Professional Documents
Culture Documents
Atrtsmy60 Annex2
Atrtsmy60 Annex2
ANNEX 2
ANNEX 2
Printed in France
TROUBLE SHOOTING MANUAL
CAUTION: If you have any doubts in the elimination of the fault, refer to the
corresponding fault isolation procedure before releasing the aircraft.
NOTE: For TSM in electronic format you can use the search function.
This Annex 2 does not cover all the messages/faults that may be detected on the
aircraft.
If the message/fault is not given in the Annex 2, refer to the FAULT SYMPTOMS
paragraph then to the corresponding FAULT ISOLATION procedure.
Table 1 gives the functional designation and location of each circuit breaker or
pushbutton switch used in Table 2.
- “If the alert persists, perform”: Provides the ATA/Chapter (thru a link)
where the fault isolation procedure corresponding to the Fault Symptom is
described.
If you have any doubts in the elimination of the fault, refer to the
corresponding fault isolation procedure before releasing the aircraft.
General information
The Annex 2 must be used only with the aircraft on the ground and in maintenance
status (Refer to the introduction of this manual).
ANNEX 2
Page 1
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
CIRCUIT
DESIGNATION LOCATION
BREAKER
24FL PRIM REF/ADC2/ICP F/O GND SPLY 21VU
2FP1 ATT/HDG/AHRS1 AUX SPLY 21VU
2SG SUR/T2CAS/T-R 21VU
3FL1 PRIM REF/ADC1/ICP CAPT EMER SPLY 21VU
3FP1 ATT/HDG/AHRS1 NORM SPLY 21VU
3FP2 ATT/HDG/AHRS2 NORM SPLY 21VU
3SA1 NAV/COM/SUR/RA1 21VU
3SA2 NAV/COM/SUR/RA2 21VU
3SD1 NAV/COM/SURV/DME1 21VU
3SD2 NAV/COM/SURV/DME2 21VU
3TF1 CAC/CPM1/IOM-S1 21VU
3TF2 CAC/CPM2/IOM-S2 NORM SPLY 21VU
4RB COM/ACARS CMU 21VU
4RC1 NAV/COM/SURV/VHF1 21VU
4RC2 NAV/COM/SURV/VHF2 21VU
4RE1 HF1/T-R 127VU
4RE2 HF2/T-R 129VU
4SH1 NAV/COM/ATC1 21VU
4SH2 NAV/COM/ATC2 21VU
4TF1 CAC/IOM-DC/12 21VU
4TF2 CAC/IOM-DC/22 21VU
4UA1 MFC/1A AUX/ADC1 HOT SPLY 21VU
6FP ATT/HDG/AHRS2 AUX SPLY-GND 21VU
6TF1 CAC/IOM-DC/13 21VU
6TF2 CAC/IOM-DC/23 21VU
Table 1
ANNEX 2
Page 2
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
Open during 5 sec. then
close C/B 4UA1 and 3FL1
to reset ADC1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/ADC1.
MC ADC ONE ADC FAIL TSM 34-10
Open during 5 sec. then
close C/B 24FL to reset
ADC2.
Perform a system test.
On MCDU go to
ACMS/AVS/CMS//”SYSTEM
REPORT/TEST”/ADC2.
Table 2
ANNEX 2
Page 3
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
Parking brake engaged,
open during 5 sec. then
close C/B 3FP1, 2FP1,
6FP and 3FP2.
NOTE: the aircraft must
be stabilized on ground
during at least one
MC AHRS NOT ALIGN AHRS NOT ALIGN minute before to TSM 34-25
perform the system
test.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/AHRS1 then
AHRS2.
Open during 5 sec. then
close C/B 4UA1, 3FL1
and 24FL.
Perform a system test.
MC ALT DISAGREE ALTITUDE DISAGREE TSM 34-11
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/ADC1 then
ADC2.
Open during 5 sec. then
close C/B 3FP1, 2FP1,
6FP and 3FP2.
Perform a system test.
MC ATT DISAGREE ATTITUDE DISAGREE TSM 34-25
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/AHRS1 then
AHRS2.
Parking brake or Gust
lock engaged and
engines 1 and 2 off.
Open during 5 sec. then
close C/B 3TF1 to reset
MC AVNX CPM1 AVNX CPM 1 LOSS TSM 42-11
CPM1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/CAC1/CPM1.
Table 2 (continued)
ANNEX 2
Page 4
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
Parking brake or Gust
lock engaged and
engines 1 and 2 off.
Open during 5 sec. then
AVNX CPM 1 + IOM 22 close C/B 3TF1 to reset
MC AVNX CPM1+IOM22 TSM 42-11
LOSS CPM1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/CAC1/CPM1.
