Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

TABLE OF CONTENTS REPUBLIC OF THE PHILIPPINES

rizal national high school DEPARTMENT OF PUBLIC WORKS


AND HIGHWAYS
AR SITE DEVELOPMENT PLAN
Office of the Building Official
1 VICINITY MAP
PERSPECTIVES
SITE LOCATION
george town AR GROUND FLOOR PLAN
subdivision
2 SECOND FLOOR PLAN
LAND USE AND ZONING
subdivision road

AR FRONT ELEVATION
george town 3 RIGHT SIDE ELEVATION
subdivision REAR ELEVATION
LEFT SIDE ELEVATION
subdivision road
CROSS SECTION
THIS LONGITUDINAL SECTION
SITE ROOF PLAN
AR SCHEDULE OF DOORS AND
4 WINDOWS

baydid st.
LINE AND GRADE

iglesia ni
cristo
FOUNDATION PLAN
to ramon
ST SECOND FLOOR FRAMING PLAN
national road
to city proper 1 ROOF FRAMING PLAN
charina's
hotel ST STRUCTURAL DETAILS
2
ARCHITECTURAL
ST SLAB DETAILS
3

AR PERSPECTIVE VIEW AR VICINITY MAP


STAIR DETAILS
ST HIP TRUSS DIAGRAM
4 HIP TRUSS DETAILS
1-1 NOT SCALED 1-3 NOT SCALED
10m.
2.5m. 1m. 6.5m.
3
2 S 00°35' E
1m.
THIS SITE GROUND FLOOR WATER
LAYOUT
SECOND FLOOR WATER
STRUCTURAL

LAYOUT
PL GROUND FLOOR SANITARY
1 LAYOUT
SECOND FLOOR SANITARY
-15 LAYOUT
T-D
2.65m.

LO SEPTIC VAULT AND CATCH


BASIN DETAILS
-14
T-D
LO PL WATER AND SANITARY

-D
-13 2 ISOMETRIC VIEW
L OT
SANITARY
S 89°24' W

-12
-D
OT
6.5m.

L
9.14m.
N 89°24' E

-11
T-D
10.05m.

LO
-10 GROUND FLOOR LIGHTING
T-D
LO S LAYOUT

-9
S

7-D
E SECOND FLOOR LIGHTING
4.85m.

-A-
C LAYOUT

-8
A EL

32
7-D
GROUND FLOOR POWER
1

91
D

-A-
A LAYOUT

T
O
32

LO
R SECOND FLOOR POWER ELECTRICAL
91
-7 LAYOUT
T-D T
LO LO
6
1.3m.

-
T -D RISER DIAGRAM
LO EL
2 SCHEDULE OF ELECTRICAL
-5 LOADS
T-D -3
LO
T-D
AR SITE LOCATION
1.55m.

LO
1m.
4 -2

N 05°46' W
L OT
-D
1-4 NOT SCALED
-1
1 10.04m. LO
T-D MECHANICAL

AR SITE DEVELOPMENT PLAN


1-2 NOT SCALED
DESIGNED BY: PRC NO. 0080151 REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY: 10/28/2023
AR
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. 2997409 WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY PERSPECTIVE VIEW
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE
DATE ISSUED: 01/29/2021 COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK SITE DEVELOPMENT PLAN
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN
VICINITY MAP
CIVIL ENGINEER
PLACE ISSUED: SANTIAGO CITY
TIN : 927-517-661
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER SITE LOCATION 1
A B C D
6.5m. A B C D
3.5m. 4.6m. 1.9m. 6.5m.

X 1m. X 3.5m. 4.6m. 1.9m.


PROPERTY LINE PROPERTY LINE

1m.
1m.

W-3 D-1 W-4 W-1 W-4

3 3 W-2

1.5m.

1.5m.
LANAI

WALKWAY
D-2 C.R. D-2 C.R.
TRELLIS
KITCHEN
3.5m.

3.5m.
15 14 13 12 1110 9 W-1 16 15 14 13 12 1110 9

F I R E W A L L
LINE
F I R E W A L L
LINE

BEDROOM 3 DN.

2m.

2m.
8 8
W-2

PROPERTY
6.5m.

6.5m.
UP D-1
PROPERTY
6.5m.

6.5m.
1 2 3 4 5 6 7 4 5 6 7
CARPORT
2 2 D-1
BEDROOM 2 BEDROOM 1

4.65m.
DINING

3m.

