Convertible, Dual-Compressor, 61/2 to 121/2-Ton Single Package (60 Hz)

The Predator Package ™

71/2 to 121/2-Ton Single Package (50 Hz)


At York Heating andAir Conditioning,
®

61/2 to 121/2 -Ton Packaged Units (60 Hz)


71/2 to 121/2 -Ton Packaged Units (50 Hz)
Control board Disconnect location Filter access (2" throw-away)
We Provide Comfort
Terminal block for
hi-voltage connection
w/screw connector
for T-stat wiring
(optional disconnect switch)
Filter drier (solid core)
WhereYou Live, Work, and Play
When it’s time to heat or cool Count on York to deliver a wide ®

YORK
Second model Condenser section
nameplate inside
hinged access panel your personal “Landmark,” the range of product choices for
Slide-out motor
and blower assembly YORK name assures you of the residential and light commercial
for easy adjustment
Dual stage cooling
for maximum comfort
and service highest standards of design and applications. Our offering
Belt-drive manufacture. York is the only includes heat pumps, split-

Commercial Package Units


blower motor
Compressor #2 access
(high-efficiency compressor Fortune 500 company focused system air conditioners, gas
Two-stage gas
w/crankcase heater)
heating to maintain solely on heating, ventilation, furnaces, air-handling units,
warm, comfortable
Base rails w/forklift slots
temperatures air conditioning, and refrigeration. and controls — plus chillers
(3 sides) and lifting holes
Power ventor motor
That gives us unique insight into and ventilation equipment for
designing products that meet your larger projects. We’re leading
Roof curbs in 8- and 14-inch 20-gauge aluminized
heights. Roof curbs for steel tubular heat exact requirements. We’re finding the way in developing efficient
transitioning from the exchanger for long life
Slide-out drain
York Sunline™ footprint
pan w/steel 3/4" (stainless steel option) solutions to today’s most critical and environmentally sound
to the DM/DH Series
FPT connection
footprint are also available
Intelligent control concerns — energy efficiency, choices for home and businesses.
(field-installed accessory)
board for safe and
Side entry Compressor #1 access efficient operation refrigerant alternatives, and indoor Let us create the environment
Tool-less door latch Optional convenience power and (high-efficiency compressor
power outlet control wiring w/crankcase heater) air quality — to improve the of success for you.
knockouts
indoor and outdoor environment.

AWide Range of Options Cooling Only


Cooling with
Electric Heat
The YORK Predator line also offers many Sub zero low ambient kit maintains stable cooling
valuable equipment options and accessories: when outdoor temperature is between 0°F and -20°F Cooling with
(field-installed accessory) Gas Heat
-60°F gas heat kit for gas heating in low ambient
temperatures (field-installed accessory) Motorized or manual outdoor air dampers
(field-installed accessories)
BAS option, consult the factory for availability
Phase monitors protect unit from phase imbalance,
Dirty filter switch (factory-installed option) phase drop, and reversed phase rotation (field-installed
Disconnect switch (factory-installed option) accessory; factory-installed standard on units with
Economizer available as a single enthalpy input. scroll compressors)
Exhaust options include barometric relief and Smoke detector (factory-installed option
power exhaust (available as factory-installed option or field-installed accessory)
or field-installed accessory) Stainless steel heat exchanger for all gas heat units
Electric heaters in 9kW to 54kW in voltages with 10-year parts warranty (factory-installed option)
of base units. Carries a five-year parts warranty Technicoat condenser coil coating for corrosion
(field-installed accessory) protection in harsh environments (factory-installed option)
Gas piping kit contains all necessary pipe fittings Thermostat for 24-volt or electro-mechanical
for bottom supply gas piping with external shut-off operation for two-stage heat/two-stage cool
(field-installed accessory) or two-stage cooling only configurations

