AXIAL FAN SERIES
ADTA » ADTA-F » ADB » ADTA-RD
NICOTRA|Gebhardt
eeeL
fan|tastic solutionsNICOTRA|Gebhardt
Table of Content
1.
Nicotra Gebhardt Axial Fan Introduction
ADTA Series.
ADTA-F Series.
ADTA, ADTA - F General Dimension
ADTA, ADTA - F Exploded View
ADB Series
ADB General Dimension
ADB Exploded View
ADTA- RD Series
ADTA - RD General Dimension
ADTA - RD Exploded View
Products Range
Nomenclature
Appendix
Note
10
W
12
13
14
15
16
le
18
19NICOTRA|Gebhardt
Introduction
The Nicotra Gebharct axial fn provide wide range of air volume from 960 mthr to
216,000 m%/nr, at static pressure up to 1000 Pa of complete fan system with most
diversified application, Remarkably high fan efficiencies are the direct result of rigor-
ously developed aerodynamically profiled impeller blades and advanced manufacturing
technique.
FEATURES
« High Efficiency
+ Fully Adjustable Blade
« Versatile
* High Quality Material
* Interchangeable Components
* The Axial Impeller Is Balanced In Line
» Robust Construction
* GRIN and Pressure Die Cast Alumin
+ Anti-static GRN for Anti Spark Applicat
+ Third Party Certification On BS 7346 patNICOTRA|Gebhardt
Test Standard
The performances shown are for Standard units. Fans are tested in accordance to
Method 1, BS 848 Part 1; 1980, Under this standard, test results are corrected to
standard air density of 1.2kg/m?.
Any variation in individual fan performance due to manufacturing variations falls with
Class 8 tolerances of the British Standard. Fan sound levels are given on Perfor-
mance Curves together with Octave Band spectrum, based on in-duct method as
specified in BS 848 Part 2.
Impeller
Aerofoil blades are available in Three types of material. They are Glass Reinforced
Nylon (GRIN), Aluminium (AL) and Anti-static GRN (ASTAT).
GRN, Glass Reinforced Nylon
Glass reinforced Nylon 66 has greater strength and high temperature capability
(40°C to +150°C of non-radiant heat). Higher speeds are acceptable for standard
impeller when GRN blades are fitted. Recommended maximum Tip Speed for GRN is
115m/sec.
Aluminium, AL
Blades are available in Aluminium LM6. Proven for use in emergency smoke and fume
extract applications up te 400°C. It is also suitable for continuous operation -40°C to
+200°C. Maximum Tip Speed for AL blades is 100m/sec.
Anti-static Blades
GRN Blades specially formulated to provide anti-static properties are available. The
principle application for these blades is for installation which is categorised as “potentially
explosive atmosphere" and where the risk of ignition of gas or dust vapours through a
spark incident is a possibility.
These anti-static blades which are made with 20% glass filling (as standard) have a
Percentage of carbon black added to control the surface resistivity.
The anti-static blades have a slightly lower tensile strength than the normal GRN
blades, this should not concern mest applications, however we are recommending that
the max continuous operating temperature in limited to -30 degC to 110 degC.NICOTRA|Gebhardt
Balancing
All Nicotra Gebhardt axial impellers and fans are balanced to ISO Std No 1940, Edi-
tion using balancing grade of G2.5 (Displacement Amplitude = 2,5 mm/s) in our
factory.
Hub System
‘Our range of axial fan is fully adjustable blades and there are basically 6 hubs systems
as shown below:
Hub Size Number of Blades
110 5 Blades
160 5 & 10 Blades
230 3,6 & 12 Blades
250 3,68 12 Blades
400 4,8, 12 & 16 Blades
550 4,7 & 11 Blades
Hub Combination for Axial Fan
The complete hub system for impeller 1400 and 1600 consists of side plate metal,
center hub, aluminium blade, blade holder and taper lock bush.
Qur 250 and 400 hub are designed to be mounted with taper-lock bush 2517 of
42mm, 48mm, 55mm and 60mm diameter as optional feature.
