The Walker P1066 True Wind Interface calculates True Wind Angle and Speed and also
Theoretical Wind Angle and Speed from the best available data.
Using any combination of NMEA 0183 “VBW”, “VHW”, “HDT”, “VTG” and “MWV”
(Relative) sentences, input on any of the three input channels, the P1066 extracts data which is
then used to calculate True and Theoretical Wind Angle and Speed. This resultant data is then
sent to Output Channel 1 (on EMC socket) and Output Channel 3 connection terminals, as
NMEA “MWV” (Theoretical) and NMEA “MWD” sentences.
Any NMEA 0183 “VBW”, “VHW”, “HDT”, “VTG” and “MWV” (Relative) sentences seen on
input channels 1, 2 and 3, are checked for validity and passed through to output channels 1 and 3,
at a rate of 1 per second.
Any two input “MWV” (Relative) NMEA sentences with Relative Wind Speed in the one and
Relative Wind Angle in the other are combined into 1 message and passed through to output
channels 1 and 3.
Irrespective of the frequency of input NMEA sentences, all NMEA output sentences are sent at a
rate of 1 per second. The most up to date data is always transmitted.
Any propitiatory PLG Remote dimming sentences, seen on input channel 3, are checked for
validity and passed through to output channel 2 (on EMC socket).
The interface therefore provides Walker Analogue, and Digital, “relative”, “true” and
“theoretical” wind indicators (P305 / P316 series) with appropriate NMEA 0183 serial data input
from the connected EMC socket. Output channel 3 is available for connecting to Walker P1249
Wind Data Displays or to other listeners.
.
A “power fail” alarm circuit is included.
24vDC outputs are available at each of the three Input Channels for powering the full range of
Walker wind sensors, remote dimmer, or other appropriate talkers on the system concerned.
An “L” shaped plate is used to clamp overall screen of cables used to the interface. Further, five
“earth” terminals; fitted to an internal “grounding” bar, allow for connection of any additional
screens of individual or multiple twisted pair cables that may be involved.
The “earth” lead, attached to the external earth stud must be suitably bonded to ship’s earth to
provide full EMC protection.
© John Lilley and Gillie Ltd. Ref: P1066/ds/ra/174 Issue 2
WALKER P1066 Page 2 of 11
TRUE WIND INTERFACE
The unit requires a 24vDC power supply. A diode is fitted for polarity protection and transient
voltage protection is also included.
Maximum current consumption is 250mA when interface is powered up but is not providing 24v
DC feed to other units.
INSTALLATION
The unit is not watertight and must be fitted below deck in a protected position that will allow
for all interconnections. Accessibility of the box, both for diagnostic purposes, and for any
possible future replacement, also needs to be taken into consideration. Four mounting holes are
provided externally, through fitted grommets; one at each corner of the base plate for mounting
to either a horizontal, or to a vertical surface, using M4 pan head screws (or equivalent self
tapping screws) and washers.
A slot in the side of the box allows for cable entry and the “L” shaped plate with its attached
conductive fabric wrap allows the exposed overall screen of the cables concerned to be clamped
to the conductive fabric wrap attached to the base plate. The “L” shaped clamp plate runs on two
pozi-pan head screws and having brought the plate down sufficiently to compress the fabric
wrap against the laid in cables / screens, hold the plate in position and tighten the screws to
secure cables.
To ensure full EMC transient protection, the fitted M6 “earth” stud must be suitably bonded to
“ship’s earth” using the lead provided.
See drawing 3398-A3-2: installation drawing of the P1066 Wind Indicator Interface.
CABLING
The free plug of the 1 metre cable assembly, supplied with a P305 / P316 series wind indicator,
is connected directly to the EMC socket fitted on the Interface Box.
Whilst recommended core sizes are specified for all shipyard cabling, cables having stranded
cores up to a maximum 2.5mm CSA can be accommodated by the plug in terminal headers
concerned.
