Hardened Concrete Properties

Splitting Tensile Strength (0.4 W/C Ratio, 125lb/sec rate of Load) (ASTM C 496)

Specimen Length Diameter Weight Ultimate Rate of Tensile


ID (in) (in) (lb) Load Load Strength
[L] [D] [W] (lbf) (lb/sec) (psi)
[P] [R] [T]
1 8 4 8.77 30550 300
2 8 4 8.63 23760 310
3 8 4 8.62 23060 380
Mean
Standard Dev.
Coeff. of Var.

Compressive Strength (0.4 W/C Ratio, 500lb/sec rate of Load) (ASTM C 39)

Specimen Diameter Area Weight Ultimate Rate of Compressive


ID (in) (in2) (lb) Load Load Strength
[D] [A] [W] (lbf) (lb/sec) (psi)
[P] [R] [fc’]
1 4 12.57 8.65 61590 430
2 4 12.57 8.65 38640 230
3 4 12.57 8.65 57580 320
Mean
Standard Dev.
Coeff. of Var.

Compressive Strength (0.4 W/C Ratio, 1000lb/sec rate of Load) (ASTM C 39)

Specimen Diameter Area Weight Ultimate Rate of Compressive


ID (in) (in2) (lb) Load Load Strength
[D] [A] [W] (lbf) (lb/sec) (psi)
[P] [R] [fc’]
1 4 12.57 8.58 71810 950
2 4 12.57 8.63 53160 610
3 4 12.57 8.56 51640 730
Mean
Standard Dev.
Coeff. of Var.
Compressive Strength (0.7 W/C Ratio, 1000lb/sec rate of Load) (ASTM C 39)

Specimen Diameter Area Weight Ultimate Rate of Compressive


ID (in) (in2) (lb) Load Load Strength
[D] [A] [W] (lbf) (lb/sec) (psi)
[P] [R] [fc’]
1 4 12.57 8.47 59190 1160
2 4 12.57 8.55 56930 950
3 4 12.57 8.63 49200 760
Mean
Standard Dev.
Coeff. of Var.

Compressive Strength (0.7 W/C Ratio, 1000lb/sec rate of


Load) (ASTM C 39)

Specimen Diameter Area Ultimate Compressive


ID (in) (in2) Load Strength
[D] [A] (lbf) (psi)
[P] [fc’]
1 6 28.27 136710
2 6 28.27 160390
Mean
Standard Dev.
Coeff. of Var.