Blades Design / Types
Basically, we have the following design of impellers:
Design Type Material Hub System
8 GRNYAnti-Static GRN 110, 160, 230
5 ALU 110, 160, 230
A GRN/ALU/Anti-Static GAN 110, 160, 230
T ALU 250
c ALU 400
Casing
All standard axial fan tube casing’s surface are applied with paint - RAL 7030 by
powder coating method. Coating thickness is 60um.
Thus, by this method, tube casing surface appeared to be wrinkle and provide better
prectection against chemical and wear.NICOTRA|Gebhardt
Long case axial casings are rolled from 2.0 mm to 5.0 mm mild steel. The standard
double flanged L bracket mounting is provided, foot mounted support can be provided
as optional. Tube casing come with standard view port, and the access door can be
requested as option
Electric Motor
Nicotra Gebhardt use standard three phrase motors TEFC, foot mounted insulation in
accordance with IEC standard EN 60034 or 8S 4999, Enclosure IPSS, insulation Class
“F, Other medium temperatures, protection classes, two speed motor (poles switch)
and etc as optional.
Computer selection
‘Our user-friendly fan selection software allows you to select the most suitable model
to your needs. Performance data and fan curve will be generated by the state of art
software.
Reversal of Air Flow
Air flow direction can be reversed on fans fitted with three-phased motors by simply
reversing the direction of rotation. But the impact on performance in reverse rotation is
approximately;
Airflow / volume: — -40%
Pressure reduction: -50%
Power reduction: -35%
Truly reversible
For a truly reversible axial fan, every other blade must be set in the opposite direction of
flow. The blades must be the same handing. The impact on performance in reverse rota-
tion is approximately: (applicable tor up to max pitch angle of 30 deg).
Airflow / volume; — -20%
Pressure reduction: -35%
Power reduction: — -30%
Contra-rotating
Multi-stage axial fans with contra-rotating impellers can be supplied as optional. A two
stage contra-rotating assembly develops approximately 2.5 times the pressure devel-
‘oped by a single stage fan and increases the overall sound level by 8-10 dB.NICOTRA|Gebhardt
To select @ contra-rotating axial. divide the static pressure by 2.5 and select as
though it was a single stage unit. The kW figure is for one stage only and should be
multiply by two to the system.
a Ge
Casing Overview Dimension
OO
0815-0560 0630-1600(sF5200) 1120-1600(>FS200)
Standard Arrangement
A = From the motor to the impeller
8 = From the impeller to the motor
AU = From the motor to the impeller, up position.NICOTRA|Gebhardt
ADTA Series
APPLICATION
Nicotra Gebhardt ADTA are particularly sult-
able for the extraction of stale air, for general
ventilation, drying process and all those
applications which require moving large
volumes of air.
CONSTRUCTION
The housing is made of heavy-gauge mild
steel casing, seamless double flanges at
both end. Powder coated bake enamel
finishing (60 micron) or galvanized steel
igh efficiency impeller made of adjustable
pitch aerofoil blade: ALU type or GN type.
Foot mounting & Hot dip galvanized casing
is available as an option
WORKING TEMPERATURE
-40°C to 150°C : GRN
-40°C to 200°C : ALU
MOTOR
Three-phase with type of "Totally Enclosed Fan Cooled” (TEFC), horizontal faot mounted
‘Squirrel Gage Induction Motor, featured with class F insulation system with Class B tem-
perature rise (80°C). Voltage supply includes 400W/50Hz, 400V/E0Hz or 440V/60Hz.
Motor Standards are comply with IEC 60034 or BS 4999. Other requirements upon
demand basis.
Motor are wired to an extemal terminal box with cable and through PVG or steel flexible
conduit. Please refer to page 17 Appendix for wire connection diagram.
