Standard technical specifications GIA SwedVent high pressure tunnelling fans with accessories

FAN MODEL AVH63 AVH71 AVH90 AVH100 AVH112 AVH125 AVH140 AVH160 AVH180 AVH224

Motor F-class, IP54, 400/440 V, 50/60 Hz


Nominal 132-500
9-25 kW 11-37 kW 37-90 kW 45-110 kW 9-37 kW 45-160 kW 45-160 kW 75-315 kW 132-500 kW
power kW
Impeller 1000/1200
3000/3600 rpm 1500/1780 rpm
speed rpm
Bearings SKF
Bearing lubri-
SKF "auto-lubricators system 24" on casing outside
cation
Ø1000
Ø380 mm, Ø380 mm, Ø560 mm, Ø560 mm, Ø560 mm, Ø800 mm, Ø800 mm, Ø800 mm,
mm, Ø1000 mm,
Impeller hub cast welded welded welded cast cast welded welded
welded welded steel
aluminium steel steel steel aluminium aluminium steel steel
steel

Impeller 10 pcs, cast aluminium, adjustable at


8 pcs, cast aluminium, adjustable at stillstand
blades stillstand

Gap between
FANS

blade top and 1,5 mm 1,5 mm 1,5 mm 1,5 mm 2,0 mm 2,5 mm 2,5 mm 3,0 mm 3,0 mm 3,0 mm
fan casing

Casing inner
630 mm 710 mm 900 mm 1000 mm 1120 mm 1250 mm 1400 mm 1600 mm 1800 mm 2240 mm
Ø

Fan casing
5 mm 5 mm 6 mm 6 mm 6 mm 6 mm 8 mm 8 mm 8 mm 10 mm
thickness
Casing anti-
rust 60 μ acryl primer + 100 μ acryl top layer
protection
laser-cut,
Casing
8x50 mm, laser-cut, 10x60 mm, welded laser-cut, 10x70 mm, welded
flanges
welded

Turbu-lence
Guide vanes welded to inside casing + 5 straight longitudinal "fins"
elimi-nation

CE-marking yes

Perform-ance
full test before delivery, capacity measure-ments
test
Allowed
< 2mm/s
vibrations

MODEL GS63 GS71 GS90 GS100 GS112 GS125 GS140 GS160 GS180 GS224

Inner Ø 630 mm 710 mm 900 mm 1000 mm 1120 mm 1250 mm 1400 mm 1600 mm 1800 mm 2240 mm

Outer Ø 790 mm 870 mm 1060 mm 1160 mm 1280 mm 1410 mm 1560 mm 1760 mm 1960 mm 2400 mm

Length 1000 mm 1000 mm 1200 mm 1200 mm 1200 mm 2000 mm 2000 mm 2400 mm 2400 mm 3000 mm
Casing
laser-cut, 8x70 mm, welded laser-cut, 8x80 mm, welded
flanges
Casing
3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 4 mm 4 mm 4 mm 5 mm
thickness
SILENCERS

Sound
absorbing Heavy mineral wool
material

Self support-
ing to fan yes
casing

Casing anti-
rust 60 μ acryl primer + 100 μ acryl top layer
protection
centre
"Super centre baffle, l=800 centre baffle, l=1000 mm, Ø550 centre baffle, l=1800 centre baffle, l=2200 baffle,
silencer" mm, Ø380 mm mm mm, Ø640 mm mm, Ø640 mm l=2500 mm,
Ø640 mm
MODEL GIB63 GIB71 GIB90 GIB100 GIB112 GIB125 GIB140 GIB160 GIB180 GIB224
INLET BELLS
Intake "Bell shaped", pressure turned

Casing
2 mm 3 mm
thickness

Protect-ion
grille "spider
net model"
DUCT ADAPTERS

MODEL GDA63 GDA71 GDA90 GDA100 GDA112 GDA125 GDA140 GDA160 GDA180 GDA224

Length 150 mm 150 mm 150 mm 150 mm 150 mm 150 mm 200 mm 200 mm 200 mm 200 mm
Casing
3 mm 4 mm
thickness

Ø9 mm ring welded to adapter end for securing ducting

Nominal
11-500 kW
power
FREQUENCY INVERTERS

Electrical
400/440 V, 50/60 Hz
supply
Adjust-able
250 rpm up to full speed
fan speed

Protec-tions motor current, short circuit, phase failure, over- and under voltage

Operating
LED-display with control buttons mounted on outside casing door
controls

Cooling By cooling fan


Capsuling IP 21
Standard
extra All circuit boards laquered for protection against moisture and dust
protection
CE-marking yes
Others The inverters fulfil the EU-regulations for start of electrical equipment
Optional Inverters built in in an IP54 cabinet. Circuit breaker, automatic fuses, cabinet heater are also optional.
Optional EMC-filter
Nominal
11-132 kW
power
DAHLANDER STARTERS Electrical
400/440 V, 50/60 Hz
supply
Possible fan
Two-speed (half/full)
speed

Protec-tions motor current, short circuit

Operating
Control buttons mounted on outside casing door
controls
Capsuling IP 54 cabinet
CE-marking yes
Others The starters fulfil the EU-regulations for start of electrical equipment
Optional Circuit breaker, automatic fuses, cabinet heater
Optional Cabinet heater

Nominal
11-132 kW
power
Electrical
DIRECT STARTER

400/440 V, 50/60 Hz
supply
Possible fan
One-speed
speed

Protec-tions motor current, short circuit

Operating
Control buttons mounted on outside casing door
controls
Capsuling IP 54 cabinet
CE-marking yes
Others The starters fulfil the EU-regulations for start of electrical equipment
Optional Cabinet heater