Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

I5 BRIDGE DECK AS RC

The ultimate resistance moment of a flanged beam


may be taken as the lesser of the values given by
equations 6 and 7, where hf is the thickness of the
flange.
Where it is necessary for the resistance moment to
exceed the value given by equation 7, the section
should be analysed in accordance with 5.3.2.1.

As = Mu/ (0.87fy x ( d -hf/2 )

3 DESIGN OF I5 AS RC Page 1 of 12
Main Bars
Shear 5.3.3.2
Node Moment Force kNm Asa As
(LC) (kNm) (kN) Eq 6 Eq7 Cap (mm ) 2
Used
h 1115mm 0.299 79 210 190 2,965 263 453
hf 150mm 1.3 498 636 1,195 2,965 794 1,990
Cover 135mm 2.309 1,021 459 2,454 2,965 574 3,027
Dia. Bar 25mm 3.3 1,285 392 3,086 2,965 490 3,577
f
CU
40 N/mm 2
4.3 1,580 319 3,797 2,965 398 4,196
f
y
460 N/mm 2
5.3 1,751 228 4,207 2,965 285 4,492
b 1400mm 6.3 1,893 167 4,547 2,965 208 4,756
f
yv
460 N/mm 2
7.3 2,009 106 4,828 2,965 133 4,961
Area Full 4.82E-04 mm
2
7.807 2,021 11 4,855 2,965 14 4,870
d 957.5mm
Dia. Link 10mm d' 157.5mm Asa = 0.5V/(0.87f )
y

DESIGNERS MUST BE MINDFUL THAT CAMBER DURING AND AFTER CONSTRUCTION IS


ACCOUNTED . CAMBER IN SPAN ALSO REQUIRED

3 DESIGN OF I5 AS RC Page 2 of 12
From Total As :
0.299 1.3 2.309 3.3 4.3
Dia. Bar Dia. Bar Dia. Bar Dia. Bar Dia. Bar
Nos Nos Nos Nos Nos
(mm) (mm) (mm) (mm) (mm)
req req req req req

40 0 40 2 40 2 40 3 40 3
32 1 32 2 32 4 32 4 32 3
25 1 25 4 25 6 25 7 25 3
20 1 20 6 20 10 20 11 20 3
16 2 16 10 16 15 16 18 16 3
5.3 6.3 7.3 7.807
Dia. Bar Dia. Bar Dia. Bar Dia. Bar
Nos Nos Nos Nos
(mm) (mm) (mm) (mm)
req req req req

40 4 40 4 40 4 40 4
32 6 32 6 32 6 32 6
25 9 25 10 25 10 25 10
20 14 20 15 20 16 20 16
16 22 16 24 16 25 16 24

TO NOTE THAT CRACK WIDTHS WILL DETERMINE MINIMUM REINFORCEMENT

3 DESIGN OF I5 AS RC Page 3 of 12
SHEAR

3 DESIGN OF I5 AS RC Page 4 of 12
Assume that 10dia links are
used
then Sv
Minimum is 2T10@690
Other requirements govern

At 100As/bd vc V kN v 2d/av vc Sv Max Sv Sv


0.30 0.28 0.40 210 1.46 6.40 2.53 NA 100
1.30 1.25 0.65 636 4.43 1.47 0.95 108 225 100
2.31 1.90 0.75 459 3.20 1.00 0.75 147 225 140
3.30 2.25 0.79 392 2.73 1.00 0.79 179 225 175
4.30 2.64 0.83 319 2.22 1.00 0.83 234 225 225
5.30 2.82 0.85 228 1.59 1.00 0.85 368 225 225
6.30 2.99 0.87 167 1.16 1.00 0.87 604 225 225
7.30 3.12 0.88 106 0.74 1.00 0.88 1,601 225 225
7.81 3.06 0.87 11 0.08 1.00 0.87 NA 225 225

3 DESIGN OF I5 AS RC Page 5 of 12
Minimum area of reinforcement at the contact surface
should not be less than 0.15%
2 T10 @ 300. This can be combined with links that
are used in the web.

3 DESIGN OF I5 AS RC Page 6 of 12
3 DESIGN OF I5 AS RC Page 7 of 12
3 DESIGN OF I5 AS RC Page 8 of 12
3 DESIGN OF I5 AS RC Page 9 of 12
3 DESIGN OF I5 AS RC Page 10 of 12
3 DESIGN OF I5 AS RC Page 11 of 12
3 DESIGN OF I5 AS RC Page 12 of 12