXPOSED, OPTIMA EL-1500 SELF ADAPTIVE INFRARED SENSOR WITH
6' - 0"
INDICATOR LIGHT.
CWO-1 1 COLD WATER OUTLET 0 1.5 1.5
WC-1 4 WATER CLOSET - WALL HUNG AMERICAN STANDARD AFWALL 3351.101 WHITE VITREOUS CHINA WHITE 6 SLOAN ROYAL 111 ELECTRONIC Yes 1.280 gal 4” 6 2” 1” 10 0 WATER CLOSET, WALL HUNG, HET HIGH EFFICIENCY TOILET, PERMANENT EVERCLEAN, CONDENSATION CHANNEL, ELONGATED BOWL, PROVIDE WALL CARRIER.
ESS-1.28-YO-TMO-HW DIRECT FED SIPHON JET ACTION. FLUSH VALVE: 1.28 GPF, ANGLE STOP BUMPER, POLISHED CHROME FINISH, TRUE MECHANICAL OVERRIDE,
DI-1 1 DEIONIZED WATER SYSTEM 0 1.5 1.5 EXPOSED, HARDWIRED, OPTIMA EL-1500 SELF ADAPTIVE INFRARED SENSOR WITH INDICATOR LIGHT. SEAT: BEMIS MODEL 3155SSCT, OPEN
FRONT LESS COVER, ELONGATED, EXTRA HEAVY DUTY, SELF SUSTAINING CHECK HINGES, STA-TITE COMMERCIAL FASTENING SYSTEM,
DT-1 5 DENTAL TRAP 0 7.5 7.5 DURAGUARD ANTIMICROBIAL.
4' - 0"
WC-1A 4 WATER CLOSET - WALL HUNG - ADA AMERICAN STANDARD AFWALL 3351.101 WHITE VITREOUS CHINA WHITE 4 SLOAN ROYAL 111 ELECTRONIC Yes 1.280 gal 4” 4 2” 1” 10 0 WATER CLOSET, WALL HUNG, HET HIGH EFFICIENCY TOILET, PERMANENT EVERCLEAN, CONDENSATION CHANNEL, ELONGATED BOWL, PROVIDE WALL CARRIER.
EEW-1 2 EMERGENCY EYEWASH 0 3 3 ESS-1.28-YO-TMO-HW DIRECT FED SIPHON JET ACTION. FLUSH VALVE: 1.28 GPF, ANGLE STOP BUMPER, POLISHED CHROME FINISH, TRUE MECHANICAL OVERRIDE,
EXPOSED, HARDWIRED, OPTIMA EL-1500 SELF ADAPTIVE INFRARED SENSOR WITH INDICATOR LIGHT. SEAT: BEMIS MODEL 3155SSCT, OPEN
FRONT LESS COVER, ELONGATED, EXTRA HEAVY DUTY, SELF SUSTAINING CHECK HINGES, STA-TITE COMMERCIAL FASTENING SYSTEM,
EWC-1 2 ELECTRIC WATER COOLER 1 0.5 0
DURAGUARD ANTIMICROBIAL.
WC-2A 4 WATER CLOSET - FLOOR MOUNT - FLUSH AMERICAN STANDARD 3641.001 WHITE VITREOUS CHINA WHITE 6 SLOAN ROYAL 111 ELECTRONIC Yes 1.280 gal 4” 6 2” 1” 10 0 WATER CLOSET, FLOOR MOUNTED, ELONGATED BOWL, HET HIGH EFFICIENCY TOILET. FLUSH VALVE: 1.28 GPF, ANGLE STOP BUMPER,
FD-1 8 FLOOR DRAIN 48 0 0
2' - 0"
VALVE - ADA - BARIATRIC ESS-1.28-YO-TMO-HW POLISHED CHROME FINISH, TRUE MECHANICAL OVERRIDE, EXPOSED, HARDWIRED, OPTIMA EL-1500 SELF ADAPTIVE INFRARED SENSOR WITH
FD-1 11 FLOOR DRAIN 88 0 0 INDICATOR LIGHT. SEAT: BEMIS MODEL 3155SSCT, OPEN FRONT LESS COVER, ELONGATED, EXTRA HEAVY DUTY, SELF SUSTAINING CHECK
HINGES, STA-TITE COMMERCIAL FASTENING SYSTEM, DURAGUARD ANTIMICROBIAL.
GT-1 1 GREASE INTERCEPTOR 0 0 0 Grand total: 93
1/2" = 1' - 0"
HYDRANT
MB-1 3 MOP BASIN 6 6.75 6.75 DENTAL EQUIPMENT SCHEDULE DOMESTIC WATER BOOSTER PUMP SCHEDULE
PIPE CONNECTIONS PUMP ELECTRICAL
NFPH-1 1 ROOF HYDRANT 0 5 0
WASTE VENT COLD WATER HOT WATER MOTOR
CONNE TAG MANUFACTURER MODEL NO. SYSTEM TYPE FLOW (PEAK) QUANTITY POWER (EACH) VOLTAGE PHASE REMARKS
8' - 0"
NFWH-1 1 EXTERIOR WALL HYDRANT 0 3 0 ROUGH-IN PIPE ROUGH-IN ROUGH-IN CTOR DWBP-1 SYNCROFLO 100-VFD-28-PW DOMESTIC WATER DUPLEX 100.0 GPM 2 3 hp 208 V 3 DOMESTIC WATER BOOSTER PUMP. UNIT IS A PACKAGED SKID
TAG QTY DESCRIPTION MANUFACTURER MODEL PIPE SIZE WFU SIZE PIPE SIZE CWFU PIPE SIZE HWFU SPECIFICATION REMARKS SYSTEM. PROVIDE 4" HIGH CONCRETE HOUSEKEEPING PAD.
S-1 52 EXAM ROOM SINK - SINGLE 104 78 78 CWO-1 1 COLD WATER OUTLET GUY GRAY MIB1HAAB --- 0 --- 1/2” 1.5 --- 1.5 COLD WATER OUTLET BOX, QUARTER TURN HAMMER ARRESTOR, LEAD FREE. EXTEND AND CONNECT TO DENTAL EQUIPMENT. COORDINATE WITH Grand total: 1
DENTAL EQUIPMENT CONTRACTOR. VERIFY QUANITITY, LOCATIONS
S-2 1 BREAK ROOM SINK 2 1.5 1.5 AND PIPE ROUTING.
DI-1 1 DEIONIZED WATER SYSTEM CULLIGAN D-45 SYSTEM --- 0 --- 1/2” 1.5 --- 1.5 DEIONIZED WATER SYSTEM, CARBON / MIXED BED FILTRATION. FINAL HOOK UP TO FIXTURES BY PLUMBING COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR. VERIFY
4' - 0"
S-3 6 DENTAL EXAM SINK - SINGLE 12 9 9 CONTRACTOR. COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR ON REQUIRED COMPONENTS AND QUANITITY, LOCATIONS AND PIPE ROUTING.
FINAL CONNECTIONS. INSTALL EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. PROVIDE DUAL CHECK GAS-FIRED WATER HEATER SCHEDULE
VALVE BACKFLOW PREVENTER UPSTREAM OF EQUIPMENT.
S-4 6 DENTAL CHAIR - SINGLE 12 9 9
1/4" = 1' - 0"
DT-1 5 DENTAL TRAP BY OTHERS BY OTHERS --- 0 --- --- 1.5 --- 1.5 DENTAL TRAP, PROVIDED BY OTHERS. FINAL HOOK UP TO FIXTURES BY PLUMBING CONTRACTOR. COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR. VERIFY GAS-FIRED HEAT EXCHANGER ELECTRICAL
COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR ON REQUIRED COMPONENTS AND FINAL QUANITITY, LOCATIONS AND PIPE ROUTING. GAS BURNER WATERSIDE
U-1 2 URINAL 4 10 0 SHIPPING
CONNECTIONS. INSTALL EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. FUEL STORAGE WEIGHT
0' - 0"
S-3 6 DENTAL EXAM SINK - SINGLE BY OTHERS BY OTHERS 2” 2 2” 1/2” 1.5 1/2” 1.5 INTEGRAL TO CABINET. PROVIDED BY OTHERS. FINAL HOOK UP TO FIXTURES BY PLUMBING CONTRACTOR. COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR. VERIFY TAG MANUFACTURER MODEL NO. TYPE INPUT STAGES TYPE RECOVERY@100°F VOL THERMAL EFF (ASME) FLA VOLT PH REMARKS
U-1A 2 URINAL - ADA 4 10 0 COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR ON REQUIRED COMPONENTS AND FINAL QUANITITY, LOCATIONS AND PIPE ROUTING.
GWH-1 AO SMITH BTH-120A Mxi CONDENSING 120000 Btu/h 2 NG 138 gal/h 60.0 gal 95% 490 lb 5.8 A 120 V 1 PROVIDE ASSE 1017 COMPLIANT MIXING VALVE; POWERS SERIES LFSH
CONNECTIONS. INSTALL EQUIPMENT PER MANUFACTURER'S REQUIREMENTS.
OR EQUAL. PROVIDE EXPANSION TANK. PROVIDE NEUTRALIZATION KIT
WC-1 4 WATER CLOSET - WALL HUNG 24 40 0 S-4 6 DENTAL CHAIR - SINGLE BY OTHERS BY OTHERS 2” 2 2” 1/2” 1.5 --- 1.5 INTEGRAL TO CHAIR. PROVIDED BY OTHERS. FINAL HOOK UP TO FIXTURES BY PLUMBING CONTRACTOR. COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR. VERIFY AND ROUTE TO NEAREST DRAIN RECEPTOR. PROVIDE AIR GAP. PROVIDE
COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR ON REQUIRED COMPONENTS AND FINAL QUANITITY, LOCATIONS AND PIPE ROUTING. 4" HIGH CONCRETE HOUSEKEEPING PAD.
CONNECTIONS. INSTALL EQUIPMENT PER MANUFACTURER'S REQUIREMENTS.
WC-1A 4 WATER CLOSET - WALL HUNG - 16 40 0 GWH-1 AO SMITH BTH-120A Mxi CONDENSING 120000 Btu/h 2 NG 138 gal/h 60.0 gal 95% 490 lb 5.8 A 120 V 1 PROVIDE ASSE 1017 COMPLIANT MIXING VALVE; POWERS SERIES LFSH
ADA WF-1 1 WATER FILTER SYSTEM DUPONT WFHD13001B --- 0 --- 1” 1.5 --- 1.5 WATER FILTER SYSTEM INSTALLED ABOVE IN CABINET. PROVIDE DUAL CHECK BACKFLOW PREVENTER COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR. VERIFY OR EQUAL. PROVIDE EXPANSION TANK. PROVIDE NEUTRALIZATION KIT
24' - 0"
UPSTREAM OF EQUIPMENT. INSTALL IN CABINET UNDER COUNTER. EXTEND AND CONNECT TO EQUIPMENT. QUANITITY, LOCATIONS AND PIPE ROUTING. AND ROUTE TO NEAREST DRAIN RECEPTOR. PROVIDE AIR GAP. PROVIDE
FINAL HOOK UP TO FIXTURES BY PLUMBING CONTRACTOR. COORDINATE WITH DENTAL EQUIPMENT 4" HIGH CONCRETE HOUSEKEEPING PAD.
WC-2A 4 WATER CLOSET - FLOOR 24 40 0 CONTRACTOR ON REQUIRED COMPONENTS AND FINAL CONNECTIONS. INSTALL EQUIPMENT PER
MOUNT - FLUSH VALVE - ADA - MANUFACTURER'S REQUIREMENTS.
BARIATRIC Grand total: 20
0' - 0"
CONTRACTOR. TAG DESCRIPTION MANUFACTURER MODEL TEMP. COLD TEMP. HOT TEMP. (SYSTEM) DIAMETER DIAMETER SPECIFICATION REMARKS
ESP-1 LIBERTY PUMPS ELV293 50.0 GPM 1 0.50 hp 3450 115 V 1 PROVIDE SEEWATER OIL SMART SIMPLEX PANEL PACKAGE OSSM-30-CB, WHICH INCLUDES MTMV MASTER THERMOSTATIC LEONARD TM-820B-LF-DT-IT-TC 120 °F 40 °F 145 °F 47.0 GPM 1" 1 1/4" LEAD FREE, ADJUSTABLE HIGH TEMPERATURE LIMIT STOP, INLET CHECKSTOPS,
OIL SMART WATER PUMP SWITCH AND LIQUID SWITCH ALARM SENSOR. 120V., 1 PHASE MIXING VALVE INLET MANIFOLD PIPING, LOCKING TEMPERATURE REGULATORS, INLET
PANEL TO BE MOUNTED OUTSIDE CONTAINMENT AREA. COORDINATE WITH ELECTRICAL THERMOMETERS, TEST CONNECTION.
CONTRACTOR.
Grand total: 1
Grand total: 2
32' - 0"
GT-1 1 MIFAB MI-ROC-2 GREASE TRAP, ACID RESISTANT POWDER EPOXY COATED INSIDE AND OUTSIDE. 8 GPM
FLOW, 12 LBS GREASE CAPACITY, 3.5 GAL. LIQUID HOLDING CAPACITY. INSTALL IN
CABINET UNDER SINK. INSTALL PER MANUFACTURER'S REQUIREMENTS.
1/16" = 1' - 0"
Grand total: 1
0' - 0"
OUT/FLUSH FITTING. PROVIDE WITH QT-SET QUICK TEST FITTING SET, C IRON BODIES, COMBINATION MEMBRANE FLASHING, CLAMP/GRAVEL GUARDS, DOUBLE CAST IRON REVERSIBLE CLAMPING COLLAR WITH PRIMARY & SECONDARY CONNECTION FOR FIXTURES IN RESTROOMS.
WINTERIZING BLOW OUT/FLUSH FITTING. COORDINATE FINAL LOCATION TOP-SET DECK PLATE, LOW SILHOUETTE CAST IRON DOMES, INSIDE CAULK, VANDAL WEEPHOLES, ADJUSTABLE ROUND HEEL PROOF NICKEL BRONZE
WITH ARCHITECT. PROVIDE ACCESS COVER. PROOF SECURED TOP, SECONDARY CLAMPING COLLAR. STRAINER, INSIDE CAULK.
BFP-2 4 1" RD-1 5 COMBINATION DRAINS ZURN INDUSTRIES Z164-IC-VP-S DURA-COATED CAST IRON CAST IRON DOME 6” COMBINATION PRIMARY AND SECONDARY ROOF DRAINS - 12" DIA., DURA-COATED CAST FD-1 11 FLOOR DRAIN WATTS FD-100-A EPOXY COATED NICKEL BRONZE 4” 2” EPOXY COATED CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE, PROVIDE DEEP SEAL P-TRAP. PROVIDE TRAP PRIMER
C IRON BODIES, COMBINATION MEMBRANE FLASHING, CLAMP/GRAVEL GUARDS, DOUBLE CAST IRON REVERSIBLE CLAMPING COLLAR WITH PRIMARY & SECONDARY CONNECTION FOR FIXTURES IN RESTROOMS.
TOP-SET DECK PLATE, LOW SILHOUETTE CAST IRON DOMES, INSIDE CAULK, VANDAL WEEPHOLES, ADJUSTABLE ROUND HEEL PROOF NICKEL BRONZE
90' - 0"
3 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 2 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
1
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
PLUMBING KEYNOTES
0' - 0"
KEY
VALUE KEYNOTE TEXT
1 ELEVATOR SUMP PUMP DISCHARGE UP. PROVIDE CHECK VALVE AND BALL VALVE ON RISE. ROUTE PUMP
DISCHARGE TO NEAREST DRAIN RECEPTOR UNDER SINK AS INDICATED. PROVIDE AIR GAP.
2 2" SANITARY UP THRU FLOOR.
3 3" SANITARY UP TO JANITOR'S MOP BASIN WITH 2" VENT UP.
3' - 0"
2
5
1' - 0"
1'-0"
1/8" /
1" = 1' - 0"
4" SAN
0' - 0"
2
6" SAN
6' - 0"
1'-0"
1/8" /
4"
5
1
SA
2
4" SAN
N
1'-0"
1/8" /
2 6" SAN
2 5
5
1'-0"
4' - 0"
1/8" /
4" SAN
9
9
2' - 0"
1/8" /
S
AN
2 2 2 4 5 5
1/2" = 1' - 0"
1'-0"
1/8" /
4" SAN
0' - 0"
4"
S
AN
12' - 0"
2
4
2 2 8
1'-0"
8' - 0"
1/8" /
1/
8" 4" S
1'-0" 7
1/8" / 4" SAN
/ 1 AN
'-0
4" SAN
"
2
4
4' - 0"
5
2
4
1'-0"
1/4" = 1' - 0"
1/8" /
1'-0"
4" SAN
7 1/8" /
4
4" SAN 2
0' - 0"
4 4
3 4
1'-0"
1/8" /
5 4" SAN
1'-0"
2 1/8" /
4" SAN 1'-0"
24' - 0"
1/8" /
4"
4" SAN
S
AN
2
2
16' - 0"
4
4" SAN
2
2
5 2 4 7 7 5
1'-0" 2
1/8" /
1/
8' - 0"
8" 4" S
4" SAN
/ 1 AN
'-0
"
2
1/8" = 1' - 0"
4 5
2
4" SAN 5 2
2 1'-0"
1/8" /
0' - 0"
5
1'-0"
1/8" /
48' - 0"
4" SAN
1
2
32' - 0"
16' - 0"
1/16" = 1' - 0"
0' - 0"
120' - 0"
Drawn FA
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
4
No.
06/25/2019
Date
ISSUE FOR BID
Issue
Drawings are not to be scaled.
0' - 0"
3' - 0"
2' - 0"
2" SAN
2" V
1' - 0"
2" SAN
1" = 1' - 0"
2" V
0' - 0"
2" V
S-1
2"
2" V
V
6' - 0"
2" PD
4" FCO
2" SAN
2"
2" SAN
V
2" V
2" PD
2" SAN
2"
4' - 0"
V
2"
2" V
V
2" SAN
3" V
A N
SA
N
2" SAN
2' - 0"
2" V
2" SAN
2" PD
2"
2"
1/2" = 1' - 0"
V
AN
3" FD-1
4" FCO
2" V
2 1/2" V
2" SAN
4" FCO
S-1
2" V
2"
SA
N
4"
12' - 0"
SA
N
GT-1 4" FCO 3" FD-1
S-2
2" V
4" FD-1 3" SAN
3" V
2" SAN
8' - 0"
WC-2A
2" SAN
L-2A
2" SAN
3" V
2" SAN
3" FD-1
2" V
4" SAN
4" SAN
4' - 0"
S-1
3"
S-1
AN
2" SAN
2 1/2" V
2" V
S
3"
1/4" = 1' - 0"
S-1
0' - 0"
4" SAN
2" V
S-1 4" SAN
EWC-1
2" V
3" V
2" SAN
4" FD-1
2" V
WC-1A
3" FD-1
2" V
U-1
U-1A
2" SAN
2 1/2" V
4" FD-1
24' - 0"
3"
L-1A
2 1/2" V
S-1
4" FD-1 L-1A S-1 4" FCO
L-1 3" FD-1
2" V S-1
2" V
WC-1
16' - 0"
WC-1
2" SAN
S-1
2"
4" FD-1 WC-1A
3"
4"
V
V
4" FD-1
SA
1 1/2" V
2 1/2" S
8' - 0"
AN
S-1
1/8" = 1' - 0"
2" V
S-1
4" SAN
S-1
2"
2" V
P
0' - 0"
D
S-1
2" SAN
2" V
S-1
S-1 CSS-1
4" FD-1
2" V
WC-2A
2" SAN S-1
48' - 0"
L-1A
4" FD-1
2" SAN
S-1 S-1 S-1
4" FD-1 S-1 S-1
2" V
WC-2A
32' - 0"
L-1A
2" SAN
S-1 S-1
2" PD
16' - 0"
S-1 S-1
1/16" = 1' - 0"
0' - 0"
120' - 0"
Drawn FA
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 4 06/25/2019 ISSUE FOR BID
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
3
No.
03/22/2019
Date
ISSUE FOR 25% CD
Issue
Drawings are not to be scaled.
PLUMBING KEYNOTES
0' - 0"
KEY
VALUE KEYNOTE TEXT
1 2" x 4" VENT THRU ROOF.
2 4" x 6" VENT THRU ROOF.
3 2" SANITARY DOWN THRU FLOOR SERVING DENTAL CHAIR. DRAIN OUTLET SHALL BE TRAPPED AND
VENTED. FIELD VERIFY AND COORDINATE WITH DENTAL EQUIPMENT CONTRACTOR.
3' - 0"
1
2' - 0"
1' - 0"
21
/2"
V
2" V
1" = 1' - 0"
0' - 0"
2 1/2" V
S-3
2
6' - 0"
3" V
4' - 0"
3
S-3
3" V
2
3
2 1/2" V
S-3
3 S-3
2' - 0"
2 1/2" V
3
S-3
1/2" = 1' - 0"
V
2 1/2"
21
2 1/2" V
/2"
V
S-3
2" V
0' - 0"
S-1
2 1/2" V
S-1
12' - 0"
2" V
2" V
2" V S-1
2" V
CSS-1
8' - 0"
2" V
1
2"
MB-1 4" V
V
3" FD-1 S-1
S-1
4' - 0"
4" V
S-1
3" V
1/4" = 1' - 0"
3" V
EWC-1
0' - 0"
2" V
3" FD-1 WC-1A
U-1
U-1A
SAN
3" V
3" FD-1
S-1 2 1/2" S-1
L-1
4"
24' - 0"
L-1A
V
S-1
L-1A
L-1
WC-1 S-1
WC-1 S-1
4" V
16' - 0"
WC-1A
2" V
2" V
2
4" SAN
2" V
8' - 0"
3" V
S-1
4" V
1/8" = 1' - 0"
L-1A
2" V
2" V
2" V
0' - 0"
2" V
2" V
3" FD-1
4" V
WC-2A CSS-1
3" FD-1 S-1
S-1
2" V
MB-1 2" V
48' - 0"
S-1
3" FD-1 S-1 S-1
S-1
32' - 0"
S-1
S-1
16' - 0"
S-1
S-1
1/16" = 1' - 0"
0' - 0"
Drawn FA
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
4
No.