DIRECTION OF THE AIR
The standard air flow from the impeller to the motor (8), on demand the fans ean be
supplied with the direction from the motor to the impeller (A).___________ NICOTRA|Gebhardt
ADTA - F Series
APPLICATION
Nicotra Gebhardt ADTA - F smoke spill axial
fans are particularly designed for the
removal of hot toxic smoke so as to remove
the smoke at the escape passage and assist
firefighters by providing better visibility. It
also provide ventilation to the area during
normal situation.
CONSTRUCTION
The housing is made of heavy-gauge mild
steel casing, seamless double flanges at
both end. Powder coated bake enamel
finishing or galvanized steel. High efficiency
impeller made of adjustable pitch aerotoil
blade pressure die cast Aluminium. Hot dip
galvanized casing is available as option
MOTOR
High temperature resistance motor compliance to BS 7346 : Part2 : 1980 and EN
12101-3 : 2006 directive. Three phase with type of “Totally Enclosed Air Over” (TEAQ),
horizontal foot mounted Squirrel Gage Induction Motor, featured with class H insulation
system with Class B temperature rise (80°C). Voltage supply includes 400V/S0Hz,
400W/60Hz or 440V/60Hz, Motor Standards are comply with IEC 60034 or BS 4999.
Other requirements upon demand basis.
Motor are wired to an external terminal box with cable and through flexible conduit.
Please refer to page 17 Appendix for wire connection diagram.
TESTING
ADTA - F axial fans have been tested by the Warrington Fire Research which is UK's
largest Independent specialist in fire safety testing, consultancy and research. Its
report are well accepted by specifying and regulatory authorities throughout the
world.
This series were tested in accordance to BS 7346 : Part 2 : 1990 Class B (250°C, 120
minutes) and equivalent to EN 12101-3 : 2006 (F200)
DIRECTION OF THE AIR
The standard air flow from the impeller to the motor (B}, on demand the fans can be
supplied with the direction from the motor to the impeller (A)NICOTRA|Gebhardt
ADTA, ADTA - F General Dimension
ADTA /- F with Hanger
won es re wren
OM se ea a mse ®
«8 oh coo ie ae ®
2 8 mie @ 9 We 40 48 a
a we mee m
oS os Moo aims oy
m0 me maine ome atm 12
OM He oe ses a =
m0 mom ee *
me of re eT me
m imo aN ge mE a
mm ‘oe WEAK ED a
rea aoe a oe et a
a) feo oat dee =
rm so) a oe at
tm am mmo te0 me we moms ieee =
Dus te. poley ot cantinucus development and improvement the nght ie tesarves to supply procuet winch may ies rem thoes:
fnustiated anc deseibedl in thie publicasons
Cartiad dimensione wil be supplad on receipt of orderNICOTRA|Gebhardt
ADTA, ADTA - F Exploded View
Part List, Specification, Arrangement
Part Description Specification
4 Tube Casing Painted (RAL 7030), Hol Dipped, Stainless Stea!, ete
2 Terminal Box Pvc, Cast ron, ote
3 Viewpor Gover Depend on tasing material
4 Mouting Feet (Optional) Depend on teasing mater
& Counter Fiange (Optional) Depend on teasing material
& Electrical Mater ‘Specification as per requested
7 Impaler ALU, GRN, GRN-antistatic
& Fan Guard Painted or Hot Dipped
MODEL BA OBIFCOL DO oNxe
315 35 4 akin
ss m5 a axio
300 20 4 12x10
0 20 401K
00 540 41K
360 oe 1K
ry ers 1K
ro 758 a exe
ooo 8s 4 tex
soo 948 1x12
1000 ios eK
129 116 so aK
1250 108 eo aK
i400 1985, eo SEK ta
1800 168 fo extNICOTRA|Gebhardt
ADB General Dimension
|
ag |=
|
u a
‘ADB GENERAL DIMENSIONS:
MODEL BA GB /PCD) ee D E F Ho Nx® Px® Mu F.Size
a0 0 Mab tae 88 tO aD ONS
a0 90 SM tg ae DOOL
soo 500 SMD SBD 5B MK xt DOL
a ee
6D BAPE IDK ID Date OTM
mo 7 10H BFF BX xB ONT
oO SOBRE HK TZ nts OOM
0 451000 SBN AZ HB OTE
O00 1100 SSDS 24K 12 NNR DIEM
101085125) 1100 9854S BANE 2x8 DBES
j20 1818198014110 10 wR 24K ae DeSM
icy of cortewaus davleomantse imerovenartthe rghtisrasacved t supply product which may er em thaws
snd Sesrbed vhs pubeaions " "ive "
CCertfed dimaneicne wit be sunpliad! en receipt ef order
"NICOTRA|Gebhardt
ADB Exploded View
Part List, Specification, Arrangement
Part Description ‘Specification
1 Tube Casing Hot Dipped, Optional povrder coated
2 Electrical Mator ‘Specification as per requested
2 Mouting Feet Hot Dipped
4 Extended Shaft ‘Steel C45,
5 impeller
ALU, GRN, GRN-aniistaticType ARTA - RD
APPLICATION
Nicotra Gebhardt ARTA - AD are particularly
suitable for the roof extraction of stale air, for
general ventilation, and all those applications
which require moving large volumes of air and
limited tenure space, especially factory, Hyper-
market and etc.
