Quality

Check list

Eqc type (Civil - Gypsum Ceiling) UOM: SQ.FT ISO:

Stage (Pr e Execution) Witness: ✔ Drawing: ✔

1 Is methodology for work approved?

Options Yes : (P) No : (F)

Are all false ceiling drawings co-ordination with MEPFLV service


2
drawings?

Options Yes : (P) No : (F)

3 Are materials used for False ceiling are as per the specifications?

Options Yes : (P) No : (F)

4 Are the required service work s above the false ceiling complete? ( )

Options Yes : (P) No : (F)

Are level mark ed for false ceiling mark ed and check ed by


5
authorized person?

Options Yes : (P) No : (F)

Stage (Dur ing Execution) Witness: ✔ Drawing: ✔

Is the level and alignment of false ceiling maintained as mention in


1
drawings?

Options Yes : (P) No : (F)

Is fixing of channel and suspender as per requirement and


2
sufficient?

Options Yes : (P) No : (F)

3 Is filling of joint done with approved material?

Options Yes : (P) No : (F)

Are Provision made for Electrical and HVAC services given as per
4
drawings? ( )

Options Yes : (P) No : (F)

Are additional support given where cutout for MEPFLV work to be


5
given?

Options Yes : (P) No : (F)

1/2
Stage (Post Execution) Witness: ✔ Drawing: ✔

Are the levels and alignment check ed for gypsum ceiling after
1
completion of work ?

Options Yes : (P) No : (F)

2 Is all work completed with proper filling at joint?

Options Yes : (P) No : (F)

Notes:
1. EQC (Element of Quality Control)
2. P indicates pass
3. F indicates fail
4. is mandatory photograph for point
5. is mandatory remark for point
6. ✔ required
7. ✘ not required

2/2