Note: Not all listed options available on 50 Hz export models. Unitary Products Group
5005 York Drive, Norman, Oklahoma USA 73069
Subject to change without notice. www.york.com 036-11289-001 (800)
© 2000 York International Corporation. All rights reserved. Supersedes Nothing
Convertible Airflow Design
Advanced Design All unit components are covered by a one-year
limited warranty. Compressors and electric heaters
The convertible airflow design of Predator units allows
maximum field flexibility and minimum inventory.
The side duct openings are covered when they leave the
Fan-on and fan-off delays are fully programmable.
Furthermore, heating and cooling fan delay times are
independent of one another. All units are programmed
Predator
Meets Demanding Requirements are covered by five-year warranties. Aluminized steel factory. If a side supply/return is desired, the installer with default values based on cooling and heat configuration.
Contractors searching for value in an advanced
rooftop for light commercial applications will
find it in the YORK® Predator™ line. These
convertible, single package air-conditioning and
heat exchangers are covered by a 10-year warranty;
optional stainless steel heat exchangers are also
covered by a 10-year warranty.
simply removes the two side duct covers from the outside
of the unit and installs them over the down shot openings.
No panel cutting is required.
All indoor fan motors are belt-drive providing maximum
Control board monitors high and low-pressure switches,
freezestats, gas valve (if applicable), and temperature limit
switches on gas and electric heat units.
Alarms include ignition failure, compressor lockouts,
Performance Ratings
gas/electric-heating rooftops offer dual-circuit For flexible configuration, all units are convertible flexibility to handle most airflow requirements. Factory repeated limit switch trips, and fan switch overloads.
for down and side discharge airflow applications. To minimize nuisance service calls, a “three times, you’re * STANDARD EFFICIENCY DM MODELS (60 Hz)
reliability, convenient installation, improved IAQ, installed alternate indoor fan motors are available on
Economizers may be used in either side or down out” philosophy means switches and freezestats must trip Nominal Gas Heat Capacity
competitive performance, hassle-free serviceability, most models for high static applications. With the optional ARI Ratings Sound Unit Curb Approx.
discharge applications. Units can be specified for three times within two hours before the associated Size Electric Heat Seasonal
and flexible configuration. indoor fan motor, all units can supply nominal airflow at a Model CFM Rating Input Output Dimen. Dimen. Operating
cooling only, cooling with electric heat, and cooling compressor will be locked out. Each alarm energizes a (Tons) (dB) Capacity
(MBH) (MBH)
Efficiency (in.) (in.) Wt. (lbs.)
with gas heat. Electric heaters are only available as minimum of 1.5-inch ESP. trouble light on the thermostat (if so equipped) and flashes MBH EER IPLV (kW) (%)
Valuable Features, Greater field-installed accessories. an alarm code on the control board LED. The five most Cooling only — — — — 1041

Easy Installation recent alarms are stored in memory for later review. 078 Electric Heat 9, 18, 24, 34 — — — 1061

Flexibility
77 9.0 9.45 2600 84
(61⁄2) Gas Heat — 120 96 80 1099

Service Friendly and Utility Connection


Non-volatile memory stores programmed values and
alarms if power is lost.
090
Gas Heat
Cooling only
Electric Heat


9, 18, 24, 34
180


144


80


1099
1051
1071
Indoor airflow components are easily reached to Utility connections can be made with minimum field labor. 86 9.0 10.15 3000 84
For dual-circuit reliability, all units have two simplify maintenance and adjustment, thanks to the Gas and electric knockouts are supplied in the unit System Protection (71⁄2) Gas Heat
Gas Heat


120
180
96
144
80
80 503⁄4H
1103
1103
compressors with independent refrigeration circuits. common, slide-out motor and blower assembly and bottom, as well as the side of the unit. A clearly identified Suction line freezestats are supplied on all units to Cooling only — — — — x 501⁄2W 1084
hinged, “tool-less” access panel design. 102 Electric Heat 9, 18, 24, 34 — — — 59W x 1104
For convenient installation, units are easily location is provided to mount a field-supplied electrical protect against the loss of charge and the occurrence of (81⁄2) Gas Heat
98 9.0 9.35 3000 90
— 120 96 80 1173
x 805⁄8D
installed on a roof curb, slab, roof rack, or Access panels have been placed in both condenser disconnect switch. coil frosting. Crankcase heaters and internal compressor Gas Heat — 180 144 80 89D 1173
frame. They are self-contained in a cabinet section walls. Rotation of the cover allows easy All units are shipped with 2-inch throw-away filters installed. protection are standard on all compressors. Every unit Cooling only — — — — 1116
sized to a common footprint, access to the condenser coils for has solid-core liquid line filter-driers and high and low 120 Electric Heat
120 9.0 9.10 4000 90
18, 24, 34, 54 — — — 1136
cleaning or inspection. (10) Gas Heat — 180 144 80 1206
installed on a common-sized roof

Advanced
pressure switches. Gas Heat — 240 192 80 1206
curb, and assembled on a rigid full Unit control board and ignition Cooling only — — — — 1195
perimeter base rail allowing for control board both use flash codes 150 Electric Heat
140 9.0 9.25 4500 90
18, 24, 34, 54 — — — 1215
3-way forklift access and overhead
rigging. Every unit is completely
charged, wired, piped, and tested at
the factory to provide for a quick
and easy installation.
to aid in diagnosing malfunctions.
Unique alarm codes quickly identify
the source of the unit alarm.
Standard, common filter sizes
Controls
While competitive units require added controls and options,
Predator rooftops provide a high level of control by including
Reliability
that Earns the
(121⁄2) Gas Heat
Gas Heat
* See 50 Hz Tech Guide Form 036-21044-001 for pertinent data.


