1. Select the service screen and enable the password protected Service Mode as shown in illustration 1
ntia .
lG
ree
n
Illustration 2 g03809444
2. Once the Service Mode is enabled, proceed to the Configurations screen to alter the Autolube Interval as shown in Illustration 2. The pump
interval can be set from 15-60 minutes in 15 minute increments, or 60-240 minutes in 30 minute increments.
Note: The default interval is 60 minutes.
Changing the Metering Unit on Model No. 85770-1, -2, -3, -4, -5, -6,
85771, 85772, 85780-1, -2, -3, -4, -5, -6, 85781, 85782, and 85785-1, -2,
-3, -4, -5, -6, -7, -8,-9, -10 SL-V Injectors
Illustration 3 g03672802
(A) 449-3815 Adjustment Screw
(B) 449-3816 Locknut
(C) 420-0939 Adjustment Sleeve, 420-0940 Adjustment Sleeve, 420-0941 Adjustment Sleeve, and 420-0942 Adjustment Sleeve
The automatic lubrication system offers the ability to change the amount of grease that is supplied per cycle to each grease point. Changing the
grease supply amount is completed by adjusting lock nut (B) or replacing spectrum adjustment sleeve (C) on the injector. See Table 1 for
reference.
.Spectrum Adjustment System The Spectrum adjustment system consists of a set of color-coded anodized aluminum adjustment sleeves (C).
Adjustment sleeves (C) provide an easy way to adjust the output of the injectors and provide a clear indication of the output setting. The spectrum
adjustment system allows for easy system installation and preventative maintenance.
Table 1
Illustration 5 g03673799
Key for switching to the next programming step
Setting Pause Time - (P1) for hours and (P2) for minutes. To access the programming mode, press both buttons at the same time for 4 seconds
until (P1) appears in the display.
Table 2
Setting Hours (P1) When the two buttons are released, the current value will appear. Hour is indicated by a dot on the right-hand side. Press the
Key shown in Illustration 4 for setting the following hour functions:
Setting Minutes (P2)Press the key shown in Illustration 4 so that (P2) appears in the display. When releasing the button the current value will
appear. Minute is indicated by a dot on the left-hand side. Press the Key shown in Illustration 4 for setting the following minute functions:
Note: If hour (P1) is set to 00, the display will show a minimum pause time of 4 minutes.
Programming the output signal for both alarm relays (P4) The default setting on the printed circuit board for the alarm contacts is switching to
battery minus. Press the Key shown in Illustration 5 so that (P4) appears in the display.
When releasing the button the currently set value appears in the display. The factory set value is (NO), normally open contact. On a fault condition
the alarm contact will close.
By pressing the Key shown in Illustration 4 the external fault contact is modified by programming it as a (NC) normally closed contact. On a fault
condition the alarm contact will open.
(P5) Two options for signaling a fault condition with alarm relays (F1) and (F2). Press the Key shown in Illustration 5 so that (P5) appears in
the display.
(o1) Option 1 (P4) is set to the default of Normally Open. F1 relay contact
(F1) A pressure fault will cause the F1 contact to close and stay closed
(F2) A low-level fault or a pressure fault will cause the F2 contact to close and stay closed
(F1) Fault contact will close on a low-level fault and stay closed.
(F2) Fault contact will close on a pressure fault and stay closed.
(P6) When applying power to the pump it can be programmed to start with a pause time (SP) or to start with a lube cycle (SO).
Press the Key shown in Illustration 5 so that (P6) appears in the display. The currently set value will indicate if the cycle is to start with the pause
time (SP) or the lube cycle (SO).
The default setting for the pump is set to start with a pause time (SP), (Start Pause Time).
Press the Key shown in Illustration 4. Each time the pump is switched on, it will start with the lube cycle (SP), (Start Operation). After the first
lubricating time the preset pause time will be valid.
Completing the programming Press the Key shown in Illustration 5 until (P) is displayed.
Note: Always carry out the programming completely in order to save the new values.
Press the Key shown in Illustration 4 for additional lubrication, to complete the programming, and to save the entered parameters.
Note: If the key for additional lubrication is not pressed within 30 seconds, the changed parameters will not be saved and the previous
programming remains valid.
Note: After the programming is complete, check the parameter settings in the operation mode.