Project : RIYAN Sheet No: 1

Site : Date :
Room : STORE Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 2600 Sq.ft
Wall Height 16.4 Feet
Occupants 20 Persons
Fresh Air per person 20 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 5 kW
Terminal Heater 0
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 1613 Sq.ft
East 420 Sq.ft
West 420 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 2600 Sq.ft
Floor 2600 Sq.ft
Project : Sheet No: 2
Site : Date :
Room : wherhouse2 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 10273 Sq.ft
Wall Height 29.5 Feet
Occupants 50 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 33 kW
Terminal Heater
Pre Heater 0
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 2335 Sq.ft
South East 0 Sq.ft
South West 2335 Sq.ft
North West 0 Sq.ft
Roof 10273 Sq.ft
Glass 0 Sq.ft
Partition
Wall 3837 Sq.ft
Ceiling 10273 Sq.ft
Floor 10273 Sq.ft
Project : Sheet No: 3
Site : Date :
Room : office1 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 1141 Sq.ft
Wall Height 10 Feet
Occupants 15 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 1 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 259 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 778 Sq.ft
South East 142 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 1141 Sq.ft
Glass 0 Sq.ft
Partition
Partition
Wall 0 Sq.ft
Ceiling 1141 Sq.ft
Floor 1141 Sq.ft
Project : Sheet No: 4
Site : Date :
Room : OFFICE2 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 1141 Sq.ft
Wall Height 10 Feet
Occupants 15 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 1 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 259 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 778 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 1141 Sq.ft
Glass 0 Sq.ft
Partition
Partition
Wall 0 Sq.ft
Ceiling 1141 Sq.ft
Floor 1141 Sq.ft
Project : Sheet No: 5
Site : Date :
Room : 5 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 6
Site : Date :
Room : 6 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 7
Site : Date :
Room : 7 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 8
Site : Date :
Room : 8 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 9
Site : Date :
Room : 9 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 10
Site : Date :
Room : 10 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 11
Site : Date :
Room : 11 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 12
Site : Date :
Room : 12 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 13
Site : Date :
Room : 13 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 14
Site : Date :
Room : 14 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 15
Site : Date :
Room : 15 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 16
Site : Date :
Room : 16 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 17
Site : Date :
Room : 17 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 18
Site : Date :
Room : 18 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 19
Site : Date :
Room : 19 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 20
Site : Date :
Room : 20 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 21
Site : Date :
Room : 21 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 22
Site : Date :
Room : 22 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 23
Site : Date :
Room : 23 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 24
Site : Date :
Room : 24 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
0

Project : Sheet No: 25


Site : Date :
Room : 25 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 26
Site : Date :
Room : 26 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 27
Site : Date :
Room : 27 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 28
Site : Date :
Room : 28 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 29
Site : Date :
Room : 29 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
Project : Sheet No: 30
Site : Date :
Room : 30 Prep. By:
Floor : Grid No:
Est.For : Summer Above:
Site & Season Code 1 Below:

