www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.8.

8
Company: PT QUADRAN EMPAT PERSADA Page: 1
Specifier: Project: MINING ESCAVATION
Address: Fastening Point: Combat 42m Medium
Phone I Fax: | Date: 28/05/2022
E-Mail:

Specifier's comments:

1 Input data
Anchor type and size: HIT-RE 500 V3 + HAS-U 5.8 M16
Effective embedment depth: hef,act = 100 mm (hef,limit = - mm)
Material: 5.8
Approval No.: ESR-3814
Issued I Valid: 01/01/2019 | 01/01/2021
Proof: Design method ACI 318-11 / Chem
Stand-off installation: eb = 0 mm (no stand-off); t = 10 mm
Baseplate: lx x ly x t = 580 mm x 580 mm x 10 mm; (Recommended plate thickness: not calculated
Profile: Square hollow, 100 x 100 x 3,6; (L x W x T) = 100 mm x 100 mm x 4 mm
Base material: cracked concrete, C30/37, fc' = 4,351 psi; h = 400 mm, Temp. short/long: 30/30 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar

R
- The anchor calculation is based on a rigid baseplate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.8.8
Company: PT QUADRAN EMPAT PERSADA Page: 2
Specifier: Project: MINING ESCAVATION
Address: Fastening Point: Combat 42m Medium
Phone I Fax: | Date: 28/05/2022
E-Mail:

2 Load case/Resulting anchor forces y


3 4
Load case: Design loads

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 10.973 0.496 0.110 0.484
2 10.973 0.496 0.110 0.484 x
3 10.973 0.496 0.110 0.484 Tension
4 10.973 0.496 0.110 0.484

max. concrete compressive strain: - [‰]


max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/0): 43.892 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN] 1 2
Anchor forces are calculated based on the assumption of a rigid baseplate.

3 Tension load
Load Nua [kN] Capacity f Nn [kN] Utilisation bN = Nua/f Nn Status
Steel failure* 10.973 51.025 22 OK
Bond failure** 43.892 123.555 36 OK
Sustained Tension Load Bond Strength* N/A N/A N/A N/A
Concrete cone failure** 43.892 101.312 44 OK
* most unfavourable anchor **anchor group (anchors in tension)

3.1 Steel failure


Nsa = ESR value refer to ICC-ES ESR-3814
f Nsa ≥ Nua ACI 318-11 Table D.4.1.1

Variables
Ase,N [mm2] futa [N/mm2]
157 500.00
Calculations
Nsa [kN]
78.500
Results
Nsa [kN] f steel f Nsa [kN] Nua [kN]
78.500 0.650 51.025 10.973

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.8.8
Company: PT QUADRAN EMPAT PERSADA Page: 3
Specifier: Project: MINING ESCAVATION
Address: Fastening Point: Combat 42m Medium
Phone I Fax: | Date: 28/05/2022
E-Mail:

3.2 Bond failure

Nag = (AA ) y
Na
Na0
ec1,Na y ec2,Na y ed,Na y cp,Na Nba ACI 318-11 Eq. (D-19)
f Nag ≥ Nua ACI 318-11 Table D.4.1.1
ANa = see ACI 318-11, Part D.5.5.1, Fig. RD.5.5.1(b)
ANa0 = (2 cNa)2 ACI 318-11 Eq. (D-20)
cNa = 10 da √ t uncr
1100
ACI 318-11 Eq. (D-21)

( )
1
y ec,Na = e' ≤ 1.0 ACI 318-11 Eq. (D-23)
1+ N
cNa
y ed,Na = 0.7 + 0.3 ( ) ca,min
cNa
≤ 1.0 ACI 318-11 Eq. (D-25)

y cp,Na = MAX ( )
ca,min cNa
,
cac cac
≤ 1.0 ACI 318-11 Eq. (D-27)
Nba = l a · t k,c · p · da · hef ACI 318-11 Eq. (D-22)

Variables
2 2
t k,c,uncr [N/mm ] da [mm] hef [mm] ca,min [mm] aoverhead t k,c [N/mm ]
17.46 16 100 465 1.000 9.45
ec1,N [mm] ec2,N [mm] cac [mm] la
0 0 159 1.000
Calculations
cNa [mm] ANa [mm2] ANa0 [mm2] y ed,Na
242 934,389 233,597 1.000
y ec1,Na y ec2,Na y cp,Na Nba [kN]
1.000 1.000 1.000 47.521
Results
Nag [kN] f bond f Nag [kN] Nua [kN]
190.085 0.650 123.555 43.892