180
240
144
192
80
80
1285
1285

HIGH EFFICIENCY DH MODELS (60 Hz only)


For improved IAQ, foil-faced
eliminate confusion when filters
need replacing.
these features as standard in our SureSense™ control board: Industry’s Best Warranty Nominal Gas Heat Capacity
insulation is used throughout the unit. ARI Ratings Sound Unit Curb Approx.
Integrated low-ambient During assembly, all Predator units undergo computer Size Electric Heat Seasonal
Non-corrosive, slide-out drain pan Model CFM Rating Input Output Dimen. Dimen. Operating
For competitive performance, control allows operation automated testing to confirm refrigerant charge, unit run (Tons)
(dB)
Capacity Efficiency
(in.) (in.) Wt. (lbs.)
permits easy cleaning. The drain pan MBH EER IPLV (kW)
(MBH) (MBH)
(%)
all standard efficiency units have in cooling mode down amperage, and 100% functionality of all components.
can be reversed to facilitate easy Cooling only — — — — 1041
a minimum 9.0 EER; high efficiency to 0°F outdoor ambient
condensate piping. The drain pan On-site durability is ensured by a lifetime-grade powder 078 Electric Heat 9, 18, 24, 34 — — — 1061
units can reach 11.5 EER; gas/ without additional 75 11.5 11.95 2600 84
also features a large slope to ensure paint verified to withstand a 750-hour salt spray test. (61⁄2) Gas Heat — 120 96 80 1099
electric units offer 80% Steady assistance. Optionally, Gas Heat — 180 144 80 1099
proper drainage.
State Efficiencies and employ the control board can All unit components are covered by a one-year Cooling only — — — — 1051
electronic spark ignition and power be programmed to lock limited warranty. Compressors and electric heaters 090 Electric Heat 9, 18, 24, 34 — — — 1071
vented combustion. Balanced Heating out the compressors are covered by five-year warranties. Aluminized steel (71⁄2) Gas Heat
Gas Heat
91 11.5 11.89 3400 84


120
180
96
144
80
80
1103
1103
The Predator offers “Ultimate Heating when the outdoor air heat exchangers are covered by a 10-year warranty; 503⁄4H
For hassle-free serviceability, temperature is low or Cooling only — — — — x 501⁄2W 1084
the motor and blower slide out Comfort” with a balance between optional stainless steel heat exchangers are covered 102 Electric Heat 9, 18, 24, 34 — — — 59W x 1104
first and second stage gas heating. when free cooling is available. (81⁄2) Gas Heat
99 11.5 12.50 3400 84
— 120 96 80 1173
as a common assembly. Speedy by a 10-year warranty. x 805⁄8D
Anti-short-cycle delay aids compressor life and reliability. Gas Heat — 180 144 80 89D 1173
access is provided through hinged, The first stage of a Predator unit provides 60% of the
Cooling only — — — — 1116
“tool-less” panels, which allow quick inspection heating capacity and 40% heating capacity on second Compressor life is also ensured by programmable minimum
120 Electric Heat 18, 24, 34, 54 — — — 1136
of components and areas, including the control stage. Balanced heating allows the unit to better run times. (10) Gas Heat
115 11.0 11.70 3840 90
— 180 144 80 1206
box, compressors, filters, indoor motor and blower, maintain desired temperatures when operating gas heat. Gas Heat — 240 192 80 1206
and the heating section. Cooling only — — — — 1195
Unit Voltage Limitations 150
(121⁄2)
Electric Heat
Gas Heat
146 10.0 10.70 4100 90
18, 24, 34, 54


180

144

80
1215
1285
Power Rating Minimum Maximum Gas Heat — 240 192 80 1285

208/230-3-60 187 253


460-3-60 414 506
575-3-60 518 630
380/415-3-50 342 456
Convertible Airflow Design
Advanced Design All unit components are covered by a one-year
limited warranty. Compressors and electric heaters
The convertible airflow design of Predator units allows
maximum field flexibility and minimum inventory.
The side duct openings are covered when they leave the
Fan-on and fan-off delays are fully programmable.
Furthermore, heating and cooling fan delay times are
independent of one another. All units are programmed
Predator
Meets Demanding Requirements are covered by five-year warranties. Aluminized steel factory. If a side supply/return is desired, the installer with default values based on cooling and heat configuration.
Contractors searching for value in an advanced
rooftop for light commercial applications will
find it in the YORK® Predator™ line. These
convertible, single package air-conditioning and
heat exchangers are covered by a 10-year warranty;
optional stainless steel heat exchangers are also
covered by a 10-year warranty.
simply removes the two side duct covers from the outside
of the unit and installs them over the down shot openings.
No panel cutting is required.
All indoor fan motors are belt-drive providing maximum
Control board monitors high and low-pressure switches,
freezestats, gas valve (if applicable), and temperature limit
switches on gas and electric heat units.
Alarms include ignition failure, compressor lockouts,
Performance Ratings
gas/electric-heating rooftops offer dual-circuit For flexible configuration, all units are convertible flexibility to handle most airflow requirements. Factory repeated limit switch trips, and fan switch overloads.
for down and side discharge airflow applications. To minimize nuisance service calls, a “three times, you’re * STANDARD EFFICIENCY DM MODELS (60 Hz)
reliability, convenient installation, improved IAQ, installed alternate indoor fan motors are available on
Economizers may be used in either side or down out” philosophy means switches and freezestats must trip Nominal Gas Heat Capacity
competitive performance, hassle-free serviceability, most models for high static applications. With the optional ARI Ratings Sound Unit Curb Approx.
discharge applications. Units can be specified for three times within two hours before the associated Size Electric Heat Seasonal
and flexible configuration. indoor fan motor, all units can supply nominal airflow at a Model CFM Rating Input Output Dimen. Dimen. Operating
cooling only, cooling with electric heat, and cooling compressor will be locked out. Each alarm energizes a (Tons) (dB) Capacity
(MBH) (MBH)
Efficiency (in.) (in.) Wt. (lbs.)
with gas heat. Electric heaters are only available as minimum of 1.5-inch ESP. trouble light on the thermostat (if so equipped) and flashes MBH EER IPLV (kW) (%)
Valuable Features, Greater field-installed accessories. an alarm code on the control board LED. The five most Cooling only — — — — 1041