06/25/2019
Date
ISSUE FOR BID
Issue
Drawings are not to be scaled.
3 /4 2
"F
0' - 6"
-CW
1" F
0' - 3"
1 -CW
3" = 1' - 0"
3 PLUMBING KEYNOTES
0' - 0"
1" F
-CW
KEY
VALUE KEYNOTE TEXT
1 HOT WATER RETURN BALANCING STATION. REFER TO DETAIL ON SHEET P501 (TYPICAL).
2 1" FILTERED WATER UP THRU FLOOR TO WATER FILTER.
S-2 3 3/4" FILTERED WATER UP THRU FLOOR SERVING DENTAL CHAIR. FIELD VERIFY AND COORDINATE WITH
3 DENTAL EQUIPMENT CONTRACTOR.
3' - 0"
W 11 3 /4
"H /4 " "F
3/4 CW -CW 4 1" COLD WATER DROP SERVING 1" REDUCED PRESSURE ZONE BACKFLOW PREVENTER (RPZ). DRAIN
DISCHARGE OUTLET INDIRECTLY TO OVER FUNNEL DRAIN. PROVIDE AIR GAP. EXTEND 1" COLD WATER TO
EXTERIOR GROUND YARD HYDRANT.
3/4 5 1" COLD WATER DROP SERVING 1" REDUCED PRESSURE ZONE BACKFLOW PREVENTER (RPZ). DRAIN
" HW
WC-2A DISCHARGE OUTLET INDIRECTLY TO OVER MOP BASIN. PROVIDE AIR GAP.
CW
2' - 0"
1 /2" 3
1 1" C
W
L-2A 3/4
" HW 3
/4"
HW
-R
3 /4
"F
1' - 0"
-CW
-R 3
" HW
3/4
" HW
1" = 1' - 0"
3/4
HWRP-1 CW
0' - 0"
/2"
HWRP-1 11
1" C
W
11
/4" 2
HW 1/2"
- R CW W
1" C CW
/2"
6' - 0"
11 HW
2" H W 3/4"
DWBP-1
W 3/ 4" C GYD-1
3/4 S-1
" HW
-R 21
/2 " R
GWH-1 2 1/2" CW CW W-
"H 1
4' - 0"
W W 3/4
1" C 2" CW " H
GWH-1 11
/2 " " CW W 3/4
MTMV-1
2" HW HW 3/4 1" C
S-1
W 1" RPZ
2" C
2' - 0"
3/4 MB-1
"
3/4 HW 3/4" HW S-1
"H /2" CW
W- CW
-R 11 /2"
R HW 1 1 " HW 1 1/2" HW
"
3/4 3/4 11
1/2" = 1' - 0"
2" CW /2 " 4
CW
5 1" RPZ 3/4
3/4 " CW
" HW
0' - 0"
1 -R
3/4 HW
" HW 1 1/2 WC-1A
3/4
" -R
S-1 " CW 3/4 " HW 1
1 " HW 11 3/4
WC-1
3/4 1/2" C -R
1" H
/4 "
CW
"H
W W W WC-1
1" C W
W "H
3/4 " CW
EWC-1 /2
12' - 0"
11
1" CW
11 S-1
/2 "
CW
WC-2A 1
WC-2A 3/4
L-1A " CW
L-1A L-1
GYD-1
8' - 0"
W L-1A
1" C 1 L-1
3/4" HW
W
1" H S-1 L-1A
1 1/2" CW
R
W- 3/4 S-1
"H "
3/4 HW
-R 3/ U-1A
4" H
W 3/4 S-1
" U-1
4' - 0"
CSS-1 CW
NFWH-1
3/4
1/4" = 1' - 0"
" CW S-1 11
3/4 /4 "
" CW
HW
3/4 WC-1A
0' - 0"
S-1 " CW
3/4
S-1 S-1 " HW
W
"H 3/4
C W 3/4 "H
" W-
3/4 R
S-1
S-1
-R
24' - 0"
" HW
1 3/4
S-1
S-1
1" HW 3/4
" HW S-1
1" CW -R 3/
4" H
W 3/4
16' - 0"
" CW 1
" CW
3/4
1 -R
" HW
3/4 S-1
HW 3/4
8' - 0"
" "
3/4 CW
3/4 S-1
"H
W
1/8" = 1' - 0"
3/4
" HW
-R 3/4" HW-R
3/4" HW
0' - 0"
3/4" CW
" CW
3/4
S-1 1 -R
" HW 1
3/4
S-1 " HW
3/4
48' - 0"
-R
" HW
3/4
" HW
3/4
32' - 0"
" CW
3/4
S-1 1
S-1 S-1
S-1
16' - 0"
1/16" = 1' - 0"
0' - 0"
S-1
S-1
120' - 0"
90' - 0"
Drawn FA
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
4
No.
06/25/2019
Date
ISSUE FOR BID
Issue
Drawings are not to be scaled.
1
0' - 6"
1" CW
3/4" HW
3/4" HW-R
0' - 3"
S-4
3" = 1' - 0"
PLUMBING KEYNOTES
0' - 0"
S-3
KEY
S-1 1" BFP-2
3 VALUE KEYNOTE TEXT
WF-1 1 HOT WATER RETURN BALANCING STATION. REFER TO DETAIL ON SHEET P501 (TYPICAL).
2 PROVIDE POINT OF USE DI WATER SYSTEM FOR STERILE LAB 211. PROVIDE 3/4" COLD WATER DROP AND
DUAL CHECK VALVE BACKFLOW PREVENTER. EXTEND AND CONNECT TO DEIONIZED WATER SYSTEM (DI-1).
EXTEND AND CONNECT TO FAUCET. FIELD VERIFY AND COORDINATE WITH DENTAL EQUIPMENT
3' - 0"
S-4
3/4 CONTRACTOR.
" HW
W 3 WATER FILTER (WF-1) LOCATED IN CABINET ABOVE SINK. PROVIDE DUAL CHECK BACKFLOW PREVENTER
1" C 1
UNDER CABINET. EXTEND AND CONNECT TO WATER FILTER.
W HW
1" H W 3/4
"
-R 3/ 4" C
" HW
3/4
2' - 0"
S-3 S-4
W
" F -C 3/4
3/4 " CW
CW
W 3/4"
1' - 0"
S-1 "F
1" H -CW 3/4" HW
3/4" F-CW
W
3/4" CW
0' - 0"
3/4
" HW
-R CW
" S-3 S-4
HW 3/4 3/4
"
" HW
3/4
S-1
EEW-1 3/4
" CW
6' - 0"
" CW
3/4 3/4 S-3
W " HW 1 " HW S-3 S-4
2" C -R 11 DI-1 3/4
W /2 "
"H HW
1 1 /2 2" C 11 3/4
W /2 " 2 "
-R CW HW
" HW
4' - 0"
3/4 3/4
"C
W
3/4
"
CW 1 CW
1 /2" W
1 "H 3/4
3/4 " HW
-R
" HW
3/4
2' - 0"
CSS-1
2" C
W
WC-2A 1" C WC-1A -R MB-1
HW HW
1/2" = 1' - 0"
W W " "
2" C 3/4 3/4
1 1/ 1" H 11 WC-1 1 "C
W S-1
3/4" CW
3/4" HW-R
W /4 "
CW 1 1 /2
L-1A WC-1
0' - 0"
3/4
" HW " HW " CW
-R 3/4 /2
11
/2 " 11
1 1/2" HW
CW NFPH-1
1
3/4" HW-R
1
2" CW
EWC-1
12' - 0"
L-1
L-1A
W 3/4 L-1A
"
1" C CW
S-1
3/4 U-1A
" HW S-1
8' - 0"
CSS-1
3/4 U-1
" HW
-R
L-1
1" C
W S-1 11
/4 "
1" H CW
4' - 0"
W WC-1A
3/4 S-1
" HW
-R 3/4
1 " CW
1/4" = 1' - 0"
W
/ 4" H MB-1 3/4
" CW 3 " HW
3/4 S-1
0' - 0"
S-1 3/4 HW
" "
S-1 HW W 3/4
1 -R
3/ 4" C 1
1" C
W
1" H
W S-1 S-1
3/4
"
24' - 0"
HW
-R 3/4" HW-R
3/4" HW
3/4" CW
3/4
" CW " CW " CW
3/4 3/4
1 3/4 " HW
-R "H 3/4
" HW W W-
R
3/4 4" H
16' - 0"
3/4
" 3/
HW S-1
-R
S-1
8' - 0"
3/4
" HW 1
3/
3/4 4" CW
1/8" = 1' - 0"
"H
3/4 W-
" HW R
1 -R 3/4
"H
0' - 0"
S-1 W 3/4
" CW
S-1
" CW
H W 3/4
4 "
R 3/
W-
48' - 0"
3/ 4" H
1
S-1
32' - 0"
S-1 S-1
S-1
16' - 0"
1/16" = 1' - 0"
S-1
0' - 0"
S-1
120' - 0"
Drawn FA
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
4
No.
06/25/2019
Date
ISSUE FOR BID
Issue
Drawings are not to be scaled.
0' - 0"
3' - 0"
6" RD-1
2' - 0"
1' - 0"
6" RD-1
0' - 0"
CO
1'-0"
1/8" / (2)CO 1'-0"
S F) 1/8" /
(2103 217 SF
)
6" SD 6" SD (2
6' - 0"
CO
S F)
4" RD-1 (1742
6" OSD CO
1'-0"
1/8" / )
742 SF
4" SD (1
4' - 0"
F)
(3)CO 6"
(1742 S S D
4" OSD (23
6" RD-1 38
S F)
(2)CO
2' - 0"
(2)CO
1/
6" 8"
SD /1
( '-0 GCO
1'-0" 6" 20 "
1/8" / OS 86
0' - 0"
S F) D SF
(3845 (0 )
6" S D SF
)
6" RD-1
6" RD-1 SF
)
(2)CO
4' - 0"
1/4" = 1' - 0"
6"
S D
FCO (21
0' - 0"
75
SF 6"
1'-0" )
1/8" / O SD
S F)
(3845
6" SD
1'-0"
1/8" /
24' - 0"
S F)
(2086
6" SD
16' - 0"
1/
8"
6" /1
S D '-
(20 0"
86 FCO
1/ SF
8" )
8' - 0"
6" /1
S D '-
(38 0"
45
SF
)
1/8" = 1' - 0"
1'-0"
1/8" /
S F)
(2086
6" SD
S F)
48' - 0"
(4261
6" SD
1/
GCO 8"
6" /1
1'-0" S '-
1/8" / D
(21 0"
S F) 75
(8106 SF
8" SD )
32' - 0"
16' - 0"
0' - 0"
120' - 0"
Drawn FA
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked FA 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 4 06/25/2019 ISSUE FOR BID
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
3
No.
03/22/2019
Date
ISSUE FOR 25% CD
Issue
Drawings are not to be scaled.
1. THIS SHEET INCLUDES OFFICE STANDARD SYMBOLS AND ABBREVIATION LIST. ALL
1. THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF DEVICES, FIXTURES, SYMBOLS MAY NOT NECESSARILY APPEAR ON THIS PROJECT.
SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION CONDUIT AND EQUIPMENT. CONTRACTOR SHALL FOLLOW THE ARRANGEMENT
SURFACE LIGHT (TYPE DENOTED) WHEREVER FEASIBLE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO 2. ALL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE PROJECT
HALFTONE SYMBOL INDICATES EXISTING VERIFY EXISTING FIELD CONDITIONS AND TO MAKE MINOR MODIFICATIONS TO SPECIFICATIONS AND ALL OTHER DRAWINGS RELATED TO THE PERFORMANCE OF
0' - 6"
POLE MOUNTED LIGHT (TYPE DENOTED) B FIRE ALARM BELL WALL TELEPHONE OUTLET (TYPE DENOTED)
T
CIRCUIT BREAKER PANEL LOCATIONS, ELEVATIONS, ETC. AS MAY BE REQUIRED. THE WORK. THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH
RECESSED LINEAR LIGHT (TYPE DENOTED) DASHED SYMBOL INDICATES REMOVED INFORMATION OUTLET (TYPE DENOTED) CONTRACT DOCUMENTS AND TECHNICAL SPECIFICATIONS BEFORE COMMENCING
S SPEAKER (WALL OR CEILING MT.)
SINGLE RECEPT. POWER OR DISTRIBUTION PANEL 2. PROVIDE FIRESTOPPING FOR ALL OPENINGS THROUGH FIRE RATED ANY WORK. THE PROJECT SPECIFICATIONS AND DRAWINGS FORM THE BASIS OF
STRIP LIGHT (TYPE DENOTED) CONSTRUCTION (WALLS, PARTITIONS AND FLOORS) WITH UL APPROVED MATERIAL.
DUPLEX RECEPT. V FIRE ALARM STROBE (CANDELAS) AC INFORMATION OUTLET ABOVE COUNTER THESE CONTRACT REQUIREMENTS AND INCLUDE THE TYPE AND GRADE OF
FIRE STOPPING SHALL CONFORM TO LOCAL AUTHORITY REQUIREMENTS. MATERIALS TO BE INSTALLED, EQUIPMENT TO BE FURNISHED, AND THE LOCATION
0' - 3"
EMERGENCY BATTERY LIGHT (TYPE DENOTED) SPLIT DUPLEX RECEPT. TRANSFORMER (TYPE DENOTED)
SV FIRE ALARM SPEAKER W/STROBE (CANDELAS) WIRELESS ACCESS POINT PROVIDE PROPER SEALS AND WEATHERPROOF PENETRATIONS THROUGH AND MANNER IN WHICH EQUIPMENT SHALL BE INSTALLED. IN THE EVENT OF A
EXIT SIGN (TYPE DENOTED) ISOLATED GROUND RECEPT (DUPLEX SHOWN) XX-1 MOTOR (SEE SCHEDULE) FOUNDATIONS AND EXTERIOR WALLS FOR ALL RACEWAYS AND CONDUITS CONFLICT BETWEEN THE PROJECT, SPECIFICATIONS AND DRAWINGS ASSUME THE
TELEVISION OUTLET ENTERING THE BUILDING.
3" = 1' - 0"
RECEPT ON EMERGENCY CKT (DUPLEX SHOWN) FIRE ALARM REMOTE ANNUNCIATOR MOST STRINGENT AND/OR COSTLY REQUIREMENT APPLIES UNLESS OTHERWISE
LIGHT FIXTURE ON (EM) LIFE SAFETY BRANCH
COMB. MOTOR STARTER (FUSED) DIRECTED BY THE OWNER AND/OR ENGINEER IN WRITING.
FOURPLEX RECEPT. SD SMOKE DETECTOR (TYPE DENOTED) BELL 3. VERIFY EQUIPMENT PLUG CONFIGURATION BEFORE PURCHASING RECEPTACLES
VS
0' - 0"
D
FLOOR RECEPT. (DUPLEX SHOWN) RECEPTACLES AND OTHER DEVICES WITH ARCHITECTURAL DRAWINGS. CONDITIONS THAT COULD HAVE BEEN REASONABLY DETERMINED BY A
PC PHOTOCELL
CR DC CL ML ES
RECEPT ON DROP CORD (DUPLEX SHOWN) RTS REMOTE TEST/STATUS STATION ELECTRIC STRIKE THOROUGH FIELD INSPECTION. SHOULD FIELD CONDITIONS SIGNIFICANTLY ALTER
J
BUS DUCT WITH PLUG IN DISCONNECT (FUSED) 5. COORDINATE FINAL OUTLET LOCATION WITH ALL TRADES AND
SINGLE POLE SW. THE DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING
J RECEPT ON CORD REEL (DUPLEX SHOWN) S MAGNETIC LOCK FURNITURE/MILLWORK PLACEMENT PRIOR TO ROUGH-IN.
F.A. PULLSTATION (TYPE DENOTED) THE ENGINEER FOR CLARIFICATION AND DIRECTION PRIOR TO BIDDING.
D
DIMMER SWITCH
3' - 0"
OCCUPANCY SENSOR SWITCH H F.A. DOOR HOLDER 6. MOUNTING HEIGHTS ARE TO CENTER OF DEVICE OR EQUIPMENT, UNLESS NOTED
DOOR CONTACTS 4. ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD LISTED
P POWER POLE (OPEN OFFICE STYLE) OTHERWISE.
H
HUMIDISTAT IN PROJECT SPECIFICATIONS OR IN THE CONTRACT. IF NOT LISTED, ALL MATERIAL
VS
J JUNCTION BOX
J
FPPR FIRE PUMP PHASE REVERSAL THE EQUIPMENT AND INSTRUCT THE OWNER'S PERSONNEL IN THE PROPER
A AUTO DOOR OPENER 8. DO NOT ALLOW INSTALLATION OF ANY PIPING, DUCTWORK, OR ANY OTHER NON-
PB PULL BOX FPR OPERATION AND MAINTENANCE.
FIRE PUMP RUN ELECTRICAL SYSTEMS DIRECTLY ABOVE ANY ELECTRICAL PANELS,
R DOOR RELEASE SWITCHBOARDS, OR SIMILAR DISTRIBUTION EQUIPMENT. PROVIDE DEDICATED
FPF FIRE PUMP FAIL 5. AT PROJECT COMPLETION, AS-BUILT DRAWINGS SHALL BE TURNED OVER TO THE
MULTIOUTLET ASSEMBLY (TYPE DENOTED) SPATIAL REQUIREMENTS PER CODE FOR SUCH EQUIPMENT. WIRING SHALL BE
NOTIFICATION APPLIANCE CIRCUIT EXPANDER PUSH BUTTON FOR DOOR RELEASE OWNER REPRESENTATIVE. ALL AS-BUILT DRAWINGS SHALL BE CREATED IN
NAC COPPER TYPE, THHN/THWN FOR INDOOR APPLICATIONS, XHHW FOR WET CURRENT AUTOCAD VERSION AT AN APPROPRIATE SCALE (E.G. EQUAL TO THOSE
FACP CLOCK (TYPE DENOTED) LOCATIONS AND EXTERIOR APPLICATIONS. MINIMUM SIZE OF NO. 12 AWG FOR
1' - 0"
FIRE ALARM/VOICE CONTROL PANEL ON CONSTRUCTION DRAWINGS), OR AT A NOMINAL SCALE OF 1/8"= 1'-0".
LIGHTING AND POWER BRANCH CIRCUITS AND MINIMUM SIZE OF NO 14 AWG FOR
CCTV CCTV CAMERA CONTROL CIRCUITS. ALL WIRING SHALL BE INSTALLED IN RACEWAY UNLESS 6. FURNISH ALL MATERIAL AND EQUIPMENT TO PROVIDE A COMPLETE AND
NOTED OTHERWISE. OPERATIONAL SYSTEM. ALL WORK SHALL BE CONSIDERED NEW UNLESS
NURSE CALL EMERG. STATION
E
SPECIFICALLY NOTED OTHERWISE.
1" = 1' - 0"
NURSE CALL CODE BLUE EMERG. STATION 9. COORDINATE EXACT LOCATIONS AND QUANTITIES OF DUCT-MOUNTED SMOKE
B
NURSE CALL DUTY STATION DETECTORS, WATER FLOW SWITCHES AND TAMPER SWITCHES WITH MECHANICAL 7. ALL INSTALLED WORK SHALL CONFORM TO THE LATEST APPLICABLE CODES,
0' - 0"
D
AND FIRE PROTECTION SHOP DRAWINGS. REQUIREMENTS OF LOCAL UTILITY COMPANIES AND ALL AUTHORITIES HAVING
NURSE CALL STAFF STATION
S
JURISDICTION. IN CASE OF CONFLICTS BETWEEN THESE DRAWINGS AND LOCAL
NURSE CALL SINGLE PATIENT STATION 10. UNLESS NOTED OTHERWISE INDICATED WIRE SIZE FROM PANEL TO ELECTRICAL ORDINANCES, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT
P
2
LOAD FOR 120V 15A AND 20A BRANCH CIRCUITS SHALL BE ADJUSTED BASED ON AND/OR ENGINEER. FOR THE PURPOSE OF BIDDING, THE CONTRACTORS SHALL
NURSE CALL DUAL PATIENT STATION THE CONDUCTOR LENGTH AS FOLLOWS:
1 P
2
ASSUME THE MOST STRINGENT REQUIREMENTS APPLY.
a. LESS THAN 100 FEET USE #12 AWG
N
NURSE CALL DOME LIGHT (2 LAMP)
b. FROM 100 TO 200 FEET, USE #10 AWG 8. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS, FEES, TESTS, AND
c. FROM 200 TO 250 FEET, USE #8 AWG
6' - 0"
12. PROVIDE GFCI TYPE RECEPTACLES LOCATED WITH 6’-0” OF SINKS, WHERE SHOWN CLEARANCES, ROUTING OF MAJOR EQUIPMENT/MATERIAL, ETC. CONTRACTOR TO
ON DRAWINGS AND OTHERWISE REQUIRED BY CODE. ASSUME CEILING SPACE ON EACH FLOOR IS VERY LIMITED AND EXTREMELY
CLOSE COORDINATION IS REQUIRED BY ALL TRADES. THESE DRAWINGS DO NOT
13. CONDUITS SHALL RUN ABOVE SUSPENDED CEILINGS AND CONCEALED IN WALLS ATTEMPT TO SHOW EVERY OFFSET, TRANSITION OR INTERFERENCE THAT MAY BE
WHEREVER POSSIBLE. REQUIRED OR OCCUR. THE CONTRACTOR SHALL INCLUDE IN HIS BID THE LABOR
AND MATERIAL REQUIRED TO COORDINATE AND INSTALL HIS WORK. WHENEVER
14. CONDUIT ROUTING SHOWN ON DRAWINGS IS DIAGRAMMATIC. EXACT ROUTING
2' - 0"
10. COORDINATE THE INSTALLATION OF ALL EQUIPMENT AND MATERIAL WITH ALL
15. PROVIDE ALL PANELBOARDS WITH TYPEWRITTEN CIRCUIT DIRECTORIES. ALL OTHER TRADES. NO ADDITIONAL COMPENSATION SHALL BE GIVEN FOR WORK
CIRCUIT BREAKERS SHALL BE LABELED TO IDENTIFY SYSTEMS OR EQUIPMENT THAT HAS BEEN INSTALLED WITHOUT BEING FULLY COORDINATED WITH ALL
0' - 0"
SERVED. PROVIDE RACEWAYS FOR ALL LOW VOLTAGE TRADES WHERE OTHER TRADES. ALL EQUIPMENT AND MATERIALS INSTALLED IN PLENUM CEILINGS
STRUCTURE IS EXPOSED TO PUBLIC SPACE. SHALL BE APPROVED FOR THE PURPOSE AND ACCEPTABLE TO LOCAL ORDINANCE.