3m.
3m.

3m.
4.5m.

W-1
W-1 LIVING

D-1 D-1 W-1

1 W-1 1 W-1

1.64m.
1m.
BALCONY

1.64m.
2.55m.

ENTRY

ENTRY GATE
PROPE
RTY LINE
Y PROPE
RTY LINE
Y
3.25m. 3.25m. 3.5m. 3.25m. 3.25m.
3.5m.
6.5m. 6.5m.

AR GROUND FLOOR PLAN AR SECOND FLOOR PLAN


2-1 SCALE 1:80MTS. 2-2 SCALE 1:80MTS.

DESIGNED BY: PRC NO. 0080151 REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY: 10/28/2023
AR
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. 2997409 WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY GROUND FLOOR PLAN
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE
DATE ISSUED: 01/29/2021 COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK SECOND FLOOR PLAN
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN

CIVIL ENGINEER
PLACE ISSUED: SANTIAGO CITY
TIN : 927-517-661
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER 2
A B D 1 2 3
0.51m.
C APEX APEX
B C D APEX
OF ROOF OF ROOF OF ROOF

1.31m.

1.31m.
0.8m.

TOP OF TOP OF TOP OF


BEAM BEAM SEE TRUSS DETAILS BEAM

C.R.
3m.

3m.

3m.
0.78m.
0.54m.

2ND FIN. 2ND FIN. BEDROOM 3 2ND FIN.


FLOOR LINE FLOOR LINE FLOOR LINE
0.3m.

C.R.
KITCHEN
3.00m.

3.00m.

3.00m.
FINISH FINISH FINISH
FLOOR LINE FLOOR LINE FLOOR LINE
NATURAL NATURAL NATURAL
0.15m.

0.15m.

0.15m.
GRADE LINE GRADE LINE GRADE LINE

AR FRONT ELEVATION AR RIGHT SIDE ELEVATION AR CROSS SECTION


3-1 SCALE 1:110MTS. 3-2 SCALE 1:110MTS. 3-5 SCALE 1:110MTS.

D C B A 3 2 1 APEX
3 2 1 APEX
APEX
OF ROOF OF ROOF OF ROOF
1.31m.

1.31m.

1.31m.
TOP OF TOP OF TOP OF
BEAM BEAM SEE TRUSS DETAILS BEAM
3m.

3m.

3m.
BEDROOM 1

2ND FIN. 2ND FIN. 2ND FIN.


FLOOR LINE FLOOR LINE FLOOR LINE
3.00m.

3.00m.

3.00m.
LIVING

FINISH FINISH FINISH


FLOOR LINE FLOOR LINE FLOOR LINE
NATURAL NATURAL NATURAL
0.15m.

0.15m.

0.15m.
GRADE LINE GRADE LINE GRADE LINE

AR REAR ELEVATION AR LEFT SIDE ELEVATION AR LONGITUDINAL SECTION


3-3 SCALE 1:110MTS. 3-4 SCALE 1:110MTS. 3-6 SCALE 1:110MTS.

DESIGNED BY: PRC NO. 0080151 REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY: 10/28/2023 FRONT ELEVATION
AR
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. 2997409 WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY RIGHT SIDE ELEVATION
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE REAR ELEVATION
DATE ISSUED: 01/29/2021 COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK LEFT SIDE ELEVATION
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN

CIVIL ENGINEER
PLACE ISSUED: SANTIAGO CITY
TIN : 927-517-661
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER
CROSS SECTION
LONGITUDINAL SECTION
3
0.9m. 0.8m. 1.2m.

2.5m. 1m. 6.5m.

PROPERTY LINE

1.2m.
1m.
LINE

2.1m.

2.1m.

0.9m.
PROPERTY

DESCRIPTION: SINGLE SWING DESCRIPTION: SINGLE DESCRIPTION: SLIDING TYPE WINDOW

F I R E W A L L
D-1 PANEL DOOR D-2 FINISH:
SWING DOOR
PRE FABRICATED W-1 GLAZING 41" GLASS
POWDER COATED
FINISH: WOOD FRAMING
LOCATION: AS SHOWN LOCATION: C.R. LOCATION: AS SHOWN
NO. OF SETS: 5 SETS NO. OF SETS: 2 SETS NO. OF SETS: 7 SETS

6.5m.
0.7m.

1m. 0.6m.

1.2m.
4.35m.
3.15m.
5.15m.

