Fallas 3mx68hvea (Si12-102)
Fallas 3mx68hvea (Si12-102)
Fallas 3mx68hvea (Si12-102)
Display Transmitter
It displays the It sends signals to the indoor unit.
Open current settings.
the (In this illustration,
cover. each section is
shown with all its
displays ON for the
purpose of
explanation. Some
models may not
show all its
indications.) C ON TEMPERATURE/TIME
adjustment buttons
It changes the temperature
POWERFULL button AMPM AMPM setting.
ON/OFF button
Press it once to start operation.
MODE selector button ON/OFF To stop it, press it once again.
POWERFULL TEMP
It selects the operation mode.
<FTK> <FTX>
FAN setting button
: DRY : AUTO It selects the air flow rate
: COOL : DRY setting.
MODE FAN SWING
: FAN : COOL SWING button
-SLEEP SENSOR
: HEAT
2. Press the timer cancel button repeatedly until a continuous beep is produced.
The code indication changes in the sequence shown below, and notifies with along beep
.
No. Code No. Code No. Code
1 00 11 E7 21 UA
2 U4 12 C7 22 A5
3 F3 13 H8 23 J9
4 E6 14 J3 24 E8
5 L5 15 A3 25 P4
6 A6 16 A1 26 L3
7 E5 17 C4 27 L4
8 LC 18 C5 28 H6
9 C9 19 H9 29 H7
10 U0 20 J6 30 U2
Note: 1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the timer cancel button down for 5 seconds. The code display also
cancels itself if the button is not pressed for 1 minute.
2. Press the timer cancel button repeatedly until a continuous beep is produced.
The code indication changes in the sequence shown below, and notifies with a long beep.
Note: 1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the timer cancel button down for 5 seconds. The code display also
cancels itself if the button is not pressed for 1 minute.
U0 Insufficient gas
A3 Faulty drainage
A5 Operation halt due to the freeze protection function or high pressure control
H8 CT or related abnormality
E0 Protectors Function
5. Troubleshooting
5.1 Indoor Units
5 5
5 5 A5 Operation halt due to the freeze protection function or high pressure 119
control (heat pump model only)
5 5
5 5 A6 Faulty fan motor (AC motor stop) AC motor 120
5 5
5 5 C4 or C5 Heat exchanger temperature thermistor or related abnormality 121
5 5
5 5 C9 Suction thermistor or related abnormality 121
5 4 123
5 1 U5 Signal transmission error (between indoor unit and remote controller) 128
A5 Operation halt due to the freeze protection function or high pressure 119
control
A6 Faulty fan motor (DC motor stop) DC motor 120
Note: 1. The indications in the parenthesis ( ) in the remote controller display column are displayed only when
system-down occurs.
2. When a sensor error occurs, check the remote controller display to determine which sensor is
malfunctioning.
If the remote controller does not indicate the error type, conduct the following operation.
*Turn the power switch off and back on again. If the same LED indication appears again immediately
after the power is turned on, the fault is in the thermistor.
*If the above condition does not result, the fault is in the CT.
3. The indoor unit error indication may take the precedence in the remote controller display.