Professional Documents
Culture Documents
Comunicacion Con ECM y Flash
Comunicacion Con ECM y Flash
Page 1 of 3
Cerrar SIS
Pantalla anterior
Instrucción Especial
ECM Communication and Flashing Issues{0709, 1901, 7620}
Número de medio -REHS3267-00 Fecha de publicación -25/08/2006 Fecha de actualización -25/08/2006
i02602550
Introduction
There have been numerous reports from technicians about being unable to flash an ECM or technicians
unable to communicate with an ECM.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe... 8/28/2006
Búsqueda del medio - REHS3267 - ECM Communication and Flashing Issues{0709, 190... Page 2 of 3
When you use the Caterpillar CommAdapter II, ensure that the data link adapter cable is the 207-6845
Adapter Cable As . The data link adapter cable is the cable that plugs into the round connector on the top
end of the Caterpillar CommAdapter II. The previous cable with the braided shield may cause
intermittent communication problems. Replace the cable with the braided shield with the 207-6845
Adapter Cable As .
2. Select "Preferences".
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe... 8/28/2006
Búsqueda del medio - REHS3267 - ECM Communication and Flashing Issues{0709, 190... Page 3 of 3
number and view the selected data link to the left. The options are ATA, J1939, or CDL. Disconnect the
appropriate wires from your harness. Retry the connection. This will force the ECM to communicate
over a different data link and this may resolve the error.
Additional Assistance
If additional assistance is required, Contact your Technical Communicator.
Copyright 1993 - 2006 Caterpillar Inc. Mon Aug 28 11:22:16 CDT 2006
Todos los derechos reservados.
Red privada para licenciados del SIS.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe... 8/28/2006