A twisted pair cable with overall screen, 16/0.2mm (0.5mm CSA), is required for connecting the
ships 24vDC supply. DC power connections are as follows:
1
Overall screens of cables, which have been exposed and suitably clamped to the conductive fabric wrap, are
sufficient for EMC requirements. If any shipyard cables have been used that have twisted screened pairs and an
overall screen, then the overall screen must attach to the conductive fabric wrap, with the other screens being taken
to appropriate “Earth” terminals on the internal grounding bar.
© John Lilley and Gillie Ltd. Ref: P1066/ds/ra/174 Issue 2
WALKER P1066 Page 3 of 11
TRUE WIND INTERFACE
CABLING continued
All Walker serial data masthead sensors are connected using Walker P293 cable assemblies. The
cable concerned is four core with an overall screen. Two cores carry power up to the masthead
unit with the NMEA 0183 serial data (“MWV” relative sentence) processed by the masthead
sensor being carried back down on the other two cores. Refer to the P293 data sheet for
additional information.
Refer to details below for wind sensor input connections and see also drawing 3398-A3-4.
A Walker P292 or P296 Combined Wind Sensor, connected into Input Channel 1 or 2,
would leave the other Input Channel available to accept other suitable NMEA data from
another talker. Note that if no Walker Wind Sensors are used, Input Channels 1 and 2 are
both available to accept NMEA data from other talkers. If multiple NMEA 0183 sentences
are to be input into a single Input Channel they must be multiplexed before being input.
Note that, if required, each available Input Channel also contains a 24vDC output for
powering the talker/s concerned. Maximum current consumption of 500mA is available on
each of these channels.
Separately input NMEA 0183 data can be carried on a twisted pair cable with overall screen,
16/0.2mm (0.5mm CSA). If 24vDC power is also to be provided by the P1066 interface, from
either Input Channel 1 or Input Channel 2, to power the talker concerned, then either a twin
twisted pair cable with overall screen or a twin twisted screened pair cable with overall screen,
16/0.2mm (0.5mm CSA), can be used.
If the P325 Remote Dimming Control is to be fitted; connections between the P1066 True Wind
Interface and a P328 Universal Junction Box are necessary. Connections must be made using the
terminals stated below. Note it is recommended that Input Channel 3 of the P1066 be used to
connect through to a P325:-
This cable is to be provided by shipyard. Either a twin twisted pair cable with overall screen or a
twin twisted screened pair cable with overall screen may be used. In all instances cores of
16/0.2mm (0.5mm CSA) are recommended.
The P328 Universal Junction Box allows for inter-connection of this cable through to the P325
Remote Dimming Control. Refer to P325 and P328 Data Sheets for information.
Note that if no P325 Remote Dimming Control is used, Input Channel 3 is available to
accept NMEA data from another talker. If multiple NMEA 0183 sentences are to be input
at this Channel they must first be multiplexed.
Note that, if required, Input Channel 3 also contains terminals to provide a 24vDC output
for powering the talker concerned. Maximum current consumption of 500mA is available
on this channel.
Separately input NMEA 0183 data can be carried on a twisted pair cable with overall screen,
16/0.2mm (0.5mm CSA). If 24vDC power is also to be provided by the P1066 interface, from
Input Channel 3, to power the talker concerned, then either a twin twisted pair cable with overall
screen or a twin twisted screened pair cable with overall screen, 16/0.2mm (0.5mm CSA), can be
used.
CABLING continued
If the derived NMEA “MWV” (Theoretical) and NMEA “MWD” sentences are to be transmitted
to another listener, Output Channel 3 is used. A cable having a twisted pair with an overall
screen is required. Note that if the listener concerned requires a 24vDC power supply, this may
also be provided directly from Output Channel 3 provided that the current drawn by the listener
does not exceed 500mA. If utilizing this facility, either two individual cables of the
aforementioned type or a cable with twin twisted pairs (or twin twisted screened pairs), and with
an overall screen, will be required. All cables are to be provided by shipyard and cores of
16/0.2mm (0.5mm CSA) are recommended. Refer to details below for all Output Channel 3
connections.