0.6m.
0.6m.
1.2m.

1.5m.
1.2m.
0.5m.0.5m.

0.9m.
1.3m.
DESCRIPTION: SLIDING TYPE WINDOW DESCRIPTION: SLIDING TYPE WINDOW DESCRIPTION: SLIDING TYPE WINDOW
1.58m.

GLAZING 41" GLASS GLAZING 41" GLASS GLAZING 41" GLASS


1m. W-2 POWDER COATED
W-3 POWDER COATED
W-4 POWDER COATED
LOCATION: AS SHOWN LOCATION: KITCHEN LOCATION: C.R.
RTY LINE NO. OF SETS: 2 SETS NO. OF SETS: 1 SET NO. OF SETS: 2 SETS
PROPE

AR ROOF PLAN AR SCHEDULE OF DOORS AND WINDOWS


4-1 SCALE 1:70MTS. 4-2 NOT SCALED

DESIGNED BY: PRC NO. 0080151 REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY: 10/28/2023
AR
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. 2997409 WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY ROOF PLAN
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE
DATE ISSUED: 01/29/2021 COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK SCHEDULE OF DOORS
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN SCHEDULE OF WINDOWS
CIVIL ENGINEER
PLACE ISSUED: SANTIAGO CITY
TIN : 927-517-661
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER 4
A B C D A B C D

0.2m.
1m. 3.25m. 3.25m.
C - PURLINS
3.65m. 3.1m. 3.25m. 3.65m. 3.1m. 3.25m. DS DS DS

0.8m.
1m.
F1 - C1 F1 - C1 TIE BEAM F1 - C1
3 TIE BEAM TIE BEAM
3 20 X 40 cm. BEAM 20 X 40 cm. BEAM

CROSS BRACING
20 X 30 cm. 20 X 30 cm.
15 cm. THICK CONC.
ROOF BEAM ROOF BEAM

20 X 40 cm. BEAM

20 X 40 cm. BEAM

20 X 40 cm. BEAM
FLOOR SLAB
F2-C2 WF

ROOF BEAM

ROOF BEAM

ROOF BEAM
20 X 30 cm.

20 X 30 cm.

20 X 30 cm.
TIE BEAM

TIE BEAM

TIE BEAM

TIE BEAM

3.35m.

3.35m.

3.35m.
3.5m.

3.5m.

3.5m.
15 cm. THICK CONC.
WF FLOOR SLAB

F2-C2 F1 - C1 F1 - C1 F1 - C1
2 2 20 X 30 cm.
20 X 40 cm. BEAM 20 X 40 cm. BEAM
20 X 30 cm. 20 X 30 cm.
ROOF BEAM ROOF BEAM

HIP TRUSS 1
ROOF BEAM

20 X 40 cm. BEAM

20 X 40 cm. BEAM

20 X 40 cm. BEAM
ROOF BEAM
TIE BEAM

20 X 30 cm.
TIE BEAM

TIE BEAM

TIE BEAM
3m.

3m.

3m.

3m.

3m.
ROOF BEAM

ROOF BEAM

ROOF BEAM
20 X 30 cm.

20 X 30 cm.

20 X 30 cm.
15 cm. THICK CONC. 15 cm. THICK CONC.
FLOOR SLAB FLOOR SLAB

4m.
F2-C2
20 X 30 cm. 20 X 30 cm. 20 X 30 cm.
TIE BEAM F1 - C1 TIE BEAM F1 - C1 TIE BEAM F1 - C1 ROOF BEAM 20 X 40 cm. BEAM 20 X 40 cm. BEAM ROOF BEAM ROOF BEAM
1 1

1m.

1m.
15 X 20 cm. BEAM

3.65m. 3.1m. 3.25m. 1m. 3.25m. 3.25m.

3.65m. 3.1m. 3.25m.

ST FOUNDATION PLAN ST SECOND FLOOR FRAMING PLAN ST ROOF FRAMING PLAN


1-1 SCALE 1:100MTS. 1-2 SCALE 1:100MTS. 1-3 SCALE 1:100MTS.