ROOM DESCRIPTION AND DATA SHEET


Area 0 Sq.ft
Wall Height 10 Feet
Occupants 0 Persons
Fresh Air per person 15 CFM
Room Details
Light per Sq.ft Area 1.5 Watts
Appliances 0 kW
Terminal Heater
Pre Heater
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Glass
North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
North 0 Sq.ft
South 0 Sq.ft
East 0 Sq.ft
West 0 Sq.ft
Exposed Wall & Roof North East 0 Sq.ft
South East 0 Sq.ft
South West 0 Sq.ft
North West 0 Sq.ft
Roof 0 Sq.ft
Glass 0 Sq.ft
Partition
Wall 0 Sq.ft
Ceiling 0 Sq.ft
Floor 0 Sq.ft
GREEN TECH GMC LLC
Zone : TM/
Project : | Sheet No: 1 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : STORE | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 16.40 2600 42640 0.6 20 400
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
Area BTU/Hr/sq.ft. Watts/sq.m | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF 0.94
EAST 0.00 0 3.15 0.00 0 | ADP 54.55
WEST 0.00 0 3.15 0.00 0 | CFM 8337
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 1613 22 0.36 12775 | LOAD 13.56 TR
EAST 420 28 0.36 4234 | AIR 8337 cfm
WEST 420 26 0.36 3931 | ADP 54.55 F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR 192
PARTITION (W) 0 0 0.00 0 |
CEILING 2600 21 0.40 21840 | CFM/TR 615
FLOOR 2600 21 0.48 26208 | CFM/SFT 3.21
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 400 26 0.12 1.08 1348 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 122412
PEOPLE 20 245 4900 | RLH 7571
LIGHTS 1.5 2600 1.25 3.4 16575 | RTH 129983
APPLIANCE 5.0 1 3400 17000 | GTH 162678
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 108811 | TR 13.56
ADD : 5% Safety+ADD FAN 7.5% 13601 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 122412 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 400 95 0.12 0.68 3111 | NOTES :
PEOPLE 20 205 4100 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED 71.25
SUB TOTAL ROOM LATENT HEAT 7211 | LD 56.55
ADD : 5% Safety 361 |
TOTAL ROOM LATENT HEAT 7571 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 129983 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 400 26 0.88 1.08 9884 |
OA Latent 400 95 0.88 0.68 22811 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 13.56 TR 162678 |
----------------------------------------------------------------------------------
GREEN TECH GMC LLC
TM/
Project : | Sheet No: 2 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : wherhouse2 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 29.50 10273 303054 0.1 50 750
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF 0.97
EAST 0.00 0 3.15 0.00 0 | ADP 54.98
WEST 0.00 0 3.15 0.00 0 | CFM 39899
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 53.98 TR
EAST 0 0 0.00 0 | AIR 39899 cfm
WEST 0 0 0.00 0 | ADP 54.98 F
NORTH EAST 2335 24 0.30 16812 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 2335 25 0.30 17513 |
NORTH WEST 0 0 0.00 0 |
ROOF 10273 27 0.24 65460 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR 190
PARTITION (W) 3837 21 0.30 24173 |
CEILING 10273 21 0.40 86293 | CFM/TR 739
FLOOR 10273 21 0.48 103552 | CFM/SFT 3.88
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 750 26 0.12 1.08 2527 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 569553
PEOPLE 50 245 12250 | RLH 16886
LIGHTS 1.5 10273 1.25 3.4 65490 | RTH 586440
APPLIANCE 33 1 3400 112200 | GTH 647743
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 506270 | TR 53.98
ADD : 5% Safety+ADD FAN 7.5% 63284 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 569553 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 750 95 0.12 0.68 5832 | NOTES :
PEOPLE 50 205 10250 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED 70.49
SUB TOTAL ROOM LATENT HEAT 16082 | LD 56.84
ADD : 5% Safety 804 |
TOTAL ROOM LATENT HEAT 16886 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 586440 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 750 26 0.88 1.08 18533 |
OA Latent 750 95 0.88 0.68 42771 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 53.98 TR 647743 |
----------------------------------------------------------------------------------
GREEN TECH GMC LLC
TM/
Project : | Sheet No: 3 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : office1 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 1141 11410 1.2 15 225
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF 0.94
EAST 0.00 0 3.15 0.00 0 | ADP 54.55
WEST 0.00 0 3.15 0.00 0 | CFM 5356
NORTH EAST 24.06 100 3.15 315.20 21971 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 8.51 TR
EAST 0 0 0.00 0 | AIR 5356 cfm
WEST 0 0 0.00 0 | ADP 54.55 F
NORTH EAST 778 24 0.36 6722 |
SOUTH EAST 142 26 0.36 1329 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 1141 27 0.12 3697 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR 134
PARTITION (W) 0 0 0.00 0 |
CEILING 1141 21 0.40 9584 | CFM/TR 629
FLOOR 1141 21 0.48 11501 | CFM/SFT 4.69
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 225 26 0.12 1.08 758 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 78651
PEOPLE 15 245 3675 | RLH 5066
LIGHTS 1.5 1141 1 3.4 7274 | RTH 83717
APPLIANCE 1.0 1 3400 3400 | GTH 102108
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 69912 | TR 8.51
ADD : 5% Safety+ADD FAN 7.5% 8739 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 78651 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 225 95 0.12 0.68 1750 | NOTES :
PEOPLE 15 205 3075 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED 71.09
SUB TOTAL ROOM LATENT HEAT 4825 | LD 56.54
ADD : 5% Safety 241 |
TOTAL ROOM LATENT HEAT 5066 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 83717 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 225 26 0.88 1.08 5560 |
OA Latent 225 95 0.88 0.68 12831 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 8.51 TR 102108 |
----------------------------------------------------------------------------------
GREEN TECH GMC LLC
TM/
Project : | Sheet No: 4 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : OFFICE2 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 1141 11410 1.2 15 225
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF 0.94
EAST 0.00 0 3.15 0.00 0 | ADP 54.55
WEST 0.00 0 3.15 0.00 0 | CFM 5255
NORTH EAST 24.06 100 3.15 315.20 21971 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 8.38 TR
EAST 0 0 0.00 0 | AIR 5255 cfm
WEST 0 0 0.00 0 | ADP 54.55 F
NORTH EAST 778 24 0.36 6722 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 1141 27 0.12 3697 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR 136
PARTITION (W) 0 0 0.00 0 |
CEILING 1141 21 0.40 9584 | CFM/TR 627
FLOOR 1141 21 0.48 11501 | CFM/SFT 4.61
