Download as pdf
Download as pdf
You are on page 1of 15
@ERA Reference Materials ‘A Waters Company = Certificate of Analysis « Product: Wath Polution Simple Nutrients Catalog Number: 505 Lot No. P273-505 ete ins enn ne bares sper of Certificate Issue Date: December 21, 2017 ‘separately from this Certificate of Analysis. Please Expiration Date: January 31, 2021 Telcordia ase sen nice -O Revision Number: Original CERTIFICATION Certified QC Performance PT Performance Parameter Value’ Uncertainty? Acceptance Limits? Acceptance Limits* mot * mot mt Ammonia as N 12.0 0.422 10.3 - 13.7 9.59- 14.3 Nitrate + Nitrite as N 15 142 102-128 957-133 Nitrate as N 115 142 101-128 953-134 ortho-Phosphate as P 236 0.420 2it-262 201-271 ANALYTICAL VERIFICATION Certitied Parameter Value" Proficiency Testing Study NIST Traceability Mean Recovery’ nn SRMNumber Recovery mgt mg * % Ammonia as N 12.0 12.0 99.9 180 194 100 Nitrate + Nitrite as N 118 114 951248185 102 Nitrate as N 115 115 07 14918 102 otho-Phosphate as P 2.96 233 67 137—=S«186 101 Page 1 of 2 Lot: P273-505, 16341 Table Mountain Pkwy + Golden, CO 80403 + T: 800.372.0122 » 303.431.8454 » www.eragc.com Reference Materials « Certificate of Analysis = {,,The Certied Values sre the actual "made-o" concentrations confimed by ERA analytical verication, The carted values are montored and purchasers [il be notified of any sigriteant changes resuting in recertiicaion or withdrawal of his cetiied reference matoral during the period ot valaty et re cateate, 2 The Uncertainty i he total propagated uncertainty atthe 85% confidence interval. The uncertainty is based on the preparation and intral analytcal ‘etication of the product by ERA multpiod by a coverage factor, The uncertainty applies tothe product as supplied and soos not take nto seem ary equred oF optional dilution andor preparations the laboratory may perform while ving ths procuek ,[Re,.0G Performance Acceptance Limits (QC PALS™Jare based on actual historical data colcted in ERA’s Proficiency Testing program. The QC PALS rofet any inherent biases in the methods usod to establsh the lis and closely approximate a 95% confidence nienal of feeraormanes rat experienced laboratories should achieve using accepted erronmntl methods. Use the GC PALs™ to realstealy evavae your performance seam vour Pe 4. The PT Performance Acceptance Limits (PT PALs™) are calculated using the regression equations and fixed accoptance etera specified inthe NELAC proficiency testing requirements. Use the PT PALS™ when analyzing iis QC standard alongside USEPA and NELAG complant Py srendene Flease note hat many PT study acceptance limits are concentration dependent (some non-ineaty and, theelore, he acceptance sol Se Standard and ary PT standard may der rlaive to thew diference in concentrations, §, The PT DateTraceabity dst include the mean value, percent recovery and numberof dala points reported by he laboratories in our Pofcency ‘Testing study compared te he Ceried Values. In addon, where NIST Standara Reference Materials (SAMs) ar@ avaiable, ach arate tes nee? analytcaly traced othe NIST SAM listed. This products traceable othe lot numbers of ts starting materials, All gravimett and Volarete neseerements ‘elatd to is manufacture ae traceable to NIST through an unbroken chain of comparisons, Traceability Recovery (*)» (% recovery ceriad standard)/(s recovery NIST SEMI| "00 The traceablty data shown were compiled by analyzing the ERA standards or hl assocated stock solutions agains the applicable NIST SAMS. 6. Fer adcitonalnformaten on this product such as intended uso, Instructions for use, level ot homogenely, and safety information, please rofer tothe Provided Instuetion Shest If you have any questions or need technical assistance, please call ERA technical assistance at 1-800-372-0122 or send an email to info@eraqc.com. Certifying Officer Quality Officer Brian Miller David Kithefner Eictapg Pll Page 2 of 2 Lot: P273-505 