DESIGNED BY: PRC NO. 0080151 REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY: 10/28/2023
ST
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. 2997409 WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY FOUNDATION PLAN
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE SECOND FLOOR PLAN ROOF
DATE ISSUED: 01/29/2021 COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK FRAMING PLAN
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN

CIVIL ENGINEER
PLACE ISSUED: SANTIAGO CITY
TIN : 927-517-661
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER 1
1.2m. 1.2m. 1m.
0.2 0.2 0.25m.
12-16 MM DIA.
16-16 MM DIA. 16-16 MM DIA. MATTING BARS

0.25
MATTING BARS MATTING BARS SPACED ON
SPACED ON SPACED ON CENTER BOTH
CENTER BOTH CENTER BOTH WAYS
WAYS WAYS

1m.
0.4m.

0.4m.
1.2m.

1.2m.
8-16 MM DIA. 8-16 MM DIA.
6-16 MM DIA.
VERTICAL BARS VERTICAL BARS
VERTICAL BARS

ST F2 - C2 PLAN
F1 - C1 PLAN F1 - C1 PLAN 2-3 NOT SCALED
ST ST @FIREWALL
2-1 NOT SCALED 2-2 NOT SCALED

FOOTING SCHEDULE
FOOTING THICKNESS MAIN REINFORCEMENT
MARK MM DEPTH
10 MM. DIA. SIZE DOUBLE

0.15
VERTICAL
BARS SPACED A B ALONG A ALONG B D
FFL. @ 800 MM. A F-1 1 200 MM X 1 200 MM 400 8-16 MMØ 8-16 MMØ 1 500 MM
O.C B.W
NGL. F-2 1 000 MM X 1 000 MM 300 6-16 MMØ 6-16 MMØ 1 200 MM

B
10 MM. DIA
HORIZONTAL
10 MM. DIA.
0.30m.
FOOTING
HORIZONTAL
BARS SPACED
@ 300 MM. O.C B.W
BARS EVERY
3 LAYER OF COLUMN SCHEDULE

0.15
C.H.B
6-16 MM DIA. COLUMN
FFL. MARK MAIN
VERTICAL BARS SIZE REINFORCEMENT TIES
NGL.
0.35m. 0.30

10 MM. DIA. STIRRUPS A


1.50m.

A B
SPACED AS FOLLOWS: 10mm Ø TIES SPACED:
5 @ 50mm; 4 @ 75mm;

1.00 m.
5-50 MM., 4-75 MM., 5" C.H.B
C-1 200 MM X 400 MM 8-16MMØ

0.60 m.
4 @ 100mm; 4 @ 50mm;

B
4-100 MM & 200 MM. @ REST 3-12 MM. C-2 250 MM X 250 MM 4-16MMØ AND REST @ 200mm
CONCRETE O.C.
FOOTING
BARS
BEAM SCHEDULE

0.25
0.40m.

BEAM AT
MARK AT MIDSPAN STIRRUPS
SIZE SUPPORT
ST WF PLAN AND SECTION 4-16 MMØ TOP BAR 2-16 MMØ TOP BAR 10mm Ø TIES SPACED:
2-5 NOT SCALED 5 @ 50mm; 4 @ 75mm;
ROOF BEAM 200 MM X 300 MM 2-12 MMØ MID BAR 2-12 MMØ MID BAR 4 @ 100mm; 4 @ 150mm;
ST F1 - C1 SECTION 2-16 MMØ BOTTOM BAR 4-16 MMØ BOTTOM BAR
AND REST @ 200mm O.C.
2-4 NOT SCALED
5-16 MMØ TOP BAR 3-16 MMØ TOP BAR 10mm Ø TIES SPACED:
5 @ 50mm; 4 @ 75mm;
REINFORCED 2-12 MMØ MID BAR 2-12 MMØ MID BAR
200 MM X 400 MM 4 @ 100mm; 4 @ 150mm;
SHOWN @ BEAM SCHEDULE FLOOR BEAM
3-16 MMØ BOTTOM BAR 5-16 MMØ BOTTOM BAR
AND REST @ 200mm O.C.
L/2 L/2
L/4 L/4 L/4 L/4 10mm Ø TIES SPACED:
3-12 MM Ø TOP BAR 5 @ 50mm; 4 @ 75mm;
TIE BEAM 200 MM X 300 MM 4 @ 100mm; 4 @ 150mm;
3-12 MMØ BOTTOM BAR
AND REST @ 200mm O.C.

