2.Summary of Change
New, Add,
Applicable
Group Name/Outline Correct,
Date
Delete
Basic
Optional
Function
Unit
Maintenance
Parts
Notice
Correction The description of parameter No.1850 (Grid shift for each axis) is corrected.
Another
The data setting range of parameter No.1850 (Grid shift for each axis) is corrected.
Detail
The data setting range of parameter No.1850 (Grid shift for each axis) is corrected as follows.
Before correction )
[Valid data range] 0 to 99999999 (for reference position shiht)
Reference counter size or less (for grid shift)
To shift the reference position, the grid can be shifted by the amount set in
this parameter.
Up to the maximum value counted by the reference counter can be specified
as the grid shift.
In case of parameter SFD (No.1002#2) is 0: Grid shift
In case of parameter SFD (No.1002#2) is 1: Reference position shift
After correction )
[Valid data range] 0 to 99999999 (for reference position shiht)
( - Reference counter value ) to ( + Reference counter value ) (for grid shift)
To shift the reference position, the grid shift value or reference position shift
value is set in this parameter for each axis.
Up to the maximum value counted by the reference counter can be specified
as the grid shift.
In case of parameter SFD (No.1002#2) is 0: Grid shift
In case of parameter SFD (No.1002#2) is 1: Reference position shift