PSURGE 4010

Combination Wave Surge Generator

Surge voltage transients


are caused by switching
and lightning effects. The
PSURGE 4010 allows
evaluation of the
performance of equipment
when subject to high-
energy disturbances on
power and interconnection
lines.

PSURGE 4010 - the compact IEC combination wave generator

ONE SOLUTION FOR


 IEC / EN 61000-4-5 Edition 1 & 2
 EN 61000-6-1
 EN 61000-6-2 Combination wave detail (front) and
impulse on AC power frequency (rear)

FEATURES BENEFITS
 Combination wave  Totally reproducible test results
Voltage: 1,2/50us  Consistent pulse parameters
Current: 8/20us  Fully automatic execution of
 Impulse voltage: 200V ... 4.2kV complex test routines and
 Impulse current: 100A ... 2,1kA sequences
 Maximum impulse repetition rate 12  Cost effective solution
per minute  Expandable to 3 phase testing
 Positive, negative and user definable with FP-SURGE 32.1
alternating polarity  Expandable to impulse magnetic
 Integrated CDN for 16A at 264Vac and field testing (IEC 61000-4-9) with
110Vdc MSURGE
 Impulse voltage, current and EUT
current measurement
 Test parameter ramp functions
 Phase angle synchronization
 18 test and 18 program memory
locations
 Remote control using WinFEAT&R©
CONTROL
CONTROL QUALITY EFFICIENT
ENHANCING TESTING
The internal microprocessor, High flexibility and
and intelligent user interface The PSURGE 4010 operation of tests is
making use of main function generator is fully compliant achieved through:
hard-keys, makes this to the IEC requirements.  Fully automatic test
device very user friendly. A solid state high voltage sequences
The following points further switch provides very  EUT failure detection
increase user flexibility : accurate reproducible tests, and protection by
 Programmable and long life expectancy and programmable current
variable parameters accurate phase limits
make PSURGE 4010 synchronisation. Product  EUT failure detection
ideal for development quality is enhanced by: with integrated “EUT
and quality engineers.  An integrated current Failed” input
 Permanent storage of protected coupling- connector
tests and programs decoupling network  Centronix interface for
 Alphanumeric input  decoupling inductors that printer
 Multi-mode LCD display maintain the impulse  A serial RS-232
 Test report generated waveform interface enable
directly to a printer  Integrated high operation from a
without using an performance peak computer
external computer measurements of  Expansion into an
 Easy remote control impulse voltage and automatic 3-phase
programming with an current system
external computer and  Safety circuit and  Possibility to fulfil IEC
WinFEAT&R software emergency stop circuit 61000-4-9 with an
provide high personnel optional coil antenna
protection

TECHNICAL SPECIFICATION
SPECIFICATION
Waveshape 1,2/50us and 8/20us
according to IEC 61000-4-5 Internal single-phase CDN
Impulse Voltage 200V ... 4,2kV • max. AC power 264V / 16A, 50-60Hz
on Schuko plug
Impulse Current 100A ... 2,1kA • max. DC power 110V / 16A
Impulse Repetition Up to 12 per minute • Coupling mode 18uF and 9uF+10Ω
acc. to IEC 61000-4-5
Impulse Polarity Positive, Negative, Alternating Size 19" / 3 units
Power supply 85V ... 264V, 50/60Hz Weight 18 kg

ORDERING INFORMATION
PSURGE 4010 249600
MSURGE coil antenna 249559
Stand for coil antenna 249003
FP-SURGE 32.1 3-phase CDN 249944
WinFEAT&R software 249970

Headquarters Locate your local North American Office


Haefely Test AG sales representative at Hipotronics Inc.
Lehenmattstrasse 353 www.haefelyEMC.com Haefely EMC Division
CH-4052, Basel 1650 Route 22
Switzerland Brewster, NY 10509

 + 41 61 373 41 11  ++1 845 279 3644 x262


 + 41 61 373 45 99  ++1 845 279 2467
 EMC-sales@haefely.com  EMCsales@hubbell-haefely.com