SHOWN @ BEAM SCHEDULE

ST REINFORCED BEAM SECTION


2-6 NOT SCALED

DESIGNED BY: PRC NO. 0080151 REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY: 10/28/2023
ST
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. 2997409 WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE
DATE ISSUED: 01/29/2021 COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK AS SHOWN
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN

CIVIL ENGINEER
PLACE ISSUED: SANTIAGO CITY
TIN : 927-517-661
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER 2
CONTINUOUS BOTTOM BARS BEND BARS ALTERNATE
WITH CONTINUOUS BARS
CONTINUOUS TOP BARS
EXTRA BARS ON TOP OF CONT.
BARS CUT AT L / 4.

12 Ø mm.RSB Bent Bars @


SPC. 0.15 m. O.C. B.W
12 Ø mm.RSB CUT Bars @
0.13 m. O.C. B.W
LENGTH

12 Ø mm.RSB TEMP Bars @


SPC. 0.15 m. O.C. B.W

A A

PLAN
LENGTH

12 Ø mm.RSB CUT Bars @ 12 Ø mm.RSB Bent Bars @


0.13 m. O.C. B.W SPC. 0.15 m. O.C. B.W

LENGTH 12 Ø mm.RSB CUT Bars @


0.13 m. O.C. B.W

12 Ø mm.RSB TEMP Bars @


L/4 L/4 SPC. 0.15 m. O.C. B.W

ST CONCRETE SLAB DETAILS


3-1 NOT SCALED
DESIGNED BY: PRC NO. 0080151 REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY: 10/28/2023
ST
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. 2997409 WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE
DATE ISSUED: 01/29/2021 COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK CONCRETE SLAB
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN
DETAILS
CIVIL ENGINEER
PLACE ISSUED: SANTIAGO CITY
TIN : 927-517-661
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER 3
12mmØ BAR Sp.@ 0.20m. O.C.
0.125 M. THK. CONC. SLAB SPOT DETAIL - B & 16mm ØTRANSVERSE BARS
Sp.@ 0.30m.O.C. 0.25m.
W/ 12 mm Ø RSB @ 0.20
10 mm Ø BENT &
M.O.C. TEMP. BARS @ 0.20 M.O.C.

.25 M.

5-12 mm Ø MAIN BARS @


0.25 M.O.C. W/ 12 mm Ø
TEMP..BARS @0.30 M.O.C.

.20M.
.20 M.
5-12 mm Ø MAIN BARS
@ 0.25 M.O.C. W/ 12
mm Ø TEMP..BARS
10mmØ BAR
@0.30 M.O.C. Sp. AS SHOWN
10mmØ BAR
CONCRETE SLAB Sp. AS SHOWN

GROUND FLOOR LEVEL

.10m.
5-12 mm Ø FTNG.BARS E.W.

0.4m
4-12mmØ HOR.BAR
Sp. AS SHOWN

.25m.
ST STAIR DETAILS
.40 M.

4-1 NOT SCALED


.60m.
.60 M.

PRE-PAINTED G.A LONG


SPAN 24 METAL ROOFING SLIT. GA. 26 G.I FLASHING
PURLIN 3" TEXT SCREW
CONNECTOR
.20 M.
.60 M. 16 MM. 2-2 21' X 2 21" ANGLE BAR
SAG ROD, TOP CHORD
PLAIN BAR

2" X 4"
C-STEEL

0.89m.
PURLINS 10 MM. DIA.
0.2m.

0.8m.
VERTICAL BARS
6" C.H.B PARAPET
2" X 2" WEB WALL
MEMBER

1
2-2 12' X 2 21" 4" THICK
0.8m. 0.5m. 1m. 1m. 1m. 1m. 1m. 1m. 1m. ANGLE BAR FISH PLATE
BOTTOM CHORD
8.3m.
WIRE BASKET

ST HIP TRUSS DIAGRAM STRAINER

4-2 NOT SCALED GA. 24 SPANISH


GB. GUTTER

ST HIP TRUSS DETAILS 3" DIA. PVC

4-3 NOT SCALED DOWNSPOUT

DESIGNED BY: PRC NO. 0080151 REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY: 10/28/2023
ST
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. 2997409 WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY STAIR DETAILS
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE
RESIDENTIAL BUILDING HIP TRUSS DIAGRAM
DATE ISSUED: 01/29/2021 COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN
MR. TYRONE H. BUCK HIP TRUSS DETAILS
CIVIL ENGINEER
PLACE ISSUED: SANTIAGO CITY
TIN : 927-517-661
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER 4
4" X 4" PVC
WYE RISER

4" DIA.
90 DEG. ELBOW 1 1 4" X 4" PVC
2" PVC RISER 2" PVC RISER PVC WYE
PVC TEE WYE RISER
FAU.
D.S. D.S. D.S. D.S. D.S. D.S.
LAV.
LAV.
SHO.
LAV.
SHO. LAV. W.C. F.D. LAV.
LAV. W.C. W.C. W.C.
C.B. F.D.