If using the “Power Fail” alarm facility, a cable having a twisted pair with overall screen;
shipyard supply, is required. Cores of 16/0.2mm (0.5mm CSA) are recommended.
Relays fitted in connected indicator/s are all in parallel with the P1066 RL1 relay when full
system is connected.
An un-interruptible power supply, totally separate from the normal power supply fed to the
P1066 Interface at “24VDC” terminals, must be used for the alarm circuit.
IMPORTANT:
When preparing any o/all screen of cables for clamping to the conductive fabric wrap;
1) Ensure that the position of the exposed screen is sufficient to engage within the
confines of the conductive clamping area when the cable cores are themselves
connected into the appropriate terminals.
2) Also ensure that the exposed screening is clamped fully around 360º, i.e. around the
complete circumference of the cable, to provide fullest possible EMC benefit.
1) A DVM is used to check continuity between the external M6 earth stud and;
2) After bonding, check continuity between ship’s earth and the EMC socket on the
interface.
SERVICING:
FAULT FINDING:
LEDs are provided for customer confidence, diagnostic and fault finding purposes.
REFERENCES
SPECIFICATION
Note:
This document shall not form part of any contract.
In accordance with our policy of continuous development, changes may be made from time to
time without prior notice.
3398-A3-4
L
2. INPUT CHANNELS 1 AND 2 ARE BOTH USED WHEN A SEPARATE WIND SPEED SENSOR (P297 OR P299) AND A SEPARATE WIND DIRECTION
SENSOR (P298 OR P300) ARE CONNECTED. EITHER CHANNEL MAY BE USED FOR EITHER TYPE. IN SUCH INSTANCES ALL OTHER REQUIRED NMEA
CONNECTION DIAGRAM
DATA MUST BE MULTIPLEXED BEFORE BEING INPUT AT INPUT CHANNEL 3; A REMOTE DIMMER CANNOT BE USED IN THIS P1066 CONFIGURATION
(SEE SHEET 2).
DRAWING No.
3. INPUT CHANNEL 3 IS AVAILABLE FOR USE AS AN INPUT FOR REQUIRED MULTIPLEXED NMEA DATA OR ALTERNATIVELY IT IS USED FOR REMOTE
DIMMING, IF APPLICABLE (SEE SHEET 1).
K
4. OUTPUT CHANNEL 3 PROVIDES NMEA TRUE WIND OUTPUT TO WALKER P1249 WIND DATA DISPLAYS OR TO OTHER SHIP'S EQUIPMENT.
TITLE
5. IF INDEPENDANT (OR MULTIPLEXED) SERIAL DATA IS TO BE INPUT AT INPUT CHANNEL 1 / INPUT CHANNEL 2 / INPUT CHANNEL 3, ONLY "A" AND
"B" CONNECTIONS ARE USED (SCREEN IS NOT CONNECTED AT THE P1066 "LISTENER" END). 24vDC POWER IS ALSO AVAILABLE AT THESE INPUT
CHANNELS.
SEE NOTE No 6 FOR TERMINATION OF O/ALL SCREEN OF CABLE/S USED. SEE NOTE No 7 IF TWIN SCREENED TWISTED PAIR
CABLE WITH O/ALL SCREEN IS USED.
07/04/21
6. TRAP OVERALL SCREENS (360 ) OF CABLES IN "L" CLAMP, COMPRESSING THE CONDUCTIVE FABRIC WRAP FOR CONNECTION.
J
SCALE
DATE
7. ANY TWISTED PAIR SCREENS SEPARATE FROM THE O/ALL CABLE SCREEN MAY BE CONNECTED TO EARTH STRAP TERMINALS AS APPROPRIATE.
