Professional Documents
Culture Documents
CKD Ev2500 Catalogue en Cb24sa
CKD Ev2500 Catalogue en Cb24sa
EV2500 Series
Miniature size (1/2 CKD comparison), light weight (1/3 CKD comparison)
High precision air pressure proportional control valve enabling ultimate
space saving of device.
CAD DATA AVAILABLE.
Specifications
Descriptions EV2500 EV2509
Overview Working fluid Clean compressed air (refer to Page 493 for recommended air circuits.)
In this electro pneumatic regulator EV2000 se- Max. working pressure 0.7MPa
ries, feedback control with semiconductor pres- Min. working pressure Control pressure +0.05MPa
sure sensor and electronic control circuit is used. Withstanding (Inlet side) 1.05MPa
Using electric signals, continuous and precise pressure (Output side) 0.75MPa
air pressure control are achieved.
Control pressure range 0 to 0.49MPa
Power voltage DC24V ± 10% (ripple ratio 1 % or less, safety power supply)
Features Current consumption 0.1A or less (rush current 0.6A at power ON)
Input signal 0-10V DC 0-5V DC 4-20mA DC or 1-5V DC 10k varia. resis. or 0-10V DC
• Small / light weight
• Compact modular design (Input impedance) (20k ) (10k ) (250 ) Note 1 (20k )
• Non-bleeding Monitor output 1- 5V DC (none for 10k variable resistance input)
• High relief Hysteresis 1%F.S. or less Note 2
• High precision / high speed response Linearity ± 0.5%F.S. or less Note 2
• Manifold type available
Resolution 0.5%F.S. or less Note 2
• Embedding type option
Repeatability 0.5%F.S. or less Note 2
• Various input signal
• Push in wiring Temperature (Zero point variation) 0.15%F.S./ °C or less
• Pressure monitor available. characteristics (Span variation) 0.07%F.S./ °C or less
• Equivalent to protective structure IP64 Max. flow rate (ANR) 800 /min
• Common exhaust Step response (Loadless) 0.6s or less
Note 3 (1 load) 0.6s or less
JIS symbol
Mechanical vibration proof 98m/S2 or less (JIS C0040 )
IN1 IN2 Ambient temperature 5 to 50 °C
EXH Protection structure Equivalent to IP64 (main body), IP67 (cable connector) Note 4
EXH Port size Rc1/4
IN OUT
Mass (main body ) 300g 320g
OUT Note 1: When used with signal voltage 1-5V DC, 4-20 mA of current flows into inside of EV from the signal
source. Confirm specifications of the signal source before starting use.
Note 2: Above characteristics are values where power voltage is 24V DC, and working pressure range is
0.54 to 0.7MPa. Also, limited to a closed circuit in the secondary side, and the pressure may vary
if used as air blow, etc.
Note 3: Working pressure: Max. working pressure, step rate: 50%F.S. → 100%F.S.
50%F.S. → 60%F.S.
50%F.S. → 40%F.S.
Note 4: Protective stucture IP64 is applied only when installed with facing connector upward.
508
EV2000 Series
How to order
How to order Refrigerating
type dryer
Note 1: Piping adapter can be used for Rc3/8 or larger, but B type / C type bracket can Electronic
not be used. pressure SW
Note 2: Part no. for option is EV2000- option symbol . Electronic
dif. pres.
SW
Seating / close
contact conf.
SW
Pressure SW
for coolant
Flow sensor
for air
Total air
system
Water
cooling
refrigerator
Flow sensor
for water
Electro pneumatic regulator
F.R.L. unit
509
EV2000 Series
Internal structure and parts list
• EV2500 • EV2509
88
88 9
99 77
77
66
66 10
55
10
55
11
11 44
11 44
33
12
12 33
IN1 IN2
IN OUT 22
22 13 11
13 11
OUT
Dimensions
• EV2500 (File name: Page 556 or Ending 19) • EV2509 (File name: Page 556 or Ending 19)
9.5
26 dia.
8 dia.
(Non rotating) 10
M12, 4 pins
Connector / plug M12, 4 pins
Connector / plug Panel cut
adjustment window
11
PUSH OPEN
PUSH OPEN
72
72
32
9.5
3-Rc1/4 4-Rc1/4
26 26 OUT
50 Mount nut 26 26
50
510
EV2000 Series
Monitor output, I/O and flow characteristics
Monitor output Refrigerating
type dryer
• EV2500 / 2509
Desiccant
type dryer
5 High polymer
membrane
dryer
4
Air filter
Monitor output voltage
Automatic
drain
other
3
F.R.L
(Module)
F.R.L
2 (Separate)
(VDC) Small
F.R.
1 Precise
R.
Electro
pneumatic R.
0 0.1 0.2 0.3 0.4 0.5
Control pressure (MPa) Auxiliary
Flow control
valve
• Input signal 0-10V DC • Input signal 0-5V DC • Input signal 4-20mA DC or 1-5V DC • Input signal 10k Ω variable Check valve
/ others
resistance or 0-10V DC
Joint
/ tube
0.5 0.5 0.5 0.5
Vacuum
F.
EV250 * EV250 * EV250 * EV250 *
0.4 0.4 0.4 0.4 Vacuum
R.
Control pressure
Control pressure
Control pressure
Control pressure
Vacuum
generator
0.3 0.3 0.3 0.3
Vacuum
auxiliary
/ pad
Mechanical
0.2 0.2 0.2 0.2 pressure SW
(MPa) (MPa) (MPa) (MPa)
Electronic
pressure SW
0.1 0.1 0.1 0.1 Electronic
dif. pres.
SW
Seating / close
contact conf.
0 0 0 0 SW
2 4 6 8 10 1 2 3 4 5 4 8 12 16 20 2 4 6 8 10
Input signal (VDC) Input signal (VDC) (mADC)
Input signal (K )
1 2 3 4 5
Input signal (VDC) (VDC)
Pressure SW
for coolant
Flow sensor
for air
Flow characteristics Total air
system
• EV2500 • EV2509
Water
Working pressure: 0.7MPa Working pressure: 0.7MPa cooling
refrigerator
Flow sensor
0.5 0.5 for water
Electro pneumatic regulator
F.R.L. unit
0.4 0.4
Control pressure
Control pressure
0.3 0.3
0.2 0.2
(MPa) (MPa)
0.1 0.1
0 0
500 1000 1500 500 1000 1500
Flow rate /min (ANR) Flow rate /min (ANR)
511