16341 Table Mountain Pkwy « Golden, CO 80403 = 800.372.0122 + 303.431.8454 + www.eragc.com @ERA @ ‘A Waters Company Instructions for Catalog # 505 Simple Nutrients Revision 030512 Description: This standard is packaged in a 15 mL screw-top vial containing approximately 14 mL of standard concentrate. This concentrate is preserved with approximately 1%(v/v) hydrochloric acid. ‘The concentrate can be stored at room temperature. This product is intended to be used as a quality control check of the entire analytical process for the analytes/matrix included in the standard ‘The dilution instructions below represent the minimum suggested sample size for this product. Using a smaller sample size may invalidate the assigned value and/or uncertainty shown on the certificate of analysis. Helpful Hints: This standard has been prepared as a concentrate and must be diluted prior to analysis. For lebs using ion selective electrode methods, please note that this sample contains hydrochloric acid and chloride containing sats. ‘As the coneentrate contains hydrochloric acid, please note that the diluted sample will be acidic and may require pH adjustment depending on your analytical methods, Be sure to report your ammonia result as N (not as NHS), your nitrate result as N (not as NOs), your phosphate result as P (not as PO,” and your Nitrate + Nitrite result as N. ‘This standard should be analyzed as soon as possible after the concentrate is diluted. Instructions: 1 ‘Add 100-200 mL of deionized water to a clean 1000 mL class A volumetric flask. 2. Shake the Simple Nutrients vial prior to opening. 3. Using a clean, dry, class A pipet, volumetrically pipet 5.0 mL of the concentrate into the 1000 mL volumetric flask. 4, Dilute the flask to final volume with deionized water. 5. Cap the flask and mix well. 6. Immediately analyze the diluted sample by your normal procedures. 7. Report your results as mg/L for the diluted sample. Safety: ERA products may be hazardous and are intended for use by professional laboratory personnel trained in the ‘competent handling of such materials. Responsibility forthe safe use of these products rests entirely with the buyer and/or user. Material Safety Data Sheets (MSDS) for all ERA products are available by calling 1-800-372- 0122. (ERA SAFETY DATA SHEET This safety data sheet was created pursuant tothe requirements of 29 CFR 1910.1200, 7. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Product identifier Product Name ‘Simple Nutrients, WasteWatR™ Product Numb 505, ‘Synonyms None Recommended use of the chemic 9 Recommended Use Laboratory use only Uses advised against No information avaliable Supplier ERA, A Waters Company Supplior Address 16341 Table Mountain Parkway, Golden, CO 80403 USA Non-Emergency Telephone Number +1-303-431-8454 Email address sdsinfo@eraqe.com Emergency telephone number Company Emergency Phone _In caso of EMERGENCY call CHEMTREC Day or Night, Number Within USA and Canada: 800-424-9300 Intemational Cli Collec: +1-703-527-3887 2. HAZARDS IDENTIFICATION Classification ‘This chemical considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) (Sem conosionteiaion [eaten [Serious eye damageleye initation iegory 1 Korrosive to Netals. [Category T -autionary statemé Emergency Overview Bignal word Warning "auses severe skin bums and eye damage fay be corrosive to metals Page 1/12 505 Simplo Nutrients, WasteWatR’ Revision Date 25-1u1.2016 Appusance Clay clans Physi state Li oder ossos| Precautionary Statements - Prevention Keep only in orginal container Precautionary Statements - Response Eyes IF IN EVES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing Immediately call a POISON CENTER or doctor/physician Skin IF ON SKIN (orhair): RemoverTake off imme ‘Wash contaminated clothing before reuse tly all contaminated clothing. Rinse skin with waterlshower Inhalation IF INHALED; Remove victim to fresh air and keep at res in a position comfortable for breathing