NTS
NOTE THAT ALL CABLES (OTHER THAN P293 CABLE ASSEMBLIES) CARRYING INPUT NMEA 0183 DATA DO NOT HAVE THEIR SCREEN CONNECTED AT
THE P1066 "LISTENER" END.
8. ENSURE UNIT IS CONNECTED TO SHIPS EARTH VIA FITTED EARTH LEAD. TO INDICATOR VIA 1 METRE
R:\NEW INDEXING\3398
CAD : \PATH\FILENAME
CABLE ASSEMBLY
I
CABLE
EARTH LEAD
CHECKED BY
(OP CH1 / OP CH2)
TO WALKER P305 /
P316 SERIES WIND
DRAWN
FINISH
INDICATOR.
(c) J Lilley and Gillie Ltd Revision
PC
1 234 5
SL
PWROUTON
P1000 Series Motherboard 3385-PCB-2 6 7 8 9 10
-
Issue 1.0 R50 BackPanel
LCDDis LEDDis OP5CH IP5Ch OPSYNC
M1
M2
R31
H
R33
MH2 MH3
DIMENSIONS IN
R30
T1 T2 T3 T5 L11
R16 R17
FB5 D8
FB6
FB7
TOLERANCE
FB4
FB9
FB8 R3
U1 U4
D11
R5
R7
D2
D5
R1
MATERIAL
D12 D6
USED ON
R46 R52 L12
R38
R22
R42 R39
C10 R25
T6
D3
CH2
D9
CH3
CH4
CH1
D1
R6
D7
R2
D10
D4
R4
R8
R48
RT4 RT3 RT2
RT1
PSU Board
-
C15
L13
John Lilley & Gillie Ltd
U2
L10
G
R37 R44 R2
C16
C14
R47
3383-PCB-5 Issue A
R1 R36
R18
D19 R13 C11 C18
R19 R20 C17 C19
PWR3V3OK
R10 3V3 R24 R14
R23
Heartbeat R41
R21 R45
FWI
TXCH4
D6
E
D5 TXCH3 C15
PSU12V C8 L2
FB1
R7 R3 TXCH2
INTERFACE SHOWN
U2
J1
R9
TXCH1
+
IC7 IC6 D3 L6
C13
LINK L5 D17
R9
R5
Pb
F
ACT
POWER SUPPLYREVERSE
+
R8 R6
R27 R28
Channel1 NMEAok1 Channel2 NMEAok2 Channel3 NMEAok3
J1 J2
V+ V- A B V+ V- A B V+ V- A B V+ V- A B V+ V- V+ V- NO COM NC
E
COM
N/C
GREEN
BLUE
RED
YELLOW
+24v
+24v
+24v
+24v
0v
0v
0v
0v
A
A
B
B
A
B
CHANGE No.
7 7 7 D
DATE
PROJECTION
ISSUE
6 N/C
CHANGE No.
MULTIPLEXED A +24v
NMEA "A" 24v DC
NMEA DATA INPUT B 0v
NMEA "B" SUPPLY
FROM SUITABLE TALKER
B
0v
OPTION (ON/OFF SWITCH:
3398-A3-4
24v DC +24v
(IF REQ'D) CUSTOMER SUPPLY)
06/08/07
07/04/21
SCRN
DATE
A
CONNECT AT TALKER END ONLY NMEA "A" TRUE WIND DATA TO
B
NMEA "B" OTHER LISTENER
DRAWING No.
A
TERM "3" +24v
B OPTION
P328 UNIVERSAL TERM "4" 0v 24v DC
0v (IF REQ'D)
JUNCTION BOX TERM "2"
A
ISSUE
4
2
6
3
9
5
7
SHEET 2 OF 3
P1066 TRUE WIND INTERFACE
NOTES:
3398-A3-4
L
1. ONLY ONE CHANNEL IS USED WITH A P292 OR P296 COMBINED WIND SENSOR. EITHER INPUT CHANNEL 1 OR INPUT CHANNEL 2 MAY BE USED.