ILLUMINATED "EXIT" SIGNAGE (CHICAGO) 16. PROVIDE MACHINE-PRINTED, PRESSURE SENSITIVE, ABRASION RESISTANT LABEL 11. SCHEDULE AND COORDINATE ALL WORK WITH THE OWNER. CONTRACTOR SHALL
ELECTRICAL ABBREVIATIONS LIST TAPE ON FACE OF WALL SWITCH AND RECEPTACLE DEVICE PLATES TO IDENTIFY TAKE ALL NECESSARY PRECAUTIONS TO PROTECT THE OWNER’S EQUIPMENT.
THE CIRCUIT NUMBER AND PANELBOARD OF ORIGIN. CONFIRM ALL LABELS AND
SINGLE LINE - SINGLE FACE (DIRECTION OF ARROWS AS INDICATED) ROOM NUMBERS WITH OWNER PRIOR TO FINALIZING LABELING AND
1P 1 POLE (2P, 3P, 4P, ETC.) CTR CENTER HT HEIGHT NEMA NATIONAL ELECTRICAL SWBD SWITCHBOARD #XX #XX 12. CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN CLEANUP DURING
DOUBLE LINE - DOUBLE FACE (DIRECTION OF ARROWS AS INDICATED) PROGRAMMING. CONSTRUCTION. SHOULD CLEANUP NOT BE PERFORMED IN A TIMELY,
12' - 0"
LOCATION OF MECHANICAL AND PLUMBING EQUIPMENT WITH MECHANICAL AND IN THAT TRADE. ANY FINISHES THAT ARE DAMAGED DURING THE INSTALLATION OF
AFG ABOVE FINISHED GRADE DN DOWN IG ISOLATED GROUND NTS NOT TO SCALE T-STAT THERMOSTAT 14-1 FIRE ESCAPE PLUMBING TRADES.
AFI ARC FAULT CIRCUIT DPR DAMPER IMC INTERMEDIATE METAL CONDUIT OH OVERHEAD TTC TELEPHONE TERMINAL CABINET THE WORK SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE
#1 FIRE ESCAPE #14 14-2 STAIR
INTERRUPTER DS SAFETY DISCONNECT SWITCH INCAND INCANDESCENT OL OVERLOADS TV TELEVISION ARCHITECT OR OWNER.
14-3 EXIT 19. ALL WORK SHALL CONFORM TO THE CHICAGO BUILDING CODE, INCLUDING NEC
AHU AIR HANDLING UNIT DT DOUBLE THROW IR INFRARED PA PUBLIC ADDRESS TVTC TELEVISION TERMINAL CABINET 2017 WITH CHICAGO AMENDMENTS.
AL ALUMINUM DWG DRAWING I/W INTERLOCK WITH PB PULL BOX OR PUSHBUTTON TYP TYPICAL #2 STAIRS/STAIRWAY #16 FIRE ESCAPE 14. THE CONTRACTOR SHALL NOT DISTURB ANY HAZARDOUS OR CONTAMINATED
ALT ALTERNATE EC ELECTRICAL CONTRACTOR J-BOX JUNCTION BOX PE PNEUMATIC ELECTRIC UC UNDER COUNTER MATERIALS, INCLUDING BUT NOT LIMITED TO ASBESTOS, RADIOACTIVE MATERIAL,
20. ALL WORK SHALL COMPLY WITH IECC 2015 ENERGY CODE REQUIREMENTS. TOXIC SUBSTANCES, PCB’S, ETC, ENCOUNTERED OR SUSPECTED AND SHALL
4' - 0"
AMP AMPERE ELEC ELECTRIC, ELECTRICAL KV KILOVOLT PED PEDESTAL UE UNDERGROUND ELECTRICAL
AMPL AMPLIFIER ELEV ELEVATOR KVA KILOVOLT-AMPERE PF POWER FACTOR UG UNDERGROUND #3 EXIT #17 STAIRS IMMEDIATELY CONTACT THE ARCHITECT. UNLESS SPECIFICALLY INDICATED
21. ALL SINGLE POLE CIRCUITS SHALL BE PROVIDED WITH DEDICATED NEUTRALS. OTHERWISE, THE ARCHITECT AND OWNER ARE NOT AWARE OF THE PRESENCE OF
ANNUN ANNUNCIATOR EM EMERGENCY KVAR KILOVOLT-AMPERE REACTIVE PH PHASE UH UNIT HEATER SHARED NEUTRALS SHALL NOT BE ACCEPTABLE.
APPROX APPROXIMATELY EMS ENERGY MANAGEMENT SYSTEM KW KILOWATT PIV POST INDICATING VALVE UT UNDERGROUND TELEPHONE SUCH MATERIALS AT THE PROJECT SITE OR WITHIN ANY EXISTING BUILDING.
1/4" = 1' - 0"
#4 FIRE ESCAPE #18 EXIT WORK INDICATED ON PROJECT DRAWINGS OR SPECIFICATIONS SHALL NOT BE
AQ-STAT AQUASTAT EMT ELECTRICAL METALLIC TUBING KWH KILOWATT HOUR PNL PANEL UTIL UTILITY 22. ALL TELECOMMUNICATIONS WORK SHALL CONFIRM WITH CCHHS
ARCH ARCHITECT, ARCHITECTURAL EP ELECTRIC PNEUMATIC LOC LOCATE OR LOCATION PP POWER POLE UV UNIT VENTILATOR OR CONSTRUED TO CALL FOR CONTACT OF ANY OF THESE MATERIALS IF
TELECOMMUNICATION STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. ENCOUNTERED OR SUSPECTED.
AS AMP SWITCH EQUIP EQUIPMENT LT LIGHT PR PAIR ULTRAVIOLET #5 STAIR(S)
0' - 0"
BD BOARD FACP FIRE ALARM CONTROL PANEL MCB MAIN CIRCUIT BREAKER RCPT RECEPTACLE W/ WITH
BLDG BUILDING FCU FAN COIL UNIT MCC MOTOR CONTROL CENTER REQD REQUIRED WG WIRE GUARD #8 STAIR(S) #22 FIRE ESCAPE
BMS BUILDING MANAGEMENT SYSTEMFIXT FIXTURE MDC MAIN DISTRIBUTION CENTER RM ROOM WH WATER HEATER 16. PROPERLY RECEIVE, STORE, TRANSPORT AND INSTALL AT PROPER LOCATIONS
C CONDUIT FLR FLOOR MDP MAIN DISTRIBUTION PANEL RSC RIGID STEEL CONDUIT W/O WITHOUT ALL EQUIPMENT AND MATERIALS REQUIRED BY CONTRACT. RESPONSIBILITY FOR
CAB CABINET FLUOR FLUORESCENT MFR MANUFACTURER RTU ROOF TOP UNIT WP WEATHERPROOF #9 EXIT #23 STAIR(S) CARE AND PROTECTION OF EQUIPMENT AGAINST THEFT, INJURY AND DAMAGE
CAT CATALOG FU FUSE MFS MAIN FUSED DISCONNECT SWITCH SC SURFACE CONDUIT XFMR TRANSFORMER FROM ALL CAUSES SHALL REMAIN WITH THE CONTRACTOR UNTIL ACCEPTANCE OF
CATV CABLE TELEVISION FUDS FUSED SAFETY DISCONNECT SWITCH MH MANHOLE SEC SECONDARY XFR TRANSFER THE PROJECT BY THE OWNER. PROTECT FINISHED SURFACES OF ALL EQUIPMENT
#10 FIRE ESCAPE
16' - 0"
CB CIRCUIT BREAKER GA GAUGE MIC MICROPHONE SHT SHEET #24 EXIT FROM DAMAGE BY COVERING OR COATING WITH MATERIAL APPROVED FOR THIS
CCTV CLOSED CIRCUIT TELEVISION GAL GALLON MIN MINIMUM SIM SIMILAR PURPOSE. REPAIR ALL DAMAGE CAUSED BY WORK OF THIS CONTRACT.
CKT CIRCUIT GALV GALVANIZED MISC MISCELLANEOUS S/N SOLID NEUTRAL #11 STAIR(S)
CLG CEILING GC GENERAL CONTRACTOR MLO MAIN LUGS ONLY SPEC SPECIFICATION 17. PROVIDE ALL SUPPORTS, FRAMING ETC. REQUIRED FOR PROPER INSTALLATION
∠ ANGLE
COMB COMBINATION GEN GENERATOR MMS MANUAL MOTOR STARTER SPKR SPEAKER OF CONDUIT, DUCTS, PIPING, PLUMBING, EQUIPMENT, ETC. AND TO PREVENT
@ AT
CMPR COMPRESSOR GFI GROUND FAULT CIRCUIT INTERRUPTER MOA MULTIOUTLET ASSEMBLY SP SPARE SAGGING, VIBRATION AND STRAIN, AND TO PROVIDE FOR EXPANSION AND
▲ DELTA #12 EXIT
CONN CONNECTION GFP GROUND FAULT PROTECTOR MSP MOTOR STARTER PANELBOARD SR SURFACE RACEWAY CONTRACTION. ALL SUPPORTS AND ANCHORS SHALL BE FABRICATED AND
8' - 0"
' FEET
CONST CONSTRUCTION GND GROUND MSBD MAIN SWITCHBOARD SS STAINLESS STEEL INSTALLED FOR APPLICABLE STANDARDS.
" INCHES
CONT CONTINUATION OR CONTINUOUS GRS GALVANIZED RIGID STEEL (CONDUIT) MT MOUNT SSW SELECTOR SWITCH # NUMBER
CONTR CONTRACTOR GYP BD GYPSUM BOARD MT.C EMPTY CONDUIT S/S STOP/START PUSHBUTTONS 18. EQUIPMENT LABELS AND INSTRUCTIONS REGARDING THE APPLICATION AND
Ø PHASE
1/8" = 1' - 0"
CONV CONVECTOR HOA HANDS-OFF-AUTOMATIC SWITCH MTS MANUAL TRANSFER SWITCH STA STATION INSTALLATION OF THE LISTED EQUIPMENT SHALL BE FOLLOWED TO ENSURE THAT
C CENTER LINE
CP CIRCULATING PUMP HORIZ HORIZONTAL MTR MOTOR, MOTORIZED STD STANDARD THE EQUIPMENT IS BEING INSTALLED IN ACCORDANCE WITH THE
P PLATE
CRT CATHODE-RAY TUBE HP HORSEPOWER N.C. NORMALLY CLOSED SURF SURFACE MOUNTED MANUFACTURER'S LISTED INSTRUCTIONS.
0' - 0"
CT CURRENT TRANSFORMER HPF HIGH POWER FACTOR NEC NATIONAL ELECTRICAL CODE SW SWITCH
48' - 0"
32' - 0"
16' - 0"
1/16" = 1' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
C. ALL EXTERIOR BRANCH CIRCUIT CONDUIT SHALL BE DIRECT BURIED 36" BELOW
GRADE.
D. SITE LIGHTING SHALL BE CONTROLLED VIA PHOTOSENSOR & ASTRONOMICAL
CLOCK, ENSURE THAT SENSOR IS MOUNTED FACING NORTH, 2FT ABOVE THE
TV BENCH NORTH PARAPET AND NOT ON THE EAST WALL & BUILDING FACADE AND
LANDSCAPE LIGHTING SHALL BE SHUTOFF BY MIDNIGHT AND 6AM OR BUSINESS
OPENING.
2' - 0"
1
LV
KEYNOTES
2
1 APPROXIMATE LOCATION OF UNDERGROUND COMED VAULT.
1' - 0"
0' - 0"
PC
6' - 0"
4' - 0"
S1
2
ENCASED S2
2
(2) 4" C CONCRETE
1/2" = 1' - 0"
S3
1 S2
APPROXIMATE LOCATION OF APPROXIMATE LOCATION 2
4' - 0"
1EQH1
2 S2
1/4" = 1' - 0"
S3 2
1
2#8,1#8GRD, 1" RGS C.
0' - 0"
3
S3
1
1EQH1
1
24' - 0"
S3
1 S3
1
2#8,1#8GRD, 1" RGS C.
16' - 0"
S3
S2
S3 1
2
1
8' - 0"
S3
1
1/8" = 1' - 0"
S3
1
0' - 0"
S3
1
48' - 0"
S3
1
S3
1 S3 S3 S3
S3 S3 S3 S3 S3
32' - 0"
1 1 1 1 1 1 1 1 S1
2
S2
16' - 0"
BIKE 2
1/16" = 1' - 0"
RACK
0' - 0"
120' - 0"
1
90' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
0' - 0"
F6 F2 F2 F2 F2 F2 F2
F6 F6B DRAWINGS & ELEVATION PRIOR TO ROUGH-IN.
LS LS LS LS LS
5 LS 5 EM:1
5 5 5 5 5 5 C. ALL LIGHTING FIXTURES ON FIRST FLOOR SHALL BE SERVED BY
F6 F6 BRANCH PANELBOARD "1LPL1" IN MAIN ELECTRICAL ROOM 191A.
F2 VS F2 VS F2 VS F2 VS F2 VS OS
5 OS 5 D. WHERE MULTIPLE SWITCHES ARE GROUPED TOGETHER AT A SINGLE
F2
2' - 0"
5 TOILET F4
112A OS 1a 1a STAIR #1
D D OS F6B
ELEV PIT S101
F4 5 F4 PUBLIC CORRIDOR F2A F1
OS F2A F2A F2A PASSENGER
1a 100A
ELEVATOR 1a
1" = 1' - 0"
VS EM:1
LOCKER ROOM F1 P101 PUBLIC CORRIDOR
112 7 VS 7 100A
OS F11
0' - 0"
F6 5 F6 5 7 7
EM:1 WIC INTERVIEW WIC SHARED EM:1 F1
F6 5 MOTHER'S ROOM WP
1.8 109 OFFICE 105 EM:1
107 KEYNOTES
SOCIAL WORKER VS F4
F6 5 F6 5 F6 5 WORK ROOM F9 1 WAITING AREA IS OPEN TO ABOVE.
2 F1 113
100C 3b F1 F4
D
F2 F2A F5
3 1a 1a
EDUCATION ROOM
6' - 0"
1a VS F2A #3
D
3d RECEPTION
114 7
OS F9 100B a
F6 5 F6 5 F6 5 7 WIC OFFICE F4 EM:2
a EM:1 3b OS F4
107A F5
OS F1
ADMIN ASSISTANT 3 F1 1a EM:1
LS FINANCIAL OS #3
COUNSEL 116 3d VESTIBULE
b c d F4
4' - 0"
1a
F1
OS MECH #12 F1 F1 F1 F1 F1 #6
OS OS
119 EM:2 1a 1a 1a
F6A F6A EM:1 a EM:1 EM:2 1a
1/2" = 1' - 0"
F1 CLINIC GENERAL
OR
5 EM:1 F4 1a PUBLIC CORRIDOR WAITING
F4 F4 F4
JC F4 EM:1 F4 7 F4 EM:1 EM:1 100A 100D
1a 1
0' - 0"
F2 F2 F2 F2 F2 F2
F2 F2 OS EM:1
F6A EM:1 1a
F1 EXAM 6 EXAM 6 EM:1 6 6 6
F6A F6A EXAM
ELEC 7 7 126 127 ISOLATION ROOM
OS OS OS OS OS OS 131
119A D F2 128
F6A BLOOD LAB EM:1 #3
EM:1 EM:1 F2 F2 F2 F2 F2
EM:4
8' - 0"
7 122 #3 IT ROOM
3.3 6 6 EM:1 F4 6 6
EM:2 D D D
2e D D D 6
OS 121
F2 F2 #3 EXAM CORRIDOR #21 EXAM CORRIDOR
#12
EM:4 F1 F1 F1 F1 EM:4 F1 EM:3 F1
101B F1 F1 101B
OS OS
7 7 EM:4 EM:3 2e 2e EM:3 2e F1 2e 2e 2e
e e
#9 EM:4
4' - 0"
F1
OS F4 4f F4 4f F4 4f F4 4f F4 4f F4 4f F4 4f F4 4f BARIATRIC EXAM
F1
TOILET TOILET 2e F2 F2 F5 NURSES / MA F5 132
F5 F5
1/4" = 1' - 0"
F1 141C F4 4f
F2 125
STERIL. ROOM F2 F2 gD F1
F2 MEDICINE F5 F5 EM:3 EM:3
F2 EM:3 OS 144 141 f D
EM:3 OS OS F4 4f D
D OS 2e
6 e
4g f,g f,g EM:3
ULTRASOUND 8
4 EM:3 EM:3 OS e D
145 F1 NURSES / MA
OS F4 4f
F2 141B F2 F2
24' - 0"
F2 8
F2 F1
2e OS EXAM
6 F5 F5 F5 F5
8 F2 140 4g 4g 4g F4 4f OS
OS e EM:3 EM:3
F6B #3 CLEAN UTILITY 8 6 6
EM:3 EM:4 EXAM
143 OS D F4 4f F4 4f F4 4f F4 4f F4 4f F4 4f F4 4f F4 4f
F1 #9 133
16' - 0"
F2 F11 6 6 6 6 6 6
OS 6
EM:3 OS OS OS OS OS OS
FREIGHT EXAM
WP ELEVATOR F2 F2 F2 F2 F2
1/8" = 1' - 0"
EM:3 134
F101 F2 F2
6 6 6 6 6 6
ELEV PIT 6
0' - 0"
5
VESTIBULE BULK STORAGE
EXAM EXAM EXAM EXAM EXAM
101 142
139 138 137 136 135
48' - 0"
32' - 0"
16' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
0' - 0"
LS c d f g h j
F4 F4 F4 F4 LS F4 LS LS 7h LS F1A F1A F1B DRAWINGS & ELEVATION PRIOR TO ROUGH-IN.
F4 F4 F4 F4 F4
9 OS 9 9 F4 F4 LS F2 EM:5 5g
D 7a 7a 7c 7f 7h 7k 7k
7c 7f C. ALL LIGHTING FIXTURES ON SECOND FLOOR SHALL BE SERVED BY
ENCLOSED DENTAL F4 BRANCH PANELBOARD "2LPL1" IN ELECTRICAL ROOM 222.
F1A F1B
EXAM b F4 F4 F4 F13 F4 F4 F13 F4 F4 F13 F4 F4 F13 F4 k EM:5
1a F13 D
D D
207 F4 F4 7a 7a 7c 7d 7c 7f 7g 7f 7h 7j 7h 7k 7m 7k D. WHERE MULTIPLE SWITCHES ARE GROUPED TOGETHER AT A SINGLE
7b
2' - 0"
9 9 D
3b LOCATION, ALL SWITCHES SHALL BE MOUNTED UNDER A COMMON
F4 a m F1A F1B
F4 F4 F4 F4 F4 F4 FACEPLATE.
D 3b 5g
1a 1a 1a 1a 1a 1a 1a
DENTAL CORRIDOR #2 5g E. ALL EMERGENCY FIXTURES ON SECOND FLOOR SHALL BE SERVED
DENTAL CORRIDOR #8 F1A F1B
#6 F1 OS a F1 F1 F1 F1 OS a F1 F1A BY BRANCH PANELBOARD "1LSL1" IN MAIN ELECTRICAL ROOM 191A.
F1 200D 200D F1 3b EM:5 5g
EM:6
1.5 F2A F2A
1a EM:5 1a 1a EM:5 1a 1a 1a EM:6
1' - 0"
EM:6
OS STAIR #1 F1A F1B
F4A 1a F4A 1a F4A 1a
D D
ELEVATOR S101 3b 5g
LEAD PHYSICAN 9 9 F7 1 F7 SHAFT PUBLIC CORRIDOR
D
213 LS WORK ROOM F11 F1 200A
F2 F2 F1A F1A F1A F1B
1" = 1' - 0"
EM:5 3 #5 EM:5
11 11 OS 200E 3b 5g
F1 PASSENGER
OS OS F2
0' - 0"
a CLINIC GENERAL 5g
DENTAL OFFICE OS OS b F4A WAITING
OS D
F2A F2A F2A 217 F2A F2 F2 c F5 F1 200C EM:5 5g
b F2 e OS b F1A F1B
VS D EM:5 3
SOCIAL WORKER F1 Df
11 VS 11 11 11 11 RECEPTION 5g
215 9 9 EM:5 g
D
DENTAL STORAGE 200B F1A F1B
4' - 0"
5e F1A
200A F4 F3 F3
LS 5e
F2A F2A 5f 5f
D F1 OS F4 F4 3 F4 F4 F4
F4 EM:5 F1A F1A EM:5
11 EM:1
0' - 0"
CONFERENCE 9 9 F2 EM:5
ROOM EM:5 F1
PUBLIC CORRIDOR OS 6 6 6 6 6
218 IT ROOM F6A EXAM EXAM EXAM 3 EXAM
200A ISOLATION ROOM EXAM
TOILET F4 F6A 226 228 231
LS F2A 223 227 229 230
F2A 224 9 F1
EM:5 F2 OS F2 OS F2 OS OS F2 OS F2 OS
F4 3 EM:5
OS F2 EM:5
9 F4
8' - 0"
9 9 6 6 6 6 6
3.3 #3 EM:6
D D D EM:7 D D D
6 6 F1 F4A #9 EM:8
PROVIDER F4A F4A F4A F4A F4A F4A F4A
STAFFING D OS 4b 4b 4b 4b 4b 4b 4b 4b F1
D
246 2a F5
F2A F2A F2 F5 NURSES / MA F5 F5 F4A
1/4" = 1' - 0"
SUPPORT F2 4c
OS EM:7 4c 241A 4c EM:7 4b 2a
CORRIDOR 8 F2 F2
BARIATRIC EXAM
200H SOILED UTILITY DOCTORS EM:7 EM:7
225
0' - 0"
6
VS F1 245 F4A
6 OS 241C OS
OS 4b
F2 F1
EM:7 OS EM:7 F2 F2 a
J.C. D F5 F5 F4A BARIATRIC EXAM
F2A F2A F2 EM:7 EM:7 b
244 D 4c EM:7 4b EM:7
D 232
8
cD
4 MEDICINE OS
F1 NURSES / MA F4A F2
6 6 CLEAN UTILITY 241
F2
24' - 0"
241B 4b 10
243 8 F1 OS F2
2a F2 OS D 10
F5 F5 F5 F5 F4A EXAM
8 F2
OS 4c 4c EM:7 4c 4b 233
F6 #2 8 EXAM
OS D 240 F4A F4A F4A F4A F4A F4A F4A F4A 2a
EM:7 EM:8 F1 4b 4b 4b 4b 4b 4b 4b 4b
16' - 0"
STAIR #2 F1 ELEVATOR OS D D D D D D
F2 F2 F2 F2 F2 F2 F2
S102 SHAFT
8' - 0"
10 10 10 10 10 10 10
F6 F11
2a OS OS OS OS OS OS
EM:7
2a SUPPORT
CORRIDOR
1/8" = 1' - 0"
WP FREIGHT
200H F2 F2 F2 F2 F2 F2 F2
ELEVATOR 10
F6 10 10 10 10 10 10
F101
F10
0' - 0"
5 EM:7 2
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
TRIAGE
0' - 3"
S
F
O
1H
N
9
5
0
.8
1 J J J J J 18 J 20 J
12 12 14 16 18 22
12 12 WIC OFFICE N. RIVERA OFFICE GFI
0' - 0"
W
la
t
n
D
e g
17
t
ek1A
B
ra
87 ek1A
B
ra
87 ek1A
B
ra
87
GFI
ecR
t
p10
6 ecR
t
p10
6
110 108 WIC OFFICE
14 14 106 16
12 14
7rkeA
a
18 B
7rkeA
a
18 B
7rkeA
a
18 B
GFI
16 16 18 18 A. SEE ARCHITECTURAL DRAWINGS FOR MOUNTING OF ELECTRICAL
MOTORIZED BREAK AREA 18 65
J 12 20 22 DEVICES. ALL LOCATIONS SHALL BE CONFIRMED WITH ARCHITECT
SHADE 111 65
PRIOR TO ROUGH-IN.