Easy Installation recent alarms are stored in memory for later review. 078 Electric Heat 9, 18, 24, 34 — — — 1061

Flexibility
77 9.0 9.45 2600 84
(61⁄2) Gas Heat — 120 96 80 1099

Service Friendly and Utility Connection


Non-volatile memory stores programmed values and
alarms if power is lost.
090
Gas Heat
Cooling only
Electric Heat


9, 18, 24, 34
180


144


80


1099
1051
1071
Indoor airflow components are easily reached to Utility connections can be made with minimum field labor. 86 9.0 10.15 3000 84
For dual-circuit reliability, all units have two simplify maintenance and adjustment, thanks to the Gas and electric knockouts are supplied in the unit System Protection (71⁄2) Gas Heat
Gas Heat


120
180
96
144
80
80 503⁄4H
1103
1103
compressors with independent refrigeration circuits. common, slide-out motor and blower assembly and bottom, as well as the side of the unit. A clearly identified Suction line freezestats are supplied on all units to Cooling only — — — — x 501⁄2W 1084
hinged, “tool-less” access panel design. 102 Electric Heat 9, 18, 24, 34 — — — 59W x 1104
For convenient installation, units are easily location is provided to mount a field-supplied electrical protect against the loss of charge and the occurrence of (81⁄2) Gas Heat
98 9.0 9.35 3000 90
— 120 96 80 1173
x 805⁄8D
installed on a roof curb, slab, roof rack, or Access panels have been placed in both condenser disconnect switch. coil frosting. Crankcase heaters and internal compressor Gas Heat — 180 144 80 89D 1173
frame. They are self-contained in a cabinet section walls. Rotation of the cover allows easy All units are shipped with 2-inch throw-away filters installed. protection are standard on all compressors. Every unit Cooling only — — — — 1116
sized to a common footprint, access to the condenser coils for has solid-core liquid line filter-driers and high and low 120 Electric Heat
120 9.0 9.10 4000 90
18, 24, 34, 54 — — — 1136
cleaning or inspection. (10) Gas Heat — 180 144 80 1206
installed on a common-sized roof

Advanced
pressure switches. Gas Heat — 240 192 80 1206
curb, and assembled on a rigid full Unit control board and ignition Cooling only — — — — 1195
perimeter base rail allowing for control board both use flash codes 150 Electric Heat
140 9.0 9.25 4500 90
18, 24, 34, 54 — — — 1215
3-way forklift access and overhead
rigging. Every unit is completely
charged, wired, piped, and tested at
the factory to provide for a quick
and easy installation.
to aid in diagnosing malfunctions.
Unique alarm codes quickly identify
the source of the unit alarm.
Standard, common filter sizes
Controls
While competitive units require added controls and options,
Predator rooftops provide a high level of control by including
Reliability
that Earns the
(121⁄2) Gas Heat
Gas Heat
* See 50 Hz Tech Guide Form 036-21044-001 for pertinent data.


180
240
144
192
80
80
1285
1285

HIGH EFFICIENCY DH MODELS (60 Hz only)


For improved IAQ, foil-faced
eliminate confusion when filters
need replacing.
these features as standard in our SureSense™ control board: Industry’s Best Warranty Nominal Gas Heat Capacity
insulation is used throughout the unit. ARI Ratings Sound Unit Curb Approx.
Integrated low-ambient During assembly, all Predator units undergo computer Size Electric Heat Seasonal
Non-corrosive, slide-out drain pan Model CFM Rating Input Output Dimen. Dimen. Operating
For competitive performance, control allows operation automated testing to confirm refrigerant charge, unit run (Tons)
(dB)
Capacity Efficiency
(in.) (in.) Wt. (lbs.)
permits easy cleaning. The drain pan MBH EER IPLV (kW)
(MBH) (MBH)
(%)
all standard efficiency units have in cooling mode down amperage, and 100% functionality of all components.
can be reversed to facilitate easy Cooling only — — — — 1041
a minimum 9.0 EER; high efficiency to 0°F outdoor ambient
condensate piping. The drain pan On-site durability is ensured by a lifetime-grade powder 078 Electric Heat 9, 18, 24, 34 — — — 1061
units can reach 11.5 EER; gas/ without additional 75 11.5 11.95 2600 84
also features a large slope to ensure paint verified to withstand a 750-hour salt spray test. (61⁄2) Gas Heat — 120 96 80 1099
electric units offer 80% Steady assistance. Optionally, Gas Heat — 180 144 80 1099
proper drainage.
State Efficiencies and employ the control board can All unit components are covered by a one-year Cooling only — — — — 1051
electronic spark ignition and power be programmed to lock limited warranty. Compressors and electric heaters 090 Electric Heat 9, 18, 24, 34 — — — 1071
vented combustion. Balanced Heating out the compressors are covered by five-year warranties. Aluminized steel (71⁄2) Gas Heat
Gas Heat
91 11.5 11.89 3400 84


