Installation
&
Operation Manual
Contents
I. SYSTEM INTRODUCTION........................................................................................................................................................3
V. EQUIPMENT PICTURE..........................................................................................................................................................5
X. SYSTEM DEBUGGING.........................................................................................................................................................19
V. Equipment Picture
5.1 This picture shows JT-2000C-8 master controller and its icon descriptions are as follows:
1---Visitor linkage, password keyboard and fingerprint interfaces 7---Output interfaces of floor 1~8
2-- Fire fighting, manual and VIP functions detection inputs 8----485 remote monitoring and VIP output interfaces 3---
Output indicators of floor 1~8 9---antenna interface
4---Battery (clock) 10---Voice interface
5---Power interface 11--- SW2Dial switch for switching over working state
5.3 JT-01FA IC card reader (card reader + antenna for card reading)
Overall dimension 138×110×12mm
Installation position It is used for built-in installation and it is installed in operation panel or car wall. It is used in post
installation.
5.4 JT-01FB IC card reader (card reader + antenna for card reading)
Overall dimension 100×83×15mm
Installation position It is used for built-in installation and it is installed in operation panel or car wall. It is used in
pre-drilled hole installation.
5.5 JT-01I IC card reader (card reader + antenna for card reading)
Overall dimension 104×80×32mm
Installation position It is used for built-in installation, it is installed in operation panel or car wall and It is used in pre-
drilled hole installation.
JT-2000C-16
Serial Code Name Remarks
No.
1 J1-J16 Key output interfaces of 16 floors Connect corresponding floor keys of the elevator, the key of the ground
floor corresponds to J1 and the key of the top floor corresponds to J16
1: GND
3: TB
4: TA
6: GND
8: +5V
9: +24V
6.1.3.1 JT-01H IC Password Keyboard, which is not accompanying with this system
6.1.3.2 After fingerprint (JT-01D) is connected, the fingerprint hierarchical control function can be realized, and the
installation effect picture is shown as follows:
6.1.4 The figure shows fire fighting & manual switch and VIP detection interfaces
The card-reading antenna is connected through coaxial cables to realize the data exchange between card and master
controller.
6.1.6 Voice
Voice prompt only prompts voice in the form of fixed serial number at fixed position under fixed conditions, these voices
can not be altered at random, in case voice alteration is required, only the voice content of corresponding voice number
6.1.11 J1—J8
J1—J8 are 8-bit output ports, the output of each bit adopts optocoupler output form, in case of no output, the
corresponding indicator will not be lit, only when the corresponding indicator is lit, there is output. Because
optocoupler output is adopted, its output port falls into positive and negative polarity, only when the polarity of
external circuit is correct, correct control purpose can be achieved, in case of reversed polarity, it forms a closed
circuit with external circuit under any circumstances, for details of its connection with button port of elevator, please
refer to schematic diagram.
VIII.Installation Instructions
The installation of IC card control system mainly includes installation of master control panel, installation of card reader
and electrical connection of controller and elevator. In case the system possesses visitor function, then its installation also
includes the installation of linkage components.
9.1 Installation of Master Control Panel:
According to actual conditions on site of most elevators, the master control panel is generally installed in the
operation panel directly. It just needs to be fixed at the appropriate position in the bottom case of operation panel.
After installation, the circuit board shall be isolated from metal parts, and when screws are adopted for fixing it,
insulation measures shall be taken at the bottom of the circuit board to insulate it from metal parts. In case of no space
in the case, control parts can be fixed on the car roof directly after being covered with an external packaging box.
9.2 Installation of Card-reading Antenna
Its installation position shall be determined according to actual conditions on site, when there is enough space to
install card reader in the operation panel of elevator, it is preferred to install the card reader on the panel board of
operation panel, in case of no position, the card reader can be installed on the car side wall and the distance between it
and the car ground is about 1.2 meters generally.
For metal panel board of operation panel, the user shall drill hole on the panel board of elevator operation panel
according to hole-opening dimension provided in the manual, for specific dimensions and position, please refer to
“Dimension Drawing of Pre-drilled Hole for Card Reader” or “Dimension Drawing of Post Installation for Card
Reader”, and for installation method, please refer to “Installation Schematic Diagram of Card Reader”.
