773D Off-Highway Truck NBJ00001-UP (MACHINE) POWERED BY 3412E Engine(S...

Page 1 of 3

Shutdown SIS

Previous Screen

Product: TRUCK
Model: 773D TRUCK NBJ
Configuration: 773D Off -Highway Truck NBJ00001 -UP (MACHINE)
POWERED BY 3412E Engine

Systems Operation
773D and 777D Off-Highway Truck/Tractors Caterpillar Monitoring System
Media Number -RENR8397-00 Publication Date -01/01/2007 Date Updated -24/01/2007

i02601299

Modes of Operation
SMCS - 7490

Illustration 1 g01302021
This is a typical example of the Display Area (Mode 2).

The Caterpillar Monitoring System has 15 different possible modes of operation. Five of the modes are
operator modes and seven of the modes are service modes. Each mode provides important information
regarding the condition of the machine. Each mode also provides information regarding the setup of the
monitoring system. All modes are not available on all machines. The system that is installed on the
machine determines the modes that are available. All 12 modes are given names and the modes are
referenced in this manual. The mode is shown as a number on each display area on the main display
module. This number is assigned by the software in the main display module.

The seven service modes can be changed by using the service switch and the clear switch on the main
display. The five operator modes are accessible by using the selector switch for the operator mode that is
located in the operator's compartment. The following table shows the available modes. See the
Operation and Maintenance Manual of the machine that is being serviced for specific information on the
operator mode.

When power is applied, the Caterpillar Monitoring System performs the self test. After the self test is

https://10.161.144.3/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 12/3/2008
773D Off-Highway Truck NBJ00001-UP (MACHINE) POWERED BY 3412E Engine(S... Page 2 of 3

complete the Caterpillar Monitoring System enters the Normal Mode. To enter the other modes, the
service and clear inputs are grounded at the same time. This action causes the mode numbers to scroll
sequentially on the six digit display area of the main display module. When ground is removed from the
service and clear inputs, the monitoring system enters the mode which corresponds to the number that is
presently shown. The following situation is an example. When you see the mode number "- 1-" on the
readout remove the ground. This action causes the monitoring system to enter harness code mode.

Note: The following situation will occur when the key start switch is in the ON position and the service
and clear inputs are grounded. The monitoring system performs the self test when the power is applied.
The mode numbers immediately scroll after the self test.

The service and clear inputs are provided with access by the service connector or the switch. The service
connector or the switches are located within the operator compartment. Information on the location of
the service connector is in the Electrical System Schematic for the machine that is being serviced.

The mode of operation is variable at any time. Grounding the service and clear inputs at the same time
initiates the scrolling of the mode numbers. Removing ground causes the monitoring system to enter the
operating mode. The mode number that is shown will correspond to the operating mode. When you are
scrolling through the modes, mode 0 (normal mode) is not shown on the display area as a number. When
you reach mode 0, the display area begins showing the information for mode 0 (normal mode).

Table 1

Off-Highway Trucks

Operator Modes
Operator Mode Mode Number

Service Meter 1

Odometer 2

Tachometer 3
Resettable Load Counter 4

Diagnostic Scrolling 5

Table 2

Off-Highway Trucks
Service Modes

Service Mode Mode Number

Operator Mode Sequence 0


Harness Code 1

https://10.161.144.3/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 12/3/2008
773D Off-Highway Truck NBJ00001-UP (MACHINE) POWERED BY 3412E Engine(S... Page 3 of 3

Numeric Readout 2

Service 3
Digital Tattletale 4

Units 5

Permanent Load Count 6

Calibration (Transmission Control) 7

Copyright 1993 - 2008 Caterpillar Inc. Wed Dec 3 10:43:52 UTC+0700 2008