Parking brake or Gust
lock engaged and
engines 1 and 2 off.
Open during 5 sec. then
AVNX CPM 1 + IOM 23 close C/B 3TF1 to reset
MC AVNX CPM1+IOM23 TSM 42-11
LOSS CPM1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/CAC1/CPM1.
Parking brake or Gust
lock engaged and
engines 1 and 2 off.
Open during 5 sec. then
close C/B 3TF2 to reset
MC AVNX CPM2 AVNX CPM 2 LOSS TSM 42-11
CPM2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/CAC2/CPM2.
Parking brake or Gust
lock engaged and
engines 1 and 2 off.
Open during 5 sec. then
AVNX CPM 2 + IOM 12 close C/B 3TF2 to reset
MC AVNX CPM2+IOM12 TSM 42-11
LOSS CPM2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/CAC2/CPM2.
Table 2 (continued)
ANNEX 2
Page 5
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
Parking brake or Gust
lock engaged and
engines 1 and 2 off.
Open during 5 sec. then
AVNX CPM 2 + IOM 13 close C/B 3TF2 to reset
MC AVNX CPM2+IOM13 TSM 42-11
LOSS CPM2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/CAC2/CPM2.
Table 2 (continued)
ANNEX 2
Page 6
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
Parking brake or Gust
lock engaged and
engines 1 and 2 off.
Open during 5 sec. then
close C/B 5TF1.
Perform a system test.
On MCDU go to
MC AVNX SGL SWITCH AVNX SGL SWITCH ACMS/AVS/”SYSTEM TSM 42-11
REPORT/TEST”/SWM1.
Open during 5 sec. then
close C/B 5TF2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/SWM2.
Switch off during
MC BAD CONF - 5 sec. then switch on TSM 31-63
the DU1 and DU5.
Open during 5 sec. then
close C/B 4RB.
DATALINK
Perform a system test.
MC Post mod. 05959 - TSM 23-24
On MCDU go to
only
ACMS/AVS/”SYSTEM
REPORT/TEST”/CMU.
Open during 5 sec. then
close C/B 3SD1 to reset
DME1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/DME1.
MC DME LOSS - TSM 34-51
Open during 5 sec. then
close C/B 3SD2 to reset
DME2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/DME2.
Make sure that parking
brake is "ON" (or Gust
lock engaged) and
engines 1 and 2 off.
MC FWS SGL CH AVNX FWS SGL CH Open during 5 sec. then TSM 42-11
close C/B 3TF1 to reset
CPM1.
Open during 5 sec. then
close C/B 3TF2 to reset
CPM2.
Table 2 (continued)
ANNEX 2
Page 7
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
Open C/B 2SG during
5 sec. then close it to
reset computer T2CAS.
Perform a system test.
MC GPWS None TSM 34-48
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/XPDR1/
T2CAS.
Open during 5 sec. then
close C/B 3FP1, 2FP1,
6FP and 3FP2.
Perform a system test.
MC HDG DISAGREE HEADING DISAGREE TSM 34-25
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/AHRS1 then
AHRS2.
Open during 5 sec. then
close C/B 4RE1 to reset
HF1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/HF1.
MC HF None TSM 23-11
Open during 5 sec. then
close C/B 4RE2 to reset
HF2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/HF2.
Table 2 (continued)
ANNEX 2
Page 8
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
Open during 5 sec. then
close C/B 3FL1 and 24FL
Perform a system test.
MC IAS DISAGREE IAS DISAGREE On MCDU go to TSM 34-11
ACMS/AVS/”SYSTEM
REPORT/TEST”/ADC1 then
ADC2.
On panel 25VU, depress
the pushbuttons 7UA1,
6UA1 and 6UA2, wait
MC MFC 1A MFC 1A FAULT 5 sec. then press 6UA1 TSM 31-48
and 6UA2 and when they
stop to flash, press
7UA1.
On panel 25VU, depress
the pushbuttons 7UA1,
6UA1 and 6UA2, wait
MC MFC 1A + 1B MFC 1A + 1B FAULT 5 sec. then press 6UA2 TSM 31-48
and when it stop to
flash, press 7UA1 and
6UA1.
On panel 25VU, depress
the pushbuttons 7UA1,
7UA2, 6UA1 and 6UA2,
MC MFC 1A + 2A MFC 1A + 2A FAULT wait 5 sec. then press TSM 31-48
6UA1 and 6UA2 and when
they stop to flash,
press 7UA1 and 7UA2.