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.8.8
Company: PT QUADRAN EMPAT PERSADA Page: 4
Specifier: Project: MINING ESCAVATION
Address: Fastening Point: Combat 42m Medium
Phone I Fax: | Date: 28/05/2022
E-Mail:

3.3 Concrete cone failure

Ncbg = (AA ) y
Nc
Nc0
ec,N y ed,N y c,N y cp,N Nb ACI 318-11 Eq. (D-4)
f Ncbg ≥ Nua ACI 318-11 Table D.4.1.1
ANc see ACI 318-11, Part D.5.2.1, Fig. RD.5.2.1(b)
ANc0 = 9 h2ef ACI 318-11 Eq. (D-5)

( )
1
y ec,N = 2 e'N ≤ 1.0 ACI 318-11 Eq. (D-8)
1+
3 hef
y ed,N = 0.7 + 0.3 (
ca,min
1.5hef )
≤ 1.0 ACI 318-11 Eq. (D-10)

y cp,N = MAX (
ca,min 1.5hef
cac
,
cac )
≤ 1.0 ACI 318-11 Eq. (D-12)
1.5
Nb = kc l a √fc hef
'
ACI 318-11 Eq. (D-6)

Variables
hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm] y c,N
100 0 0 465 1.000

cac [mm] kc la f'c [psi]


159 17 1.000 4,351

Calculations
ANc [mm2] ANc0 [mm2] y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
360,000 90,000 1.000 1.000 1.000 1.000 38.966
Results
Ncbg [kN] f concrete f Ncbg [kN] Nua [kN]
155.864 0.650 101.312 43.892

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.8.8
Company: PT QUADRAN EMPAT PERSADA Page: 5
Specifier: Project: MINING ESCAVATION
Address: Fastening Point: Combat 42m Medium
Phone I Fax: | Date: 28/05/2022
E-Mail:

4 Shear load
Load Vua [kN] Capacity f Vn [kN] Utilisation bV = Vua/f Vn Status
Steel failure* 0.496 28.200 2 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout failure (concrete cone relevant)** 1.985 218.210 1 OK
Concrete edge failure in direction y+** 1.985 112.138 2 OK
* most unfavourable anchor **anchor group (relevant anchors)

4.1 Steel failure


Vsa = ESR value refer to ICC-ES ESR-3814
f Vsteel ≥ Vua ACI 318-11 Table D.4.1.1

Variables
Ase,V [mm2] futa [N/mm2]
157 500.00
Calculations
Vsa [kN]
47.000
Results
Vsa [kN] f steel f Vsa [kN] Vua [kN]
47.000 0.600 28.200 0.496

4.2 Pryout failure (concrete cone relevant)

Vcpg = kcp [(AA ) y


Nc
Nc0
ec,N ]
y ed,N y c,N y cp,N Nb ACI 318-11 Eq. (D-41)
f Vcpg ≥ Vua ACI 318-11 Table D.4.1.1
ANc see ACI 318-11, Part D.5.2.1, Fig. RD.5.2.1(b)
ANc0 = 9 h2ef ACI 318-11 Eq. (D-5)

( )
1
y ec,N = 2 e'N ≤ 1.0 ACI 318-11 Eq. (D-8)
1+
3 hef
y ed,N = 0.7 + 0.3 (
ca,min
1.5hef )
≤ 1.0 ACI 318-11 Eq. (D-10)

y cp,N = MAX (
ca,min 1.5hef
cac
,
cac )
≤ 1.0 ACI 318-11 Eq. (D-12)
1.5
Nb = kc l a √fc hef
'
ACI 318-11 Eq. (D-6)

Variables
kcp hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm]
2 100 0 0 465

y c,N cac [mm] kc la f'c [psi]


1.000 159 17 1.000 4,351

Calculations
ANc [mm2] ANc0 [mm2] y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
360,000 90,000 1.000 1.000 1.000 1.000 38.966
Results
Vcpg [kN] f concrete f Vcpg [kN] Vua [kN]
311.728 0.700 218.210 1.985