CONNECTION DIAGRAM
2. INPUT CHANNELS 1 AND 2 ARE BOTH USED WHEN A SEPARATE WIND SPEED SENSOR (P297 OR P299) AND A SEPARATE WIND DIRECTION
SENSOR (P298 OR P300) ARE CONNECTED. EITHER CHANNEL MAY BE USED FOR EITHER TYPE. IN SUCH INSTANCES ALL OTHER REQUIRED NMEA
DATA MUST BE MULTIPLEXED BEFORE BEING INPUT AT INPUT CHANNEL 3; A REMOTE DIMMER CANNOT BE USED IN THIS P1066 CONFIGURATION
DRAWING No.
(SEE SHEET 2).
3. INPUT CHANNEL 3 IS AVAILABLE FOR USE AS AN INPUT FOR REQUIRED MULTIPLEXED NMEA DATA OR ALTERNATIVELY IT IS USED FOR REMOTE
K
DIMMING, IF APPLICABLE (SEE SHEET 1).
TITLE
4. OUTPUT CHANNEL 3 PROVIDES NMEA TRUE WIND OUTPUT TO WALKER P1249 WIND DATA DISPLAYS OR TO OTHER SHIP'S EQUIPMENT.
5. IF INDEPENDANT (OR MULTIPLEXED) SERIAL DATA IS TO BE INPUT AT INPUT CHANNEL 1 / INPUT CHANNEL 2 / INPUT CHANNEL 3, ONLY "A" AND
"B" CONNECTIONS ARE USED (SCREEN IS NOT CONNECTED AT THE P1066 "LISTENER" END). 24vDC POWER IS ALSO AVAILABLE AT THESE INPUT
CHANNELS.
SEE NOTE No 6 FOR TERMINATION OF O/ALL SCREEN OF CABLE/S USED. SEE NOTE No 7 IF TWIN SCREENED TWISTED PAIR
07/04/21
CABLE WITH O/ALL SCREEN IS USED.
J
SCALE
6. TRAP OVERALL SCREENS (360 ) OF CABLES IN "L" CLAMP, COMPRESSING THE CONDUCTIVE FABRIC WRAP FOR CONNECTION.
DATE
NTS
7. ANY TWISTED PAIR SCREENS SEPARATE FROM THE O/ALL CABLE SCREEN MAY BE CONNECTED TO EARTH STRAP TERMINALS AS APPROPRIATE.
NOTE THAT ALL CABLES (OTHER THAN P293 CABLE ASSEMBLIES) CARRYING INPUT NMEA 0183 DATA DO NOT HAVE THEIR SCREEN CONNECTED AT
THE P1066 "LISTENER" END.