Immediately call a POISON CENTER or doctoriphysician Ingestion IF SWALLOWED: Rinse mouth, DO NOT induce voriting Spill ‘Absorb spillage fo prevent material damage Precautionary Statements - Storage ‘Store in corrosive resistant container with a resistant inner liner Precautionary Statements - Disposal Dispose of contents/container to an approved waste disposal plant Hi otherwise classifi QC) Not applicable Unknown Toxicity 0.00055 % ofthe mixture consists ofingredient(s) of unknown toxicity ther information May cause sligh eye irtation Interactions with Other Chemicals No information available, ‘3. COMPOSITION/INFORMATION ON INGREDIENTS [Ghemical Name CAS No Weight igh immonium Chioie 72125-02-5 (0.08 - 15 Hydrochloric Aci 7647-01-0, 04a 4. FIRST AID MEASURES Page 2/12 505~ Simple Natronts, WasteWatR™ Rovision Date 25-Ju-2016 General Advice. Eye contact Skin contact Inhi tion Self-protection ofthe first alder Immediate medical attention is required. Show this safely data sheet to the doctor in attendance, Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep eye wide open while rinsing. Do not rub affected area. Seek immediate medical altention/advice. Remove contact lenses, if present and easy to do. Continue rinsing, Immeciate medical attention is required. Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. Remove to fresh air. If not breathing, give artifical respiration. Avoid direct contact with skin. Use bartir to give mouth-to-mouth resuscitation. If breathing is dificult, (rained personnel should) give oxygen. Do NOT induce vomiting. Rinse mouth immediately and drink plenty of water. Never give ‘anything by mouth to an unconscious person. Call a physician or poison control center immediately Ensure that medical personnel are aware of the material(s) involved, ake precautions to protect themselves and prevent spread of contamination. Avoid direct contact with skin. Use barrier to give mouth-to-mouth resuscitation, ‘Most important symptoms and effects, both acute and delayed ‘Most important Symptoms and Burning. Effects Indication of eny Immediate medical attention and special nt n Notes to Physician Product is a corrosive material. Use of gastric lavage or emesis is contraindicated. Possible perforation of stomach or esophagus should be investigated. Do not give chemical antidotes. Asphyxia from glottal edema may occur. Marked decrease in blood pressure may occur with moist rales, frothy sputum, and high pulse pressure. Page 3/12 ‘505 Simple Nutrients, WasteWatR™ Revision Dato 25-Ju-2016 = = ee 5. FIRE-FIGHTING MEASURES _ Ree Suitable Extinguishing Media ‘C02 (except for Cyanides), dry chemical, dry sand, alcohol resistant foam. Water spray, fog or alcohol-resistant foam. Move Containers from fre area if you can do it without risk. Use water spray or fog; do not use straight streams. Dike fire control water for later disposal; co not scatter the material Jo extinguishing m: Note: Most foas will react withthe material and release corrosiveltoxic gases. si 7 the el Vapors may accumulate in confined areas (basement, tanks, hopperitank cars, ate). Substance will react with water (some Violently), releasing corrosive andlor toxic gases. Reaction with water may generate much heat which will increase the Concentration o fumes in the ai. Containers may explode when heated or if contaminated with water. Uniform Fire Code Corrosive: Other-Liquid Carbon oxides, ivity to Static Discharge No, Protective equi tons for firf Asin any fire, wear self-contained breathing apparatus pressure-demand, MSHAINIOSH (approved or equivalent) and full protective gear, 6. ACCIDENTAL RELEASE MEASURES. Personal precautions, protective equipment and emergency procedures Porsonal precautions ELIMINATE all ignition sources (no smoking, flares, sparks or lames in immediate area). ‘All equipment used when handling the product must be grounded. Do not touch damaged ‘containers or spilled material unless