COMMANDER-SE PARAMETERS

For lift aplication all the prameters of Commander SE is setted in fabric. Only few
parameters listed here must be adjusted by user according to travel curve and motor.

Parametre No Fabrika değeri Fonksiyon


03 = 3.5 sn : Acceleration Time
04 = 3.2 sn : Decceleration Time
06 =? : Motor plate current
07 = 1430 rpm : Motor nominal rpm
08 = 380 V : Motor nominal voltage
09 = 0.75 : Motor cos ∂
10 = L2 : To set all parameters accessible
11 =0
12 = 50 Hz : High Speed
13 = 7 Hz : Low Speed
14 = 15 Hz : Inspection Speed

For the first time running the motor:

48 =3 : When parameter 48 set to 3. Vvvf test motor and learn


it. On the display while testing TUNE is writen. If you
give move comment by insection buttons , hold
inspection buton till the Auto Tune finish.

You might also like