R:\NEW INDEXING\3398
CAD : \PATH\FILENAME
8. ENSURE UNIT IS CONNECTED TO SHIPS EARTH VIA FITTED EARTH LEAD. TO INDICATOR VIA 1 METRE
CABLE ASSEMBLY
I
TO FRONT DISPLAY PCB
CHECKED BY
EARTH LEAD
EMC SOCKET
DRAWN
(OP CH1 / OP CH2)
FINISH
CABLE
SATA
PC
SL
(c) J Lilley and Gillie Ltd Revision
1 234 5
-
PWROUTON
P1000 Series Motherboard 3385-PCB-2 6 7 8 9 10
H
M1
M2
R31
R33
DIMENSIONS IN
MH2 MH3
R30
TOLERANCE
T1 T2 T3 T5 L11
R16 R17
FB5 D8
FB6
FB7
FB4
FB9
FB8 R3
U1 U4
MATERIAL
D11
USED ON
R5
R7
D2
D5
R1
D12 D6
R46 R52 L12
R38
R22
R42 R39
C10 R25
T6
D3
CH2
D9
CH3
CH4
CH1
D1
R6
D7
R2
D10
D4
R4
R8
R48
RT4 RT3 RT2
RT1
-
PSU Board
C15
L13
John Lilley & Gillie Ltd
L10
G
T9 T10 T4
L1
3383-PCB-5 Issue A
R1 R36
R18
D19 R13 C11 C18
R19 R20 C17 C19
PWR3V3OK
R10 3V3 R24 R14
R23
Heartbeat R41
FWI
D6
E
D5 TXCH3 C15
PSU12V C8 L2
FB1
R7 R3 TXCH2
U2
J1
INTERFACE SHOWN
R9
TXCH1
+
IC7 IC6 D3 L6
C13
LINK L5 D17
R9
R5
WITH LID REMOVED
F
ACT
Pb
SUPPLYREVERSE
+
R8
R27 R6
R28
POWER
Channel1 NMEAok1 Channel2 NMEAok2 Channel3 NMEAok3
J1 J2
V+ V- A B V+ V- A B V+ V- A B V+ V- A B V+ V- V+ V- NO COM NC
E
COM
N/C
GREEN
GREEN
BLUE
BLUE
RED
RED
YELLOW
YELLOW
+24v
+24v
+24v
0v
0v
0v
A
A
B
CHANGE No.
7 7
D
DATE
PROJECTION
ISSUE
N/C
6 6 6 6 6 TO ALARM
CHANGE No.
COM
CIRCUIT
+24v
TO WIND SPEED P293 CABLE
SHEET 2 OF 3
24v DC
0v
SENSOR P297 OR P299 ASSEMBLY SUPPLY
TO WIND DIRECTION P293 CABLE (ON/OFF SWITCH:
B
06/08/07
A A
07/04/21
4
2
6
3
9
5
7
SHEET 3 OF 3
NOTES:
3398-A3-4
L
2. INPUT CHANNELS 1 AND 2 ARE BOTH USED WHEN A SEPARATE WIND SPEED SENSOR (P297 OR P299) AND A SEPARATE WIND DIRECTION
CONNECTION DIAGRAM
SENSOR (P298 OR P300) ARE CONNECTED. EITHER CHANNEL MAY BE USED FOR EITHER TYPE. IN SUCH INSTANCES ALL OTHER REQUIRED NMEA
DATA MUST BE MULTIPLEXED BEFORE BEING INPUT AT INPUT CHANNEL 3; A REMOTE DIMMER CANNOT BE USED IN THIS P1066 CONFIGURATION
(SEE SHEET 2).
DRAWING No.
3. INPUT CHANNEL 3 IS AVAILABLE FOR USE AS AN INPUT FOR REQUIRED MULTIPLEXED NMEA DATA OR ALTERNATIVELY IT IS USED FOR REMOTE
DIMMING, IF APPLICABLE (SEE SHEET 1).
K
4. OUTPUT CHANNEL 3 PROVIDES NMEA TRUE WIND OUTPUT TO WALKER P1249 WIND DATA DISPLAYS OR TO OTHER SHIP'S EQUIPMENT.
TITLE
5. IF INDEPENDANT (OR MULTIPLEXED) SERIAL DATA IS TO BE INPUT AT INPUT CHANNEL 1 / INPUT CHANNEL 2 / INPUT CHANNEL 3, ONLY "A" AND
"B" CONNECTIONS ARE USED (SCREEN IS NOT CONNECTED AT THE P1066 "LISTENER" END). 24vDC POWER IS ALSO AVAILABLE AT THESE INPUT
CHANNELS.
SEE NOTE No 6 FOR TERMINATION OF O/ALL SCREEN OF CABLE/S USED. SEE NOTE No 7 IF TWIN SCREENED TWISTED PAIR
CABLE WITH O/ALL SCREEN IS USED.