wearing appropriate protective clothing, Stop leak if you can do it without risk Other Information ‘Do not get water inside containers. Environmental precautions Environmental precautions Prevent entry into waterways, sewers, basements or confined areas, Use water spray to reduce vapors or divert vapor cloud drift. Avo allowing water runoff to contact spilled material Methods and material for containment and cleaning up ‘Methods for containment ‘A vapor suppressing foam may be used to reduce vapors. Cover with DRY earth, DRY ‘sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Methods for cleaning up Use clean non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. Soak up with inert absorbent material. Pick up and transfer to Properly labeled containers, Page 4/12 505 Simple Nutrlonts, WasteWatR™ Revision Date 25-JuL2016 HANDLING AND STORAGE Precautions for safe handling Handling Handle in accordance with good industrial hygiene and safety practice, Avoid contact with ‘kin, eyes or clothing. In case of insufficient ventilation, wear suitable respiratory, ‘equipment. Use only with adequate ventilation and in closed systems. Do not eat, drink or ‘smoke when using this product. Take off contaminated clothing and wash before reuse. Conditions for safe storage, including any incompatibilities Storage ‘Keep containers tightly closed in a dry, cool and well-ventilated place. Protect from ‘moisture. Store locked up. Keep out ofthe reach of children, Store away from other materials Incompatible Products ‘Acids. Bases. Oxidizing agent. 8, EXPOSURE CONTROLS/PERSONAL PROTECTION ‘Control parameters Exposure Guidelines ‘Chammieal Name ACGATLY, ‘OSHA PEL, ‘Amorim Chloe ‘STEL: 20 mg/n® fame [vacated] TWA: 10 mg/m —tuma| 12125402-9 TWA: 10 maim fume (Vacated) STEL!20 mgin® STEL: 20 mgm? fue fume Fiyeroahiore Aaa Galina: 2pm Vacated) Ceiing Spm. TDL SO ppm 7647-01-0. (vacated) Ceting 7 mgin® Caiing:§ ppm Celing: § ppm CCeling: 7 maine cating: 7 mai? ‘ACGIH TLV. Armaican Conference of Govemmantal Industal Hygienists ~ Threshold Limit Value OSHA PEL. Occupational Safely and Heath ‘Administration - Permissible Exposure Limits NIOSH IDLH Immedtately Dangorous 1 Life or Heath Other Exposure Guidelines ‘Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962 (11th Cir, 1992) Appropriate engineering controls Engineering Measures Showers Eyewash stations ‘Ventilation systems {Individual protection measures, such as personal protective equipment Eyelface protection Face protection shield ‘Skin and body protection Wear protective gloves and protective clothing. Long sleeved clothing. Chemical resistant apron, Impervious gloves, Respiratory protection No protective equipment is needed under normal use conditions. If exposure limits are ‘exceeded or iritation is experienced, ventilation and evacuation may be required Hygiene Measures, Handle in accordance with good industrial hygiene and safety practice. Avoid contact with ‘skin, eyes or clothing. Wear suilable gloves and eyeiface protection. Do not eat, drink or ‘smoke when using this product. Take off contaminated clothing and wash before reuse. Contaminated work clothing should not be allowed out of the workplace. Regular cleaning (of equipment, work area and clothing is recommended. Wash hands before breaks and Page 5/12 {505 Simplo Nutrients, WastaWatR™ Revision Date 25-JuL2016 immodiately after handing the product. For environmental protection, remove and wash all ‘contaminated protective equipment before re-use. 9. PHYSICAL AND CHEMICAL PROPERTIES. Physical state Liquid ‘Appearance Clear, coloriess Color No information available Property. vi pH 2 Molting /treezing point 10 data available Boiling point boing range no data available Flash Point no data avaliable Evaporation Rate no data avaliable Flammability (sold, gas) no data available Flammability Limit in Air Upper flammability limit no data available Lower flammability limit fo data avaliable Vapor