General description AAA, Fg re 1 Typieal type SDV7-AR cletrbution cuit breaker Introduction Siemens type SDV7-AR distribution circuit breaker is precision built equipment designed to function efficiently under normal operating conditions. itis designed and manufactured to operate within the parameters established in ANSUIEEE C37 and NEMA standards for distribution circuit breakers. Performance requirements of these standards have been rmet or exceeded by these designs. Specific standards which apply include: = ANSIIEEE C37.04-1999 rating structure for ac high voltage circuit breakers = ANSIIEEE C37.06-2009 preferred ratings ac high-voltage circuit breakers = ANSIIIEEE €37.09-1999 test procedure for ac high-voltage circuit breakers = ANSIIEEE C37.20-7-2007 guide for testing metal-enclosed switchgear rated up to 3B KV for internal arcing faults = NEMA 'SG4-2009 ac high-voltage circuit, breakers. ‘The instructions included in this instruction ‘manual are provided to aid you in obtaining longer and more economical service from your Siemens type SDV7-AR distribution circuit breaker. For proper installation and ‘operation, this information should be distributed to your operators and engineers. By carefully following these instructions, difficulties should be avoided. However, these instructions are not intended to cover all details of variations that may be encountered inconnection with the installation, operation and maintenance of this equipment. Should additional information be desired, including replacement instruction manuals, contact your local Siemens representative. ‘To provide additional personal protection in the event of an internal arcing fault, tis, equipment is also classified as arc resistant switchgear and has been qualified to carry a type 28 accessibility rating per ANSIIEEE ©37.20.7. Scope These instructions cover the instalation, ‘operation and maintenance of a Siemens type SOV7-AR distribution circuit breaker using vacuum interrupters. The equipment designs described in this instruction manual consists of free standing outdoor distribution circuit breakers for application up to 38 KV. Atypical type SDV7-AR distribution circuit breaker is shown in Figure 1: Typical type SDV7-AR distribution circuit breaker. All diagrams, descriptions and instructions apply to all of the above classes and designs unless noted otherwise, Standard construction details of the circuit breaker enclosure are given in appropriate sections of this instruction manual. Standard construction details of the stored- energy operating mechanism of the circuit breaker are detailed in the type 3AH35-SE stored-energy operator instruction manual [E50001-F7 10°K376-XXXXX, Standard construction details of the magnetic actuator operating mechanism of the circuit breaker are detailed in the type 3AH35-MA magnetic-actuator operator instruction manual £50001-F710-378-X 200K Special mechanical and electrical devices, furnished in accordance with purchase order Fequirements, are covered by supplementary instructions submitted with ths instruction manval. The equipment furnished has been designed to operate in a system having the circuit capacity specified by the purchaser. If for any reason the equipment is used in a different system or ifthe short-circuit capacity of the system is increased, the ratings of the equipment, including the momentary rating and the interrupting capacity ofthe type SSDV7-AR distribution circuit breaker must be ‘checked, Failure on the part of the user to receive approval of intended changes from Siemens may cause the warranty to be void. This instruction manual applies to the type SSDV7-AR distribution circut breaker enclosure structure, Refer to instruction manual 50901-F710- K376-X-XXXX for instructions applicable to the type3AH35-SE stored-energy operator. Refer to instruction manual £50001-F710 K378X-XXXX for instructions applicable to the type 3AH35-MA magnetic actuator operator. General description The distribution circuit breaker described in this instruction manual is of the ac high voltage outdoor circuit breaker type, as defined in ANSIIEFE C37 and NEMA SG4 standards. All high-voltage parts excluding roof bushings are completely enclosed within {grounded barriers. The secondary control devices and primary circuits are isolated from ‘each other by barriers, Siemens type SOV7-AR distribution circuit breakers carty a type designation, as shown in Table 1: Type SOV7-A& distribution circuit breaker designations. This designation may ‘appear on drawings and familiarity with them will simplify communications with the factory, In this instruction manual, reference to type ‘SDV7-AR distribution circuit breaker is used Sioa when the text applies to the circuit breaker Storedenergy | SDV7-SE-AR With either type of operating mechanism, Magretic When relevant to the type of operator, the Tewator | SOVTMAAR type SDV7-SE-AR (stored-energy) oF type SSDV7-MA-AR (magnetic-actuator) able 1: Type SOV7 ais designations are used. aker designations Additionally, this equipment is classified as, are-resistant, as defined in ANSUIEEE €37.20.7, and has been qualified to carry a type 28 accessibility rating. The arcvesistant features are intended to provide an additional degree of protection to personnel in close proximity to the equipment in the event of an internal arcing fault while the equipment is ‘operating under normal conditions. Normal conditions include the “usual service conditions" defined in ANSUIEEE C37.04, clause 4 and ANSWIEEE C37.010, clause 4, as well as the following conditions intended to maintain the integrity of the equipment during an internal arcing fault event: 1. Alldoors and panels providing access to primaty compartments must be closed and properly secuted (All bolts installed and tightened. All latches in latched position.) 2. All pressure relief devices must be free to operate as designed, 3. The fault energy available to the equipment must not exceed the internal arcing short-circuit current rating and rated arcing duration of the equipment. 4, There must be no obstructions around the equipment that could direct the arcing exhaust products into an area intended to be protected. 5. The equipment must be properly grounded, 6. Allequipment must be properly installed in accordance with information in instruction manuals and drawings. 7. The type SOV7-AR enclosure must be installed with the arc-exhaust vents at least 79" (2.0m) above finished grade. Figure 3: Outine crowing! Note 1: Shown with optional High-yotage ross racing for compaitment high seismic loading, ané wth lege installs at a maximum Ly ° height 28" operator Relay and 1 me) compartment contral == . svouns note: compartment pac on mtb q q tiger isa th | CH canon sensation | ap Efe ; ream | thor nthe ge Dimensions in inenes (ar) Note + a EC a EE Cy eT a ET Ty Ext Aa essa ON Eo PRs sada} cay pr 30° A | a7. (96) |563(1430] s63c430) | 6570.86) | Me | 3" 30° 30 2 [sas | niaen | zicen | ace [w | sae [azo |woaie | sean < [aces [reomne | 160m | test [0 | 7609) | 77080 | 76099 [ss cen >| 2060 | 206n | 206n | 20@ |p | vascr) | sesGr | 36409 | ee10a7m = | 80a) | soos | soae) | som) |e] 300 | 3070 | 3000 | 3000 + [area [71 2.009] Toa acon [oon as | « | 313099 [a4 0.000 [seacrcon | os 029m © [-a27 0.085) [s2oris2H | sao | eBrc.e05) | s | 388995) | a7.0C1.156) | sow cnTe9) | SEACH soc} aoc | oqo | accra w [asc [sracsem| aec2e [azo | 1 | £209 | s9gen | secon | soca, T | soos | teeceen | 115092) | soars | uv | 73501867 | 77200960 | 77eC17D | 93.5 (2.375) 92.0 (2,387) | 96.0 (2,337). | 96.0.2,337). | 1205 (3,061) 116.0 (2.945) | 120.0(,048) | 120.0(3.048) | 144.5 (3,570) 1 | 198003) | 2.0¢07 | 2.0G0n | 2220566 | v x | s0@oy | eae | 115092 | 20461) 30° 30° 30° 30" w | s3.9(0,623) | e5.5 crea | 65.500,664) | 90.2(2.037) 2

You might also like