1 2 3 4 5 6 7 8 9 10

1. ALL DIMENSIONS ARE IN FEET & INCHES, UNLESS OTHERWISE


SPECIFIED.
2. DRAWING SHOULD NOT BE SCALED, FOLLOW FIGURED DIMENSIONS.
31'-3" 3. ANY DISCREPANCY IN DRAWING SHALL BE BRING TO NOTICE OF
F N STRUCTURAL CONSULTANT BEFORE EXECUTION OF WORK. F
4. THIS DRAWING SHOULD BE READ ALONG WITH THE RELEVANT
W1 W1 W1 ARCHITECTURAL DRAWING.
3 5. IF THERE IS ANY REVISION IN DRAWING, FURTHER CONSTRUCTION
SHALL BE EXECUTED AS PER THE LATEST REVISED DRAWING, ON THE
NOTE:
ISSUE OF LATEST REVISION.
6. GRADE OF CONCRETE SHALL BE M20.GRADE OF STEEL SHALL BE Fe500
1. PROVIDE DISTRIBUTION RIENF. 8 @ 8"c/c 7. CLEAR COVER FOR
FOOTING :2"(50mm)
11'-9" S1 S3 3 "(30mm)
S3 PLINTH BEAM :1 16
2. BOTTOM ROD

W1
COLUMN :1 1/2"(40mm)

W1
3. TOP ROD BEAM :1"(25mm)
SLAB :3/4"(20mm)
8. LAP LENGTH OF BARS : 50Ø, AT COLUMN LAPPING PROVIDE 4"
D1 D1 D1 SPACING OF TIES, NO LAPPING ALLOWED AT BEAM-COLUMN JOINT.
2 9. DEVELOPMENT LENGTH (Ld) FOR REINFORCEMENT BARS
E IN COMPRESSION : 40Ø E

28'
IN TENSION : 50Ø
10. IN CASE OF BEAM REINFORCEMENT, NO LAPPING SHALL BE ALLOWED
3' 3' B/5 B/10 IN FOLLOWING PLACES

1'-3"
(a) TOP ROD NEAR COLUMN, L/4 ON EITHER SIDES OF COLUMN
(b) TOP ROD OF CANTILEVER BEAM ALONG THE LENGTH AND
D1
3' B/3 B/10

c
W1
16'-3"

ALSO DEVELOPMENT LENGTH, BEYOND COLUMN


S2
(c) BOTTOM ROD AT MID SPAN OF BEAM

c/3
S3

c/5

3'
11. REMOVAL OF SHUTTERING / FORM WORK
℄ (a) COLUMN : 24 HOURS

b/5
(b) BEAM SIDES : 24 HOURS

b/3

3'
W1
(c) BEAM BOTTOM : LESS THAN 6M SPAN : 14 DAYS
3' : MORE THAN 6M SPAN: 28 DAYS

1'-3"
(d) SLAB : LESS THAN 20'SPAN : 14 DAYS

b
W1 : MORE THAN 20'SPAN : 28 DAYS

b/3
1 MD

b/5
W1 HOWEVER 7 DAYS STRENGTH OF CONCRETE SHOULD BE 65% OF THE
℄ TARGET STRENGTH, TO REMOVE FORM WORK.
D 12. THIS BUILDING IS DESIGNED FOR GROUND FLOOR. D

a/5
B/10

a/3
3' B/3
3'

a
UP
3' 3' B/5 B/10

1'-3"
22'-1012"

a/10

a/10

3'
8'-9"

A B1'-3"
℄ ℄ ℄
TERRACE FLOOR SLAB LAYOUT
TYPICAL ONE WAY SLAB REINFORCEMENT DETAILING
LINTEL BEAM TO DETAIL
Y8@8"c/c
2Y10 Y8@5"c/c
C C
6"

3"

9" 2Y109" REV NO Date REVISION REMARKS

3'

CONTRACTOR
TYPICAL SECTION OF LOFT / LINTEL
CUM SUNSHADE DETAILS
b

b/3

b/3

b/3
b/5

b/5

b/5
B CLIENT B
a/5

a/5

a/5
a/3

a/3

a/3
SCHEDULE OF SLABS FIRST FLOOR SLAB LAYOUT & REINFORCEMENT
DETAIL
DETAILS
SLAB NO THICKNESS SHORTER SPAN LONGER SPAN A/10 A/5 B/3 B/5 C/3 C/10
REMARKS
REINFORCEMENT REINFORCEMENT Er.Y.BOOPATHI M.E(Struct), M.I.S.T.E,
a

LICENSED STRUCTURAL ENGINEER


S1 6" Y8@6"c/c Y8@8"c/c TWO WAY SLAB STRUCTURAL
A/10 A/3 B/5 B/3 C/5 C/10 PYRAMID STRUCTURAL CONSULTANT
CONSULTANT
Contact No : +91 9597691155
S2 6" Y10@6"c/c Y8@6"c/c TWO WAY SLAB
Mail id :pyramidstrconsultant@gmail.com
S3 6" Y12@6"c/c Y10@6"c/c TWO WAY SLAB Scale 1:100
a/10

a/10

a/10
a/10

a/10
a/10
DRAWN CHECKED APPROVED
A Date 16-06-2021 A
AS KR Y.BOOPATHI Paper A3
A B C Size
Rev.no R0
℄ ℄ ℄ ℄
DRAWING NO:- YB-210xx-ST-01
Sheet.no (01 OF 02)
TYPICAL TWO WAY SLAB REINFORCEMENT DETAILING
1 2 3 4 5 6 7 8 9 10