120
180
96
144
80
80
1103
1103
The Predator offers “Ultimate Heating when the outdoor air heat exchangers are covered by a 10-year warranty; 503⁄4H
For hassle-free serviceability, temperature is low or Cooling only — — — — x 501⁄2W 1084
the motor and blower slide out Comfort” with a balance between optional stainless steel heat exchangers are covered 102 Electric Heat 9, 18, 24, 34 — — — 59W x 1104
first and second stage gas heating. when free cooling is available. (81⁄2) Gas Heat
99 11.5 12.50 3400 84
— 120 96 80 1173
as a common assembly. Speedy by a 10-year warranty. x 805⁄8D
Anti-short-cycle delay aids compressor life and reliability. Gas Heat — 180 144 80 89D 1173
access is provided through hinged, The first stage of a Predator unit provides 60% of the
Cooling only — — — — 1116
“tool-less” panels, which allow quick inspection heating capacity and 40% heating capacity on second Compressor life is also ensured by programmable minimum
120 Electric Heat 18, 24, 34, 54 — — — 1136
of components and areas, including the control stage. Balanced heating allows the unit to better run times. (10) Gas Heat
115 11.0 11.70 3840 90
— 180 144 80 1206
box, compressors, filters, indoor motor and blower, maintain desired temperatures when operating gas heat. Gas Heat — 240 192 80 1206
and the heating section. Cooling only — — — — 1195
Unit Voltage Limitations 150
(121⁄2)
Electric Heat
Gas Heat
146 10.0 10.70 4100 90
18, 24, 34, 54


180

144

80
1215
1285
Power Rating Minimum Maximum Gas Heat — 240 192 80 1285

208/230-3-60 187 253


460-3-60 414 506
575-3-60 518 630
380/415-3-50 342 456
Convertible Airflow Design
Advanced Design All unit components are covered by a one-year
limited warranty. Compressors and electric heaters
The convertible airflow design of Predator units allows
maximum field flexibility and minimum inventory.
The side duct openings are covered when they leave the
Fan-on and fan-off delays are fully programmable.
Furthermore, heating and cooling fan delay times are
independent of one another. All units are programmed
Predator
Meets Demanding Requirements are covered by five-year warranties. Aluminized steel factory. If a side supply/return is desired, the installer with default values based on cooling and heat configuration.
Contractors searching for value in an advanced
rooftop for light commercial applications will
find it in the YORK® Predator™ line. These
convertible, single package air-conditioning and
heat exchangers are covered by a 10-year warranty;
optional stainless steel heat exchangers are also
covered by a 10-year warranty.
simply removes the two side duct covers from the outside
of the unit and installs them over the down shot openings.
No panel cutting is required.
All indoor fan motors are belt-drive providing maximum
Control board monitors high and low-pressure switches,
freezestats, gas valve (if applicable), and temperature limit
switches on gas and electric heat units.
Alarms include ignition failure, compressor lockouts,
Performance Ratings
gas/electric-heating rooftops offer dual-circuit For flexible configuration, all units are convertible flexibility to handle most airflow requirements. Factory repeated limit switch trips, and fan switch overloads.
for down and side discharge airflow applications. To minimize nuisance service calls, a “three times, you’re * STANDARD EFFICIENCY DM MODELS (60 Hz)
reliability, convenient installation, improved IAQ, installed alternate indoor fan motors are available on
Economizers may be used in either side or down out” philosophy means switches and freezestats must trip Nominal Gas Heat Capacity
competitive performance, hassle-free serviceability, most models for high static applications. With the optional ARI Ratings Sound Unit Curb Approx.
discharge applications. Units can be specified for three times within two hours before the associated Size Electric Heat Seasonal
and flexible configuration. indoor fan motor, all units can supply nominal airflow at a Model CFM Rating Input Output Dimen. Dimen. Operating
cooling only, cooling with electric heat, and cooling compressor will be locked out. Each alarm energizes a (Tons) (dB) Capacity
(MBH) (MBH)
Efficiency (in.) (in.) Wt. (lbs.)
with gas heat. Electric heaters are only available as minimum of 1.5-inch ESP. trouble light on the thermostat (if so equipped) and flashes MBH EER IPLV (kW) (%)
Valuable Features, Greater field-installed accessories. an alarm code on the control board LED. The five most Cooling only — — — — 1041