CONSTRUCTION
The housing is made of heavy-gauge mild
steel casing, seamless double flanges at both
end. Powder coated bake enamel finishing (60
micron) or galvanized steel. High efficiency
impeller made of adjustable pitch aerofoil
blades, ALU type or GRN type. Cylindrical
stack with plate square base or facing on to
horizontal base, or tilted to suit the roof pitch.
Rain hood as protection against adverse
outdoor weather condition.
WORKING TEMPERATURE
-40°C to 150°C : GRN
-40°C to 200°C : ALU
MOTOR
NICOTRA|Gebhardt
SS
Three-phase with type of “Totally Enclosed Fan Cooled” (TEFC), horizontal foot mounted
‘Squire! Cage induction Motor, featured with class F insulation system with Class B tempera-
ture rise (80°C). Voltage supply includes 400V/S0Hz, 400V/60Hz or 440W/60Hz, Motor Stan-
dards are comply with IEC 60034 or BS 4999. Other requirements upon demand basis.
Motor are wired to an external terminal box with cable and through PVC or steel flexible con-
duit, Please reter to page 17 Appendix for wire connection diagram.
DIRECTION OF THE AIR
‘The standard air flow from the motor to impeller (A).
13NICOTRA|Gebhardt
ADTA - RD General Dimension
yoneL E F
4 ato 500m
30 as a5 en
neo 1720 700
oo 1320 708
2501280 7
2801280 700
apeneagege
120
1800
1980
1850
Miers
BRERESERaee
Duet 2 poy of contnaovs deste andineroverent the ight reserved 9 supply product which may lifer fom those
fast "desorbed in the publewors
Caries cimensione willbe sunplad on raceinto order
4NICOTRA|Gebhardt
ADTA - RD Exploded View
15
Part List, Specification, Arrangement
Neosens
Part Description
Rain Hood
Impeller
Electric Motor
Tube Casing
Terminal Box
Viewport Cover
Fan support Base
‘Specification
Fiber Glass
ALU, GRN, GRN-antistatio
‘Specification as per requested
Painted (RAL 7030}, Hot Dipped, Stainless Steel, ete
PVE, Cast Iron, ete
(Depend on veasing material
Depend on teasing materialNICOTRA|Gebhardt
Aerodynamic Performance
The Emergency Fume and Smoke Extract Fan range is tested in accordance with BS
848 Part 1, and the data shown is determined under normal ambient conditions as a
standard basis for unit selection.
, Fan Performance Curves
058 bene
ae
oe isa STS es
oes ee ete ae an |
a TE eT
oun ae
on Fan Performance Curves. sg
Dia mm Cn |.
