ASME Code Section VIII Div.

1 exemption rules for ASME Impact Test Requirements:

You need to follow the following clauses to make exemption assessment for ASME
impact test requirement:

UG-20(f) →→ UCS-66(A) →→ UCS-66(b) →→→UCS-68(c)

First, you have to keep your pressure vessel design data available and then refer to UG-
20 (f). If you are exempted from this clause, you do not need to proceed further.

But if you are not exempted by UG-20 (f), you have to proceed to UCS-66(a), but again if
you are exempted, there is no need for more assessment.

But if not, you have to proceed to UCS-66(b). If you are exempt now, there is no need
for more assessment; otherwise, you have to proceed to UCS-68(c), and again if you are
still not exempt, you have to carry out impact testing.

In some cases, you might be exempted from the ASME impact test requirement in the
first stage of UG-20 (f). In others, you may be exempted from UCS-66(a) or UCS-66(b) or
UCS-68(c). If you are not exempted, you must prepare yourself for doing this costly
test.

UG-20(f)

We will start with UG-20(f) for the ASME impact test requirement. If your MOC
(Material of Construction) is categorized in P-No. 1 or 2 (Refer to ASME Code Section IX
for P-No Definition) and your MOC thickness has the limited value defined in this
clause (<=13 mm for material Listed in Curve A and <=25 mm for material Listed in
Curve B , then you might be exempted from impact testing.

But you need to refer to Fig UCS-66 in ASME Code Section VIII Div 1 and see in which
A, B, C or D curves your MOC is listed. All ASME carbon steel and low alloy steel
material is distributed in these 4 groups (Curves) of materials.

You need to know that the materials listed in curve D have the best toughness property,
better than the materials listed in curve C. Similarly materials listed in curve C have
better toughness properties compared to materials listed in curve B and materials
listed in Curve B have better toughness than materials listed in Curve A 

See Following Fig UCS-66(a) :


When you determine your MOC curve, then you have to review UG-20(f) and look for
the possibility of exemption from the ASME impact test requirement. There are some
other conditions in this clause, which you should consider for exemption.

For instance, the vessel should be hydrostatically tested after completion, and the
thermal and mechanical loading can not be a design controlling factor.

For example, if your MOC is a normalized SA 516 Gr.70 with 0.75 inch thickness you
will be exempted from ASME impact test requirements.

Your thickness, in this example, is 0.75 of an inch, and is listed in curve D which is up
to 1 inch, you are exempted by this clause. Of course, you will be carry out hydro-static
test and ensure that the mentioned loadings are not a design controlling factor in your
considered pressure vessel.

UCS-66(a)

So assume that in the above example, your MOC thickness is 1.125 inch instead of 1
inch, you will not be exempted by UG-20(f) and you have to refer to UCS-66(a);
But for assessment, based on this clause, you need to know your pressure vessel
MDMT (Minimum Design Metal Temperature). Assume that is -20 degree F, so you
should now go to Fig. UCS-66 and locate 1.125 inch in the horizontal axis and draw a
vertical line.

In a similar way, locate -20 degree F in the vertical axes and draw a horizontal line.
These two lines will cross each other.

See above Figure. The lines are identified in red.

If the cross point falls above the curve D (because your MOC is listed in curve D) you
are exempted. Otherwise you are not, but for the current example, you are above the
curve D so you are exempted from impact testing.

To simplify your assessment for the ASME impact test requirement, the Fig-66 has
been converted to the table (table UCS-66). For any MOC with specific thickness you
can go to this table and see what is the minimum permissible temperature without
impact testing.

See following UCS-66(a) Table:


 

In the above example (normalized SA 516 Gr.70, Curve D, 1.125 inch thickness), the
minimum permissible temperature without impact test is -26 degree F. This means
that, if in the above example your MDMT changes from -20 degree F to -27 degree F,
then you cannot be exempted from the ASME impact test requirement by UCS-66(a),
and you have to proceed to UCS-66(b).

UCS-66(b)

Let us explain this clause with the above example. Your MDMT from above is -27
degree F, nominal thickness is 1.125 inch, normalized SA 516 Gr.70 listed in curve D
and you are not exempted by UCS-66(a)

So you are here to continue your assessment to find a chance for exemption. You have
to refer to Fig UCS-66.1 and calculate the following formula:

Ratio= tr E / (tn –c)

tr is the required design thickness for all applicable loading. We assume for the above
example that is 0.95 inch. E is your joint efficiency, and we assume for this vessel it is 1.
This means your vessel is RT2, tn is your nominal thinness, which in the example from
above it is 1.125 inches, and C is your corrosion allowance, and we assume it is 0.125
inches; so let us calculate:

Ratio = 0.95×1/(1.125 – 0.125) Ratio= 0.95

See following Fig UCS-66(b):

Then go to Figure UCS-66(b) and in the vertical axes locate Ratio and draw a horizontal
line. Then locate the cross point with the graph and draw a vertical line to cross the
horizontal axis.

You will be able to reach a value of 8 in the horizontal axes. This 8, is your 8 degree F
bonus from table UCS-66, which you can reduce by 8 degrees F minimum permissible
temperature in table without impact testing.

In the above example, your MDMT is -27 degree F, and in the UCS 66 table, the
minimum permissible temperature without impact testing is -26 degree F. So with this
clause you can reduce it to -36 degree F(-26 -8 = -34). Your MDMT is -27 degree F, so you
are exempted from impact testing with this clause.
UCS-68(c)

Let us change one variable in the above example. Let’s assume you need to have -45
degree F for your MDMT. Other variables are the same; it means normalized SA 516
Gr.70 listed in curve D, thickness 1.125, so you can see you are not exempted by UCS-
66(b);

This is because the minimum permissible temperature is -36 degree F, but your MDMT
is -45 degree F, so UCS-68(c) might be helpful.

It says that if post weld heat treatment is not a code requirement and your P-No is 1 and
you carry out post weld heat treatment, a 30 degree F bonus will be granted to you to
reduce the minimum permissible temperature in table UCS-66.

So what post weld heat treatment is the code requirement?

It is code requirement when your service is lethal and when your thickness for P-No. 1
is greater than 1.5 inches;

So, for example, our service is not lethal and our P-No.1 thickness is 1.125 and it is less
than 1.5 inches: therefore, post-weld heat treatment is not a code requirement.

It means if you carry out post-heat treatment, a 30 degree F bonus will be granted by
this clause. For example, our minimum permissible temperature would be -36-30=-66
degree F, and your MDMT is -45 degree F, so you are exempted from impact testing.

Now the worst case: in the above, assume you need to have -70 degree F for your
MDMT; you can see with this new condition you cannot be exempted even by UCS-
68(c) and you have to carry out impact testing.