Design Improvements
• The SSG Air Cleaner has filters
that use RadialSeal™ Sealing
Technology, compared to
axial seal style filters. This
single design improvement The large, massive mining vehicle in the picture above is an ideal match for the
eliminates the need to replace Donaldson SSG Air Cleaner.
filter and cover gaskets - less
service time and fewer parts to
inventory.
104 n
Engine Air Cleaners, Accessories & Service Parts
SSG Donaclone™ Air Cleaner
Applications
SSG Specifications
Heavy Dust Conditions
Front View Dual Outlet Front View Single Outlet Side View Dual and Single
J J F D
C A
OUTLET
INLET INLET I
INLET INLET
H H
106 n
Engine Air Cleaners, Accessories & Service Parts
SSG Donaclone™ Air Cleaner
G200086, G200087
NOTES:
3 = Shipped with air cleaner initially
G290055
two, short strips P603504
two, long strips P115096 Donaclone
pre-cleaning
tubes
Air Inlet
Perforations on
three sides of Service cover
the lower body with safety chain
(approx. 10")
cover P603716
cover chain P017281
chain connector P017283
108 n
Engine Air Cleaners, Accessories & Service Parts
SSG Donaclone™ Air Cleaner
25
20 30
Restriction (mbar)
20
Restriction (mbar)
Restriction (mbar)
15 25
15
10 20
10
5 5 15
0 0 10
46 50 54 58 62 40 44 48 52 56 60 66 72 76 84
Air Flow (m³/min) Air Flow (m³/min)
Air Flow (m³/min)
Restr. A/c Piezo
25 25 25
Restriction (mbar)
Restriction (mbar)
Restriction (mbar)
20 20 20
15 15 15
10 10 10
5 5 5
80 90 100 110 120 84 95 106 117 128 110 120 130 140 150
Air Flow (m³/min) Air Flow (m³/min) Air Flow (m³/min)
25
20
Restriction (mbar)
15
10
0
55 65 75 85 95
Air Flow (m³/min)
Measure the restriction of the air cleaner with a Inspect the new filter carefully, paying attention to the inside of
Donaldson filter service indicator, service gauge, or the open end, which is the sealing area. NEVER install a damaged
Heavy Dust Conditions
a water manometer via the restriction tap provided filter. A new Donaldson radial seal filter may have a dry lubricant
on the air cleaner or the transfer pipe. Replace the on the seal to aide installation.
filter only when the restriction level has reached the
6
maximum recommended by the engine or equipment
manufacturer.
Insert New Radial Seal Filter Properly
3
The critical sealing area will compress slightly, adjust itself
and distribute the sealing pressure evenly. To complete a tight
Check Tubes for Plugging seal, apply pressure by hand at the outer rim of the filter, not the
flexible center. (Avoid pushing on the center of the end cap.)
When the dust cup is removed, check the tubes. Generally, No cover pressure is required to hold the seal. NEVER use the
Donaclone tubes are self-cleaning and need no service. Under rare service cover to push the filter into place! Using the cover to
circumstances, however, plugging can occur. Visual inspection is push the filter in could cause damage to the housing or cover
adequate. If the tubes carry light fasteners and will void the warranty.
dust, remove it with a stiff brush.
If the service cover contacts the filter before it is fully in place,
Cleaning Note: Never clean remove the cover and push the filter (by hand) further into the air
Donaclone tubes with compressed cleaner and try again. The cover should go on with no extra force.
air unless both the primary and
safety filters are installed in the Once the filter is in place, secure the service cover.
air cleaner. Do not steam-clean
Donaclone tubes.
NEVER use the service cover to
push the filter into place! Using
4
the cover to push the filter in could
cause damage to the housing, cover
Change the Filter Caution fasteners and will void the warranty.
Avoid knocking the filter against the housing during removal. If the
new filter is not to be installed immediately, be sure to cover the seal
tube with a cloth or the housing cover so that dirt is not ingested.
110 n
Engine Air Cleaners, Accessories & Service Parts