50mm DRAINAGE
PIPE
C.O.
PVC PIPE

C.B.

SEPTIC VAULT
50mm DRAINAGE
2"
1

PIPE
CHECK VALVE
WATER METER
GATE VALVE C.B.

PL G.F. WATER LAYOUT PL S.F. WATER LAYOUT PL G.F. SANITARY LAYOUT PL S.F. SANITARY LAYOUT
1-1 SCALE 1:100MTS. 1-2 SCALE 1:100MTS. 1-3 SCALE 1:100MTS. 1-4 SCALE 1:100MTS.

0.60 0.60
1.00 1.60 1.00 1.60 HANDHOLE MANHOLE HANDHOLE MANHOLE HANDHOLE
100 MM DIA. 0.40 12mm Ø 0.40
HH = HANDHOLE SANITARY TEE HANDLE BAR REM0VABLE CONC.
100 MM SOIL PIPE 75mm. Ø DOWNSPOUT REM0VABLE CONC.
(TYPICAL) COVER
COVER
OUTLET INLET PVC PIPE
OUTLET INLET
10 MM DIA. 10 MM DIA. 10mm Ø HOR. BAR
10mm. Ø RSB SPCD. @ 200mm. O.C
BARS O.C HORIZONTAL
PEA GRAVEL DIGESTION CHAMBER AS SHOWN
B.W AS SHOWN PEA GRAVEL DIGESTION CHAMBER STEEL BARS
1.20 1.20
400mm x 400mm 1
2 "CEMENT 10 MM DIA. BARS CONCRETE
MANHOLE (TYPICAL) PLASTER FIN.
@ 0.3 M 0.C SLAB FLOOR 75mm Ø PVC
10 MM DIA. 75mm Ø PVC 75mm Ø PVC PIPE INLET
4"THICK CONCRETE SLAB 10 MM DIA. REINF. PIPE INLET PIPE OUTLET 75mm Ø PVC
VERTICAL PIPE OUTLET
WITH CEM. PLASTIC PIN BARS @ 0.45 m
STEEL BARS
3-10 MM DIA. O.C B.W 10mm. Ø U-BARS SPCD. 75mm Ø DOWNSPOUT
SPACED @ PLAN
LONGITUDINAL BARS AS SHOWN SECTION / ELEVATION PVC PIPE
.80 M. B.W

PL SEPTIC VAULT COVER PLAN PL SEPTIC VAULT PLAN PL SEPTIC VAULT SECTION PL CATCH BASIN DETAILS
1-5 NOT SCALED 1-6 NOT SCALED 1-7 NOT SCALED 1-8 NOT SCALED

DESIGNED BY: PRC NO. REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY:
PL
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY WATER LAYOUT
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE SANITARY LAYOUT
DATE ISSUED: COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK SEPTIC VAULT DETAILS
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN

SANITARY ENGINEER/REGISTERED MASTER PLUMBER


PLACE ISSUED:
TIN :
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER
CATCH BASIN DETAILS
1
L
L
A
W
E
I R
F

R
SE
RI O.
C SH
1 2" PV . C
V. .C PV ER
LA W X 4" RIS
4" WYE S.
D.
.
. F.D
V. .C
LA W
S.
D.

S.
D.

C
S. PV ER
D. X 4" RIS
4" WY E

. YE S.
R
SE LAV. DIA W D.
RI O. 4" VC
C P .D.
PV SH .F
1 2" . .C
V. . C V. W
W LA W LA
U. .
BO E
EL TE FA D.S
.
DEG PVC
90 V.
V. LA
LA S.
D.

B. O.
E
C. GE C.
PIP VE E AIN
A
AL TER
C PIPDR
PV 2 "1
C K V ME VE mm UL
T
E R L
CH ATE E VA
50 VA
W AT B.
IC
C.
G E PT
AG SE
IN E A
PIPDR
m m
50
B.
C.