pressure no data avaiable Vapor density fo data avaiable Specific Gravity t Water Solubiity Soluble in water Solubility in other solvents 10 data avaiable Partition coefficient: n-octanoliwaterno data avaiable ‘Autoignition tomperature no data avaiable Decomposition temperature No data available Kinematic viscosity fo data avaiable Dynamic viscosity fo data avaiable Explosive properties no data avaiable Oxidizing properties no data avaiable ther Information Softening Point ro data avaliable Vor Content (%) ‘no data available Particle Size no data available Particle Size Distribution Odor Odor Threshold ‘Remarks Method "None known "None known None known None known None known None known None known None known None known "None known None known None known None known None known Oderiess No information avaitable Page 6/12 {505 ~ Simple Nutrionts, WastewatR™ Revision Date 25-JuL2016 410, STABILITY AND REACTIVITY Reactivity no data availale, ‘Chemical stability Stable under recommended storage conditions. Possibility of Hazardous Reactions None under normal processing Hazardous Polymerization Hazardous polymerization does not occur. Conditions to avoid Exposure to air or moisture over prolonged periods. Incompatible materials ‘Acids. Bases. Oxidzing agent Hazardous Decomposition Products Carbon oxides. 11. TOXICOLOGICAL INFORMATION Information on likely routes of exposure Product Information Inhalation ‘Specific test data forthe substance or mixture is not available. Corrosive by inhalation, (based on components). Inhalation of corrosive fumesigases may cause coughing, choking, headache, dizziness, and weakness for several hours. Pulmonary edema may occur with tightness in the chest, shoriness of breath, bluish skin, decreased blood pressure, and increased hear rate. inhaled corrosive substances can lead to a toxic edema of the lungs. Pulmonary edema can be fatal Eye contact ‘Specific test data forthe substance or mixture is not avaliable. Causes burns. (based on Components). Corrosive tothe eyes and may cause severe damage including blindness, Skin contect ‘Spesifc test data forthe substance or mixture is not availabe. Corrosive. (based on Components). Causes burns. Ingestion ‘Specific test data fr the substance or mixture isnot availabe. Causes bums. (based on ‘Component information ‘Components). Ingestion causes bums of the upper digestive and respiratory tracts. May ‘cause severe burning pain in the mouth and stomach with vomiting and diarrhea of dark blood. Blood pressure may decrease. Brownish or yellowish stains may be seen around the ‘mouth. Swelling ofthe throat may cause shortness of breath and choking. May cause lung damage if swallowed. May be fatal if swallowed and enters airways. (Chemical Name. ‘Oral L050 Dermal (O50 Tahalation LO5O srmonium Chiowde = 7650 mphkg (Rat) - : 12125-02.9 ‘yorochone Re 238-277 wag (Rat) SBoT0 male (Raber) Bema (Rat) TH re47-03-0 Information on toxicological effects, Page 7/12 {505 ~ Simple Nutrlents, WasteWath™ Revision Date 25-JuL2016 Symptoms Erythema (skin redness). Burning, Coughing and/ or wheezing, late. well a 1 Jo Sonsitization No information availabe, Mutagenic Effects No information available. Carcinogenicity ‘The table below indicates whether each agency has listed any ingredient as a carcinogen, (Franieal Name ACG TAR NP ‘OSHA iycrochlorie Ada Group 7 a 7847-01-0. Group 3 TARC (Interational Agency for Research on Cancer) Group 3 - No Clasifabo as © Carcinogenioty in Humans Reproductive toxicity No information availabe STOT- single exposure No information availabe STOT - ropeated exposure No information availabe. Chronie Toxicity No known effect based on information supplied. Effects from this product caused by acute exposure may cause permanent damage to target organs andlor may cause chronic cconcitions. Chronic expasure to corrosive fumesigases may cause efosion of the teeth, followed by jaw necrosis. Bronchial initation with chronic