Professional Documents
Culture Documents
TL 5903 Fev F 0420
TL 5903 Fev F 0420
TECHNICAL DATA
(Typical values @+ 25ºC for batteries stored for one year or less)
◼ Nominal capacity 2.4 Ah
◼ Rated voltage 3.6 V
◼ Maximum recommended continuous current 100 mA
◼ Maximum pulse current capability 200 mA
◼ Weight 18 g (0.635 oz)
◼ Volume 8 cc
◼ Operating temperature range -55 ºC to +85 ºC
◼ Li metal content approx. 0.65 g
◼ IEC 60086-4 certified
U.L. Component Recognition, MH 12193
Volts DISCHARGE CHARACTERISTICS @ +25ºC
4.0
3.5
3.0
2.5
2.0
100 W 680 W 1.8 kW 12 kW 40 kW 147 kW
~31 mA ~5 mA ~2 mA ~0.3 mA ~90 mA ~25 mA
(1.70 Ah) (2.17 Ah) (2.20 Ah) (2.17 Ah) (2.12 Ah) (1.90 Ah)
1.5 TERMINATIONS & ORDERING NO.
2.9 55 °C
1.0
10 mA 72 °C
2.7 0.7
31 mA
2.5 0.4
-50 -30 -10 10 30 50 70 90 0.01 0.1 1 10
ºC mA
Page 1 of 2
TL-5903
CELL FEATURES
◼ 3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
◼ Fast voltage recovery after long term storage and/or usage
◼ High energy density
◼ High and stable operating voltage
◼ Low self discharge rate MAIN APPLICATIONS
◼ Bobbin construction
◼ Hermetic glass-to-metal-sealing ◼ Utility meters (elect., water &
◼ Non-flammable electrolyte gas)
◼ Automatic meter reading
◼ RF systems
◼ Sensors & monitoring systems
Volts
◼ Tracking systems
VOLTAGE RESPONSE AFTER STORAGE
3.5 ◼ Wireless security systems
After 1 year
After 2 years
◼ Automotive electronics
3.4
◼ Industrial electronics
After 5 years
3.3 ◼ Ultra Low Power (ULP)
After 10 years
3.2 devices
◼ Others
3.1 STORAGE CONDITIONS
3.0 ◼ Cells should be stored in a
2.9 clean & dry (less than 30 %
Pulse applied: 20 mA for 1 sec RH) area
2.8 Storage: RT
Background current: None ◼ Temp. should not exceed +30
2.7 ºC
2.6
For updated information please visit
0 200 400 600 800 1000 1200
our website www.tadiranbat.com
ms ec
3.2 Pulse applied: 20 mA for 100 msec 3.2 Pulse applied: 20 mA for 100 msec
Temperature: RT Temperature: RT
Background current: 10 mA Background current: 20 mA
3.1 3.1
0 20 40 60 80 100 120 0 20 40 60 80 100 120
ms ec ms ec
Page 2 of 2