14 14 16 18 20
8 2RPL2 24
E
m
a
x
10
3' - 0"
J
109 PASSENGER
12 112A D. ALL PLUMBING AND MECHANICAL EQUIPMENT REFER TO ELECTRICAL
GFI 26 ELEVATOR MOTOR WIRING SCHEDULE FOR INFORMATION.
28 28
2' - 0"
ESP-1 P101
12
J
WIC SHARED E. ALL RECEPTACLES SHALL BE MOUNTED VERTICALLY EXCEPT ABOVE
28 STAIR #1
OFFICE COUNTERTOPS WHERE THEY SHALL BE MOUNTED HORIZONTALLY.
26
4
6
0
V
2
H
T
R
O
N
1D
F
.−
C
R
6
D
V
5
PN
O
.A
1H
F
0B
S101
26 107 MOTHER'S ROOM ELEV PIT
LOCKER ROOM 12 F. ALL RECEPTACLES SHALL BE WIRED TO BRANCH PANELBOARD
FURN 105
WP
GFI
112 12 28 "1RPL1" UNLESS NOTED OTHERWISE. REFER TO DRAWINGS E-802,
&
im 6
D a
=’c\5G
A
T
.C
4
I
O
T
N
H
3
6
0
V
R
D
4
1.−F
0.N
6
4
−FO
H
A
T
C
D
B
12&
"R
5
P U
V
a
’IrL \pK
edcS =W
fo
s:t E
Y
_ ?G
ljh
u
FEED 26 26 28 CUH-1-1
CUH 1-1
66
N
O
T
C
E
D
1F
P
0 M
.H
B
4
S
5
2
1
H
N
C
G
0
O L2
4
7
9
TR
1.8 E-803, AND E-804 FOR PANEL SCHEDULES.
1' - 0"
J GFI
W
N
H
9
D
F
S
P
2
0O
14
Y R
K
6
4
.E F
S
P
2 N
H
9
D
F
0
2O
E
14
S
P
6
0 N
A
H
C
R
D
B
.4
−F"V
3
L O
T
15
\_ K
U
E
Y
a
’P
pIro ifW
=&
G
leSt :m
jdcs?h D
u ’a A
6
=c\4&
C
.5G
IT
FACP G. ALL DEDICATED CIRCUITS SHALL BE PROVIDED WITH DEDICATED
AC J FURN J
SOCIAL WORKER
H
S
P
M
812
N
5
B
F
O
.0
C
T
E
D
113 Wn
0
7
g
a
it
1
32 32 38 PUBLIC CORRIDOR
1" = 1' - 0"
0
7
F
3
−5
1A
D
N
H
.B
O
b’C
&
4
P
T
=cR
o
\dsa
h
2
E
"pieIS
L
t
u
f:lV
r?m
U
Y
K
G
jW
_ c’4
.2
b&
C
\T
IA
D
=G
5
S
S
0
Y
W
.H
D
O
1N
S
R
K
5
3
4
F
0
P
N
T
RN
H
2
7
0O
.D
14
V
3 F
−
R
V
C
4
H
2
P
D
O
N
F
10
.A
B
114 H
S
P
M
812
N
5
B
F
O
.0
C
T
E
D
WIC OFFICE AC
J 42 30 30 FEED 38
107A 34 I. ALL RECEPTACLES SHALL BE HOSPITAL GRADE. IN ADDITION, ALL
MOTORIZED J RECEPTION 13 VESTIBULE
RECEPTACLES IN AREAS ACCESSIBLE TO CHILDREN SHALL BE
42 100
N
O
H
A
C
1.R
D
B
F
P
0 4
V
2 T
R
V
3N
H
2
7
0O
.D
14F
−
SHADE
A
0
W
T
S
L
1. 3
0
N
4
8
L
C
B
G
2
S
0
Y
W
.H
D
O
1N
S
R
K
5
3
4
F
0
P
N
0
7
F
3
−5
1A
D
N
H
.B
O
b’C
&
4
P
T
=cR
o
\dsa
h
2
E
"pieIS
L
t
u
f:lV
r?m
U
Y
K
G
jW
_ c’4
.2
b&
C
\T
IA
D
=G
5
S R
V
C
4
H
2
P
D
O
N
F
10
.A
B
TAMPER RESISTANT.
12 34
N
O
T
C
1X
E
D
P
0
8B
S
2M
H
F
.5
SHEET E-606 42 FINANCIAL
CLNG 38
G
C
N
H
0
1 TR
9
7
4
O L2
50 COUNSEL 36 J. ALL BATHROOM FAUCETS, TOILET AND URINAL FLUSH VALVES WILL
15
10
HO
T
P sdL E
rie.M L
A
N
T
C
N
O
A
H
T
R
6
D
B
F
S
3
0C
.VL H
1W
M T
50 GFI 115 N
O
H
A
C
1.R
D
B
F
P
0 4
V
2 T
RN
H
14
V
32
7
0O
.D
F
−
BE ELECTRIC.
42 36
S
0
Y
W
.D
H
N
O
1
S
R
K
4
3
8F
0
P
N
0
7
F
3
−1N
A
D
5
H
&
B
.O
P
t
4
\T
dcC
a
pb’s2
o
E
=R
IL
ih
"eu
?fS
:m
U
lV
K
rY
jG
W
_ 4
.b&
’C
c2
T
\A
ID
=S
5
G R
V
C
4
H
2
P
D
O
N
F
10
.A
B
116 34
TV
6' - 0"
38
N
O
T
C
X
E
D
B
S
P
2
0
8M
H
F
15
.
0N
1O
H
D
4
SC
Z
5
.L
6
0 N
O
A
H
C
R
D
B
.4
−F3
LIT
"PVK
r5 1E
U
o
\’ptY if=W
&
G
leS
a
_ jdcs:m
h
u 6 &
=A
C
’.D
? \4
a 5 G
cIT
6
0
−F
V
H
T
R
N
D
3
.O
14 0
A
N
D
C
O
B
V
H
R
6
1P
.F
5
15
UH-1-1 50 FP-1 50 40 38 1M
N
O
T
C
E
D
P
2
0H
.B
S
5
8F
40 38 1M
N
O
T
C
E
D
P
2
0H
.B
S
5
8F
1M
N
O
T
C
E
D
P
2
0H
S
5B
F
.8
CUH 1-2
FIRE PUMP METER GFI GFI 36 34
2.5 MECH
B-1
54
54
KEYNOTES
F
3T
−0
7 N
1O
H
VR
.D
4
2
D
N
B
0
A
C
O
H
P
F
1.R
4
2
V
119 PUBLIC CORRIDOR 72" AFF
4' - 0"
J
B-2 100A 36
50 PFS-1 44 44 SHADE 2 TYPICAL EXAM ROOM RECEPTACLE LAYOUT AND HEIGHTS. REFEF TO INTERIOR
GWH-1 CLINIC GENERAL
GFI
J J PUBLIC CORRIDOR WAITING MEDICAL ENLARGED PLANS & ELEVATIONS - EXAM RM ON SHEET A8-2.
GFI
50
HWP-1 TOILET-W 100A 100D 3 PROVIDE A RECESSED CONCRETE (6) GANG "EFB6S-OG" FLOOR BOX EVOLUTION
54
J
GWH-1 118 TOILET-M MOTORIZED SERIES WITH FURNITURE FEED COVER ASSEMBLY "FPFFTCBZ".
GFI HWP-2 SHADE 4 PROVIDE SWITCH TO CONTROL PLUMBING FIXTURES AND SOLENOID VALVE IN
117
50
2' - 0"
TOILET 123.
JC Fire Pump Controller 44 44 44 44 19 54
19 19 19 GFI 19 19 GFI GFI 19 19 GFI 19 19 19
1C
G
2
H
0
5
O
N
9
3
.E
S
R
J
1LSL1 PRE-ACT J J J J J J 54
INVERTER GFI J J J J 54 54 SHADE
1/2" = 1' - 0"
50 E
m
x
a
3 52
1LPL1 37 78 76 E
x
a
m
49 57 74 75" AFF
Fire Alarm NAC Panel EM:11 IT ROOM 37 GFI EXAM
J
GFI
0' - 0"
J
37 76 49 47 57 51
GFI
2
GFI
122 EXAM
W 1w
0 C
n
ivert
I
W 1w
0 C
n
ivert
I
GFI GFI
GFI
GFI
DP-01 49
GFI
E-501 78 76 57
ELEC 27 52 35 EXAM 47 51
EXAM 74 2 59 42" AFF
131
GFI
126 45
GFI
MDP 37 130
GFI
119A 49
GFI
76
GFI
3 78 76 74 MOTORIZED SHADE
J
27 37 37 37 ISOLATION ROOM 47 EXAM 51 57 74 59
Dl 1g
W
a
en
t 7
t
Dl 1g
W
a
en
t 7
t
3.3 E-501 35 33 128 45 60" AFF
52 77 129 48 55
16" AFF
DW
a
en
t 7
1g
l t
12' - 0"
E
m
a
x E
m
a
x
GFI E
xa
m E
a
xm
EXAM CORRIDOR 29
E
m
a
x
21
SHADE GFI 163 EXAM CORRIDOR
EUH-1-1 15 VAV-1-22 101B
J 52 52 27 101B 42" AFF 60" AFF 29 MOTORIZED
J
25 23 GFI
4 SHADE
FURN
J
J
FEED 39
8' - 0"
P 72 17 72 17 72 17
ecR 6
p10
t
79 13 15 61 75 75 39
TOILET
J
J
TOILET 72 16 72 16
GFI
72 16 NURSES / MA
145A GFI GFI 123 SOILED UTILITY TREATMENT NURSES / MA 60" AFF
79 79 15 124 125 P 141A P
GFI 141A 3 J J
ULTRASOUND 79 15
J
BARIATRIC EXAM
eR 6
p10
ct
13 (TYP.)
cefiO
10 iceO
10 f
J
61 61 69 69 SHADE
4' - 0"
J
73 17 6
61 18 19
eR
ct 6
p10
SHADE STERIL. ROOM GFI 61 141 141C GFI GFI
15 GFI 69 69 39
144 1RPL2 1RPL2 1RPL2
x
E
a
m
1/4" = 1' - 0"
4 28 26 24 18 19
eR
ct 6
p10
x
E
a
m
21 21 69 69 31
SUPPORT 6
71 GFI EXAM GFI GFI GFI
ecR
t 6
p10
71 71 79 CORRIDOR 31 EXAM
0' - 0"
17 140 21
MOTORIZED 79 163 NURSES / MA 3 3 31
J
GFI
79 17
SHADE 21 141B (TYP.) 31
143 141B 31
19
GFI
17 17 FURN 63 22 63 22 63 22 63 20 63 20 63 20 3
J
STAIR #2 19 FEED J 31 31 MOTORIZED
J
S102 P SHADE
SCSO-1
SUPPORT CORRIDOR EXAM CORRIDOR EXAM CORRIDOR 6 21 21
24' - 0"
J
f1G
O ceC
−i0
O C
B
−0
icf1e2
E
x
a
m
E
x
a
m
SHADE
E
m
x
a
x
E
a
m
11
x
E
a
m
E
m
x
a
70 46 56 62 9
6 ESP-1 6 4 60 68 58 53 41
VESTIBULE 4 2 64 53
68 43
E
m
a
x
41
E
m
a
x
70 11
GFI
GFI
GFI
60 58
16' - 0"
101
GFI
GFI
GFI GFI
BULK STORAGE 56
CUH 1-3 142 4 4
GFI
GFI
GFI
ELEV PIT 53
GFI
GFI
4 60 2 68 64 58 64 53 53 41 43
2 68 43
GFI
WP
iO 1G
cfB −2
C
e0
68 GFI
67 GFI
GFI 68 GFI GFI GFI
4 43
5 4 2 2 68 E
m
a
x
64 53 53
E
m
a
x
43
J J J J J
8' - 0"
E
m
a
x
EXAM
E
m
a
x
F101
0' - 0"
48' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
0' - 0"
WT
S
E WT
S
E WT
S
E WT
S
E WT
S
E WT
E
S
1t
0
p6
ecR
10
t
6
epcR
10
6
pt
ecR
XRAY
XRAY
XRAY
XRAY
MOTORIZED 207 MOTORIZED MOTORIZED MOTORIZED MOTORIZED MOTORIZED MOTORIZED MOTORIZED
SHADE SHADE DEVICES. ALL LOCATIONS SHALL BE CONFIRMED WITH ARCHITECT
SHADE SHADE SHADE SHADE SHADE SHADE
J J J J
PRIOR TO ROUGH-IN.
J J J 28 J
2 28
1 5 19 19 21 21 J BUILDING SIGN
3' - 0"
5 CLINIC GENERAL B. PROVIDE FIRE STOPPING AT ALL FIRE RATED WALL AND PARTITIONS.
28 28 19 19 21 6
5 4 27 4 WAITING
4 28 27 27 PAN X-RAY
7 J J J J J J J J J J 200C C. COORDINATE MOTOR EQUIPMENT WITH MECHANICAL DRAWINGS FOR
J (TYP) (TYP) (TYP) 201 EXACT LOCATION.
XRAY 27
J
J J J J
3 60"AFF 21
MOTORIZED J 5 D. ALL PLUMBING AND MECHANICAL EQUIPMENT REFER TO ELECTRICAL
MOTOR WIRING SCHEDULE FOR INFORMATION.
2' - 0"
SHADE 2 2
GFI 12 12 3 50 50 50 21
57 J (TYP) (TYP) 3 E. ALL RECEPTACLES SHALL BE MOUNTED VERTICALLY EXCEPT ABOVE
5 J J (TYP) J J J COUNTERTOPS WHERE THEY SHALL BE MOUNTED HORIZONTALLY.
Wt
1n
0
7
g
a
i
W7
g
a
t
1n
0
i
(TYP)
DENTAL CORRIDOR DENTAL CORRIDOR
57 57 F. ALL RECEPTACLES SHALL BE WIRED TO BRANCH PANELBOARD
200D 31 200D
1.5 21 "2RPL1" UNLESS NOTED OTHERWISE. REFER TO DRAWINGS E-802,
PASS ELEV DISC
1' - 0"
NEUTRAL.
SHADE 57 STAFF CORRIDOR PASS ELEV
M
0
1H
U
8
.
1" = 1' - 0"
0
1H
U
M
8
.
1.8 212
31 25 RECEPTACLES IN AREAS ACCESSIBLE TO CHILDREN SHALL BE
CLINIC MANAGER 35 35 TAMPER RESISTANT.
214 57 33 35 72" AFF
20
1−C
G
2 WORK ROOM
16 31 33 34 J. FIELD COORDINATE PASSENGER AND FREIGHT ELEVATOR
16 16 200E
MOTORIZED REQUIREMENTS AND EXACT LOCATION OF EQUIPMENT WITH
SHADE
J
FURN FEED 31
INSTALLING CONTARCTOR AND THE ARCHITECT/OWNER'S
6' - 0"
20
T
E
N
O
0
C
P
D
2
1M
5
H
S
8
.B
F
1−C
G
M
0
1H
U
8
.
16 J
34 REPRESTATIVE PRIOR TO ROUGH IN AND ADJUST ACCORDINGLY.
18 18 1B
2
8
X
P
S
5
H
T
N
C
E
0
D
O
.F
M T
D
O
N
C
P
E
0
8
1X
B
2
S
.5
H
M
F
18 18 T
N
P
0
C
E
D
O
2
8
S
X
B
15
F
H
M
.
18 18 CLINIC GENERAL
WAITING K. ELEVATOR CABS SHALL HAVE A 4 HOUR RATED BATTERY LIGHTS,
C
o
n
18
f5
SOCIAL WORKER DENTAL SOILED RECEPTION
20
1−C
G
UTILITY 200B 200C PER CHICAGO BUILDING CODE 18-27-700.10.
E
N
T
P
C
D
O
M
0
S
12
H
5
.8
F
B
215 16 34
16 16 DENTAL OFFICE DENTAL STORAGE 208
30 L. PROVIDE DISCONNECTING MEANS PER CHICAGO ELECTRICAL CODE,
0
1H
U
M
8
.
217 209
4' - 0"
J
MOTORIZED 30 22 ARTICLE 110. 25.
1−C
G
SHADE 55 55 30 J.C. 4
FURN FEED 219 M. ALL BATHROOM FAUCETS, TOILET AND URINAL FLUSH VALVES WILL
55 55 STAFF CORRIDOR 4 22 BE ELECTRIC.
1−C
G
30 30 30 30 GFI 72" AFF
MOTORIZED J 200F J 26
55 22
SHADE 55 N
H
9
D
F
2W
O
E
Y
14
S
P
0 R
K
4
F
. S
P
7
2
M
1H
0U
8
.
35 35 35
2.5
2' - 0"
MOTORIZED
PSYCHOLOGIST PASS ELEV DISC PUBLIC CORRIDOR 26 J
SHADE KEYNOTES
OFFICE 200A PUBLIC CORRIDOR
ELEV CAB LIGHTING AND 1 26
216 200A MOTORIZED 1 PROVIDE 120V CIRCUIT FOR WATER FOUNTAIN.
RECEPTACLES 9 9 26 J
55
1/2" = 1' - 0"
SHADE 2 PROVIDE (1) ONE 3/4" EMPTY CONDUIT FOR CABINET TO CONSOLE.
J J
TV TOILET-M 3 PROVIDE (1) ONE 2" STUB-UP CONDUIT AT PATIENT CHAIR TO MEDICAL CABINET.
MOTORIZED J 2 60" AFF TOILET-W COORDINATE WITH MEDICAL MANUFACTURER FOR EXACT LOCATION OF
220
0' - 0"
49
1−C
G
E
x
a
m
x
E
a
m
49 CLNG
2EQH1 GFI
218 GFI GFI GFI 200A GFI GFI
49 2 52 52 42 59
2 38 51 38 52 54 40 44 40
E-502 53 54 54 59 59
GFI
EXAM
GFI
GFI
MOTORIZED 2 TOILET
GFI
J
GFI
EXAM
GFI
SHADE 227 42 EXAM 70
224 226 44 67
76 53
GFI
228 J MOTORIZED
GFI
GFI
GFI
GFI
GFI
3 IT ROOM 51 54 40
49 74 74 74 51 38
52 42 53 54 59 59 59 SHADE
8' - 0"
E-502 223 52 44
G
1−C
2 J J
3.3 J 64 76 66 22
70 61 67
T
P
C
E
D
O
N
0
1F
.H
4
2
M
5
S
B
MOTORIZED 22
15 15 EXAM CORRIDOR
SHADE 15 VAV-2-23 22 J MOTORIZED
G
1−C
1 SUPPORT CORRIDOR 200G SCST-02
J 1
15 200H 22 EXAM CORRIDOR 24 24 SHADE
MOTORIZED
T
P
C
E
D
O
N
0
1F
.H
4
2
M
5
S
B
FUNITURE FEED 200G SCST-01
4' - 0"
SHADE 1 15
J
1 5 J
15 22 11 43 46 8 8
P
GFI
45
eR
ct 6
p10
N
O
T
C
E
D
P M
.H
1F
0 B
4
S
5
2
x
E
a
m
23 (TYP.) 46
PROVIDER SOILED UTILITY 45 8 45 8 45 8 37 10 37 10 37 10
1/4" = 1' - 0"
1 BARIATRIC EXAM 43
1 STAFFING 245 NURSES / MA BARIATRIC EXAM
23 225 4 241A P P
246 232
N
O
T
C
E
D
P M
.H
1F
0 B
4
S
5
2
GFI
GFI
J J
eR 6
p10
ct
Dl 1g
W
a
en
t 7
t
65 46
0' - 0"
1 11 23 23 14
36 12 14 8 J
1 MOTORIZED
GFI
36 23 GFI MEDICINE 14 41 39 SHADE
MOTORIZED J 3
N
O
T
C
E
D
P M
.H
1F
0 B
4
S
5
2
T
P
C
E
D
O
N
0
1F
.H
4
2
M
5
S
B
SHADE
C
C
fn
o 5
18
fn
o 5
18
23 41 39 8 8
UPS
14
M
N
O
T
C
E
D
P
0 H
1.B
4
F
S
5
2
N
P
0
C
E
D
O
T
M
1.B
H
F
S
2
4
5
4 6 14 12
eR
ct 6
p10
3
x
E
a
m
24 14 56 56
36 11 24 24 41 39
24' - 0"
24 EXAM EXAM
72 56
GFI
SHADE CLEAN UTILITY 18
240 68 233
GFI
243 47 47 18 47 18 47 16 32 16 32 16 32 4
24
GFI
72 56 56
STAIR #2 24
J
SUPPORT 11 68 5 J
56 56 J MOTORIZED
S102 P SHADE
CORRIDOR (TYP.)