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 225 26 0.12 1.08 758 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 77156
PEOPLE 15 245 3675 | RLH 5066
LIGHTS 1.5 1141 1 3.4 7274 | RTH 82222
APPLIANCE 1 1 3400 3400 | GTH 100613
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 68583 | TR 8.38
ADD : 5% Safety+ADD FAN 7.5% 8573 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 77156 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 225 95 0.12 0.68 1750 | NOTES :
PEOPLE 15 205 3075 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED 71.11
SUB TOTAL ROOM LATENT HEAT 4825 | LD 56.54
ADD : 5% Safety 241 |
TOTAL ROOM LATENT HEAT 5066 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 82222 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 225 26 0.88 1.08 5560 |
OA Latent 225 95 0.88 0.68 12831 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 8.38 TR 100613 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 5 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 5 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 6 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 6 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 7 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 7 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 8 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 8 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 9 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 9 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 10 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 10 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 11 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 11 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 12 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 12 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 13 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 13 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 14 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 14 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 15 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 15 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ----------------------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 16 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 16 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 17 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 17 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 18 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 18 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 19 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 19 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 20 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 20 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0 0 3.15 0.00 0 |
SOUTH 0 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0 0 3.15 0.00 0 |
SOUTH EAST 0 0 3.15 0.00 0 |
SOUTH WEST 0 0 3.15 0.00 0 |
NORTH WEST 0 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 21 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 21 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 22 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 22 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 23 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 23 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 24 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 24 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 25 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 25 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 26 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 26 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 27 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 27 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 28 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 28 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 29 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 29 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
AIR TREATMENT ENGINEERING PVT. LTD. CHENNAI-20.
TM/
Project : | Sheet No: 30 Date :
Site : |------ --------------------- ------------------ ---------------- ---------------
Room : 30 | DBT WBT RH GR/LB
Floor : | ODC 96 78 80 116
Est.For : Summer | IDC 70 0 50 21
| Diff 26 95
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
L B H Area Volume AC/Hr Occup. F Air
Dimension : 0.00 0.00 10.00 0 0 #DIV/0! 0 0
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR GAIN FROM GLASS BTU/HR | WORKINGS
NORTH 0.00 0 3.15 0.00 0 |
SOUTH 0.00 0 3.15 0.00 0 | SHF #DIV/0!
EAST 0.00 0 3.15 0.00 0 | ADP #DIV/0!
WEST 0.00 0 3.15 0.00 0 | CFM #DIV/0!
NORTH EAST 0.00 0 3.15 0.00 0 |
SOUTH EAST 0.00 0 3.15 0.00 0 |
SOUTH WEST 0.00 0 3.15 0.00 0 |
NORTH WEST 0.00 0 3.15 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
SOLAR & TRAN. FROM WALL & ROOF | SUMMARY
NORTH 0 0 0.00 0 |
SOUTH 0 0 0.00 0 | LOAD 0.00 TR
EAST 0 0 0.00 0 | AIR #DIV/0! cfm
WEST 0 0 0.00 0 | ADP #DIV/0! F
NORTH EAST 0 0 0.00 0 |
SOUTH EAST 0 0 0.00 0 |
SOUTH WEST 0 0 0.00 0 |
NORTH WEST 0 0 0.00 0 |
ROOF 0 0 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
TRANSMISSION GAIN | CHECK FIGURE
|
PARTITION (G) 0 0 0.00 0 | AREA/TR #DIV/0!
PARTITION (W) 0 0 0.00 0 |
CEILING 0 0 0.00 0 | CFM/TR #DIV/0!
FLOOR 0 0 0.00 0 | CFM/SFT #DIV/0!
-------------------------------- ------------------ ------- ------- -------------- --------------------- ------------------ ---------------- ---------------
INFILTRATION 0 | LOAD SUMMARY
OUTSIDE AIR 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | RSH 0
PEOPLE 0 0 0 | RLH 0
LIGHTS 1.5 0 1.25 3.4 0 | RTH 0
APPLIANCE 0.0 0 0 0 | GTH 0
TERMINAL HEATERS 0 0 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
SUB TOTAL ROOM SENSIBLE HEAT 0 | TR 0.00
ADD : 5% Safety+ADD FAN 7.5% 0 |
PREHEATERS 0 0 0 0 0 |
TOTAL ROOM SENSIBLE HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
INFILTRATION 0 |-------- ---------------- ---------------
OUTSIDE AIR 0 0 0.00 0.00 0 | NOTES :
PEOPLE 0 0 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | ED #DIV/0!
SUB TOTAL ROOM LATENT HEAT 0 | LD #DIV/0!
ADD : 5% Safety 0 |
TOTAL ROOM LATENT HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
ROOM TOTAL HEAT 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- | Offer :
OA Sensible 0 0 0.00 0.00 0 |
OA Latent 0 0 0.00 0.00 0 |
-------------------------------- ------------------ ------- ------- -------------- --------------------- |
GRAND TOTAL HEAT 0.00 TR 0 |
----------------------------------------------------------------------------------
STORE Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