Easy Installation recent alarms are stored in memory for later review. 078 Electric Heat 9, 18, 24, 34 — — — 1061

Flexibility
77 9.0 9.45 2600 84
(61⁄2) Gas Heat — 120 96 80 1099

Service Friendly and Utility Connection


Non-volatile memory stores programmed values and
alarms if power is lost.
090
Gas Heat
Cooling only
Electric Heat


9, 18, 24, 34
180


144


80


1099
1051
1071
Indoor airflow components are easily reached to Utility connections can be made with minimum field labor. 86 9.0 10.15 3000 84
For dual-circuit reliability, all units have two simplify maintenance and adjustment, thanks to the Gas and electric knockouts are supplied in the unit System Protection (71⁄2) Gas Heat
Gas Heat


120
180
96
144
80
80 503⁄4H
1103
1103
compressors with independent refrigeration circuits. common, slide-out motor and blower assembly and bottom, as well as the side of the unit. A clearly identified Suction line freezestats are supplied on all units to Cooling only — — — — x 501⁄2W 1084
hinged, “tool-less” access panel design. 102 Electric Heat 9, 18, 24, 34 — — — 59W x 1104
For convenient installation, units are easily location is provided to mount a field-supplied electrical protect against the loss of charge and the occurrence of (81⁄2) Gas Heat
98 9.0 9.35 3000 90
— 120 96 80 1173
x 805⁄8D
installed on a roof curb, slab, roof rack, or Access panels have been placed in both condenser disconnect switch. coil frosting. Crankcase heaters and internal compressor Gas Heat — 180 144 80 89D 1173
frame. They are self-contained in a cabinet section walls. Rotation of the cover allows easy All units are shipped with 2-inch throw-away filters installed. protection are standard on all compressors. Every unit Cooling only — — — — 1116
sized to a common footprint, access to the condenser coils for has solid-core liquid line filter-driers and high and low 120 Electric Heat
120 9.0 9.10 4000 90
18, 24, 34, 54 — — — 1136
cleaning or inspection. (10) Gas Heat — 180 144 80 1206
installed on a common-sized roof

Advanced
pressure switches. Gas Heat — 240 192 80 1206
curb, and assembled on a rigid full Unit control board and ignition Cooling only — — — — 1195
perimeter base rail allowing for control board both use flash codes 150 Electric Heat
140 9.0 9.25 4500 90
18, 24, 34, 54 — — — 1215
3-way forklift access and overhead
rigging. Every unit is completely
charged, wired, piped, and tested at
the factory to provide for a quick
and easy installation.
to aid in diagnosing malfunctions.
Unique alarm codes quickly identify
the source of the unit alarm.
Standard, common filter sizes
Controls
While competitive units require added controls and options,
Predator rooftops provide a high level of control by including
Reliability
that Earns the
(121⁄2) Gas Heat
Gas Heat
* See 50 Hz Tech Guide Form 036-21044-001 for pertinent data.


180
240
144
192
80
80
1285
1285

HIGH EFFICIENCY DH MODELS (60 Hz only)


For improved IAQ, foil-faced
eliminate confusion when filters
need replacing.
these features as standard in our SureSense™ control board: Industry’s Best Warranty Nominal Gas Heat Capacity
insulation is used throughout the unit. ARI Ratings Sound Unit Curb Approx.
Integrated low-ambient During assembly, all Predator units undergo computer Size Electric Heat Seasonal
Non-corrosive, slide-out drain pan Model CFM Rating Input Output Dimen. Dimen. Operating
For competitive performance, control allows operation automated testing to confirm refrigerant charge, unit run (Tons)
(dB)
Capacity Efficiency
(in.) (in.) Wt. (lbs.)
permits easy cleaning. The drain pan MBH EER IPLV (kW)
(MBH) (MBH)
(%)
all standard efficiency units have in cooling mode down amperage, and 100% functionality of all components.
can be reversed to facilitate easy Cooling only — — — — 1041
a minimum 9.0 EER; high efficiency to 0°F outdoor ambient
condensate piping. The drain pan On-site durability is ensured by a lifetime-grade powder 078 Electric Heat 9, 18, 24, 34 — — — 1061
units can reach 11.5 EER; gas/ without additional 75 11.5 11.95 2600 84
also features a large slope to ensure paint verified to withstand a 750-hour salt spray test. (61⁄2) Gas Heat — 120 96 80 1099
electric units offer 80% Steady assistance. Optionally, Gas Heat — 180 144 80 1099
proper drainage.
State Efficiencies and employ the control board can All unit components are covered by a one-year Cooling only — — — — 1051
electronic spark ignition and power be programmed to lock limited warranty. Compressors and electric heaters 090 Electric Heat 9, 18, 24, 34 — — — 1071
vented combustion. Balanced Heating out the compressors are covered by five-year warranties. Aluminized steel (71⁄2) Gas Heat
Gas Heat
91 11.5 11.89 3400 84