PL WATER LAYOUT ISOMETRIC VIEW PL SANITARY LAYOUT ISOMETRIC VIEW


2-1 NOT SCALED 2-2 NOT SCALED

DESIGNED BY: PRC NO. REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY:
PL
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY WATER LAYOUT
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE ISOMETRIC VIEW
DATE ISSUED: COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK SANITARY LAYOUT
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN

SANITARY ENGINEER/REGISTERED MASTER PLUMBER


PLACE ISSUED:
TIN :
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER
ISOMETRIC VIEW
2
1 21" PVC PIPE 1 21" PVC PIPE
RISER UP RISER UP
FROM LPP AT FROM LPP AT
GROUND FLOOR. GROUND FLOOR.

S S REF. A.C.U.

5 4
9
R.A.
S
3
S2
7 6
2
8

S2 S2
S3 A.C.U. A.C.U.
S2
1

S2
S3

EL G.F. LIGHTING LAYOUT EL S.F LIGHTING LAYOUT EL G.F. POWER LAYOUT EL S.F POWER LAYOUT
1-1 SCALE 1:100MTS. 1-2 SCALE 1:100MTS. 1-3 SCALE 1:100MTS. 1-4 SCALE 1:100MTS.

DESIGNED BY: PRC NO. REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY:
EL
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY LIGHTING LAYOUT
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE POWER LAYOUT
DATE ISSUED: COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN

PROFESSIONAL ELECTRICAL ENGINEER


PLACE ISSUED:
TIN :
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER 1
INCOMING POWER ELECTRICAL NOTES:
SERVICE 1. ALL ELECTRICAL INSTALLATION WORKS HEREIN
LEGEND SINGLE PHASE, 2 WIRES SHALL BE DONE IN ACCORDANCE WITH THESE PLANS &
230 VOLTS,60 HERTZ SPECS, AND THE APPLICABLE PROVISIONS OF THE
40 WATTS CIRCULAR TYPE CEILING LAMP
LPP LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE,
50 WATTS RECESSED TYPE VERTICAL DOWNLIGHT SERVICE M IT'S RULES & REGULATIONS, OF THE LOCALENFORCING
ENTRANCE AUTHORITY & THE REQUIREMENTS OF THE LOCAL
WALL LAMP POWER COMPANY. THE ELECTRICAL WORK SHALL BE
60 AT
UNDER THE IMMEDIATE SUPERVISION OF A DULY
CONVENIENCE OUTLET
1 L.O. L.O. LICENSED PROFESSIONAL ELECTRICAL ENGINEER.
15 AT 15 AT
2
ACU AIR CONDITIONING UNIT
C.O. REF. 2. THE ELECTRICAL SERVICE VOLTATAGE SHALL BE 2
REF
3 20 AT 30 AT
4
REFRIGERATOR WIRES, 220 VOLTS.
RA. C.O.
RA. 5 30 AT 20 AT 6
RANGE
A.C.U. A.C.U. 3. THE ELECTRICAL WIRING INSTALLATION SHALL BE
7 30 AT 30 AT 8 DONE IN PVC PIPES. IF NOT INDICATED OR SPECIFIED, IT
INTERNET / TV JACK
A.C.U. SPARE
9 10 SHALL BE DONE AS FOLLOWS:
M 30 AT 20 AT
METER SPACE
11 20 a. SERVICE ENTRANCE - RIGID STEEL
1
CIRCUIT HOMERUNS (SWITCH) CONDUIT (RSC) OR INTER-MEDIATE METTALIC CONDUIT
5.5mm²
2 CIRCUIT HOMERUNS GROUND WIRE (IMC).
b. UNDERGROUND & EMBEDDED IN
LIGHTING AND POWER PANELOARD CONCRETE SLAB & WALLS PVC CONDUITS OR PE PIPES
RISER DIAGRAM SCHEDULE 40. FLEXIBLE CONDUITS SHALL BE USED
WHERE REQUIRED.

COMPUTATION OF LOAD ANALYSIS 4. ALL WIRES SHALL BE COPPER & THERMOPLASTIC


2 INSULATED TYPE " TW " UNLESS OTHERWISE INDICATED.
L.O. C.O. OTHERS VOLTS VA AMPERE BRANCH PROTECTION SIZE OF WIRE IN mm THHN SIZE OF CONDUIT USE PHELPS DODGE OR COLUMBIA BRAND.
CKT NO.
AT AF POLE KAIC COPPER WIRE 20mmØ 5. THE CONTRACTOR SHALL VERIFY & ORIENT THE
15mmØ ACTUAL LOCATION OF SERVICE ENTRANCE FOR
1 14 230 1400 6.09 15 100 2 10 2-3.5 LINE CONNECTION TO THE POWER SUPPLY.

