The document outlines 10 questions that will be included on a written test for DCRP covering various topics relating to substation protection systems. The questions cover details of 11kV current and potential transformers, testing procedures for current transformers, composite errors in current transformers, the purpose of terminal blocks and supervision relays, the sequence of operation of an auto-reclosure system, the working principle of a trip circuit supervision circuit, overcurrent and earth fault relay characteristics and timing formulas, calculating primary currents from secondary currents in relays, and setting input details for various overcurrent and earth fault relays. The test will be worth a total of 70 points.
The document outlines 10 questions that will be included on a written test for DCRP covering various topics relating to substation protection systems. The questions cover details of 11kV current and potential transformers, testing procedures for current transformers, composite errors in current transformers, the purpose of terminal blocks and supervision relays, the sequence of operation of an auto-reclosure system, the working principle of a trip circuit supervision circuit, overcurrent and earth fault relay characteristics and timing formulas, calculating primary currents from secondary currents in relays, and setting input details for various overcurrent and earth fault relays. The test will be worth a total of 70 points.
The document outlines 10 questions that will be included on a written test for DCRP covering various topics relating to substation protection systems. The questions cover details of 11kV current and potential transformers, testing procedures for current transformers, composite errors in current transformers, the purpose of terminal blocks and supervision relays, the sequence of operation of an auto-reclosure system, the working principle of a trip circuit supervision circuit, overcurrent and earth fault relay characteristics and timing formulas, calculating primary currents from secondary currents in relays, and setting input details for various overcurrent and earth fault relays. The test will be worth a total of 70 points.
1. 11KV CT DETAILS OF PROTECTION AND METERING CORES (5 PTS)
2. 11KV PT DETAILS OF PROTECTION AND METERING CORES (5 PTS) 3. POLARITY TEST PROCEDURE & RESULT FOR CT (5 PTS) 4. COMPSITE ERROR IN CT (5 PTS) 5. PURPOSE OF TERMINAL BLOCK, DC SUPERVISION RELAY, AC SUPERVISION RELAY, SWITCH, LINKS, RELAY OUTPUTS (6 PTS) 6. SEQUENCE OF OPERATION OF AUTO RECLOSURE SYSTEM. (5PTS) 7. WORKING PRINCIPLE OF TRIP CIRCUIT SUPERVISION CIRCUIT (4 PTS) 8. OC RELAY IDMT, DMT CHARACTERISTICS CURVE WITH TIMING FORMULA (10 PTS) 9. OC& EF RELAY (20 PTS) I. FOR GIVEN SECONDARY CURRENT, CORRESPONDING PRIMARY CURRENT SHOULD BE CALCULATED IN RELAY II. TIME CALCULATION FOR NORMAL INVERSE CURVE FOR 2 TIMES FAULT FOR OC AND 5 TIMES FAULT FOR EF 10. RELAY SETTING INPUT DETAILS FOR 51/50/50N (5 PTS)