Professional Documents
Culture Documents
Design Guide 16 Revisions and Errata List
Design Guide 16 Revisions and Errata List
Design Guide 16 Revisions and Errata List
The following list represents corrections to the first printing (dated 2002) of AISC Design Guide 16, Flush and Extended
Multiple-Row Moment End-Plate Connections.
Page(s) Item
11 In the left column, Equation 2-11 should read:
2
w ′tp2 ⎛ Fi ′
⎝
2
Qmax, i = − 3⎜
F py
⎜
4 ai w ′t p
⎝
⎛
⎛ bp ⎞ πd 3 F
tp2 Fpy ⎜ 0.85 + 0.80 w′ ⎟ + b t
⎝ 2 ⎠ 8
Fi′ =
4 pf,i
3
⎛ tp ⎞
3.682 ⎜ ⎟ − 0.085
ao = ⎝ db ⎠
Pext − Pf,o
min
34 In Table 4-3, Case 1, ϕMn = ϕyMpl = ϕyFpytp2Y should be ϕMn = ϕbMpl = ϕbFpytp2Y.
41 In the left column, section “4.2.2 Four-Bolt Extended Unstiffened Moment End-Plate Connection (Table 4-3)”
should be replaced with “4.2.2 Four-Bolt Extended Stiffened Moment End-Plate Connection (Table 4-3).”
47 In the right column under Design Procedure 1, the expression “db = d in.” should be replaced with “db = s in.”
AISC DESIGN GUIDE 16 / FLUSH AND EXTENDED MULTIPLE-ROW MOMENT END-PLATE CONNECTIONS / 1
Page(s) Item
63 The decision diamond near the bottom of the flow chart should read:
ϕ b M pl
ϕ M np ≤
1.11
65 The decision diamond near the bottom of the flow chart should read:
ϕ b M pl
≤ ϕ Mq
γr
2 / FLUSH AND EXTENDED MULTIPLE-ROW MOMENT END-PLATE CONNECTIONS / AISC DESIGN GUIDE 16