cough and frequent attacks of Pneumonia are common. Gastrointestinal disturbances may also be seen, Carcinogenic potential is unknown, ‘Target Organ Effects Respiratory system. Eyes. Skin. Gastrointestinal tract (Gi). Aspiration Hazard No information available, ‘Numerical measures of toxicity Product Information ‘The following values are calculated based on chapter 3.1 of the GHS document ATEmix (oral) 43,813.00 mgfky ATEmix (Inhalation-dustimist) 125.25 mol. ATEmix (inhalation-vapor) 1750.00 ATEmix Page 8/12 505 Simple Nutrients, WasteWatR™ Revision Date 25-Ju.2016 42, ECOLOGICAL INFORMATION ee Ecotoxicity. Hlarmful to aquatic life, ‘Chemical Name "Toxiciy to Algse Toxiciy to Fish Toxicity ‘Daphnia Magna (Water Microorganisms Flea) “rimoniam Ghowde Sen LCH= BOSS BR LCBO: = 202 aL 12125029, (Cyprinus carpio) 24h LCSo: £725 mal. (Lepomis, macrochius) Fyaroahiovs Aaa BERL CSO: = 282 mg 7647-01. (Gambusia aris) istence and Degradabil No information available. Bioaccumulation No information available Other adverse effects No information available. 43. DISPOSAL CONSIDERATIONS Waste treatment methods Disposal methods ‘This material, as supplied, Is not a hazardous waste according to Federal regulations (40 CFR 261). This material could become a hazardous waste iit is mixed with or otherwise ‘comes in contact with a hazardous waste, if chemical additions are made to this material, or ifthe material is processed or otherwise altered. Consult 40 CFR 261 to determine whether the altered material is a hazardous waste. Consult the appropriate state, regional, of local regulations for additional requirements. Contaminated Packaging Dispose of contents/containers in accordance with local regulations. US EPA Wasts Number o02 California Hazardous Waste Codes 731 ‘This product contains one or more substances that are listed with the State of California as a hazardous waste. 44, TRANSPORT INFORMATION _ por UN-No. uN17¢9 Proper Shipping Name HYDROCHLORIC ACID Hazard Class 8 Packing Group ML Descriptien UN1789, HYDROCHLORIC ACID, 8, I Emergency Response Guide 157, Number Tos UN-No. UNt789 Proper Shipping Name HYDROCHLORIC ACID Page 9/12 505 Simple Nutrients, WasteWath™ Revision Date 25-JuL2016 Hazard Class Packing Group Description MEX. UN-No. Proper Shipping Name Hazard Class Packing Group Description Icao UN-No. Proper Shipping Name Hazard Class Packing Group Description IATA UN-No. Proper Shipping Name Hazard Class Packing Group ‘Special Provisions Description IMDgiIMO Hazard Clas Packing Group EmS-No. ‘Special Provisions. Marine Pollutant Description RD UN-No. Proper Shipping Name Hazard Class Packing Group Cla ‘Special Provisions. Description ADR. UNNo. Proper Shipping Name Hazard Class Packing Group Classification code Tunnel restriction code Special Provisions Description ADN. UN-No, Proper Shipping Name Hazard Class Packing Group Classification code ‘Special Provisions Description 8 I UN1789, HYDROCHLORIC ACID, 8, I UN1789 HYDROCHLORIC ACID 8 Mw UN1789, HYDROCHLORIC ACID, 8, I UN1789 HYDROCHLORIC ACID 8 w UN1789, HYDROCHLORIC ACIO, 8, Il uNt789 HYDROCHLORIC ACID 8 mW None UN1789, HYDROCHLORIC ACID, 8, I UNt789 HYDROCHLORIC ACID 8 m FASB None Not applicable UN1789, HYDROCHLORIC ACID, 8 Ill uNt789 HYDROCHLORIC ACID 8 UI 1 None UN1789, HYDROCHLORIC ACID, 8, uN1789 HYDROCHLORIC ACID 8 M c ©. None UN1789, HYDROCHLORIC ACID, 8, I uN1789 HYDROCHLORIC ACID 8 M a 520 UN1789, HYDROCHLORIC ACID, 8, I Page 10/12 505 Simple Nutrients, WasteWath™ Revision Date 25-Jul-2016 Hazard Labels a Limited Quantity BL 45. REGULATORY INFORMATION Intern: ries TSCA Complies Dst ‘All components are listed either on the DSL or NDSL. ENCS Contact supplier for inventory compliance status lecsc = KECL Contact supplier for inventory compliance status Pices Contact supplier for inventory compliance stalus Alcs Contact supplier for inventory compliance status ‘TSCA United States Toxic Substances Control Act Section 6b) Inventory