Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

STRUCTURE ANALYSIS

Site ID :-
Site Name :-

Status :
Accepted On Hold
Diterima Ditunda
Rejected Technical Problems
Ditolak PermasalahanTeknis

Comments :
Komentar

Signature/Date : Signature/Date :
Tandatangan Tandatangan

……………………… ………………………
SUMMARY STRUCTURE
ANALYSIS
Site Name : Cafe Flores
Site ID :-

Data
Height : - m Base Level : 0.00 m
Loading
Dimension Elevation Weight Total Weight
Description Quantity
(m) (m) (kg) (kg)
INITIAL LOAD

Design Output Summary


Description Output Comparison Limitation Remarks
Maximum stress ratio (Maximum Wind velocity 126 kph)
Main Structure 0.201 ≤ 1.00 OK
UNP 50x38x5 mm

Stairs structure is still strong enough to support loading


ANALYSIS CRITERIA
A. STANDARD DESIGN

Standard design in the tower is taken :


a. American Society of Civil Engineers (ASCE/SEI 7-10)
b. American Institute of Steel Construction (AISC-LRFD 360-10).
c. American Society for Testing and Materials (ASTM).
d. SNI 03-1729-2015 (Tata Cara Perencanaan Struktur Baja)
e. The fabrication and materials of the tower will be according to the
relevant Indonesian and/or Japanese Industrial Standard.
f. American Concrete Institute (ACI 318-11).
g. Software : SAP2000 v.23.1.00

B. MATERIAL SPECIFICATION

Steel materials used for the towers and other equipment refer to regulations

Indonesian Industry standard (SII and SNI), Japanese Industrial Standard (JIS), and

American Society for Testing and Materials (ASTM).

a. Specific Gravity
- Steel = 7850 kg/m3
- Concrete = 2400 kg/m3
b. Modulus of Elasticity
- Steel Es = 2 x 105 MPa
- Concrete Ec = 4700 x √𝑓𝑐′ MPa
c. Material Specification

Fy Fu
Material Standard Grade
MPa MPa
Steel Section ASTM A36/JIS G3101 SS 400 245 400
Plate ASTM A36/JIS G3101 SS 400 245 400
Pipe Section ASTM A53 SCH 40 235 400
Pipe Section ASTM A53 SCH 80 260 400
Bolts JIS B 1180 8.8 600 830
Nuts JIS B 1180 8 920
Anchor Bolts ASTM A307 C 240 400
Welds AWS D1.1 S460M / E70xx 460 550
Hot Dip Galvanized ASTM A123 70 Microns Thickness
D (Deformed) Bar Steel ASTM A615 / SNI BJTD 40 / U-39 390 559
Ø (Reinforcing) Bar Steel ASTM A615 / SNI BJTP 24 / U-24 235 382
C. LOADING

a. Dead Load (DL)


Dead load is weight of stair structure.

b. Live Load (SDL)


Live load is weight of person is assuming 2 person,
live load is taken 300 kg/m2.

c. Load Combinations
Structures shall be designed so that their design strength equals or exceeds the
load effects of the factored loads in each of the following limit state
combinations.
- Design Strength
1.4 DL
1.2 DL + 1.6 LL

D. STRUCTURE ANALYSIS CONDITION

The structure analysis has been carried out using SAP2000. The following
condition were made in structural analysis :
Design Strength :
Stress Ratio, with maximum limit 1.00