On panel 25VU, depress
the pushbuttons 7UA1,
6UA2 and 6UA1, wait
MC MFC 1A + 2B MFC 1A + 2B FAULT 5 sec. then press 6UA1 TSM 31-48
and when it stop to
flash, press 7UA1 and
6UA2.
On panel 25VU, depress
the pushbuttons 6UA1
and 6UA2, wait 5 sec.
MC MFC 1B MFC 1B FAULT TSM 31-48
then press 6UA2 and
when it stop to flash,
press 6UA1.
On panel 25VU, depress
the pushbuttons 6UA1,
7UA2, 6UA2, wait 5 sec.
MC MFC 1B + 2A MFC 1B + 2A FAULT TSM 31-48
then press 6UA2 and
when it stop to flash,
press 6UA1 and 7UA2.
Table 2 (continued)
ANNEX 2
Page 9
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
On panel 25VU, depress
the pushbuttons 6UA1,
6UA2, 7UA1and 7UA2,
MC MFC 1B + 2B MFC 1B + 2B FAULT wait 5 sec. then press TSM 31-48
7UA1 and 7UA2 and when
they stop to flash,
press 6UA1 and 6UA2.
On panel 25VU, depress
the pushbuttons 7UA2,
6UA1 and 6UA2, wait
MC MFC 2A MFC 2A FAULT 5 sec. then press 6UA1 TSM 31-48
and 6UA2 and when they
stop to flash, press
7UA2.
On panel 25VU, depress
the pushbuttons 7UA2,
6UA2 and 6UA1, wait
MC MFC 2A + 2B MFC 2A + 2B FAULT 5 sec. then press 6UA1 TSM 31-48
and when it stop to
flash, press 7UA2 and
6UA2.
On panel 25VU, depress
the pushbuttons 6UA2
and 6UA1, wait 5 sec.
MC MFC 2B MFC 2B FAULT TSM 31-48
then press 6UA1 and
when it stop to flash,
press 6UA2.
Open during 5 sec. then
close C/B 3SA1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/RA1.
RAD-ALT
If mod. 05967 is
MC Post mod. 05967 ONE RAD-ALT FAIL TSM 34-42
installed, open during
only
5 sec. then close C/B
3SA2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/RA2.
Table 2 (continued)
ANNEX 2
Page 10
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
Open during 5 sec. then
close C/B 3SA1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/RA1.
If mod. 05967 is
MC RAD-ALT LOSS RAD-ALT LOSS TSM 34-42
installed, open during
5 sec. then close C/B
3SA2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/RA2.
Switch off DU2 during
5 sec. then switch on
DU2.
On MCDU go to
ACMS/AVS/CMS//SYSTEM
REPORT/TEST/DU2.
Switch off DU4 during
5 sec. then switch on
MC RMS None TSM 31-63
DU4.
On MCDU go to
ACMS/AVS/CMS//SYSTEM
REPORT/TEST/DU4.
NOTE: when DU2 or DU4
is switched off, RMS
1+2 can be displayed on
EWD alert window.
Table 2 (continued)
ANNEX 2
Page 11
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
Open during 5 sec. then
close C/B 2SG to reset
computer T2CAS.
Perform a system test.
MC TCAS None TSM 34-43
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/XPDR1/
T2CAS.
Open during 5 sec. then
close C/B 2SG to reset
computer T2CAS.
Perform a system test.
MC TERRAIN None TSM 34-48
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/XPDR1/
T2CAS.
Open during 5 sec. then
close C/B 4RC1 to reset
VHF1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/VHF1.
MC VHF None TSM 23-12
Open during 5 sec. then
close C/B 4RC2 to reset
VHF2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/VHF2.
Table 2 (continued)
ANNEX 2
Page 12
APR 01/14
Printed in France
TROUBLE SHOOTING MANUAL
If the
MW Warning or
alert
or caution message ALERT DESCRIPTION Maintenance action
persists,
MC displayed on EWD
perform:
Open during 5 sec. then
close C/B 4SH1 to reset
XPDR1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/XPDR1/
T2CAS.
MC XPDR None TSM 34-52
Open during 5 sec. then
close C/B 4SH2 to reset
XPDR2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM
REPORT/TEST”/XPDR2/
T2CAS.
If the
alert
EQUIPMENT FAULT DESCRIPTION Maintenance action
persist,
perform:
Open during 5 sec. then
close C/B 1MW and 3MW
Flight attendant or press the reset
Panel frozen TBD
panel (FIN10MW) pushbutton located on
the front face of the
FAP to reset it.
Table 2 (continued)
ANNEX 2
Page 13
APR 01/14
Printed in France