DSLINDSL - Canadian Domestic Substances ListNor-Domestic Substances List EINECSIELINGS - European Inventory of Existing Chemical Substances/European List of Notffad Chemical Substances NCS - Japan Existing and New Chemical Substances IECSC China Inventor of Existing Chemical Substances KECL - Korean 2stng and Evaluated Chemical Substances PICCS - Philippines Inventory of Chemicals and Chemical Substances AICS - Australian Inventory of Chemical Substances: US Federal Regulations. SARA313, Section 313 of Tite Il of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product contains a chemical ‘chemicals which are subject tothe reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372 Femieal Name CAS No Weignt% ‘SARASIS- Threshold Values % imontum Chords 12125025, TOS Doe-15 19, Hiyerochire Acd - 7647-07-0, TeAT-OF-0 048 7 ‘Acute Health Hazard Yes Chronic Health Hazard No Fire Hazard No ‘Suddon release of pressure hazard No Reactive Hazard No CWA (Clean Water Act) ‘This product contains the following substances which are regulated pollutants pursuant to the Clean Water Act (40 CFR 122.21 and 40 CFR 122.42) ‘Chemical Name ‘GWA- Reportable] CWA-Toxie Pollutants | CWA- Priority Pollutants | CWA-Hazardous Quantities Substances “rimonium Crone 5000 x 12125029 Tiydrochione Ada 00 x 7647-01-0, CERGIA ‘This material, as supplied, contains one or more substances requlated as a hazardous substance under the Comprehensive Environmental Response Compensation and Liabilty Act (CERCLA) (40 CFR 302) ‘Chenieal Name Hazardous Substances Rs [Extremely Hazardous Substances] Ra Ras, “Arrmonm CHorae 3000 RO5000 b inal RE 1225.02.95 RQ 2270 kg fnal RO Fyarostione Add oo 000 RQ 5000 Ib fnal RO TEA7-01-0. RQ 2270 kg final RO US State Regulations Page 11/12 505 Simple Nutrients, WasteWatR’ Revision Date 25-Jub-2016 California Proposition 65 This product does not contain any Proposition 65 chemicals. 3. State Right-to-K; ulations ‘Chemical Name New Jersey | Massachusets| ian | —inois Wi 7132-185 Potassium Nivate x x x Tisr704 “Arionium Crioide x x 12125.02.9 Fitrochlorc Aca Fs x * 7e47-09-0 Internatior ions Mexico lational occupational exposure limits ‘Component Carcinogen Status Exposure Units “Ammonium Chien Mexico: TWA 10 maine 12125-02-0 (008-15) Mexico: STEL 20 maim? Fiydrocniorc Aad Mexico: Celing 5 ppm 7687-01-0 (0.44 Mexico: Caling 7 maim? fexico- Occupational Exposure Lima ~ Caramogans Cana WHMIS Hazard Class Not determined 46. OTHER INFORMATION NFPA Health Hazards 3 Flammability 0 _Instability 0 Physical and Chemical Hazards - HMIS Health Hazards 3° Flammability 0 Physical Hazard 0 Personal Protection x Prepared By Product Stewardship 23 British American Bivd, Latham, NY 12110 1-800-572-6501 Issuing Date 13-Apr-2016 Revision Date 25-Jul-2016 Revision Note No information available Disclaimer ‘The information provided inthis Safety Data Sheet is corec tothe best of our knowledge, information and bella at the date of its publication. The Information given i designed only as a quidance for safe handing, use, processing, storage, reneportalion, disposal ard ieloase ard ann torre ‘considered a waranty or quality specifeaton. The information relates cnly to the speci material esignalsd and may not be vali for such ‘materia sed in combination with anyother matorials orn any process, unless specified in the text is SDS, and all information inthis SOS was provided by the supplier or was reproduced tr publicly avalabie regulatory dole seuss, UL makes ro representations or warrants regarding the completeness or accuracy ofthe information in his SDS and dscaime a iebity in connection withthe use ofthis information or the substance desenbed in this SDS, The layout appearance and format of ne @OS eo 2014 ULLLC. Al rights reserved Oz suppl identified below generated this SDS using the UL SOS template. UL dd not est, cerily, or approve the substance described in End of Safety Data Sheet Page 12/12

You might also like