2 19 (2F) 230 1900 8.26 15 100 2 10 2-3.5 LINE 15mmØ


6. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES,
15mmØ PANELBOARDS, LIGHTING FIXTURES& ALL
3 8 230 1600 6.95 20 100 2 10 2-3.5 LINE NON-CURRENT CARRYING METAL PARTS SHALL BE
15mmØ PROPERLY GROUNDED.
4 REF. OUTLET 230 1000 4.34 30 100 2 10 2-3.5 LINE
5 R.A. OUTLET 230 2800 12.17 30 100 2 10 2-3.5 LINE 15mmØ 7. ALL FEEDERS & BRANCH CIRCUIT HOMERUNS
SHALL BE INSTALLED AS INDICATED ON THE PLANS.
6 9 (2F) 230 1800 7.82 20 2-3.5 LINE 15mmØ BRANCH CIRCUIT HOMERUN WIRES SHALL BE
100 2 10 INSTALLED IN INDIVIDUAL HOMERUN CONDUITS.
7 ACU(1.5 HP) 230 2300 10.00 30 100 2 10 2-5.5 LINE, 1-3.5 GROUND 20mmØ
8. ANY DISCREPANCY IN LOCATION & RATINGS OF
8 ACU(1.5 HP) 230 2300 10.00 30 100 2 10 2-5.5 LINE, 1-3.5 GROUND 20mmØ EQUIPMENT AND/OR APPARATUS TO BE INSTALLED
SHALL BE VERIFIED WITH THE OWNER OR HIS
9 ACU(1.5 HP) 230 2300 10.00 30 100 2 10 2-5.5 LINE, 1-3.5 GROUND 20mmØ AUTHORIZED REPRESENTATIVE, & CHANGES SHALL BE
MADE ACCORDINGLY.
10 SPARE 230 1000 4.34 20 100 2 10 PROVIDE FISH WIRE 20mmØ
9. ALL MATERIALS & EQUIPMENT TO BE USED &
11 SPACE 230 1000 4.34 20 100 2 10 PROVIDE FISH WIRE 20mmØ INSTALLED SHALL BE BRAND NEW, OF THE APPROVED
TYPE FOR THE LOCATION AND PURPOSE INTENDED.
TOTAL 85.17
10. ALL POWER & CONVENIENCE OUTLETS SHALL BE
GROUNDING TYPE.
COMPUTATION OF LOAD ANALYSIS
CORRECTION FACTOR: 11. THE MOUNTING HEIGHTS OF WIRING DEVICES
SHALL BE AS FOLLOWS:
T = [85.17+HML(.25)] 90 X .91 = 81.9
a. LIGHT SWITCHES - 1.40 M. ABOVE
= [85.17+12.17(.25)] SIZE OF FEEDER CONDUCTOR: FFL
b. CONVENIENCE OUTLETS - 0.30 M.
T =88.21 amp. · USE 2-22mm 2 THHN, 1-8mm ABOVE FFL
c. TELEPHONE OUTLETS - 0.30 M.
ABOVE FFL
@ 80% DF SIZE OF FEEDER PROTECTION: d. PANELBOARDS & CABINETS - 1.40 M.
ABOVE FFL
T =88.21 amp.(80%) · 80AT and 100 AF, 2-POLE, 230V, 25KAIC BOLT-ON CKT. BREAKER

T =70.57 amp.
DESIGNED BY: PRC NO. REPUBLIC ACT 9266 ( SECTION 33) PROJECT TITLE APPROVED BY: SHEET CONTENT SHEET NO.
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS
VALIDITY:
EL
SIGNED AND SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT,
PTR NO. WHETHER THE OBJECT FOR WHICH THEY ARE MADE ARE EXECUTED OR PROPOSED TWO-STOREY AS SHOWN
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR MAKE
DATE ISSUED: COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR RESIDENTIAL BUILDING MR. TYRONE H. BUCK
OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN

PROFESSIONAL ELECTRICAL ENGINEER


PLACE ISSUED:
TIN :
WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF
SAID DOCUMENTS.
CADD & RENDERED BY:
LOCATION : BRGY. RIZAL, SANTIAGO CITY OWNER 2

You might also like