120
180
96
144
80
80
1103
1103
The Predator offers “Ultimate Heating when the outdoor air heat exchangers are covered by a 10-year warranty; 503⁄4H
For hassle-free serviceability, temperature is low or Cooling only — — — — x 501⁄2W 1084
the motor and blower slide out Comfort” with a balance between optional stainless steel heat exchangers are covered 102 Electric Heat 9, 18, 24, 34 — — — 59W x 1104
first and second stage gas heating. when free cooling is available. (81⁄2) Gas Heat
99 11.5 12.50 3400 84
— 120 96 80 1173
as a common assembly. Speedy by a 10-year warranty. x 805⁄8D
Anti-short-cycle delay aids compressor life and reliability. Gas Heat — 180 144 80 89D 1173
access is provided through hinged, The first stage of a Predator unit provides 60% of the
Cooling only — — — — 1116
“tool-less” panels, which allow quick inspection heating capacity and 40% heating capacity on second Compressor life is also ensured by programmable minimum
120 Electric Heat 18, 24, 34, 54 — — — 1136
of components and areas, including the control stage. Balanced heating allows the unit to better run times. (10) Gas Heat
115 11.0 11.70 3840 90
— 180 144 80 1206
box, compressors, filters, indoor motor and blower, maintain desired temperatures when operating gas heat. Gas Heat — 240 192 80 1206
and the heating section. Cooling only — — — — 1195
Unit Voltage Limitations 150
(121⁄2)
Electric Heat
Gas Heat
146 10.0 10.70 4100 90
18, 24, 34, 54


180

144

80
1215
1285
Power Rating Minimum Maximum Gas Heat — 240 192 80 1285

208/230-3-60 187 253


460-3-60 414 506
575-3-60 518 630
380/415-3-50 342 456
Convertible, Dual-Compressor, 61/2 to 121/2-Ton Single Package (60 Hz)
The Predator Package ™

71/2 to 121/2-Ton Single Package (50 Hz)


At York Heating andAir Conditioning,
®

61/2 to 121/2 -Ton Packaged Units (60 Hz)


71/2 to 121/2 -Ton Packaged Units (50 Hz)
Control board Disconnect location Filter access (2" throw-away)
We Provide Comfort
Terminal block for
hi-voltage connection
w/screw connector
for T-stat wiring
(optional disconnect switch)
Filter drier (solid core)
WhereYou Live, Work, and Play
When it’s time to heat or cool Count on York to deliver a wide ®

YORK
Second model Condenser section
nameplate inside
hinged access panel your personal “Landmark,” the range of product choices for
Slide-out motor
and blower assembly YORK name assures you of the residential and light commercial
for easy adjustment
Dual stage cooling
for maximum comfort
and service highest standards of design and applications. Our offering
Belt-drive manufacture. York is the only includes heat pumps, split-

Commercial Package Units


blower motor
Compressor #2 access
(high-efficiency compressor Fortune 500 company focused system air conditioners, gas
Two-stage gas
w/crankcase heater)
heating to maintain solely on heating, ventilation, furnaces, air-handling units,
warm, comfortable
Base rails w/forklift slots
temperatures air conditioning, and refrigeration. and controls — plus chillers
(3 sides) and lifting holes
Power ventor motor
That gives us unique insight into and ventilation equipment for
designing products that meet your larger projects. We’re leading
Roof curbs in 8- and 14-inch 20-gauge aluminized
heights. Roof curbs for steel tubular heat exact requirements. We’re finding the way in developing efficient
transitioning from the exchanger for long life
Slide-out drain
York Sunline™ footprint
pan w/steel 3/4" (stainless steel option) solutions to today’s most critical and environmentally sound
to the DM/DH Series
FPT connection
footprint are also available
Intelligent control concerns — energy efficiency, choices for home and businesses.
(field-installed accessory)
board for safe and
Side entry Compressor #1 access efficient operation refrigerant alternatives, and indoor Let us create the environment
Tool-less door latch Optional convenience power and (high-efficiency compressor
power outlet control wiring w/crankcase heater) air quality — to improve the of success for you.
knockouts
indoor and outdoor environment.

AWide Range of Options Cooling Only


Cooling with
Electric Heat
The YORK Predator line also offers many Sub zero low ambient kit maintains stable cooling
valuable equipment options and accessories: when outdoor temperature is between 0°F and -20°F Cooling with
(field-installed accessory) Gas Heat
-60°F gas heat kit for gas heating in low ambient
temperatures (field-installed accessory) Motorized or manual outdoor air dampers
(field-installed accessories)
BAS option, consult the factory for availability
Phase monitors protect unit from phase imbalance,
Dirty filter switch (factory-installed option) phase drop, and reversed phase rotation (field-installed
Disconnect switch (factory-installed option) accessory; factory-installed standard on units with
Economizer available as a single enthalpy input. scroll compressors)
Exhaust options include barometric relief and Smoke detector (factory-installed option
power exhaust (available as factory-installed option or field-installed accessory)
or field-installed accessory) Stainless steel heat exchanger for all gas heat units
Electric heaters in 9kW to 54kW in voltages with 10-year parts warranty (factory-installed option)
of base units. Carries a five-year parts warranty Technicoat condenser coil coating for corrosion
(field-installed accessory) protection in harsh environments (factory-installed option)
Gas piping kit contains all necessary pipe fittings Thermostat for 24-volt or electro-mechanical
for bottom supply gas piping with external shut-off operation for two-stage heat/two-stage cool
(field-installed accessory) or two-stage cooling only configurations