16' - 0"
FUNITURE FEED
200H
EXAM CORRIDOR EXAM CORRIDOR 22 24
22 FREIGHT ELEV DISC 200G 22 200G MOTORIZED
SCST-01 22 J
SHADE
E
x
a
m
75 73 69 62 71 63
8' - 0"
60 58 58 69 20 17 29 48
ELEV CAB LIGHTING AND 75 60 73 20 10 71 13
FREIGHT ELEV 29
GFI
E
m
a
x
17
E
m
a
x
GFI
GFI
GFI
GFI
GFI
RECEPTACLES EXAM EXAM
20 20 EXAM
GFI
60 60 239 GFI
EXAM 29 29 235 48
GFI
GFI
1/8" = 1' - 0"
FREIGHT
GFI
GFI
BULK STORAGE 58 236 17 10 234
AC-S102 ELEVATOR 60 58 58 10 13 48 13
242 GFI EXAM 20 29
F101 GFI GFI 20 237 GFI GFI GFI
0' - 0"
5 60 58 E
m
a
x
10 29
E
m
a
x
13 13
J J J J J J
lW
a
n
et 7
D 1g
t
60 20 29
E
m
a
x
58 10
E
m
a
x
MOTORIZED EXAM
MOTORIZED MOTORIZED MOTORIZED MOTORIZED MOTORIZED
SHADE 238 SHADE SHADE SHADE SHADE SHADE
48' - 0"
32' - 0"
16' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
BOTH ARE MACHINE ROOM-LESS AND ARE FED FROM PANEL 2EQH1 IN 2ND FLOOR
ELECTRICAL CLOSET. REFER TO ELECTRICAL RISER DIAGRAM ON SHEET E-901
FOR MORE DETAILS. REFER TO DRAWINGS E-802, E-803, AND E-804 FOR PANEL
SCHEDULES.
2' - 0"
WP
GFI
2RPL2-1
ACCU-3
1.5 1.5
1' - 0"
ACCU-5
EF-3
1" = 1' - 0"
GFI
WP
EF-1 EF-2 2RPL2-1
0' - 0"
2RPL2-1
WP
1.8 1.8
GFI
WP GFI
2RPL2-1
2 2
TEF-1
EF-5 EF-119
6' - 0"
EF-4 KEYNOTES
F12 1 PROVIDE 2" CONDUIT FOR FUTURE SOLAR PANEL USE. CONDUIT SHALL
13 TERMINATE IN MAIN ELECTRICAL ROOM. CONTRACTOR SHALL ENSURE CONDUIT IS
CAPPED AND SECURED FOR FUTURE USE, INCLUDE PULL STRING.
4' - 0"
F12 F12
13 13
2.5 2.5
2' - 0"
1/2" = 1' - 0"
0' - 0"
RTU-1
RTU-1
ACCU-1 2RPL2-2 WP
GFI
F12
F12 RTU-2
3 13
3 ACCU-2 RTU-2
12' - 0"
2RPL2-2 WP
GFI
ACCU-4
8' - 0"
3.3 3.3
F12
13
WP
4' - 0"
1/4" = 1' - 0"
1
0' - 0"
4 4
24' - 0"
16' - 0"
8' - 0"
1/8" = 1' - 0"
0' - 0"
5 5
48' - 0"
32' - 0"
16' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
0' - 0"
S
F
O
1H
N
9
5
0
.8
1
CC
ASSOCIATED AUDIBLE LEVELS WITH AMBIENT NOISE IN ALL MECHANICAL SPACES.
3' - 0"
60"
TV
WIC OFFICE WIC OFFICE 42" SOUND LEVELS SHALL COMPLY WITH NFPA 72 REQUIREMENTS.
D
en
t
W
a
l 1g
t
7
ek1A
B
ra
87 ek1A
B
ra
87 ek1A
B
ra
87
7rkeA
a
18 B
7rkeA
a
18 B
7rkeA
a
18 B
BREAK AREA WIC OFFICE TRIAGE D SEE FIRE ALARM ZONE SCHEDULE FOR INITIATING ZONES AND SIGNAL CIRCUITS.
106 E MAXIMUM NUMBER OF 4 INFORMATION OUTLET LOCATIONS PER CONDUIT HOME
2' - 0"
TOILET 100A
E G ALL COMMUNICATIONS CABLES SHALL BE INSTALLED IN CONDUIT AND
112A SV V V TERMINATE BACK TO TELECOMMUNICATION CLOSET. NO FREE-AIR LOW VOLTAGE
PASSENGER
S
CABLING SHALL BE ALLOWED.
V WIC SHARED WAP ELEVATOR VSS
CR WAP OFFICE WF
1" = 1' - 0"
P101 STAIR #1
O
4
T
6
0
N
V
H
2
R
1D
.F
−
N
O
H
A
C
R
6
D
B
1.V
0 F
5
P
LOCKER ROOM 107 S101
SV MOTHER'S ROOM
D PIT SD
0' - 0"
&
im 6
D a
=’c\5G
A
T
.C
4
I
O
T
N
H
3
6
0
V
R
D
4
1.−F
0.N
6
4
−FO
H
A
T
C
D
B
12&
"R
5
P U
V
a
’IrL \pK
edcS =W
fo
s:t E
Y
_ ?G
ljh
u
109 N
O
T
C
E
D
1F
P
0 M
.H
B
4
S
5
2
SHAFT
1
H
N
C
G
0
O L2
4
7
9
TR
1.8
CC
1 CONDUITS STUBS FROM BELOW GRADE SHALL EXTEND 4 INCHES ABOVE THE
TV
W
N
H
9
D
Y
F
S
P
2
0O
14 R
K
6
4
.E F
S
P
2 N
H
9
D
F
0
2O
E
14
S
P
NURSE CALL V WP
6
−F
0 N
A
H
C
R
D
B
.4
"V
3
L O
T
15
\_ K
U
E
Y =&
G
leS
a
’P
pIro ifW
t :m
jdcs?h D
u ’a A
6
=c\4&
C
.5G
IT
A FACP A FINISHED FLOOR.
TIME CLOCK+48" CONSOLE
CCT
A 2 UNUSED ENTRANCE CONDUITS SHALL BE CAPPED AND INSTALLED WITH PULL
H
S
P
M
812
N
5
B
F
O
.0
C
T
E
D
V
2 F FURNITURE SD STRING
D4 FROM SECURITY PANEL TO PEDESTAL
Wn
0
7
g
a
it
1
Wg
17
0
t
n
a
i W7
g
a
t
1n
0
i
N
O
H
A
C
D
B
F
0 R
4
V
P
1.2 F
3H
T
RN
14
−0
7 O
D
.V
2
60"
H
W
O
N
1D
S
0
Y
.
4
0
P
5
N
3
S
R
K
F
0
7
F
3
−5
1A
D
N
H
.B
O
b’C
&
4
P
T
=cR
o
\dsa
h
2
E
"pieIS
L
t
u
f:lV
r?m
U
Y
K
G
jW
_ c’4
.2
b&
C
\T
IA
D
=G
5
S D
N
B
0
A
C
O
H
P
F
1.R
4
2
V
T H
S
P
M
812
N
5
B
F
O
.0
C
T
E
D
J
RECEPTION
100B F WAP VESTIBULE
SV WORK ROOM D4
WAP 100
100C N
O
H
A
C
1.R
D
B
F
P
0 4
V
2 F
3H
T
RN
14
−0
7 2O
D
.V
CCTV A.8
A
0
W
T
S
L
1. 3
0
N
4
8
L
C
B
G
2
H
W
O
N
1D
S
0
Y
.
4
0
P
5
N
3
S
R
K
F
0
7
F
3
−5
1A
D
N
H
.B
O
b’C
&
4
P
T
=cR
o
\dsa
h
2
E
"pieIS
L
t
u
f:lV
r?m
U
Y
K
G
jW
_ c’4
.2
b&
C
\T
IA
D
=G
5
S D
N
B
0
A
C
O
H
P
F
1.R
4
2
V
H
S
M
P
2
1F
N
85
B
O
.0
C
T
D
E
SV
N
O
T
C
1X
E
D
P
0
8B
S
2M
H
F
.5
V F S
G
C
N
H
0
1 TR
9
7
4
O L2
SEE ELEVATIONS ON E-606 WAP D4
4' - 0"
10
HO
T
P sdL E
rie.M L
A
N
T
C
N
O
A
H
T
R
6
D
B
F
S
3
01W
M
C
.VL H
T
N
O
H
A
C
1.R
D
B
F
P
0 4
V
2 F
3H
T
RN
14
−0
7 O
D
.V
2
H
W
O
N
D
1.0
S
Y
0
4
P
3
8S
R
K
N
F
0
7
F
3
−1N
A
D
5
H
&
B
.O
P
t
4
\T
dcC
a
pb’s2
o
E
=R
IL
ih
"eu
?fS
:m
U
lV
K
rY
jG
W
_ 4
.b&
’C
c2
T
\A
ID
=S
5
G D
N
B
0
A
C
O
H
P
F
1.R
4
2
V
N
O
T
C
X
E
D
B
S
P
2
0
8M
H
F
15
.
FEED
0N
1O
H
D
4
SC
Z
5
.L
116
6
0 N
O
A
H
C
R
D
B
.4
−F3
LIT
"PVK
r5 1E
U
o
\’ptY if=W
&
G
leS
a
_ jdcs:m
h
u 6 &
=A
C
’.D
? \4
a 5 G
cIT
COUNSEL AC UNIT
6
0
−F
V
H
T
R
N
D
3
.O
14 0
A
N
D
C
O
B
V
H
R
6
1P
.F
5
24"x4"
115 D4 A "AC-1"
D4 D4 D4
1M
N
O
T
C
E
D
P
2
0H
S
5B
F
.8
1M
N
O
T
C
E
D
P
2
0H
.B
S
5
8F 1M
N
O
T
C
E
D
P
2
0H
.B
S
5
8F
119 TV
FPF VSS VSS
F
3
7 N
1O
T
−0H
VR
.D
4
2
D
N
B
0
A
C
O
H
P
F
1.R
4
2
V
PUBLIC CORRIDOR S PUBLIC CORRIDOR 72" CLINIC GENERAL
FPR 100A 100A WAITING
1/2" = 1' - 0"
T SV SV
24"x4"
FPPR 100D
SV OS 1RPL3
DEDICATED FOR V V 5
BAS SYSTEM S
0' - 0"
2 3 TOILET-W TOILET-M
E-501 E-501 118 117
E E
JC E
S
0
R
5
1G
H
.N
9
C
3
2
O
FOR 120 E E
INVERTER PUBLIC CORRIDOR S S
CC
SV SV 1RPL3
S
TV
MONITORING 100A
x
E
a
m
3 2,4 1RPL3
SV 7
12' - 0"
E
x
a
m
Fire Alarm NAC Panel SD IT ROOM 42" EXAM EXAM 42" 42" EXAM
ISOLATION ROOM EXAM
ELEC 121 126 127 WAP 131 3.3
CR
Fire Alarm NAC Panel T 128 129 W 1w
0 C
n
ivert
W 1w
0
I
C
n
ivert
I
Dl 1g
W
a
en
t 7
t
Dl 1g
W
a
en
t 7
t
D4
3.3 60"
V V
60"
V
60" 60"
V 60"
V V
60"
(3)4"C
DW
a
en
t 7
1g
l t
E
m
a
x E
m
a
x
E
xa
m E
a
xm
NURSE CALL SV
1EQH1 BLOOD LAB SUPPORT CORRIDOR
E
m
a
x E
m
a
x
SV V 60" V 42"
3 ENLARGED 1ST FLOOR IDF ROOM CEILING PLAN
ecR
t 6
p10
E
WAP
1/4" = 1' - 0"
eR 6
p10
ct
132
WAP RTS
V WAP
CR
ULTRASOUND MEDICINE V DOCTORS
V DD DTU-R CR
eR
ct 6
p10
WAP
4 SV
eR
ct 6
p10
x
E
a
m
V V
CCT SV
24' - 0"
60" T ecR 6
p10
t
EXAM
42" NURSES / MA
CLEAN UTILITY EXAM 133
42"
143 140
141B S A.8
SUPPORT 60"
CORRIDOR 60" WAP 42"
VSS 163 V V PLYWOOD 9' - 7 1/8"
WF
16' - 0"
CR
E
x
a
m
E
x
a
m
x
E
a
m
SV S WF SV SV
x
E
a
m
V V
x
E
a
m
V V
x
E
a
m
V V V 1 2
CR 60" 60" 60" 60" 60" 60"
8' - 0"
E
m
a
x
137
E
m
a
x
1RPL3
VESTIBULE F101 BULK STORAGE EXAM EXAM 1,3 1RPL3 (4) 4" STUBBED UP
101 142 136 134 1RPL3
1/8" = 1' - 0"
J
WAP WAP IT ROOM EM:10
S102 42" 42" 42"
L6-30R OUTLET MOUNTED
0' - 0"
121
5 1LSL1
E
m
a
x
V
E
m
a
x
J
EM:10
FRONT
CCTV E
m
a
x
E
m
a
x
W a 17
D
len
t g
t
1RPL3
48' - 0"
3.3 10 3 TGB
PLYWOOD
3' - 6" 4' - 6 1/8"
32' - 0"
16' - 0"
1 100 LEVEL SYSTEMS PLAN 2 ENLARGED 1ST FLOOR IDF ROOM PLAN
1/16" = 1' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
0' - 0"
1t
0
p6
ecR
10
t
6
epcR
10
6
pt
ecR
SHUTDOWN RELAYS.
B COORDINATE AUDIO NOTIFICAITON DEVICES (SPEAKER/STROBES) AND
ASSOCIATED AUDIBLE LEVELS WITH AMBIENT NOISE IN ALL MECHANICAL SPACES.
1
3' - 0"
S
STAFF CORRIDOR DTU-R S 200C
M
0
1H
U
8
.
PASSENGER
1" = 1' - 0"
EQUIPMENT
212 211 210 DTU-R SHUNT TRIP
0
1H
U
M
8
.
1.8
CC
CLINIC MANAGER
TV
WAP WORK ROOM
214 200E TV
CR WAP 72"
1−C
G
2 S D4
WAP F
CR CR SV CLINIC GENERAL
6' - 0"
J WAITING
T
E
N
O
0
C
P
D
2
1M
5
H
S
8
.B
F
1−C
G
FURNITURE FEED 200C
M
0
1H
U
8
.
STAFF CORRIDOR 1B
2
8
X
P
S
5
H
T
N
C
E
0
D
O
.F
M T
D
O
N
C
P
E
0
8
1X
B
2
S
.5
H
M
F T
N
P
0
C
E
D
O
2
8
S
X
B
15
F
H
M
.
DENTAL SOILED D4
200F UTILITY RECEPTION F
C
o
n
18
f5
DENTAL STORAGE
SOCIAL WORKER 208 200B
1−C
G
209
E
N
T
P
C
D
O
M
0
S
12
H
5
.8
F
B
215 S
DENTAL OFFICE D4 S
F A.8
0
1H
U
M
8
.
217
4' - 0"
1−C
G
WAP
V WAP SV
J.C. D4
F
219 J
FURNITURE FEED TV
1−C
G
STAFF CORRIDOR D4 72"
D4 F AC UNIT
CC
24"x4"
M
1H
0U
8
.
N
H
9
DW
O
E
Y
14
F
2S
P
0 R
K
4
F
. S
P
7
2
TV
2.5 RTS RTS
2' - 0"
PSYCHOLOGIST SV
OFFICE DD S DD 3
ELEVATOR DEDICATED AHU-1S AHU-2S PUBLIC CORRIDOR (3)4"C
216 DTU-R DTU-R
60" TELEPHONE LINE 200A
1/2" = 1' - 0"
T
60" V PUBLIC CORRIDOR V V SV
T
24"x4"
TOILET-M 2RPL3
0' - 0"
200A 2 3 TOILET-W
E-502 E-502 220 OS 5
221 PLUMBING SHAFT
SEE ELEVATION E E
ELEC
ON E-607
222
FRONT
1G
C
− 1−C
G 1−C
G E E IT ROOM
SD x
E
a
m
223
3
SHARED RTS DTU-R RTS S
12' - 0"
PUBLIC CORRIDOR
E
x
a
m
x
E
a
m
42"
ROOM 200A AHU-2R 2,4 2RPL3
IT ROOM 228 230 231
S T DTU-R 7
218 223 EXAM WAP 42" 42" WAP 42"
TOILET CR 226 A ISOLATION ROOM
CR
R DTU-R 229
3.3
224 SV EXAM
E V SD A
WAP 227
8' - 0"
G
1−C
3.3 DTU-R CR
60"
V V
60"
V
60" 60"
V 60"
V V
60"
2RPL3
24"x4" 9
T
P
C
E
D
O
N
0
1F
.H
4
2
M
5
S
B
SV SV
S S (3)4"C
G
1−C
SUPPORT CORRIDOR EXAM CORRIDOR EXAM CORRIDOR
200H 200G NURSE CALL CONSOLE 200G
T
P
C
E
D
O
N
0
1F
.H
4
2
M
5
S
B
CR
4' - 0"
J J
V 60" 42"
eR
ct 6
p10
NURSES / MA NURSES / MA ENLARGED 2ND FLOOR MDF ROOM CEILING PLAN
N
O
T
C
E
D
P M
.H
1F
0 B
4
S
5
2
PROVIDER 3
V NURSES / MA
x
E
a
m
STAFFING 241A
E-502 1/4" = 1'-0"
245 BARIATRIC EXAM
246 SV
225
N
O
T
C
E
D
P M
.H
1F
0 B
4
S
5
2
SV J J
60"
eR 6
p10
ct
Dl 1g
W
a
en
t 7
t
0' - 0"
BARIATRIC EXAM
232
42"
N
O
T
C
E
D
P M
.H
1F
0 B
4
S
5
2
T
P
C
E
D
O
N
0
1F
.H
4
2
M
5
S
B
V MEDICINE DOCTORS
J.C.
eR
ct 6
p10
CR
C 5
C
o18
fn
fn
o 5
18
241 241C
244 V
E
x
a
m
V
M
N
O
T
C
E
D
P
0 H
1.B
4
F
S
5
2
N
P
0
C
E
D
O
T
M
1.B
H
F
S
2
4
5
4 S
eR
ct 6
p10
SV
TV V
x
E
a
m
CC SV
24' - 0"
ecR
t 6
p10
EXAM
200H CLEAN UTILITY 240 NURSES / MA A.8
NURSES / MA NURSES / MA 233
243 241B
241B 241B 60"
WF SV 60" 42"
STAIR #2 V V
VSS J J
S102 9' - 7 1/8"
16' - 0"
CR 3
CC SV SV SV
ELEV. CAB SPKR
x
E
a
m
V 60"
V V 60" 60"
V V 60" 60"
V V 60" E
x
a
m
AC-2
8' - 0"
S
ELEVATOR DEDICATED EXAM EXAM EXAM EXAM EXAM (4) 4"C STUBBED DOWN TO IDF IN IT ROOM 121
E
m
a
x
E
m
a
x
TELEPHONE LINE WAP 239 238 237 236 234 2RPL3
WAP
WAP
1/8" = 1' - 0"
242 EXAM 6
11' - 5 1/8"
SD 42" 42" 235 42" 2RPL3
0' - 0"
E
m
a
x
FRONT
lW
a
n
et 7
D 1g
t
E
m
a
x
E
m
a
x
3.3 TMGB
2RPL3
8
32' - 0"
16' - 0"
1 200 LEVEL SYSTEMS PLAN 2 ENLARGED 2ND FLOOR MDF ROOM PLAN
1/16" = 1' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
EMERGENCY NEUTRAL
NOTES:
0' - 0"
Emergency Note:
3. LIGHTING CONTROL PANEL SHALL BE PROGRAMMED AS FOLLOWS: Emergency load tracks with
QuickConnect coupler
(GGRC-COUPLER)
1. TURN LIGHTS "ON" AT PRESET TIME BY OWNER. LIGHTING SHALL REMAIN "ON" normal lighting YELLOW load for
DURING BUSINESS HOURS. On/OFF. If dimming it will be
2. TURN LIGHTS "OFF" AT PRESET TIME BY OWNER UNLESS MOTION IS DETECTED LIGHTING LOAD (3) PURPLE
adjusted with the dimming zone it
BY OCCUPANCY SENSORS. is connected to. Under cabinet
1. A LOW VOLTAGE OVERRIDE BUTTON SHALL BE PROVIDED AS SHOWN ON Upon loss of normal power to the Adjustable
2' - 0"
Daylight sensor
PLAN. RC3DE, the emergency load will daylight sensor (DSRC-FMOIR)
dome *Immediately provides
be forced On and full bright to *Requires 0-10v multi-zone daylight dimming
upon powerup
4. INSTALLATION SHALL BE SUITABLE FOR USE IN AIR HANDLING PLENUM SPACES PER 100%. dimming ballasts
NATIONAL ELECTRIC CODE (NEC). ALL CABLING SHALL BE PLENUM RATED.
In room ladderless testing is done
5. COMPLY WITH IECC 2015 FOR ELECTRICAL MONITORING, LIGHTING. PROVIDE RELAYS by pressing the "All Off" button
AND ASSOCIATED WIRING AS REQUIRED FOR A COMPLETE AND FUNCTIONAL four times, within 3 seconds.
Model: OCC-RJ45
Blue
Adjustable Skylights
Red
Brown
Adjustable Skylights
Switchpack
White
QuickConnect Cables
Red Receptacle
CAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation.