NORTH 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 614.95122

SOUTH 0 12774.96 0 0 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 614.95122

EAST 0 4233.6 0 0 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 614.95122

WEST 0 3931.2 0 0 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 614.95122

NORTH EAST 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 614.95122

SOUTH EAST 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 614.95122

SOUTH WEST 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 614.95122

NORTH WEST 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 614.95122


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

wherhouse2 NORTH 0 0 0 0 0 0 #DIV/0! 0 #DIV/0! 739.1565

SOUTH 0 0 0 0 0 0 #DIV/0! 0 #DIV/0! 739.1565

EAST 0 0 0 0 0 0 #DIV/0! 0 #DIV/0! 739.1565

WEST 0 0 0 0 0 0 #DIV/0! 0 #DIV/0! 739.1565

NORTH EAST 0 16812 0 0 0 0 #DIV/0! 0 #DIV/0! 739.1565

SOUTH EAST 0 0 0 0 0 0 #DIV/0! 0 #DIV/0! 739.1565

SOUTH WEST 0 17512.5 0 0 0 0 #DIV/0! 0 #DIV/0! 739.1565

NORTH WEST 0 0 0 0 0 0 #DIV/0! 0 #DIV/0! 739.1565


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

office1 NORTH 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 629.49319

SOUTH 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 629.49319

EAST 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 629.49319

WEST 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 629.49319

NORTH EAST 21971.485 6721.92 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 629.49319

SOUTH EAST 0 1329.12 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 629.49319

SOUTH WEST 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 629.49319

NORTH WEST 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 629.49319


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

OFFICE2 NORTH 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 626.70307

SOUTH 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 626.70307

EAST 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 626.70307

WEST 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 626.70307

NORTH EAST 21971.485 6721.92 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 626.70307

SOUTH EAST 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 626.70307

SOUTH WEST 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 626.70307


NORTH WEST 0 0 0 0 0 0 #DIV/0! #DIV/0! #DIV/0! 626.70307
Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR
5 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

6 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

7 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR
8 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

9 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

10 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

11 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

12 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

13 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

14 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

15 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR
16 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

17 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

18 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

19 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR
20 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

21 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

22 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

23 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR
24 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

25 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

26 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

27 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR
28 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

29 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


Btu---> Glass Wall People Equip. Floor Roof PA-G PA-W TR in Btu cfm/TR

30 NORTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH EAST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

SOUTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

NORTH WEST 0 0 #DIV/0! 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!


6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
#DIV/0!
6ft cfm
#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm
#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!
#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm
#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
#DIV/0!
6ft cfm
#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm
#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
#DIV/0!
6ft cfm
#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
6ft cfm

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
Project:
Client:

Heat Load Summary


VPS
Area Lights Appliances Fresh
Sl No: DESCRIPTION occ Deh.CFM SHF ADP TR EDB LDB Area/TR cfm/TR
(Sq.ft) (Watt/Sqft) (kW) CFM

1 WAREHOUSE 1 2600 20 1.5 5.0 8337 400 0.94 54.55 13.56 71.25 56.55 192 615
2 WAREHOUSE 2 10273 50 1.5 33.0 39899 750 0.97 54.98 53.98 70.49 56.84 190 739
Design Considerations
Occupancy:50 Glass : SF = &U= W/m2 0K
Equipment: 150 Watts/computer
Light:1.5 Watts/sq.ft Wall Height: Outside(DBT & WBT ) in Deg F :115 & 75
FA cfm: 1 cfm/person for Offices Glass height: Inside(DBT & RH) : 70 Deg F & 50%
: 5 cfm/person + 0.06 cfm/sq.ft x area Heat Recovery : Not Considered

