NA2XY 0,6/1 kV; Double or Triple; DNC-ET-094a Contact

NA2XY 0,6/1 kV 3-1x185 mm2 Local Sales


ventas.peru@nexans.com

Nexans Ref.: P00002161-5

General use as power cable, for fixed installations.

DESCRIPTION
Application:

General use as power cable. In low voltage distribution networks, industrial


installations, buildings and operating centers. For fixed installations, in indoor areas
(trays, ducts), in underground ducts or buried direct in ground, in dry or wet locations.

Construction:

1. Conductor: Compact aluminium 1350, class 2.

2. Insulation: Cross linked polyethylene XLPE. STANDARDS


3. Outer sheath: Compound polyvinyl chloride PVC. International IEC 60228;
IEC 60332-1-2; IEC 60502-1;
4. Tape: Polyester tape.
IEC 60811-401; IEC 60811-402;
Main characteristics: IEC 60811-409; IEC 60811-501;
IEC 60811-502; IEC 60811-504;
Good electrical and mechanical properties. Cross-linked polyethylene insulation allows IEC 60811-505; IEC 60811-506;
greater power capacity under any operating condition, minimum dielectric losses, high IEC 60811-507; IEC 60811-508;
insulation resistance. The PVC outer sheath allows an adequate resistance to greases, IEC 60811-509
oils, abrasion and sunlight. Flame retardant.
National ICEA S-95-658; NTP-
Cross section: IEC 60228; NTP-IEC 60502-1;
UL 2556
From 10 mm2 up to 1000 mm2.

Marking:

INDECO S.A. NA2XY 0,6/1 kV - (2 or 3) - 1 x Section - Year - Sequential length.

Packing:

Non returnable wooden reels.

Colour:

Insulation: Natural.

Outer sheath: White and black or white, black and red.

National standards

NTP-IEC 60228: Conductors of insulated cables.

Lead free Rated Voltage Uo/U Cable flexibility U.V resistance Flame retardant Oil resistance Maximum operating
Yes (Um) Class 2 IEC 60228 UL 2556 - Sunlight IEC 60332-1-2; FT1 ICEA S-95-658 temperature
0.6/ 1 (1.2) kV Resistance 90 °C

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is
indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Generated 11/6/21 www.nexans.pe Page 1 / 4
NA2XY 0,6/1 kV; Double or Triple; DNC-ET-094a Contact
NA2XY 0,6/1 kV 3-1x185 mm2 Local Sales
ventas.peru@nexans.com

NTP-IEC 60502-1: Power cables with extruded insulation and their accessories for
rated voltages from 1 kV and 3 kV.

DNC-ET-094a:Luz del Sur Standard - Cable with XLPE insulated NA2XY Underground
network L.V. 220 V.

International standards

IEC 60228: Conductors of insulated cables.

IEC 60502-1: Power cables with extruded insulation and their accessories for rated
voltages from 1 kV and 3 kV.

IEC 60332-1-2: Test for vertical flame propagation for a single insulated wire or cable -
Procedure for 1 kW pre-mixed flame.

UL 2556: Wire and Cable Test Methods. Section 9.3: FT1 (Vertical-Specimen) Flame
Test.

IEC 60811-401:Thermal ageing methods-Ageing in an air oven.

IEC 60811-402: Water absorption test.

IEC 60811-409: Loss of mass test for thermoplastic insulations and sheaths.

IEC 60811-501: Test for determining the mechanical properties of insulating and
sheathing.

IEC 60811-502: Shrinkage test for insulations.

IEC 60811-504: Bending test at low temperature for insulation and covers.

IEC 60811-505: Low temperature elongation test for insulations and covers.

IEC 60811-506: Impact test at low temperature for insulations and covers.

IEC 60811-507: Hot set test for cross-linked materials.

IEC 60811-508: High temperature pressure tests for insulations and covers.

IEC 60811-509: Tests of resistance to cracking of the insulations and covers (thermal
shock).

ICEA S-95-658: Power cables rated 2000 volts or less for the distribution of electrical
energy. Section 6.4.2: Oil: Oil Immersion Test.

UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc
Tests- Sunlight resistance.

Lead free Rated Voltage Uo/U Cable flexibility U.V resistance Flame retardant Oil resistance Maximum operating
Yes (Um) Class 2 IEC 60228 UL 2556 - Sunlight IEC 60332-1-2; FT1 ICEA S-95-658 temperature
0.6/ 1 (1.2) kV Resistance 90 °C

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is
indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Generated 11/6/21 www.nexans.pe Page 2 / 4
NA2XY 0,6/1 kV; Double or Triple; DNC-ET-094a Contact
NA2XY 0,6/1 kV 3-1x185 mm2 Local Sales
ventas.peru@nexans.com

CHARACTERISTICS
Construction characteristics
Conductor material Aluminum Alloy 1350
Insulating material XLPE
Individual sheath PVC
Lead free Yes
Sheath colour Individual sheath White-Black-Red
Dimensional characteristics
Number of cores 3
Conductor cross-section 185 mm²
Total number of wires 37
Conductor diameter 15.8 mm
Minimum insulation thickness 1.6 mm
Minimum outer sheath thickness 1.2 mm
Height 21.8 mm
Width 65.1 mm
Approximate weight 2066 kg/km
Electrical characteristics
Rated Voltage Uo/U (Um) 0.6/ 1 (1.2) kV
Dielectric strength 3.5 kV
Time of application Dielectric strength core to screen AC - min.
Max. DC resistance of the conductor at 20°C 0.164 Ohm/km
Nominal capacitance 713.0 pF/m
Permissible current rating when buried 309 A
Mechanical characteristics
Cable flexibility Class 2 IEC 60228
Usage characteristics
U.V resistance UL 2556 - Sunlight Resistance
Flame retardant IEC 60332-1-2; FT1
Oil resistance ICEA S-95-658
Maximum operating temperature 90 °C
Overload maximum core temperature 130 °C
Short-circuit max. conductor temperature 250 °C

Lead free Rated Voltage Uo/U Cable flexibility U.V resistance Flame retardant Oil resistance Maximum operating
Yes (Um) Class 2 IEC 60228 UL 2556 - Sunlight IEC 60332-1-2; FT1 ICEA S-95-658 temperature
0.6/ 1 (1.2) kV Resistance 90 °C

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is
indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Generated 11/6/21 www.nexans.pe Page 3 / 4
NA2XY 0,6/1 kV; Double or Triple; DNC-ET-094a Contact
NA2XY 0,6/1 kV 3-1x185 mm2 Local Sales
ventas.peru@nexans.com

BENDING RADIUS WHEN INSTALLED IN L.V.

R=Dxf
R: Bending radius when installed (mm)

D: Diameter over sheath or over insulation (when it has not sheath) (mm)

f: Multiplicative factor; given the following table:

BENDING RADIUS FACTOR LV

CALCULATION OF CURRENT CONDITION L.V.; 90°C - LUZ DEL SUR

CALCULATION OF CURRENT CONDITION

Installation : Direct burried - horizontal in contact.


Maximum conductor temperature : 90°C.
Ground temperature : 25°C.
Depth of laying : 0,6 m.
Thermal resistivity of soil : 1,5 K.m/W.

Lead free Rated Voltage Uo/U Cable flexibility U.V resistance Flame retardant Oil resistance Maximum operating
Yes (Um) Class 2 IEC 60228 UL 2556 - Sunlight IEC 60332-1-2; FT1 ICEA S-95-658 temperature
0.6/ 1 (1.2) kV Resistance 90 °C

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is
indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Generated 11/6/21 www.nexans.pe Page 4 / 4