Operation Board
Car Wall
Rear fixing
splint of card Card reader
reader
Stainless steel
panel
Securing nut
Card-reading
zone
Rear cover of
card reader box
Interface of
communication Welded screw at
line the back 2-
M3*20
Securing nut
Card-reading
zone
splint of card
reader
Fixing panel of
than 105mm
card reader
plane (stainless
Rear cover of More than 85mm and
steel ) less than 90mm
card reader box
Interface of
communication
line
Effect Picture
after Installation
After the installation of the system is completed, the system shall be adjusted all sidedly so as to meet specified
requirements.
9.1 Energizing test: At first, confirm whether there is voltage in the power supply and measure it with a multimeter. The
voltage range shall be DC12V~DC36V. Insert the power plug into the internal control panel, and then the power
indicator shall be lit, in case it is not lit, the polarity of power supply may be reversed, so you just need to adjust
both the power cords, or disconnect RS232 communication line and then plug with power, in case it is still not
energized in the test, please replace the master control panel. In case the master panel can be energized but it can not
be energized after the card reader is connected, replace the card reader or RS232 communication line for test.
9.2 After the system is energized normally, card-reading test shall be conducted: Card reading shall be conducted after
the system enters into normal running, when the system is energized and the buzzer does not give a long buzz any
longer, the system runs normally.
9.3.1 Key card test: After the card is swiped, the buzzer gives a buzz, the system enters into IC management unlocking
state and all the light-emitting diode indicators at output ports are lit, in case they are not lit, replace the control
panel, after the card is swiped again, the buzzer gives two buzzes, it shows that the system is at running state and
the user needs to take the elevator by swiping card.
9.3.2 Chargeable card test: In the card making process, the number of card-swiping times shall be controlled between 10
~20 times, when the SW1 is slide to ON state, the system work is at charging state.
In case the buzzer gives a buzz when the card is swiped, it shows that the remaining number of card-swiping
times in the card is above 10 times, in case the buzzer gives two buzzes, it shows that the remaining number of
card-swiping times in the card is less than 10 times, and in case the buzzer gives three buzzes, it shows that there
is no money in the card and the user shall recharge it. When the buzzer gives three buzzes, in case the bit code 4
of dial switch SW2 is slide to OFF state and the card is swiped again, the system shall output information. In case
there is no response after card swiping but the key card is valid, in the event that the card is made correctly, adjust
the elevator No. and retry after the elevator No. is correctly adjusted. When the elevator No. is correct but the card
can not be swiped successfully, then the elevator No. must be set incorrectly during the card making process and a
new card shall be made.
9.3.3 Time period card test: Before the time period card is used, the clock of master controller shall be adjusted firstly.
Make a clock card of current time and swipe it for one time in the elevator. The clock card can only be used once,
in case of several elevators, then several clock cards shall be made to adjust the clock, what’s more, the time
period card can only be valid in specified time range. The elevator No. set in the card shall to be in conformity
with the elevator No. of controller. When other cards can be used and only time period card can not be used,
please adjust the clock of controller or check the time period setting of the card, in case it still can not be used
normally, replace the master controller and then reset the elevator No. and clock.
9.3.4 all pass card test: this card is used for manager of the building who can go to any floor. After swiping card, he must
press the button to select floor.
9.4 Output test: 1. Test of swiping card, pressing key and selecting floor: From J2, the output ports shall be in one-one
correspondence with the sequence of elevator car call keys, there can be vacancy between them, which provides
convenience for setting during card making process. In the debugging, generally, use the key card to set the system
to IC card state and set the elevator to attendant operation state firstly, after pressing the internal selecting key of
the elevator, all the car calls can not be registered, in case of car call which can be registered, please exchange the
positions of output lines at the corresponding output ports 1 and 2 of car call on the floor, connect them properly
1. Elevator No.: The elevator No., which is combined with the software card-making system of host computer, is a noun
set to disable users with cards to enter other units (elevators). The user with card can only use the elevator with the
corresponding elevator No. but can not use elevators with different elevator No. The maximum elevator No. is 255. In
case you wan to view the elevator No., you can power the system up again firstly, observe which indicator is lit
among output indicators LED1~LED8 after waiting about 30 seconds, and then you can calculate the elevator No. of
corresponding master panel according to 8421 encoding mode.
2. Office No.: The office No., which is combined with the remote control system, is an address. In case the system has
remote control function, then the office No. is unique and can not be repeated. The maximum office No. is 255. In