Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

HMK12AA

PRODUCT SPECIFICATION

OPERATION:

Application: L.B.P. Max. Ambient Temp: 43°C


Refrigerant: R600a
(1) Max. Steady Discharge Temp: 120°C
Operation: Capillary (1,2) Max. Peak Discharge Temp: 135°C
Cooling: Static Max. Steady Condensing Temp: 60°C
(2) Max. Peak Condensing Temp: 70°C
Max. Winding Temp: 130°C

Max. Impurities: 30 mg
Max.Total Compressor Water Content: 100 mg

COMPRESSOR:

Displacement: 11.2 cc Oil Type: Mineral


Bore: 25.40 mm (4) Viscosity: 10 cSt
Stroke: 22.00 mm Suction Muffler: Semi-direct

(3) Net Wt: 8.5 kg


Case Size: h = 165,5 mm h
Oil Charge: 170 cc

ELECTRICAL:

Power Supply: 220 - 240V Motor Type: RSIR


Voltage Limits: 187 - 264V
Frequency: 50 Hz Locked Rotor Current: 13.3 / 6.8 A**
Phase: 1 ph

Main Winding Resistance at 25°C: 14.4 Ω


Start Winding Resistance at 25°C: 20.3 Ω

** Maximum current / Measured after 4 seconds


For rated performance,
(1) Measured 5cm. from the shell with insulated thermocouples the suction line must be connected to the stub
(2) For transient conditions during 'Pull Down' marked 'AS' on the attached drawing.
(3) Net weight is with oil but without electrics
(4) Measured at 40°C

AE 13106.0 Feb '07 Page 1 ACC reserves the right to change the data without prior notice
HMK12AA
PRODUCT SPECIFICATION

ELECTRICAL COMPONENTS:

Starting Device: K 100-xx -xx Protector short code


(1) Starting Device: PTC- 7100DT / 8100
PTC Resistance: 14 Ω

PROTECTORS:

PROTECTORS BDG ¾ Tongbao SENSATA 4TM


Type AE 72 FU x BT86 120xx 4TM 293 NFBYY xx
Open °C 115 - 125 °C 115 - 125 °C 115 - 125 °C
Close °C 71 - 53 °C 71 - 53 °C 70 - 52 °C
U.T.C 2.1 A 70 °C 2.1 A 70 °C 2.15 A 70 °C
Time Check Current 8.6 A 8.6 A 10.0 A (5-15s)
Max. Current 17.0 A 17.0 A 21.6 A (2s max.)
Code (if any) FP L1 6L

Alt. protectors: AF 72 FU x
DT

PTC-71.. / 81.. are for Terminal Cover version only.


(1) BDG protector AF type is for use with PTC-71.. only, and PTC-71.. is only fitted with BDG protector.

AE 13106.0 Feb '07 Page 2 ACC reserves the right to change the data without prior notice
HMK12AA
PRODUCT SPECIFICATION
PERFORMANCE: (Graphs are at ASHRAE conditions) 220V 50Hz
1,15
Amps
1,10 60°C COND.
1,05 55°C TEMP.
1,00 50°C
0,95 45°C
0,90 40°C
0,85
0,80
Input 210
Watts 190
60°C COND.
170 55°C TEMP.
150 50°C
130 45°C

110 40°C

90
C.o.P.
2,70
40°C TEMP.
2,50
45°C TEMP.
2,30 50°C
2,10 55°C
1,90 60°C
1,70
1,50
1,30
1,10

380
Capacity
360 40°C COND.
WATT 45°C TEMP.
340
50°C
320
55°C
300
60°C
280
260
240
220
200
Test Conditions: ASHRAE CECOMAF
180 Condensing Temp: 55°C 55°C
160 Liquid Temp: 32°C 55°C
Gas Return Temp: 32°C 32°C
140 Ambient Temp: 32°C 32°C
120
-35 -30 -25 -20 -15 -10 -5
Evaporating Temperature (°C)

Evaporating Temperature °C -30 -25 -23,3 -20 -15 -10


ASHRAE: Capacity W 137 181 198 233 291 355
C.o.P. W/W 1,28 1,47 1,53 1,65 1,84 2,02

CECOMAF: Capacity W 113 149 192 239 292


C.o.P. W/W 1,06 1,20 1,36 1,51 1,66

Input Power W 107 124 129 141 158 176


Current A 0,84 0,89 0,91 0,95 1,01 1,07

AE 13106.0 Feb '07 Page 3 ACC reserves the right to change the data without prior notice
HMK12AA
PRODUCT SPECIFICATION

Circuit Diagram for Terminal Board Standard Version


Mounting Accessories
Appliance,
Lights etc. 2

Motor Thermostat
Protector y 1

E x
L 5 4
3
PTC
N
y 1

5th S
Optional x
NL
Run Capacitor
x = 26mm or 28.5mm
where applicable
y = 9mm or 10.3mm
Other sizes available
Circuit Diagram for Terminal Board Frontal Version 1. Rubber grommet
2. Sleeve
Appliance, 3. Washer
Lights etc. 4. Steel pin
5. Clip
Motor Thermostat
Protector
1

E
L
Recommended Transport
PTC Positions when fitted into
N
appliances

5th S
Optional NL
Run Capacitor
where applicable
Upright

Circuit Diagram for Terminal Board Rast 5 Version

Appliance,
Lights etc. Tubes Down
Motor Thermostat
Protector Compressor Label
1

E Production Electrical
L Logo Model
Date Characteristics
PTC
N

S Refrigerant
5th
Optional SUCTION>
NL
Run Capacitor
where applicable
Bar Code Check
Digit

Manufacturer Version Serial Approvals


Number
AE 13106.0 Feb '07 Page 4 ACC reserves the right to change the data without prior notice

You might also like