BMS/Out
OCC-RJ45 Dual Technology
AUTO AND MANUAL 100%. LIGHTING SHALL REDUCE AUTOMATICALLY TO BLACK - Hot
Black
Green
Sensors
Sensors
5 (Occupancy Coupler) Ceiling Sensor
Occupancy/Vacancy Sensor
50% WHEN OCCUPANCY SENSOR IS IDLE FOR 20 MINUTES AND FULL OFF. (120/277VAC)
Slider
Station *Allows connection to any
Integration Controls
(OAC-DT-1000-R)
1" = 1' - 0"
4 Greengate Occupancy/Vacancy
Blue - Load In
A/V -
Integration Controls
BLUE - Relay In
Model: OCC-RJ45
Blue
3
Demand
Response + Red
Manual On/Automatic Off (all loads) for
(120/277VAC) - Black
0' - 0"
Alert
maximum energy savings
C. EXTERIOR LIGHTING PART OF TENANT SPACE SHALL AUTOMATICALLY SHUT Mode
Time
Clock
+
-
+
Brown
White/Orange - 277V N
White/Black - 120V N
(Occupancy Coupler)
AND 6AM OR BUSINESS OPENING WHICHEVER COMES FIRST. 1
Black - Line In
D. MONITOR USAGE AT MINIMUM EVERY 15 MINUTES AND REPORT AT LEAST Energy Options DIP Switch
High End
Options
Demand Response Occupancy Not Used
Energy
1 2 3 4 BMS/ Egress Output:
HOURLY, DAILY, MONTHLY AND ANNUALLY. STORE DATA FOR THE YELLOW
Default 10% Occ
Occupancy status output to the Building
Reset
20% Vac (default)
30%
Low End
40%
Management System or other 3rd party system
FOLLOWING AT MINIMUM OF 36 MONTHS: Emergency Power OUT
Status
require no programming of the Room Controller
a. TOTAL ELECTRICAL ENERGY USE and occurs when ever there is occupancy in the
Adjustment
0-10V Gain
BLUE - Emergency Power In room regardless of light output status.
Blue - EM Line In
+ - + - + -
(120/277VAC)
6' - 0"
6. PROVIDE A SINGLE LIGHTING CONTROL SYSTEM FOR ALL PUBLIC AREAS. LC SHALL *0-10V Dimming Zone Note:
SERVE ALL AREAS INCLUDING CORRIDORS AND WAITING ROOMS, BREAK ROOMS, The 0-10V dimming zones within the Room Controller
can be wired and controlled independent of the
CONFERENCE AND TRAINING AND INDIVIDUAL ROOMS SUCH AS EXAM, PRIVATE
connected loads. This allows a each load to have a
4' - 0"
Raise
Button 4: Load (1),(2),(3) Lower
Button 5: Load (1),(2),(3) Off
Gray - Dimmer 2 Lower
All Off
Quick connect cables are
pre-terminated and included
Violet - Dimmer 3
2' - 0"
0' - 0"
To Lighting loads
sensors per 1. SWITCH IS REQUIRED
To 0-10V Drivers
power pack) TO TURN LOAD ON.
120/277 VAC BLACK BLUE
2. LOAD TURNS OFF
Network Time Network Wall Network Wall WHEN SENSOR TIMES
Clock Station Controller Station Controller OUT OR WITH SWITCH.
24' - 0"
DALI - SCDM4
cover of the Lighting Inputs for End (for Manual (example Network GREEN WHITE LOAD
(Mount above ceiling
Control Panel) Devices Override ON of Lobby/Reception
in the corridor near
Panelboard) the Timeclock with 3 LV
and Public buttons to ONW AUTOMATIC MODE
Area control zones
occupancy "a", "b", and "c" GROUND
sensors) 1. WHEN SENSOR ACTIVATES LOAD
8' - 0"
TURNS ON.
1 LIGHTING CONTROL DIAGRAM - PUBLIC AREAS 2 LIGHTING CONTROL DIAGRAM - STAND ALONE CONTROL (INDIVIDUAL ROOMS)
32' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
ALARM
SHUNT
0' - 3"
INPUT CR
1-1/4" CONDUIT 1" CONDUIT
3" = 1' - 0"
CONDUIT RUN
(TYP.)
REQUEST
0' - 0"
DEVICES
ELECTRIC STRIKE/LOCK ES
TYPICAL
DGP
FUSE
1" = 1' - 0"
24 VDC POWER
- +
0' - 0"
8 SCHEMATIC WIRING DIAGRAM FOR STRIKES/LOCKS 7 ACCESS CONTROL SYSTEM SCHEMATIC DESIGN 6 ACCESS CONTROL SYSTEM CONDUIT REQUIREMENTS
E-602 NOT TO SCALE E-602 NOT TO SCALE E-602 NOT TO SCALE
4' - 0"
1 1
2' - 0"
1
1/2" = 1' - 0"
0' - 0"
2
3 3
2 2 2 NOTES:
1. DOOR DETAILS ARE PROVIDED TO SHOW DEVICE
2
5 LOCATIONS AND CONDUIT REQUIREMENTS.
1. DOOR DETAILS ARE PROVIDED TO SHOW DEVICE IN EITHER DIRECTION. REFER TO PLAN DRAWINGS
LOCATIONS AND CONDUIT REQUIREMENTS. FOR ACTUAL DOOR SWING.
NOTES:
2. DOORS SHOWN IN DETAIL DRAWINGS MAY SWING 2 3. COORDINATE DEVICE LOCATIONS AND MOUNTING
1. DOOR DETAILS ARE PROVIDED TO SHOW DEVICE
IN EITHER DIRECTION. REFER TO PLAN DRAWINGS HEIGHT WITH ARCHITECTURAL DETAILS. IDENTIFY
LOCATIONS AND CONDUIT REQUIREMENTS.
FOR ACTUAL DOOR SWING. ANY CONFLICTS TO THE ENGINEER FOR
6" 6" 6" CLARIFICATION.
8' - 0"
CLARIFICATION.
KEY NOTES :
1/4" = 1' - 0"
MUDRING.
5. REX DEVICE MOUNTED ON SECURED SIDE OF
5. REX DEVICE MOUNTED ON SECURED SIDE OF DOOR. 4"x4" OUTLET BOX WITH ONE-GANG
DOOR. 4"x4" OUTLET BOX WITH ONE-GANG MUDRING.
MUDRING.
16' - 0"
FLOOR FLOOR
8' - 0"
5 CONDUIT DETAIL FOR SINGLE DOOR WITH DOOR STATUS MONITORING 4 CONDUIT DETAIL FOR CARD READER CONTROLLED SINGLE DOOR 3 CONDUIT DETAIL FOR CARD READER CONTROLLED DOUBLE DOOR
E-602 NOT TO SCALE E-602 NOT TO SCALE E-602 NOT TO SCALE
1/8" = 1' - 0"
0' - 0"
4
5/16" MAX.
FINISHED SCHEDULED
CEILING PARTITION A
32' - 0"
GROMMET 3
INSTALL J-BOX ABOVE ADJACENT
CEILING IF ACCESSIBLE OR FLUSH IN
WALL 4" BELOW CEILING IF CEILING IS 6" KEY NOTES :
NOT ACCESSIBLE. MOUNT SO THAT A 1. HOLE IN HEAD OF FRAME LOCATED 6" FROM STRIKE SIDE OF
JUNCTION BOX ACCESS COVER IS ON FRAME FOR CONCEALED DOOR POSITION SWITCH. INSTALL
HEADED
16' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
CHICAGO
3" = 1' - 0"
PLENUM
JUNCTION BOX
0' - 0"
BE PROVIDED BY OWNER
0' - 0"
PATCH PANEL
4' - 0"
OWNER-PROVIDED PC WITH
CAMERA CLIENT VIEWING SOFTWARE
CAMERA
2' - 0"
2. WHERE CEILING-MOUNTED CAMERAS ARE TO BE INSTALLED ON CEILING TILES, THEY SHALL BE SECURITY CONTRACTOR TO PROVIDE CONNECTION TO DATA JACKS AS SHOWN.
CENTERED ON THE TILE IN BOTH DIRECTIONS. (NETWORK JACK, CABLING AND PATCH CABLES PROVIDED BY TECHNOLOGY CONTRACTOR)
0' - 0"
RJ45 PORT # 1
JACK
REAR OF PATCH PANEL
1/4" = 1' - 0"
1
T568B WIRING T568B WIRING T568B WIRING T568B WIRING T56 8B WIRING T568B WIRING
6
1/8" = 1' - 0"
5
0' - 0"
1
2
2
48' - 0"
WH/BL 4
TYPE I CABLE BL
WH/OR
OR 5
32' - 0"
WH/GR
GR
WH/BR NOTES: 4
BR 1. REFER TO TECHNOLOGY DRAWINGS FOR EXACT MOUNTING HEIGHTS. 3
PATCH TO
SWITCH
16' - 0"
KEY NOTES :
1. PENETRATION IN WALL FILLED WITH APPROVED SEALANT.
1/16" = 1' - 0"
T568B WIRING T568B WIRING 2. 1" CONDUIT AND JUNCTION BOX WITH NETWORK CABLING.
4. EXTERIOR WALL.
3. NETWORK IP CAMERA IN ENVIRONMENTAL HOUSING MOUNTED
5. 6" x 6" x 4" DEEP JUNCTION BOX MOUNTED FLUSH IN WALL. ABOVE GROUND LEVEL.
7. PENDANT MOUNT FOR CAMERA DOME. 5. CORNER MOUNT FOR CAMERA DOME.
3 IP CAMERA PATCHING AND TERMINATION CONVENTION 2 EXTERIOR CAMERA - WALL MOUNT PENDANT CAMERA DETAIL 1 EXTERIOR CAMERA - BUILDING CORNER MOUNT DETAIL
E-603 NOT TO SCALE E-603 NOT TO SCALE E-603 NOT TO SCALE
90' - 0"
60' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
8
0' - 6"
1
3" = 1' - 0"
3
0' - 0"
1
3' - 0"
6 (TYP.)
LABEL HERE LABEL HERE 2
2' - 0"
5 7
WHITE-ORANGE
3. NYLON PULL CORD TO FAR END CONDUIT TERMINATION POINT. CONDUIT FILL CAPACITY 40%
BLUE
1" = 1' - 0"
4. MODULAR JACK 110 TO RJ45 WITH ICONS, UNIVERSAL WIRING PATTERN, NON KEYED, EIGHT POSITION (4 PAIR). HIS CONDUIT FILL RATIO CHART
PAIR 1 PAIR 3
0' - 0"
WHITE-BLUE
5. CAT6A CABLE FROM MDF WITH SERVICE LOOP CONDUIT SIZE THE NUMBER OF CABLES ALLOWED
IDF ROOM NUMBER
7. 2" CONDUIT WITH PULL CORD TO ACCOMMODATE 8 CAT6A CABLES BACK TO NEAREST CABLE TRAY. WHITE-BROWN 1 1/4" 4
D4 D4 BROWN
2" 4
2 1/4" 4
1-1 1-2
12345678 3" 4
4' - 0"
11 OP CENTER DATA DETAIL 10 TYPICAL T568B WIRING SCHEMATIC 9 CONDUIT FILL CAPACITY 40% 8 LABELING SCHEME
E-604 1/8" = 1'-0" E-604 NOT TO SCALE E-604 NOT TO SCALE E-604 NOT TO SCALE
2' - 0"
1/2" = 1' - 0"
0' - 0"
2. THIS DETAIL SHOWS WHAT IS TYPICAL TO BOND TO THE GROUND BUS DOUBLE GANG BACKBOX WITH
BAR IN EACH COMMUNICATIONS CLOSET OR DISTRIBUTION ROOM. SINGLE GANG PLASTER RING
8' - 0"
F-81 CONNECTOR
0' - 0"
CONNECTOR
CAT 6A OR BETTER
(2) TELECOMMUNICATION OUTLET (1) TELECOMMUNICATION OUTLET
DATA = COLOR WHITE PN:760149989
CONNECTOR CONNECTOR
CAT 6A OR BETTER CAT 6A OR BETTER
DATA = COLOR WHITE PN:760149989 DATA = COLOR WHITE PN:760149989
16' - 0"
1/16" = 1' - 0"
LABEL HERE
1 GANG (2) PORT FACEPLATE
+48" AFF
T
+18" AFF OR AS NOTED 48" AFF
90' - 0"
4 DATA DROP DETAIL 3 CLOCK DROP DETAIL 2 WAP DETAIL 1 WALL TELEPHONE DROP DETAIL
E-604 NOT TO SCALE E-604 NOT TO SCALE E-604 NOT TO SCALE E-604 NOT TO SCALE
60' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
DESCEND FROM CABLE TRAY L6-30R, 30A L6-30R, 30A DESCEND FROM CABLE TRAY
RECEPTACLE RECEPTACLE
0' - 6"
AMCO TCMR-45U-10/116-T
1'-0" 1'-0" AMCO TCMR-45U-10/116-T
12 STRAND MULTIMODE
FIBER TO IDF 121 12 STRAND MULTIMODE
0' - 3"
RACK ALLOCATED FOR RACK ALLOCATED FOR WORK TO BE PERFORMED BY COMMSCOPE UNIPRISE CERTIFIED
ADDITIONAL ADDITIONAL INSTALLERS.
48 PORT PATCH 48 PORT PATCH
PANELS PANELS 3. ALL UPS AND PDU STRIPS TO BE FURNISHED AND INSTALLED BY
COMMSCOPE COMMSCOPE CONTRACTOR.
UNPA-U-10G-2U-48 UNPA-U-10G-2U-48
2' - 0"
E: MARK@PLTECHNOLOGIES.COM
FOR CURRENT CCHHS PRICING FOR ALL MATERIALS.
1" = 1' - 0"
0' - 0"
48 PORT PATCH 6" CABLE MANAGER 6" CABLE MANAGER 48 PORT PATCH
PANELS AMCO TCMFD-45U-6/116-T AMCO TCMFD-45U-6/116-T PANELS
1-9 (TYP.) (TYP.) 1-9
6" CABLE MANAGER
EATON/B LINE CAT # (1-9 REQUIRED) (1-9 REQUIRED)
SB87019S4FB (TYP) COMMSCOPE COMMSCOPE
6' - 0"
UNPA-U-10G-2U-48 UNPA-U-10G-2U-48
UPS SUBFEED TO PDU
L6-30R, 30A
RECEPTACLE
L6-30R, 30A
RECEPTACLE
2' - 0"
1/2" = 1' - 0"
RACK 1 RACK 1
0' - 0"
UPS EATON 9PX6K 6 KVA 10" CABLE MANAGER 10" CABLE MANAGER UPS EATON 9PX6K 6 KVA
WITH MAINT. BYPASS #MBP6K208 AMCO AMCO WITH MAINT. BYPASS #MBP6K208
FRONT TCMFD-45U-10/116-T
(TYP. OF 3)
TCMFD-45U-10/116-T
(TYP. OF 3) REAR
12' - 0"
AMCO TCMR-45U-10/116-T 12 STRAND MULTIMODE FIBER AMCO TCMR-45U-10/116-T 1'-0" 1'-0" AMCO TCMR-45U-10/116-T
FROM IDF 121 TO MDF 223
0' - 0"
TOP TOP
PLAN ON SHEET 2 & 3/E-501
25 PAIR COPPER PANEL
25 PAIR COPPER PANEL
NORTH WALL
NORTH WALL
RACK ALLOCATED FOR RACK ALLOCATED FOR
16' - 0"
ADDITIONAL ADDITIONAL
48 PORT PATCH 48 PORT PATCH
PANELS PANELS
COMMSCOPE COMMSCOPE
UNPA-U-10G-2U-48 UNPA-U-10G-2U-48
PDU MOUNTED ON REAR
MODEL: EATON
8' - 0"
EMI-104-10
1/8" = 1' - 0"
L6-30R, 30A
RECEPTACLE
1/16" = 1' - 0"
L6-30R, 30A
RECEPTACLE
0' - 0"
UPS EATON 9PX6K 6 KVA 10" CABLE MANAGER 10" CABLE MANAGER UPS EATON 9PX6K 6 KVA
WITH MAINT. BYPASS #MBP6K208 AMCO AMCO WITH MAINT. BYPASS #MBP6K208
FRONT TCMFD-45U-10/116-T
(TYP. OF 3)
TCMFD-45U-10/116-T
(TYP. OF 3) REAR
2 IDF ROOM 121 RACK DETAIL - FRONT AND REAR ELEVATION 3 110 BLOCK TO PATCH PANEL IN RACK
90' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
0' - 0"
3' - 0"
2' - 0"
1' - 0"
1" = 1' - 0"
0' - 0"
MDF.
6' - 0"
MDF.
4' - 0"
2' - 0"
1/2" = 1' - 0"
0' - 0"
12' - 0"
8' - 0"
4' - 0"
1/4" = 1' - 0"
0' - 0"
24' - 0"
16' - 0"
8' - 0"
1/8" = 1' - 0"
0' - 0"
48' - 0"
32' - 0"
16' - 0"
1/16" = 1' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
0' - 0"
3' - 0"
2' - 0"
1' - 0"
1" = 1' - 0"
0' - 0"
6' - 0"
4' - 0"
2' - 0"
1/2" = 1' - 0"
MDF.
0' - 0"
MDF.
12' - 0"
8' - 0"
4' - 0"
1/4" = 1' - 0"
0' - 0"
24' - 0"
16' - 0"
8' - 0"
1/8" = 1' - 0"
0' - 0"
48' - 0"
32' - 0"
16' - 0"
1/16" = 1' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
LUMENWERX VIA-3RF-HLO-LED-80-1000-35-4FT-UNV-D1-1-TG9-W-CP
0' - 0"
GAMMALUX GB34RC2-1SL358-UNIV-DVR-[LENGTH]-REC/XXXX-ASLMD-
WH-CP
F1A LINEAR RECESSED DIRECT LED FIXTURE RECESSED 120V 3500K 30W NEO-RAY S123-DR-2-35-GYP-0048-1-U-HCD-CP-1-W
LUMENWERX VIA-3RF-HLO-LED-80-1000-35-4FT-UNV-D1-1-DTL-W-CP
GAMMALUX GB34RC2-1SL358-UNIV-DVR-[LENGTH]-REC/XXXX-ASLMD-
3' - 0"
WH-CP
F1B LINEAR RECESSED DIRECT LED FIXTURE RECESSED 120V 3500K 30W NEO-RAY S123-DR-2-35-GYP-0048-1-U-HCD-CP-1-W
LUMENWERX VIA-3RF-HLO-LED-80-1000-35-4FT-UNV-D1-1-DTL-W-CP
GAMMALUX GB34RC2-1SL358-UNIV-DVR-[LENGTH]-REC/XXXX-ASLMD-
2' - 0"
WH-CP
F2 2x4 LED RECESSED TROFFER (EXAM ROOMS) RECESSED 120V 3500K 35W LIGTHONIA LIGHTING 2GTL-G-4-48L-FLUSH STEEL, WHITE-MVOLT-GZ1-LP835-CP
CORELITE DRI-WS-2-L35-UNV-24-T-HCD-CP
CORELITE D3X-WO-42L-835-UNV-24-T1-STD-CP
F3 6" CYLINDER WITH PAR38 LED PENDANT FIXTURE PENDANT 120V 3500K 30W CONTECH LIGHTING CI6-P-ML28D-2035K-C-P-CSK48-P
1" = 1' - 0"
F4 6" ROUND DOWNLIGHT LED FIXTURE RECESSED 120V 3500K 18W HALO PD6CP-15-ED010-PDM6A-835-61V-C
0' - 0"
F5 2X2 LED RECESSED TROFFER RECESSED 120V 3500K 38W NEO-RAY S282R-C-2-L35K-FTG-U-DD-1-D-95HT
CORELITE DRI-WS-3-L35-22-T1-STD-CP
CORELITE D3X-WO-31L-935-LD5-UNV-22-T1-STD-CP
F6 DIRECT/INDIRECT LINEAR PENDANT FIXTURE PENDANT 120V 3500K 47W LUMENWERX VIA3PDI-HLO-WIO-LED-80-750-750-35-4FT-UNV-D1-1-53WAC
4' - 0"
36-W
NEO-RAY
S124-DIP-ULO-LO-35-SC48-JB-0048-1-D-UNV-1-NA-W
F6A 120V 3500K
F6B LINEAR RECESSED DIRECT LED FIXTURE RECESSED 120V 3500K 30W NEO-RAY S123-DR-2-35-GYP-0048-1-U-HCD-CP-1-W
2' - 0"
LUMENWERX VIA-3RF-HLO-LED-80-1000-35-4FT-UNV-D1-1-DTR-W-CP
GAMMALUX GB34RC2-1SL358-UNIV-DVR-4-REC/XXXX-ASLMD-WH-CP
1/2" = 1' - 0"
F7 UNDERCABINET FIXTURE SURFACE 120V 4000K 12W WILLIAMS LIGHTING 1SF-2FT-L6-DMA-AMW-OCCLV OSF10-10W-DVR-UNV
HALO HU10-18-D-FROSTED-30-P-HU106-HU109-HU10MS
0' - 0"
NEO-RAY S123-RDRP-1-35-FTG-4-1-UNV-ED-CP-1-W
LUMENWERX VIA3RR-HLO-LED-80-500-35-4FT-UNV-D1-1-FTG-W-CP
F9 LINEAR LED WALLWASH FIXTURE LENS RECESSED 120V 3500K 35W LUMENWERX VIA5R-WRO2-LED-80-375-35-8FT
12' - 0"
ELAN 84031
S3 EXTERIOR BOLLARD BOLLARD 277V 3000K 17W FORMS & SURFACES SERIES 600
1/4" = 1' - 0"
0' - 0"
GENERAL NOTES:
A. ALL FIXTURES AND THEIR INSTALLATIONS SHALL BE PLENUM RATED. ALL WIRING SHALL BE IN CONDUIT.
B. ALL EXTERIOR FIXTURES AND THEIR INSTALLATIONS SHALL BE RATED FOR WET LOCATIONS.
24' - 0"
16' - 0"
8' - 0"
1/8" = 1' - 0"
0' - 0"
48' - 0"
32' - 0"
16' - 0"
1/16" = 1' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
EQUIPMENT SCHEDULE
EQUIP. DESCRIPTION LOCATION VOLTS / FEEDER / FED LOAD STARTER / CONTROLLER LOCAL DISC. SWITCH NOTES
0' - 6"
TAG PHASE BRANCH CCT. FROM KVA HP FLA TYPE NEMA SIZE PROVIDED BY SIZE FUSE PROV. BY
RTU-1 ROOF TOP UNIT ROOF 480/3 3#1, 1 #6 GND IN 1 -1/2" C SEE PANEL SCHEDULE 70.2 84 VFD - MC 200 - E.C.