0 315- 630 @ 2800 rpm Deanne fo
woo] 7] 315 - 1250 @ 1400 rpm wale Day
a0
i
2 3
am fs
ie i
Foc os
3 of 03
TFT aT ae OF TST Tite
amas isa 4 66 tiea 40 ab teu ieo (iia
Dimensions and performance graphs detailed inthis lesiet are to be used only as a guide. Certified information is
available on request from our Sales Office, Note: Data above 1260mm shall be provided on request
168NICOTRA|Gebhardt
Nomenclature
When ordering Nicotra Gebhardt Axial fans, please specify your requirements in the
followings sequence to avoid contusion.
1. Fan Type and Performance Data
~ Fan Type: ADT, ADF, ADB or ARD
~ Capacity
~ Static Pressure
2. Electric Motor Details
~ Power, main supply, voltage, frequency, 50 Hz or 60 Hz type
~ Motor Speed, Polarity
~ Insulation (Class F, Class H, etc)
3, Impeller Material
~ Glass Reinforced Nylon, GRN
+ Aluminium, ALU
+ Anti Static GRN
[ ] [ [ [ J ‘TT
Bade Matos! Moto Bowonoiet
Blas Ange
Fan Ty an Dinar L HUB Se No of Blades ond Type
Description (Sample)
ADF 1000/400/08C/20.0/ALU-18.5/4P
ADT Long Case Drive
1000 Fan Diameter = 1000mm
400T Hub Size
ac Blade type "C", Qty = 8
20° Blade Angle 20 Deg
ALU ALU Material
7NICOTRA|Gebhardt
Appendix
Wiring Diagram For Various Application
ut ie 13 uu \2 uu
Star Connestion Delta Connection
mks
Star-Delta Connection
‘Multispeed motors in Dahlander
Connection (tapped winding)
boo os oo ow oO
Low Speed High Speed
Multi-speed with 2 separate Windingds
uo ob
Low Speed High Speed
18NICOTRA|GebhardtNICOTRA|Gebhardt
‘gaa 4a-O5705 209 990
eeshe Sap one aot 3 68
Eat ninmy.crantt oe
SWEDEN
aoe 2a7
inkstnpagtan 39
S123 Mato
“Fegisne co 46-37-87 48 40
Fiecie eo ab-a-87 a8
Eat gootunpayethen
niger
‘@REAT BATA
[82 6.0 Methane
‘onsaeoua
PasgateBeress Pak
‘eens saa. 706 700700
Jeane Some seamee
Mal bsietaco
‘io
ents Nos
‘smal
onic
Bel
“Taegtone 4 u70 00 sear
Jeetae Yaa gro 009 2012
Mal boast cok
‘tet so
Nicotia Gebhardt Sp.
va Modena, 18
Nicotra Gebhardt GmbH
Gabhamisesse 19:25
2ADAD Cinetana -Lac. Zingania (BG) lily PANE Wadenburg. Germany
Blephone +30 038473 111
Blin 39 caS 64 319
Emal — iinigncotrat
ewnunicate- goctiardt com
MINAS
Lo 709, lan Bohn, Kanenan Pst
Bika Bebe, a0 Se Korg, Skee
Bans esr
Taophenn -S-gape 288
Taokac Gap 1680/52
Fs i: maaan acm
Haan
foo a
aoa Eons 2
onsen
Sore
Tenphon -omo 761003.
Thekac--EEE S162
Ent salesdinecnagethardtonmn
SINGAPORE
Hin fe Cone er
(£04.08 Paes Paryany Buby
Terpoe oases 1222
Teas OEE) eces 2400
Ent niedyebhee-ergpore.cum
Blephone 4.40 (9742 101 0
Bieiax +49 (0/7942 101 170
EMail nioiigstharctde
enmunicotre-georaedt com
AASTRAUA
‘es rinome Epa
‘we 30ms uma
“Flee 65-9000 79500 9012595
Hloka Ser onan sae 3019909
Eat ostream ms
vwonuriestr
‘soa
Fo 1 a
1808 My ExcomCe
ayo, UT ema?
“Fiegtoew 201 6095440800
Bee omens oe
ete oor BD
Eh) Setar cin