TROUBLESHOOTING MON-12

Related electrical circuit diagram

20-964 HD465-7, HD605-7


(5)
TROUBLESHOOTING MON-12

f) Air is not cooled (Mechanical system)

Action code Failure code Controller code Defective air conditioner


Trouble
Not set Not set Not set f) Air is not cooled (Mechanical system)
Contents of trouble • Air is not cooled because of abnormality in mechanical system.
Action of controller • None in particular.
Problem that
• Air is not cooled because of abnormality in mechanical system.
appears on machine
Related information

Cause Standard value in normal state/Remarks on troubleshooting


Gas leakage through pipe
1 • Check and repair or replace, if abnormal.
joints or parts
Natural leakage through
hose, etc. (Refrigerant has • Check refrigerant level and add new refrigerant to proper level, if nec
2
not been added for long essary.
time)
3 Insufficient refrigerant level • Add new refrigerant to proper level.
• Check and repair or replace, if abnormal.
4 Defective expansion valve a Check the valve for excessive opening and defective contact of
heat-sensor tube, too.
Clogging of low-pressure
5 • Check and remove clogging material, if there is any, or replace.
circuit and evaporator
• Check and remove clogging material, if there is any, and clean evap-
Possible causes 6 Clogging of evaporator fins
orator.
and standard value
in normal state 7 Clogging of filter • Check and clean, or replace.
Defective installation of ther-
8 • Check and repair or replace, if abnormal.
mistor
Air leakage through air con-
9 • Check and repair or replace leaking part.
ditioner unit and duct
10 Insufficient set air flow • Increase set air flow.
11 Excessive refrigerant • Check refrigerant level and reduce it to proper level, if necessary.
• Evacuate system and fill it with refrigerant to proper level and replace
12 Entry of air
receiver drier.
13 Clogging of condenser fins • Check fins for clogging and clean them, if necessary.
Insufficient compression by
14 • Check and repair or replace, if necessary.
compressor
Entry of water in refrigerant • Evacuate system and fill it with refrigerant to proper level and replace
15
circuit receiver drier.

HD465-7, HD605-7 20-965


(10)
TROUBLESHOOTING MON-12

g) Air is not heated (Defective hot water circuit)

Action code Failure code Controller code Defective air conditioner


Trouble
Not set Not set Not set g) Air is not heated (Defective hot water circuit)
Contents of trouble • Air is not heated (Defective hot water circuit).
Action of controller • None in particular.
Problem that
• Air is not heated (Defective hot water circuit).
appears on machine
• Check that water is not leaking through the hot water circuit.
Related information
• Check that air is flowing out of the air outlets.

Cause Standard value in normal state/Remarks on troubleshooting


• Check heater core fins for clogging and clean them, if necessary.
1 Clogging of heater core fins a If this is the cause, the temperature at the hot water inlet and outlet
of the heater core becomes high.
• Check and repair or replace leaking part.
Air leakage through air con-
2 a If this is the cause, the temperature at the hot water inlet and outlet
ditioner unit
of the heater core becomes high.
Possible causes • Check and remove clogging material, or replace valve.
and standard value 3 Defective water valve a If this is the cause, the temperature at the hot water inlet of the heat-
in normal state (Clogging or defective valve)
er core becomes high but that at the hot water outlet becomes low.
• Check and repair or replace leaking part.
a If this is the cause, the temperature at the hot water inlet of the heat-
4 Clogging of heater core
er core becomes high but that at the hot water outlet becomes low.

• Check and repair or replace leaking part.


Clogging up to hot water
5 a If this is the cause, the temperature at the hot water inlet of the heat-
inlet of heater core
er core becomes low.

h) Abnormal sound comes out

Action code Failure code Controller code Defective air conditioner


Trouble
Not set Not set Not set h) Abnormal sound comes out
Contents of trouble • Abnormal sound comes out.
Action of controller • None in particular.
Problem that
• Abnormal sound comes out.
appears on machine
Related information

Cause Standard value in normal state/Remarks on troubleshooting


Defective installation of bolts
1 • Check and repair, if abnormal.
(screws) related to case
Interference of fan case, etc.
2 • Check and repair or replace, if abnormal.
or breakage of fan
Entry of foreign matter in
Possible causes 3 blower motor or defective • Check and remove foreign matter, if there is any, and repair or replace
and standard value blower motor
in normal state • Check and replace, if abnormal sound (peep or gas leakage sound)
4 Defective expansion valve
comes out.
Loosened or worn
5 • Check and repair or replace, if loosened or worn.
compressor V-belt
Insufficient or excessive • Check refrigerant level and reduce or increase it to proper level, if
6
refrigerant necessary.
7 Defective compressor • Check and repair or replace, if abnormal.

20-966 HD465-7, HD605-7


(10)
TROUBLESHOOTING MON-12

i) Water leaks

Action code Failure code Controller code Defective air conditioner


Trouble
Not set Not set Not set i) Water leaks
Contents of trouble • Water leaks.
Action of controller • None in particular.
Problem that
• Water leaks.
appears on machine
Related information

Cause Standard value in normal state/Remarks on troubleshooting


Clogging of water drain hole
1 • Check and repair, if abnormal.
in air conditioner unit
Clogging, bend, defective
installation, or breakage of
2 • Check and repair or replace, if abnormal.
drain hose of air conditioner
unit
Possible causes Breakage (Cracking) of air
and standard value 3 conditioner unit case • Check and repair or replace, if broken (cracked).
in normal state
Defective installation of bolts
4 (screws) related to air • Check and repair or replace, if abnormal.
conditioner unit case
Defective joints of hot water
5 • Check and repair or replace, if abnormal.
circuit piping
6 Defective heater core • Check and repair or replace, if abnormal.
7 Defective water valve • Check and repair or replace, if abnormal.