RTU-2 ROOF TOP UNIT ROOF 480/3 3#1, 1 #6 GND IN 1 -1/2" C SEE PANEL SCHEDULE 70.2 84 VFD MC 200 - E.C.
0' - 3"
AC-1 AIR CONDITIONING UNIT 120 IT ROOM 208/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 4.9 14 - MC 30 - E.C.
3" = 1' - 0"
AC-2 AIR CONDITIONING UNIT 223 IT ROOM 208/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 4.9 14 - MC 30 - E.C.
0' - 0"
FC-S101 AIR CONDITIONING UNIT STAIR #1 208/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 2.7 8 MC TOS E.C.
AC-S102 AIR CONDITIONING UNIT STAIR #2 208/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 0.4 1 MC TOS E.C.
AC-210 AIR CONDITIONING UNIT DENTAL EQPM 210 208/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 0.4 1 MC TOS E.C.
ACCU-1 AIR COOLED CONDENSING UNIT ROOF 208/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 5.2 14 - MC 30 - E.C.
3' - 0"
ACCU-2 AIR COOLED CONDENSING UNIT ROOF 208/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 5.2 14 - MC 30 - E.C.
ACCU-3 AIR COOLED CONDENSING UNIT ROOF 208/1 2#10, 1 #10 GND IN 3/4" C SEE PANEL SCHEDULE 8.0 22 - MC 30 - E.C.
ACCU-4 AIR COOLED CONDENSING UNIT ROOF 208/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 4.9 14 - MC 30 - E.C.
ACCU-5 AIR COOLED CONDENSING UNIT ROOF 208/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 5.2 14 - MC 30 - E.C.
2' - 0"
B-1 BOILER MECHANICAL ROOM 119 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 0.5 4 - MC 30 - E.C.
B-2 BOILER MECHANICAL ROOM 119 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 0.5 4 - MC 30 - E.C.
EUH 1-1 ELECTRIC UNIT HEATER ELECTRICAL ROOM 119A 480/3 3#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 5.0 6 - MC 30 - E.C.
1' - 0"
PFS-1 PRESSURE FILL SYSTEM MECHANICAL ROOM 119 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 0.5 - MC TOS - E.C.
CUH 1-1 CABINET UNIT HEATER VESTIBULE 100 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/15 - MC TOS - E.C.
1" = 1' - 0"
CUH 1-2 CABINET UNIT HEATER VESTIBULE 100 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/15 - MC TOS - E.C.
0' - 0"
CUH 1-3 CABINET UNIT HEATER VESTIBULE 101 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/15 - MC TOS - E.C.
UH 1-1 CABINET UNIT HEATER MECH 119 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/20 MC TOS E.C.
HWP-1 PUMP MECHANICAL ROOM 119 480/3 3#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 2 VFD MC 30 E.C.
HWP-2 PUMP MECHANICAL ROOM 119 480/3 3#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 2 VFD MC 30 E.C.
6' - 0"
TEF-1 EXHAUST FAN ROOF 480/3 3#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1 MC TOS E.C.
EF-1 EXHAUST FAN ROOF 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/25 MC TOS E.C.
EF-2 EXHAUST FAN ROOF 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/25 MC TOS E.C.
4' - 0"
EF-3 EXHAUST FAN ROOF 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/4 MC TOS E.C.
EF-4 EXHAUST FAN ROOF 480/3 3#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 3/4 MC TOS E.C.
EF-5 EXHAUST FAN ROOF 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/6 MC TOS E.C.
EF-119 EXHAUST FAN ROOF 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/3 - MC TOS - E.C.
2' - 0"
VAV 1-22 VARIABLE AIR VOLUME OUTSIDE OF ISOLATION ROOM 128 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/4 - MC TOS - E.C.
1/2" = 1' - 0"
VAV 2-23 VARIABLE AIR VOLUME OUTSIDE OF ISOLATION ROOM 229 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/4 - MC TOS - E.C.
ESP-1 ELEVATOR SUMP PUMP FREIGHT ELEVATOR F101 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/2 MC TOS - E.C.
0' - 0"
ESP-1 ELEVATOR SUMP PUMP PASSENGER ELEVATOR P101 120/1 2#12, 1 #12 GND IN 3/4" C SEE PANEL SCHEDULE 1/2 MC TOS - E.C.
188.1
GENERAL NOTES:
A. ALL 3-PHASE STARTERS THAT ARE TO BE PROVIDED BY DIVISION 26 SHALL BE FULL VOLTAGE, NON-REVERSING TYPE AND H-O-A (HAND-OFF-AUTO) SWITCH WITH LED INDICATING LIGHTS, 120V CONTROL TRANSFORMER
12' - 0"
AND 2 SETS OF NORMALLY OPEN AND 2 SETS OF NORMALLY CLOSED CONTACTS TO ALLOW CONTROL OF EQUIPMENT BY LOW VOLTAGE SIGNAL FROM TEMPERATURE CONTROL CONTRACTOR U.O.N.
B. PROVIDE ALL 24 VOLT CONTROL WIRING IN CONDUIT PER MANUFACTURER'S WIRING DIAGRAMS AND RECOMMENDATIONS.
C. CONTRACTOR SHALL PROVIDE A LABEL ON ALL MECHANICAL EQUIPMENT DISCONNECT DEVICES INDICATING EQUIPMENT NAME, VOLTAGE, CIRCUIT NUMBER AND SOURCE OF
AC POWER. COORDINATE EXACT LABELING REQUIREMENTS WITH OWNER AND DIVISION 23.
D. ENCLOSURE SELECTION FOR STARTERS AND DISCONNECT SWITCH TO BE AS FOLLOW:
8' - 0"
INTERIOR - NEMA 1
OUTDOOR - NEMA 3R TOS = THERMAL OVERLOAD SWITCH
E.C. = ELECTRICAL CONTRACTOR
M.C. = MECHANICAL CONTRACTOR
FVNR = FULL VOLTAGE NON-REVERSING
4' - 0"
0' - 0"
24' - 0"
16' - 0"
8' - 0"
1/8" = 1' - 0"
0' - 0"
48' - 0"
32' - 0"
16' - 0"
1/16" = 1' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
Supply From: Phases: 3 Mains Type: MAIN CB Supply From: DP-01 Phases: 3 Mains Type: MAIN CB Supply From: MDP Phases: 3 Mains Type: MAIN CB
Mounting: SURFACE Wires: 4 Mains Rating: 100.0 A Mounting: SURFACE Wires: 4 Mains Rating: 100.0 A Mounting: SURFACE Wires: 4 Mains Rating: 225.0 A
Enclosure: NEMA 1 MCB Rating: 100.0 A Enclosure: NEMA 1 MCB Rating: 100.0 A Enclosure: NEMA 1 MCB Rating: 200.0 A
0' - 6"
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
3" = 1' - 0"
EM:1 EM LIGHTING CORRIDOR 20.0 A 1 588 VA 35 VA 1 20.0 A 1ST FLR EXIT SINGS EM:2 1 LTG PUBLIC CORRICOR 1400A 20.0 A 1 540 VA 552 VA 1 20.0 A EXAM CORRIDOR 163, 101B 2 1 LITES 20.0 A 1 735 VA 933 VA 1 20.0 A LITES 2
EM:3 Lighting Space 243 20.0 A 1 498 VA 45 VA 1 20.0 A 1ST FLR EXIT SIGNS EM:4 3 LTG RECEPTION 100B 20.0 A 1 269 VA 420 VA 1 20.0 A LTG DC AREA 141C, NURSE 141B 4 3 2078... 497 VA 4
0' - 0"
EM:5 LTG 2ND FLR EM 20.0 A 1 740 VA 40 VA 1 20.0 A 2ND FLR EXIT SIGNS EM:6 5 LTG 261, 262, 263, 264, 265, 266, 255 20.0 A 1 1214... 720 VA 1 20.0 A LTG EXAM RMS 6 5 ELECTRIC UNIT HEATER EUH-1-1 20.0 A 3 2078... 497 VA 3 20.0 A HWP-1 (PUMP) 6
EM:7 LTG 2ND FLR EM 20.0 A 1 566 VA 35 VA 1 20.0 A 2ND FLR EXIT SIGNS EM:8 7 LTG 119A, 120, 122, 20.0 A 1 432 VA 120 VA 1 20.0 A LTG UTILIY, EXAM RMS 8 7 2078... 497 VA 8
EM:9 FACP 20.0 A 1 0 VA 200 VA 1 20.0 A Other EM:10 9 Other 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 10 9 497 VA 582 VA 10
EM:11 FIRE ALARM NAC PANEL 20.0 A 1 200 VA EM:12 11 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 12 11 HWP-2 (PUMP) 20.0 A 3 497 VA 582 VA 3 20.0 A TEF-1 12
EM:13 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:14 13 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 14 13 497 VA 582 VA 14
EM:15 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:16 15 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 16 15 443 VA 16
3' - 0"
EM:17 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:18 17 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 18 17 FAN EF-4 20.0 A 3 443 VA 18
EM:19 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:20 19 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 20 19 443 VA 20
EM:21 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:22 21 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 22 21 22
EM:23 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:24 23 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 24 23 24
EM:25 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:26 25 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 26 25 26
2' - 0"
EM:27 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:28 27 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 28 27 28
EM:29 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:30 29 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 30 29 30
EM:31 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:32 31 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 32 31 32
EM:33 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:34 33 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 34 33 34
EM:35 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:36 35 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 36 35 36
EM:37 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:38 37 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 38 37 38
1' - 0"
EM:39 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:40 39 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 40 39 40
EM:41 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE EM:42 41 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 42 41 42
Total Load: 1225 VA 744 VA 981 VA Total Load: 1644 VA 689 VA 1934 VA Total Load: 5766 VA 4098 VA 4098 VA
1" = 1' - 0"
Total Amps: 10.5 A 6.2 A 8.5 A Total Amps: 14.9 A 5.7 A 17.3 A Total Amps: 20.8 A 14.8 A 14.8 A
Legend: Legend: Legend:
0' - 0"
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
POWER 400 VA 100.00% 400 VA POWER 0 VA 0.00% 0 VA MOTORS 6058 VA 100.00% 6058 VA
LITES 2549 VA 100.00% 2549 VA Total Conn. Load: 2949 VA LITES 4267 VA 100.00% 4267 VA Total Conn. Load: 4267 VA LITES 1668 VA 100.00% 1668 VA Total Conn. Load: 7726 VA
Total Est. Demand: 2949 VA Total Est. Demand: 4267 VA Total Est. Demand: 7726 VA
6' - 0"
Mounting: SURFACE Wires: 4 Mains Rating: 225.0 A Mounting: SURFACE Wires: 4 Mains Rating: 400.0 A Mounting: SURFACE Wires: 4 Mains Rating: 225.0 A
Enclosure: NEMA 1 MCB Rating: Enclosure: NEMA 1 MCB Rating: 400.0 A Enclosure: NEMA 1 MCB Rating:
0' - 0"
Notes: Notes:
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
12' - 0"
1 RECP 133 20.0 A 1 50 VA 770 VA 1 20.0 A RECP 138, 139 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
3 RECEPTACLES Space 203 20.0 A 1 1860... 900 VA 1 20.0 A RECEPTACLES Space 209 4 1 2552... 7248... 2 1 BOILER B-1 20.0 A 1 660 VA 660 VA 1 20.0 A BOILER B-2 2
5 RECP 132 20.0 A 1 1500... 1080... 1 20.0 A RECP 142, F101, 141 6 3 1RLP1 250.0 A 3 2648... 8036... 3 250.0 A 1RPL2 4 3 PRESSURE FILL SYSTEM PFS-1 20.0 A 1 900 VA 988 VA 4
7 REF - 111 20.0 A 1 180 VA 180 VA 1 20.0 A MW - 111 8 2 20.0 A AIR CONDITIONING UNIT FC-S101
5 2771... 6916... 6 5 200 VA 988 VA 6
9 TABLE EXAM 134 20.0 A 1 1500... 180 VA 1 20.0 A MW - 111 10 AIR CONDITIONING UNIT AC-210 20.0 A 2
7 1644... 0 VA 1 20.0 A SPARE 8 7 200 VA 1110... 1 20.0 A VAV-1-22 8
11 TABLE EXAM 135 20.0 A 1 1860... 1690... 1 20.0 A RECP 111,112A, 12
9 1LPL1 100.0 A 3 689 VA 0 VA 1 20.0 A SPARE 10 9 200 VA 1768... 10
8' - 0"
13 RECP 145, 123, 145A 20.0 A 1 100 VA 1130... 1 20.0 A RECP 110, 108 14 AIR CONDITIONING UNIT AC-S102 20.0 A 2 2 25.0 A AIR CONDITIONING UNIT AC-1
15 RECP 124, 144 20.0 A 1 720 VA 1130... 1 20.0 A RECP 108, 106 16 11 1934... 0 VA 1 20.0 A SPARE 12 11 200 VA 1768... 12
17 RECP 144, 143, 140 20.0 A 1 900 VA 1180... 1 20.0 A RECP 106, 104, 103 18 13 3120... 0 VA 1 20.0 A SPARE 14 13 RCPT RECEPTION 100B 20.0 A 1 720 VA 138 VA 1 20.0 A CAB. UNIT HEATERS CUH 1-2, CUH 1-2, CUH... 14
19 RECP 140 20.0 A 1 1860... 590 VA 1 20.0 A RECP 103, 102 20 15 1RPL3 100.0 A 3 3120... 0 VA 1 20.0 A SPARE 16 15 RCPT RECEPTION 100B 20.0 A 1 720 VA 1080... 1 20.0 A RCPT NURSES/MA 141A 16
21 RECP 140 20.0 A 1 540 VA 770 VA 1 20.0 A RECP 102 22 17 720 VA 0 VA 1 20.0 A SPARE 18 17 RCPT NURSES/MA 141A 20.0 A 1 1080... 1080... 1 20.0 A RECP DOCTORS 141C 18
23 REFRIGERATOR, UNDER COUNTER 20.0 A 1 492 VA 1500... 1 20.0 A TABLE TRIAGE 102 24 19 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 20 19 RCPT DOCTORS 141C 20.0 A 1 1080... 1080... 1 20.0 A RCPT NURSES/MA 141B 20
4' - 0"
25 REFRIGERATOR UNDER COUNTER 20.0 A 1 492 VA 1440... 1 20.0 A RECP 109, 107 26
21 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 22 21 RCPT SCSO-01 ALCOVE 1 &2 20.0 A 1 540 VA 1080... 1 20.0 A RCPT NURSES/MA 141B 22
27 RCPT Space 245 20.0 A 1 900 VA 1080... 1 20.0 A RECP 105, P101 28
23 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 24 23 SUMP PUMP ESP-1, FREIGHT ELEVATOR F101 20.0 A 1 900 VA 700 VA 1 20.0 A RCPT REFR. MEDICINE 141 24
29 RECP 132 20.0 A 1 230 VA 720 VA 1 20.0 A RECP 113 30
31 RECEPTACLES Space 203 20.0 A 1 1130... 1080... 1 20.0 A RECP 107A, 100C 32 25 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 26 25 SUMP PUMP ESP-1, PASS. ELEVATOR P101 20.0 A 1 900 VA 700 VA 1 20.0 A RCPT REFR. MEDICINE 141 26
1/4" = 1' - 0"
33 RECP 126 20.0 A 1 1500... 1080... 1 20.0 A RECP 100C, 116 34 27 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 28 27 UNIT HEATER UH-1-1 20.0 A 1 60 VA 700 VA 1 20.0 A RCPT REFR. MEDICINE 141 28
35 RECP 126 20.0 A 1 1680... 900 VA 1 20.0 A RECP 115, CORR 36 29 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 30 29 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 30
0' - 0"
37 RECP 126, 127 20.0 A 1 1620... 1080... 1 20.0 A RECP 100B 38 31 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 32 31 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 32
39 RECP 132 20.0 A 1 770 VA 720 VA 1 20.0 A RECP 100B 40 33 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 34 33 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 34
41 RECEPTACLES Space 213 20.0 A 1 720 VA 1180... 1 20.0 A RECP 114 42 35 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 36 35 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 36
43 RECEPTACLES Space 213 20.0 A 1 720 VA 1080... 1 20.0 A RECP 118, 117 44
37 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 38 37 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 38
45 RECP 128 20.0 A 1 1860... 1500... 1 20.0 A TABLE EXAM 138 46
47 RECP 129 20.0 A 1 720 VA 1500... 1 20.0 A TABLE EXAM 130 48 39 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 40 39 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 40
49 RECP 129 20.0 A 1 720 VA 1440... 1 20.0 A RECP 119, 120 50 41 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 42 41 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 42
24' - 0"
51 RECP 130 20.0 A 1 720 VA 770 VA 1 20.0 A RECP 119A, 122 52 Total Load: 37534 VA 38325 VA 37282 VA Total Load: 7248 VA 8036 VA 6916 VA
53 RECEPTACLES Space 214 20.0 A 1 1130... 1230... 1 20.0 A RECP 100D 54 Total Amps: 313.1 A 319.7 A 310.7 A Total Amps: 60.8 A 67.4 A 57.6 A
55 TABLE EXAM 131 20.0 A 1 1500... 1860... 1 20.0 A TABLE EXAM 137 56 Legend: Legend:
57 RECP 130, 131 20.0 A 1 720 VA 720 VA 1 20.0 A RECP 135, 136 58
59 RECP 130, 131 20.0 A 1 720 VA 720 VA 1 20.0 A RECP 138 60
61 RECP 125, 141 20.0 A 1 900 VA 1500... 1 20.0 A TABLE EXAM 136 62
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
16' - 0"
75 RECPT BARIATRIC EXAM 132 20.0 A 1 720 VA 1080... 1 20.0 A RECEPT ISOLATION RM 128 76 RECEPTACLES 90624 VA 100.00% 90624 VA
77 TABLE EXAM 129 20.0 A 1 1500... 720 VA 1 20.0 A RECPT EXAM 127 78
79 Room 218, 219, 210 20.0 A 1 820 VA 0 VA 1 20.0 A SPARE 80
Notes: Notes:
81 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 82
1/8" = 1' - 0"
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Other 0 VA 0.00% 0 VA
POWER 1810 VA 100.00% 1810 VA
48' - 0"
Notes:
1/16" = 1' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
Drawn AG/TL
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 06/25/2019 ISSUE FOR BID
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
Supply From: DP-02 Phases: 3 Mains Type: MLO Supply From: DP-02 Phases: 3 Mains Type: MLO Supply From: MDP Phases: 3 Mains Type: MAIN CB
Mounting: SURFACE Wires: 4 Mains Rating: 225.0 A Mounting: SURFACE Wires: 4 Mains Rating: 100.0 A Mounting: SURFACE Wires: 4 Mains Rating: 400.0 A
Enclosure: NEMA 1 MCB Rating: Enclosure: NEMA 1 MCB Rating: Enclosure: NEMA 1 MCB Rating: 400.0 A
0' - 3"
Notes: Notes:
3" = 1' - 0"
0' - 0"
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
1 Space 312 20.0 A 1 1310... 330 VA 1 20.0 A RCPT SHARED CONF. RM. 218 2 1 LTG DENTAL CORRIDOR 200D 20.0 A 1 480 VA 640 VA 1 20.0 A EXAM CORRIDOR 200G 2 1 2926... 2926... 2
3 RCPT Space 312 20.0 A 1 460 VA 360 VA 1 20.0 A RCPT Space 307 4 3 LTG CORRIDOR 200B,200E,200C 20.0 A 1 968 VA 1428... 1 20.0 A NURSE/AM & DOCTOR AREAS. 241C 4 3 RTU-1 125.0 A 3 2926... 2926... 3 125.0 A RTU-2 4
5 Space 319 20.0 A 1 330 VA 400 VA 1 20.0 A SIGNAGE 6 5 LTG WAITING AREA & EXTERIOR LTG 20.0 A 1 1450... 528 VA 1 20.0 A EXAM ROMS 223-231 6 5 2926... 2926... 6
7 RCPT Space 319 20.0 A 1 500 VA 680 VA 1 20.0 A RCPT Room 332, 331 8
7 LTG DENTAL EXAM AREA 20.0 A 1 515 VA 120 VA 1 20.0 A UTILITY RMS, 245, 244, 243, 225, 241, 240 8 7 5000... 3333... 8
9 WATER FOUNTAIN 20.0 A 1 600 VA 680 VA 1 20.0 A Space 271 10
3' - 0"
9 LTG PRIVATE OFFICES 20.0 A 1 784 VA 384 VA 1 20.0 A EXAM RMS 232-242 10 9 FREIGHT ELEVATOR 40.0 A 3 5000... 3333... 3 30.0 A PASS ELEVATOR 10
11 RCPT Room 290, 291, 289 20.0 A 1 630 VA 720 VA 1 20.0 A RCPT Dental exam 12
13 RCPT Space 283 20.0 A 1 770 VA 900 VA 1 20.0 A RCPT Space 300 14 11 LTG DENTAL LAB RMS & LABS 20.0 A 1 544 VA 0 VA 1 20.0 A SPARE 12 11 5000... 3333... 12
15 RCPT Space 312 20.0 A 1 900 VA 1000... 1 20.0 A Room 296, 292, 294 16 13 ROOF LIGHTING 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 14 13 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 14
