Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

E-22 GENERAL NOTES

yy
30000
E-18 8400 All dimensions are to be

A
D

B
F

E
checked on site,written
A B C D E F 9.000
1.500 dimensions rules over
4000 3200 scale dimensions. Any
1500 0.600 0.600 1.500 1.500 discrepancy in the

yy24

24
3000.600 0.6001200800 1900 300 1400 1900 3000 dimension is to be

00
4500 reported to the architect

1.
3800
before work commenses.

50
3800

0
1.500 0.200 3000 0.400 1000

0.200
1.300 3.000 2000 All dimensions are in
1200 1.500 1200 1200 1200

23
0.
A A millimeters unless

00
8 0
yy27
specified

0.200
A

A
yy28 yy28

1900

0
D-10 Drawings to be read in

. 1
4
28

0 .2 0.
conjuction with

1.000

0.200

0
60
0

00
60

E-28

E-29
specifications and all

54
W/C

00

yy26

0
W/C

55
9 40
00
relavant drawings

54

00
3.
0

1
50

50

.1

0
STORAGE 8.800
3.

LECTUER ROOM
7
5000

3
13

WORKSHOP 1

7200

8000
10600
00

00
13

1200

B
B B 0.600 0.600

BALCONY
300 800

6000

0.200

4000 3000.600 0.6001200 0.600

3800
CONFERENCE ROOM CONFERENCE ROOM
00

50
0.200 6000 0.200
80
50

80

00
yy24

0
3.
0

50
50

0.200

0.200
0
3.

E-28

yy26
C

C
1500
0

80
80

yy28
yy24 yy24

600
600

6200
0.500

C C

8400
500

700

E-18
1900 5800 0.200 1900 0.200 7200 0.200
2200

2200
0.200 7200 0.200
4400

4400

yy28
0.200

0.200

1900
LECTURERS OFFICE
0.500

0.500

E-20
LECTURERS OFFICE %
ATRIUM OPEN TO 77

0.600
6.

D
00
60 800

ABOVE
12

E-29

0.200
800

300
00

12
00
0
50

60
80

1200
3.

0.600 0.600

00
0

4000

3800
3.

BALCONY
300 800
2.

50

STORAGE
D D
50

0
0.200

0.200
00

0
40

9200
15

80
00

7
15

6.7

WORKSHOP 2
yy27
0

10600
yy yy

E
E-19
00

LECTUER ROOM

7200

8000
0
yy27 yy27

80
50000

40 00
15.18 %
LECTURERS OFFICE LECTURERS OFFICE

5
2.

3500
00
8800

8800
E-22

0.200
500

500

0.200
0

5
80
1.500

1.500

500
0.200

2
1500

30
1900

1900

0
E E 2000
0.200

F
1.
3000
0.500

0.500
8200

8200

00 5
1.500 1.500

600
600

0.500 0.500

24
0.500 0.500

0.200

1400 1900 3000


1.300

1400 0.4001000
0.200

0.200

00
1.500
4000 3200

1700
1700

OFFICE 1 9.000

A
B
G
OFFICE 2
0.200
600

600
4800

RECEPTION

D
6500

FIRST LEVEL
3000

E
F F
0
30

.8
300
0

0 1

C
1.12

yy
4000

80 0
0
1.700 0.200
0

0.200
1300

00
0 .0

E-22
8200
42
50 1
1. 20

2900

yy
0.400
00 0

1200 3.500 3600


0 10

A
D

B
F

E
0.200
0

9000
4.500

STAIRS 3000 0.400


600
2800

7%
6.7 0.400 1400 3.500 1800
3000
6.
77

G G
%

0.200

60
yy26 yy26
0.200 1.700

00
1.300 0.200
3.000

24
15.18 %

0
A

A
RAMP

0
1.000
28

0.200
00

54
6000

0
0

00
0
2000

yy26
14

5000

28
00

0 0

0
24

LECTUER ROOM
48

10800

COMPUTER LAB
00

8.288
B

B
B
7600 0.200 4.800 0.200 3500
6000 1200

3800 300
E-20 0.600
C D E F 300 0.600
0.600

5000
30000

0.200

0.200
GROUND FLOOR yy26 E-28
C

C
14500

yy28

0.600 1200
yy24 yy24
HORIZONTAL STEEL REINFORCEMENT BARS
6200

VERTICAL STEEL REINFORCEMENT BARS

800
9mmCERAMIC TILE GROUND LEVEL

E-18
0.600
yy28
REINFORCED CONCRETE SLAB TO STRUCTURAL ENGINERS DETAIL 50*75mm THICK BLINDING LAYER TO PROVIDE ACCURATE LEVEL

0.200

0.200
DARC/003J/2016

2000D 300
150mmTHICK WELL COMPACTED HARDCORE DISTRIBUTION BARS
E-20

%
WELL COMPACTED BACKFILLING 77 NDIRANGU DANIEL NJOROGE

0.600
6.
D

50*75mm THICK BLINDING LAYER TO PROVIDE ACCURATE LEVEL


E-29
MASS CONCRETE RATIO 1.2.4
1200
0.600 0.600
300 0.601

3800
D-01 RC COLUMN DETAIL (1) 1:50
3500
%

COMPUTER LAB
7
6.7

10800
E

E
FLOOR PLANS
yy27 yy27

LECTUER ROOM
15.18 % 3000
3600

40

5
0.200

4
00

00
RAIN WATER FULBORA
APP WATERPROOFING MEMBRANE
OR EQUIVELENT APPROVED
F

F
24

0.400
0

600
0

60
1600 0.400

0
50mm THICK PRECAST CONCRETE COPING 600 1400 3.500 1800

0
WITH 10mm DIA,DRIP MOULDING 35mm MACHINE CUT CORAL STONE
LAID TO FALL ON APP WATERPROOFING 9000
MEMBRAINE OR EQUIVALENT CEMENT/ 1200 3.500 3600
3000

A
B
G

SAND ,SCREED LAID TO FALL [MIN 5Omm] ON RC SLAB 8200

50mm SCREED LAID TO FALL


F

RC FLOOR SLAB SECOND LEVEL


E

FLATROOF DETAIL (2) 1:50

C
GSPublisherVersion 0.2.100.100

You might also like