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.8.8
Company: PT QUADRAN EMPAT PERSADA Page: 6
Specifier: Project: MINING ESCAVATION
Address: Fastening Point: Combat 42m Medium
Phone I Fax: | Date: 28/05/2022
E-Mail:

4.3 Concrete edge failure in direction y+

Vcbg = (AA ) y
Vc
Vc0
ec,V y ed,V y c,V y h,V y parallel,V Vb ACI 318-11 Eq. (D-31)
f Vcbg ≥ Vua ACI 318-11 Table D.4.1.1
AVc see ACI 318-11, Part D.6.2.1, Fig. RD.6.2.1(b)
AVc0 = 4.5 c2a1 ACI 318-11 Eq. (D-32)

( )
1
y ec,V = 2e'v ≤ 1.0 ACI 318-11 Eq. (D-36)
1+
3ca1
y ed,V = 0.7 + 0.3 (ca2
1.5ca1 )
≤ 1.0 ACI 318-11 Eq. (D-38)

y h,V = √
1.5ca1
ha
≥ 1.0 ACI 318-11 Eq. (D-39)

(( ) )
0.2
l 1.5
Vb = 7 e √da l a √f'c ca1 ACI 318-11 Eq. (D-33)
da

Variables
ca1 [mm] ca2 [mm] ecV [mm] y c,V ha [mm]
592 465 0 1.000 400

le [mm] la da [mm] f'c [psi] y parallel,V


100 1.000 16 4,351 1.000

Calculations
AVc [mm2] AVc0 [mm2] y ec,V y ed,V y h,V Vb [kN]
747,600 1,577,088 1.000 0.857 1.490 264.628
Results
Vcbg [kN] f concrete f Vcbg [kN] Vua [kN]
160.197 0.700 112.138 1.985

5 Combined tension and shear loads


bN bV z Utilisation bN,V [%] Status
0.433 0.018 5/3 25 OK
bNV = bzN + bzV <= 1

6 Warnings
• The anchor design methods in PROFIS Anchor require rigid baseplates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the baseplate are not considered - the baseplate is assumed to
be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required
baseplate thickness with FEM to limit the stress of the baseplate based on the assumptions explained above. The proof if the rigid baseplate
assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions
and for plausibility! 
• Condition A applies when supplementary reinforcement is used. The Φ factor is increased for non-steel Design Strengths except Pullout
Strength and Pryout Strength.

Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout
Strength.

Refer to your local standard.


• Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the
Evaluation Service Report for cleaning and installation instructions.
• Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant
standard!
• Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-11,
Part D.9.1

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.8.8
Company: PT QUADRAN EMPAT PERSADA Page: 7
Specifier: Project: MINING ESCAVATION
Address: Fastening Point: Combat 42m Medium
Phone I Fax: | Date: 28/05/2022
E-Mail:

7 Installation data
Baseplate, steel: - Anchor type and size: HIT-RE 500 V3 + HAS-U 5.8 M16
Profile: Square hollow, 100 x 100 x 3,6; (L x W x T) = 100 mm x 100 Installation torque: 0.080 kNm
mm x 4 mm
Hole diameter in the fixture: df = 18 mm Hole diameter in the base material: 18 mm
Plate thickness (input): 10 mm Hole depth in the base material: 100 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 136 mm
Drilling method: Hammer drilled
Cleaning: Compressed air cleaning of the drilled hole according to
instructions for use is required

7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • Dispenser including cassette and mixer
• Properly sized drill bit accessories to blow from the bottom of • Torque wrench
the hole
• Proper diameter wire brush
y

290 290

32
3 4

290
516

x
290

1 2
32

32 516 32

Coordinates Anchor mm
Anchor x y c-x c+x c-y c+y
1 -258 -258 465 - 592 1,108
2 258 -258 981 - 592 1,108
3 -258 258 465 - 1,108 592
4 258 258 981 - 1,108 592

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.8.8
Company: PT QUADRAN EMPAT PERSADA Page: 8
Specifier: Project: MINING ESCAVATION
Address: Fastening Point: Combat 42m Medium
Phone I Fax: | Date: 28/05/2022
E-Mail:

8 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like