Note: Not all listed options available on 50 Hz export models. Unitary Products Group
5005 York Drive, Norman, Oklahoma USA 73069
Subject to change without notice. www.york.com 036-11289-001 (800)
© 2000 York International Corporation. All rights reserved. Supersedes Nothing
Convertible, Dual-Compressor, 61/2 to 121/2-Ton Single Package (60 Hz)
The Predator Package ™

71/2 to 121/2-Ton Single Package (50 Hz)


At York Heating andAir Conditioning,
®

61/2 to 121/2 -Ton Packaged Units (60 Hz)


71/2 to 121/2 -Ton Packaged Units (50 Hz)
Control board Disconnect location Filter access (2" throw-away)
We Provide Comfort
Terminal block for
hi-voltage connection
w/screw connector
for T-stat wiring
(optional disconnect switch)
Filter drier (solid core)
WhereYou Live, Work, and Play
When it’s time to heat or cool Count on York to deliver a wide ®

YORK
Second model Condenser section
nameplate inside
hinged access panel your personal “Landmark,” the range of product choices for
Slide-out motor
and blower assembly YORK name assures you of the residential and light commercial
for easy adjustment
Dual stage cooling
for maximum comfort
and service highest standards of design and applications. Our offering
Belt-drive manufacture. York is the only includes heat pumps, split-

Commercial Package Units


blower motor
Compressor #2 access
(high-efficiency compressor Fortune 500 company focused system air conditioners, gas
Two-stage gas
w/crankcase heater)
heating to maintain solely on heating, ventilation, furnaces, air-handling units,
warm, comfortable
Base rails w/forklift slots
temperatures air conditioning, and refrigeration. and controls — plus chillers
(3 sides) and lifting holes
Power ventor motor
That gives us unique insight into and ventilation equipment for
designing products that meet your larger projects. We’re leading
Roof curbs in 8- and 14-inch 20-gauge aluminized
heights. Roof curbs for steel tubular heat exact requirements. We’re finding the way in developing efficient
transitioning from the exchanger for long life
Slide-out drain
York Sunline™ footprint
pan w/steel 3/4" (stainless steel option) solutions to today’s most critical and environmentally sound
to the DM/DH Series
FPT connection
footprint are also available
Intelligent control concerns — energy efficiency, choices for home and businesses.
(field-installed accessory)
board for safe and
Side entry Compressor #1 access efficient operation refrigerant alternatives, and indoor Let us create the environment
Tool-less door latch Optional convenience power and (high-efficiency compressor
power outlet control wiring w/crankcase heater) air quality — to improve the of success for you.
knockouts
indoor and outdoor environment.

AWide Range of Options Cooling Only


Cooling with
Electric Heat
The YORK Predator line also offers many Sub zero low ambient kit maintains stable cooling
valuable equipment options and accessories: when outdoor temperature is between 0°F and -20°F Cooling with
(field-installed accessory) Gas Heat
-60°F gas heat kit for gas heating in low ambient
temperatures (field-installed accessory) Motorized or manual outdoor air dampers
(field-installed accessories)
BAS option, consult the factory for availability
Phase monitors protect unit from phase imbalance,
Dirty filter switch (factory-installed option) phase drop, and reversed phase rotation (field-installed
Disconnect switch (factory-installed option) accessory; factory-installed standard on units with
Economizer available as a single enthalpy input. scroll compressors)
Exhaust options include barometric relief and Smoke detector (factory-installed option
power exhaust (available as factory-installed option or field-installed accessory)
or field-installed accessory) Stainless steel heat exchanger for all gas heat units
Electric heaters in 9kW to 54kW in voltages with 10-year parts warranty (factory-installed option)
of base units. Carries a five-year parts warranty Technicoat condenser coil coating for corrosion
(field-installed accessory) protection in harsh environments (factory-installed option)
Gas piping kit contains all necessary pipe fittings Thermostat for 24-volt or electro-mechanical
for bottom supply gas piping with external shut-off operation for two-stage heat/two-stage cool
(field-installed accessory) or two-stage cooling only configurations

Note: Not all listed options available on 50 Hz export models. Unitary Products Group
5005 York Drive, Norman, Oklahoma USA 73069
Subject to change without notice. www.york.com 036-11289-001 (800)
© 2000 York International Corporation. All rights reserved. Supersedes Nothing

You might also like