17 RCPT Space 271 20.0 A 1 900 VA 1080... 1 20.0 A RCPT 226 18 15 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 16 15 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 16
19 Room 321, 326 20.0 A 1 1100... 1220... 1 20.0 A RCPT Room 271, 272 20 17 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 18 17 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 18
21 Room 311, 323, 322 20.0 A 1 1140... 1360... 1 20.0 A Room 329, 333 22 19 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 20 19 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 20
2' - 0"
23 RCPT Room 276, 277 20.0 A 1 1170... 1170... 1 20.0 A RCPT Space 276 24 21 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 22 21 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 22
25 COMP Room 305, 306 20.0 A 1 1440... 1910... 1 20.0 A Space 333 26
23 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 24 23 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 24
27 XRAY LIGHT 20.0 A 1 1380... 1460... 1 20.0 A Room 320, 327 28
25 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 26 25 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 26
29 RCPT Space 284 20.0 A 1 1220... 1260... 1 20.0 A Space 309 30
31 Room 297, 311 20.0 A 1 360 VA 540 VA 1 20.0 A RCPT Space 302 32 27 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 28 27 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 28
33 Room 298, 311 20.0 A 1 360 VA 540 VA 1 20.0 A RCPT Space 307 34 29 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 30 29 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 30
1' - 0"
35 Space 324 20.0 A 1 360 VA 1080... 1 20.0 A RCPT Space 312 36 31 32 31 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 32
37 RCPT Space 299 20.0 A 1 540 VA 540 VA 1 20.0 A RCPT Room 278, 275 38 33 34 33 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 34
39 RCPT Space 301 20.0 A 1 540 VA 540 VA 1 20.0 A RCPT Room 334, 282 40 35 36 35 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 36
41 RCPT Space 301 20.0 A 1 540 VA 540 VA 1 20.0 A RCPT Space 280 42 37 38 37 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 38
1" = 1' - 0"
47 RCPT Space 302 20.0 A 1 720 VA 900 VA 1 20.0 A RECPT 234 48 41 42 41 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 42
49 RCPT Space 330 20.0 A 1 900 VA 1080... 1 20.0 A RCPT Dental exam 50 Total Load: 1755 VA 3564 VA 2522 VA Total Load: 66863 VA 66863 VA 66863 VA
51 RECPT 226 20.0 A 1 900 VA 1080... 1 20.0 A RCPT Space 275 52 Total Amps: 14.6 A 30.7 A 22.0 A Total Amps: 241.4 A 241.4 A 241.4 A
53 RECPT 228 20.0 A 1 900 VA 1080... 1 20.0 A RCPT Space 281 54 Legend: Legend:
55 Room 288, 292 20.0 A 1 1130... 1220... 1 20.0 A Room 331 56
57 Room 294, 295 20.0 A 1 1130... 1220... 1 20.0 A Space 273 58
59 Space 334 20.0 A 1 1130... 1220... 1 20.0 A Space 274 60
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
6' - 0"
61 RCPT Space 282 20.0 A 1 1500... 1500... 1 20.0 A RCPT Space 272 62
LITES 7840 VA 100.00% 7840 VA MOTORS 25000 VA 100.00% 25000 VA
63 RCPT Space 283 20.0 A 1 1500... 1500... 1 20.0 A RCPT Space 278 64
Total Conn. Load: 7840 VA Total Conn. Load: 25000 VA
65 RCPT Space 332 20.0 A 1 1500... 1500... 1 20.0 A RCPT Space 280 66
67 RCPT Space 334 20.0 A 1 1860... 1860... 1 20.0 A RCPT Space 276 68 Total Est. Demand: 7840 VA Total Est. Demand: 25000 VA
69 RECEPTACLES Space 272 20.0 A 1 1860... 1860... 1 20.0 A RCPT Space 281 70 Total Conn.: 21.8 A Total Conn.: 30.1 A
71 Space 284 20.0 A 1 1860... 1860... 1 20.0 A RCPT Space 331 72 Total Est. Demand: 21.8 A Total Est. Demand: 30.1 A
4' - 0"
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
0' - 0"
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
1 RCPT 20.0 A 1 720 VA 360 VA 1 20.0 A RCPT 2 1 2745... 9640... 2
3 1872... 720 VA 1 20.0 A RCPT 241A 4 3 2RPL1 250.0 A 3 2771... 1218... 3 250.0 A 2RPL2 4
Notes: ACCU-1 25.0 A 2
5 1872... 180 VA 1 20.0 A RCPT 241 6 5 2407... 9391... 6
4' - 0"
ACCU-4 25.0 A 2
13 1768... 1080... 1 20.0 A RCPT 241C 14 13 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 14
15 1080... 1 20.0 A RCPT 241B 16 15 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 16
0' - 0"
17 REF - 111 20.0 A 1 180 VA 1080... 1 20.0 A RCPT 241B 18 17 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 18
Switchboard: MDP 19 EQUIP 118, 117 20.0 A 1 580 VA 1080... 1 20.0 A RCPT 200B 20 19 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 20
Location: Space 269 Volts: 480Y/277 A.I.C. Rating: 35,000 AMPS SYMMETRICAL 21 2871... 1080... 1 20.0 A RCPT 200B 22 21 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 22
ACCU-3 35.0 A 2
Supply From: ComEd Transformer Phases: 3 Mains Type: MCB 23 2871... 360 VA 1 20.0 A RCPT ALCOVE 3 & 4 24 23 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 24
Mounting: SURFACE Wires: 4 Mains Rating: 800.0 A 25 FAN EF-1, EF-3 20.0 A 1 600 VA 500 VA 1 20.0 A FAN EF-2, EF-5 26 25 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 26
Enclosure: Type 1 MCB Rating: 800A MAIN, 100% RATED 27 FAN EF-119 20.0 A 1 500 VA 1110... 1 20.0 A VAV-1-23 28 27 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 28
24' - 0"
CKT Circuit Description # of Poles Frame Size Trip Rating Load Remarks 41 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 42 41 SPARE 20.0 A 1 0 VA 0 VA 1 20.0 A SPARE 42
1 1TI - 112.5 kVA TRANSFORMER 3 400.0 A 200.0 A 113141 VA Total Load: 9640 VA 12185 VA 9391 VA Total Load: 42505 VA 47118 VA 37242 VA
2 2T1 - 112.5 KVA TRANSFORMER 3 400.0 A 200.0 A 126865 VA Total Amps: 80.7 A 101.9 A 78.3 A Total Amps: 361.0 A 399.4 A 310.4 A
3 1EQH1 3 400.0 A 400.0 A 13961 VA Legend: Legend:
4 2EQH1 3 400.0 A 400.0 A 200588 VA
8' - 0"
5
6 Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
7 POWER 400 VA 100.00% 400 VA POWER 5890 VA 100.00% 5890 VA
1/8" = 1' - 0"
8 MOTORS 1600 VA 100.00% 1600 VA Total Conn. Load: 13340 VA MOTORS 1600 VA 100.00% 1600 VA Total Conn. Load: 108990 VA
9 RECEPTACLES 11340 VA 100.00% 11340 VA Total Est. Demand: 13340 VA LITES 7840 VA 100.00% 7840 VA Total Est. Demand: 108990 VA
0' - 0"
10 Total Conn.: 37.0 A SPEC 4800 VA 100.00% 4800 VA Total Conn.: 302.5 A
11 Total Est. Demand: 37.0 A RECEPTACLES 88860 VA 100.00% 88860 VA Total Est. Demand: 302.5 A
12
13
14 Notes:
15 Notes:
16
48' - 0"
17
18
19
20
Total Conn. Load: 245018 VA
32' - 0"
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Other 0 VA 0.00% 0 VA
POWER 7700 VA 100.00% 7700 VA Total Conn. Load: 245018 VA
1/16" = 1' - 0"
Notes:
120' - 0"
90' - 0"
60' - 0"
Drawn AG/TL
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 06/25/2019 ISSUE FOR BID
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
Location: Space 237 Volts: 208Y/120 A.I.C. Rating: 10,000 AMPS SYMMETRICAL Location: Space 279 Volts: 208Y/120 A.I.C. Rating: 10,000 AMPS SYMMETRICAL
Supply From: DP-01 Phases: 3 Mains Type: MAIN CB Supply From: DP-02 Phases: 3 Mains Type: MLO
Mounting: SURFACE Wires: 4 Mains Rating: 100.0 A Mounting: SURFACE Wires: 4 Mains Rating: 100.0 A
0' - 6"
Notes: Notes:
0' - 3"
3" = 1' - 0"
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
0' - 0"
Total Amps: 29.1 A 29.1 A 6.0 A Total Amps: 33.6 A 33.6 A 10.5 A
Legend: Legend:
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
SPEC 4800 VA 100.00% 4800 VA SPEC 4800 VA 100.00% 4800 VA
6' - 0"
RECEPTACLES 2160 VA 100.00% 2160 VA Total Conn. Load: 19.3 A RECEPTACLES 3780 VA 100.00% 3780 VA Total Conn. Load: 23.8 A
Total Est. Demand: 6960 VA Total Est. Demand: 8580 VA
Total Conn.: 19.3 A Total Conn.: 23.8 A
Total Est. Demand: 19.3 A Total Est. Demand: 23.8 A
4' - 0"
Notes: Notes:
2' - 0"
1/2" = 1' - 0"
0' - 0"
12' - 0"
8' - 0"
4' - 0"
1/4" = 1' - 0"
0' - 0"
24' - 0"
16' - 0"
8' - 0"
1/8" = 1' - 0"
0' - 0"
48' - 0"
32' - 0"
16' - 0"
1/16" = 1' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
Drawn Author
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked Checker 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
06/25/2019
Date
ISSUE FOR BID
Issue
Drawings are not to be scaled.
CONTROLLER.
M M
4' - 0"
0' - 0"
24' - 0"
16' - 0"
CAT5 (TYP)
OCCUPANCY SENSOR OS LS
48' - 0"
CAT5e
LOCAL SWITCH
SEE SHEETS E-201 AND E-202 $ LC
FOR LOCATIONS
TO IT ROOM
16' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
2 03/22/2019 ISSUE FOR 25% CD different than originally drawn. The Owner and Architect Sheet Name
is loaned to the borrower for their confidential use only. In consideration of the loan of this Checked BK 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it 1 01/30/2019 ISSUE FOR DD - REV 01 assume no responsibility for use of incorrect scale.
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part.
0
No.
01/16/2019
Date
ISSUE FOR DD
Issue
Drawings are not to be scaled.
SHALL CONSULT ALL TRADES FURNISHING EQUIPMENT AND OBTAIN FROM THEM ALL DATA
4. ELECTRICAL CONTRACTOR/INSTALLER TO VERIFY (UPON JOB COMPLETION) THAT ALL PERTAINING TO FURNISHED EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL PROVIDE
0' - 0"
CIRCUITS ARE FREE FROM BOTH GROUND AND OPEN CONDITIONS. ALL CONDUIT, WIRING, AND ASSOCIATED HARDWARE AS REQUIRED FOR COMPLETE AND
OPERATING SYSTEMS.
5. ELECTRICAL CONTRACTOR/INSTALLER SHALL NOT DEVIATE FROM DEVICE ADDRESSES AS
ELEVATOR SHAFT
LABELED ON DRAWINGS WITHOUT PRIOR APPROVAL FROM EOR. 3. EQUIPMENT LABELS AND INSTRUCTIONS REGARDING THE APPLICATION AND INSTALLATION
OF THE LISTED EQUIPMENT SHALL BE FOLLOWED TO INSURE THAT THE EQUIPMENT IS
6. ALL AUDIBLE DEVICES SHALL SOUND THE TEMPORAL THREE TONE. BEING INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S LISTING INSTRUCTIONS.
ROOF
THE TEMPERATURE RATING OF THE EQUIPMENT TERMINATIONS MUST BE CAREFULLY
7. ELECTRICAL CONTRACTOR/INSTALLER TO OBSERVE SOUND OUTPUT OF AUDIBLE DEVICES CORRELATED WITH THE CONDUCTOR AMPACITY TO PREVENT OVERHEATING AND
3' - 0"
J TO BE IN COMPLIANCE WITH NFPA 72 SECTION 7.4.2.1* WHEREBY ALL AUDIBLE SIGNALS SHALL PREMATURE FAILURE.
HAVE A SOUND LEVEL AT LEAST 15dB ABOVE THE MAXIMUM SOUND LEVEL.
4. COORDINATE WORK WITH OTHER TRADES AND INSTALL CONDUIT AND BOXES TO CLEAR
VSS
8. IF AT ALL POSSIBLE, WEATHERPROOF AUDIBLE/VISUAL DEVICES SHALL NOT BE INSTALLED CONCEALED PIPING, DUCTS, OPENINGS AND OTHER STRUCTURAL FEATURES, NOT
J WF WHERE DIRECT CONTACT WITH FIRE ELEMENTS MAY OCCUR. CLEARLY NOTED ON THE DRAWING.
2' - 0"
9. WEATHERPROOF AUDIBLE DEVICE CONDUITS AND FITTINGS SHALL BE LIQUID TIGHT., 5. THE BUSINESS OPERATION OF THE BUILDING SHALL NOT BE DISRUPTED DURING THE
INSTALLED IN ACCORDANCE WITH 2005 NEC, ARTICLE 356, SILICON SEALANT OR TEFLON TAPE EXECUTION OF THIS WORK WITHOUT PRIOR NOTIFICATION AND APPROVAL BY THE
SHALL BE USED ON ALL THREADED PIPE, FITTINGS, & PLUGS & THE BACK OF BOX MEETING OWNER.
THE WALL SHALL ALSO BE SEALED WITH SILICON SEALANT.
J SV SV QTY. AS REQUIRED SV SV P SD SD 6. THIS ELECTRICAL CONTRACTOR SHALL FIRESTOP ALL PENETRATIONS (DUE TO THEIR
10. FIELD INSTALLED DEVICES SHALL NOT BE HAND MARKED FOR ANY REASON; FOR THE CONDUIT ROUTINGS) THROUGH FIRE-RATED WALLS, FLOORS AND CEILINGS.
PURPOSE OF DISPLAYING THE DEVICE ADDRESS OR OTHER PERTINENT INFORMATION, USE A
1' - 0"
P-TOUCH LABEL OR EQUIVALENT. 7. THIS ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING
SECOND FLOOR RELATED TO HIS WORK. ELECTRICAL CONTRACTOR SHALL PATCH ALL UNUSED OPENINGS
11. ALL BATTERIES TO BE PERMANENTLY MARKED WITH THE MONTH AND YEAR OF (CREATED BY HIS WORK) TO MATCH SURROUNDING CONDITIONS. ANY UNUSED SOURCES
CLASS-A FEED CLASS-A RETURN MANUFACTURE, USING THE MM/YYYY FORMAT. FROM DEMOLITION WORK MUST BE REMOVED COMPLETELY.
1" = 1' - 0"
VSS BRANCH CIRCUIT. METALLIC CONDUIT AND LIQUID FLEXIBLE STEEL CONDUIT SHALL NOT EXCEED 6 FEET IN
J WF LENGTH.
13. PRIMARY POWER CIRCUITS FOR ALL FIRE ALARM EQUIPMENT SHALL BE MECHANICALLY
J PROTECTED WITH A BREAKER LOCK. 9. ALL WIRING SHALL BE INSTALLED IN RIGID METAL CONDUIT, INTERMEDIATE METAL
J
CONDUIT, ELECTRICAL METALLIC TUBING OR SURFACE METAL RACEWAY.
14. PRIMARY POWER DISCONNECTING MEANS SHALL HAVE A RED MARKING, SHALL BE
VSS VSS POWER ON
FIRE MONITORING FIRE ALARM NAC ELEVATOR ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL & SHALL BE IDENTIFIED AS "FIRE ALARM
VSS VSS POWER FAILURE
PUMP SRVC. CO. P CONTROL PANEL CONTROLLER CIRCUIT."
6' - 0"
VSS VSS
3 PANEL REVERSING
WF WF
5 4 15. THE LOCATION OF THE PRIMARY POWER DISCONNECTING MEANS SHALL BE PERMANENTLY ALL 2 HOUR PROTECTION FOR RISERS (VERTICAL OR HORIZONTAL) SHALL BE PER CITY
BATT. 1LSL1: CKT 42 , LOCK-OUT IDENTIFIED AT THE FIRE ALARM CONTROL PANEL. OF CHICAGO ELECTRICAL CODE ARTICLE 760 18-27-760.82.E
CAB WITH 2#12, 1#12GRND, 3/4"C.
FIRST FLOOR
16. PRIMARY POWER SHALL NOT BE APPLIED (TURNED ON) TO THE FIRE ALARM CONTROL PANEL (E) PROTECTION. RACEWAY SYSTEM SHALL BE PROTECTED TO MINIMIZE PHYSICAL
ELEVATOR SHAFT OR ANY OTHER FIRE ALARM POWER SUPPLIES UNLESS THERE IS A FIRE ALARM DAMAGE. WHERE OTHER SECTIONS OF CHICAGO BUILDING CODE REQUIRE PROTECTION
ELEVATOR LOBBY 1 & 2 STAIR N1 STAIR S1
4' - 0"
REPRESENTATIVE PRESENT. FROM FIRE, RACEWAY SYSTEM SHALL FOLLOW ONE OF METHODS BELOW.
TYPICAL
17. DETECTOR SPACING IS BASED ON SMOOTH CEILINGS. IF ANY BEAM, JOIST, PEAKED, OR SHED (1.) RUN WITHIN A ROOM(S) OR AREA(S) DEDICATED TO PROTECTION OF ELECTRICAL
CEILINGS EXIST, COORDINATE WITH EOR FOR CORRECT SPACING GUIDELINES. EQUIPMENT, MEETING FIRE RESISTANCE CONSTRUCTION RATING OF SPECIFYING
SECTION OF CHICAGO BUILDING CODE.
18. FIELD VERIFY THAT DETECTORS ARE MOUNTED AT LEAST THREE FEET AWAY FROM ANY AIR
SUPPLY DIFFUSER, RETURN AIR OPENING OR SPRINKLER HEAD. (2.) PROTECTED BY AN ELECTRICAL CIRCUIT PROTECTIVE SYSTEM LISTED TO MEET UL
2' - 0"
INSTALLATION SHALL UTILIZE 2-HOUR FIRE RATED CABLE TO MEET THE FIRE RESISTIVE
REQUIREMENTS OF 18-27-760.82.E
12' - 0"
(CEILING)
SV V
8' - 0"
SPEAKER- STROBE
6" 6" STROBE 30'
(MIN.) (MIN.) 30' (A.F.F.)
(A.F.F.)
4' - 0"
SV V
SPEAKER- STROBE
STROBE
FACP
1/4" = 1' - 0"
CEILING
HEIGHT PULL NAC
72"
STATION
0' - 0"
(FINISHED FLOOR)
MOUNTING HEIGHTS
16' - 0"
NOT TO SCALE
0' - 0"
48' - 0"
32' - 0"
16' - 0"
1/16" = 1' - 0"
0' - 0"
120' - 0"
90' - 0"
60' - 0"
Drawn Author
Notice: This drawing has not been published and is the sole property of Cook County. It This drawing copy may have been reproduced at a size
1" = 30' - 0"
is loaned to the borrower for their confidential use only. In consideration of the loan of this different than originally drawn. The Owner and Architect Sheet Name
assume no responsibility for use of incorrect scale. Checked Checker 5501 W FULLERTON AVE
drawing, the borrower promises and agrees to return it upon request and agrees that it
0' - 0"
CHICAGO, IL 60639
shall not be reproduced, copied, loaned, or otherwise disposed of directly or indirectly,
nor used for any purpose other than for which it is furnished, in whole or part. No. Date Issue
Drawings are not to be scaled.
Cisco Spark Board-70" LED Display Crestron Room Scheduling Touch Screen
(SPARK-BOARD70) (TSS-7)
SHARED
CONFERENCE
GB
WALL MOUNTED TV ROOM
218
1'-3"
11"
3'-416 CL
7"
1'-216
GB
CL
1'-8"
6'-6"
1"
4'-112
11"
4'-916
4'
1-Gang j-box w/ 1” conduit from back box to j-box
5"
3'-116
(Supplied by Electrical Contractor)
CL CL
1"
2'-816 1"
2'-816 1'
1"
5'-48
7"
8'-016 7"
8'-716 CLIENT NAME
Cook County-Hanson Park
16'-77
8"
ADDRESS
Shared Conference Room #218- Floor Plan Shared Conference Room #218- North Wall Elevation Outside Wall Elevation CITY/STATE/ZIP
SCALE DATE
As Noted 3/27/19
REV DATE REV DATE
3/28/19
REV DATE REV DATE
DESCRIPTION
Cook County-Hanson Park
Shared Conference Room #218
Floor Plan and Wall Elevation
DRAWING #
A/V-A101
7699 Lochlin Drive, Brighton, Michigan 48116
Ph: 248.437.0041 F: 248.437.0052
EDUCATION
ROOM
114
2.3
2.4 2.1
2.2
Cisco Spark Board-70" LED Display
(SPARK-BOARD70)
GB
8'-73" 8'-73"
8 8 (1) 1-Gang Data Plate in Storage Box
17'-27 3"
(Supplied by Electrical Contractor)
8"
4'-016
Chief Storage Box (PAC526)
Education Room #114- Floor Plan 1" Empty conduit to accessible ceiling
(Supplied by Electrical Contractor)
(Supplied by Electrical Contractor)
Scale: 1/2"=1'-0"
Cisco Wall Mount (1) 120v Duplex Outlet in Storage Box
Crestron Room Scheduling Touch Screen (TSS-7) (SPARK-BOARD70-WMK) (Supplied by Electrical Contractor)
w/ 2-Gang j-box and conduit to accessible ceiling
(Supplied by Electrical Contractor) Cisco Spark Board-70" LED Display Display Backing-3/4" Plywood
(SPARK-BOARD70) (Supplied by General Contractor)
1'-3"
11"
3'-416 CL
7"
1'-216
GB
CL
1'-8"
6'-6"
1"
4'-112 4'-911" CLIENT NAME
16
Cook County-Hanson Park
4' ADDRESS
1-Gang j-box w/ 1” conduit from back box to j-box
(Supplied by Electrical Contractor) 3'-1 5 "
16 CITY/STATE/ZIP
ENGINEER DRAWN BY
MN MJD-SVT Equip.
APPROVED BY PROJECT NUMBER
SCALE DATE
CL CL
As Noted 3/27/19
1"
2'-816 1"
2'-816 REV DATE REV DATE
1'
3/28/19 4/23/19
5"
12'-78 1"
9'-02 REV DATE REV DATE
3"
4'-016 17'-27"
8 DESCRIPTION
Cook County-Hanson Park
1"
21'-88 Education Room #114
Floor Plan and Wall Elevations
Outside Wall Elevation Education Room #114- South Wall Elevation DRAWING #