Last Modified: Architect:


Ver: HVAC:Air Treatment Engg. Pvt. Ltd.,
Project:
Client:

cfm/sq.ft

3.2
3.9

Last Modified: Architect:


Ver: HVAC:Air Treatment Engg. Pvt. Ltd.,
Number of
similar
Sl No Room Direction Area (sq.m) Load (btu/Hr) TR Glass Code rooms TR Area
1 STORE NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
2 wherhouse NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
3 office1 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 24.0616871 21971.485348 1.830957112 11 1 1.83095711 24.0616871
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
4 OFFICE2 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 24.0616871 21971.485348 1.830957112 11 1 1.83095711 24.0616871
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
5 5 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0

NORTH WEST 0 0 0 11 1 0 0
6 6 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
7 7 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
8 8 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
9 9 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
10 10 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
11 11 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
12 12 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
13 13 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
14 14 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
15 15 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
16 16 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
17 17 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
18 18 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
19 19 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
20 20 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
21 21 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
22 22 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
23 23 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
24 24 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
25 25 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
26 26 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
27 27 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
28 28 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
29 29 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
30 30 NORTH 0 0 0 11 1 0 0
SOUTH 0 0 0 11 1 0 0
EAST 0 0 0 11 1 0 0
WEST 0 0 0 11 1 0 0
NORTH EAST 0 0 0 11 1 0 0
SOUTH EAST 0 0 0 11 1 0 0
SOUTH WEST 0 0 0 11 1 0 0
NORTH WEST 0 0 0 11 1 0 0
Glass Load Summary-Direction wise
Direction Glass Area( sq.m) Load (btu/Hr) TR
NORTH 0 0 0 Equipment cost/TR 45000 Rs
SOUTH 0 0 0 Operating cost/TR/Hr 6 Rs
EAST 0 0 0 Number Hrs/Day 16 Rs
WEST 0 0 0 Number Days/Year 360 Rs
NORTH EAST 48.1233742103307 43942.970696 3.66191422 Maintanance Cost/year/TR 1000 Rs
SOUTH EAST 0 0 0
SOUTH WEST 0 0 0
NORTH WEST 0 0 0
Total 48.1233742103307 43942.970696 3.66191422

Glass Load Summary-Glass Type wise


Glass Type Glass Code Glass Area(sq.m) TR Rs/Sq.m GlassCost Equip.cost First Cost Opera+Maintance cost
DGU ST 408 1 0 0 3295 0 0 0 0
Ref Green 2 0 0 1330 0 0 0 0
ST 408 3 0 0 2134 0 0 0 0
DGU Green 4 0 0 2470 0 0 0 0
green laminate 5 0 0 2509 0 0 0 0
DGU skyblue 6 0 0 2533 0 0 0 0
ST Blue 7 0 0 2027 0 0 0 0
DGU ST blue 8 0 0 3230 0 0 0 0
low e 9 0 0 2723 0 0 0 0
Ordinary Glass 6mm 10 0 0 400 0 0 0 0
Ordinary Plain Glass-DG 11 48.1233742103307 3.6619142246 1400 67372.7239 164786.1401 232158.9 130217.669828361
Deep Blue 12 0 0 4440 0 0 0 0
Ultra Marine 13 0 0 4380 0 0 0 0
Marine Blue 14 0 0 4560 0 0 0 0
SGG Climailit 15 0 0 3707 0 0 0 0
Titanium Blue 16 0 0 0 0 0 0 0
Tinted Glass 17 0 0 0 0 0 0 0
18 0 0 0 0 0 0 0
19 0 0 0 0 0 0 0
20 0 0 0 0 0 0 0
21 0 0 0 0 0 0 0
22 0 0 0 0 0 0 0
23 0 0 0 0 0 0 0
24 0 0 0 0 0 0 0
25 0 0 0 0 0 0 0
67372.7239 164786.1401 232158.9 130217.669828361
0.67372724 1.647861401 2.321589 1.30217669828361
Glass Type Glass Code GlassCost Equip.cost First Cost Opera+Maintance cost TR
DGU ST 408 1 0
Ref Green 2 0
ST 408 3 0
DGU Green 4 0
green laminate 5 0
DGU skyblue 6 0
ST Blue 7 0
DGU ST blue 8 0
low e 9 0
Ordinary Glass 10 0
Ordinary Plain 11 3.661914
Deep Blue 12 0
Ultra Marine 13 0
Marine Blue 14 0
SGG Climailit 15 0
Titanium Blue 16 0
Tinted Glass 17 0

You might also like