07/04/21
J
6. TRAP OVERALL SCREENS (360 ) OF CABLES IN "L" CLAMP, COMPRESSING THE CONDUCTIVE FABRIC WRAP FOR CONNECTION.
SCALE
DATE
NTS
7. ANY TWISTED PAIR SCREENS SEPARATE FROM THE O/ALL CABLE SCREEN MAY BE CONNECTED TO EARTH STRAP TERMINALS AS APPROPRIATE.
NOTE THAT ALL CABLES (OTHER THAN P293 CABLE ASSEMBLIES) CARRYING INPUT NMEA 0183 DATA DO NOT HAVE THEIR SCREEN CONNECTED AT
THE P1066 "LISTENER" END.
8. ENSURE UNIT IS CONNECTED TO SHIPS EARTH VIA FITTED EARTH LEAD. TO INDICATOR VIA 1 METRE
R:\NEW INDEXING\3398
CAD : \PATH\FILENAME
CABLE ASSEMBLY
I
TO FRONT DISPLAY PCB
EARTH LEAD
CHECKED BY
EMC SOCKET
(OP CH1 / OP CH2)
DRAWN
FINISH
(c) J Lilley and Gillie Ltd Revision
1 234 5
PWROUTON
PC
SL
P1000 Series Motherboard 3385-PCB-2 6 7 8 9 10
-
LCDDis LEDDis OP5CH IP5Ch OPSYNC
M1
M2
R31
H
R33
MH2 MH3
R30
DIMENSIONS IN
T1 T2 T3 T5 L11
R16 R17
FB5 D8
FB6
FB7
FB4
FB9
FB8 R3
U1 U4
TOLERANCE
D11
R5
R7
D2
D5
R1
D12 D6
R52
MATERIAL
R46 L12
USED ON
R38
R22
R42 R39
C10 R25
T6
D3
CH2
D9
CH3
CH4
CH1
D1
R6
D7
R2
D10
D4
R4
R8
R48
RT4 RT3 RT2
RT1
PSU Board
C15
L13
-
John Lilley & Gillie Ltd
U2
L10
T9 T10 T4
L1 R44 R2
R37
G
C14
R47
R43
3383-PCB-5 Issue A
R1 R36
Heartbeat R41
R21 R45
PPNM
DExP PWR5VOK R4 Q3
C5
FWI
TXCH4
D4 R13
IC5
D6
E
D5 TXCH3 C15
PSU12V C8 L2
FB1
J1
INTERFACE SHOWN
R9
TXCH1
+
IC7 IC6 D3 L6
C13
LINK L5 D17
R9
R5
ACT
POWER SUPPLYREVERSE
Pb WITH LID REMOVED
+
R8 R6
R27 R28
F
Channel1 NMEAok1 Channel2 NMEAok2 Channel3 NMEAok3
J1 J2
V+ V- A B V+ V- A B V+ V- A B V+ V- A B V+ V- V+ V- NO COM NC
COM
N/C
+24v
+24v
+24v
+24v
+24v
0v
0v
0v
0v
0v
A
A
A
B
E
CHANGE No.
D
DATE
PROJECTION
ISSUE
MULTIPLEXED NMEA A
NMEA "A"
DATA INPUT FROM B N/C
NMEA "B" 6 6 6 TO ALARM
SUITABLE TALKER 0v COM
OPTION CIRCUIT
24v DC +24v
CHANGE No.
MULTIPLEXED NMEA A
NMEA "A"
DATA INPUT FROM B (ON/OFF SWITCH:
NMEA "B" CUSTOMER SUPPLY)
SUITABLE TALKER 0v
B
B
07/04/21
+24v
MULTIPLEXED NMEA A OPTION
NMEA "A" 0v 24v DC
DATA INPUT FROM B (IF REQ'D)
DRAWING No.
NMEA "B"
SUITABLE TALKER 0v
OPTION CONNECT AT
24v DC +24v
(IF REQ'D) TALKER END ONLY
A
ISSUE
SCRN
1
2
1
4
2
6
3
9
5