Form 6 Recloser Control Product Aid Pa280009en

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

COOPER POWER

Form 6 recloser control SERIES

Maximum functionality and


ultimate user configurability

Distribution protection
Eaton’s Cooper PowerE series Form 6 control is designed to be a
flexible, easy-to-use control that has been built to the specifications
of utility crews, service technicians and field operators. It provides
important service restoration operations, with instant access to
operating functions to quickly determine the status of a device, locate
faulted phases, check counters, and find other critical information.

Form 6 control is ideal for Form 6 control is available


a variety of substation in various mounting
applications including: configurations including:
• Main feeder protection • Pole mount
• Industrial service entrance • Yard mount
• Cogeneration inter-tie • Rack mount
• Automation via PeerCommE • Single
communication protocol • Single loop scheme
• Distribution automation via • Pole-mount loop scheme
The ultimate choice for distribution integration with Cooper
Power Series Substation
protection—with the powerful Form 6 Modernization PlatformE Form 6 control can be
control, one platform provides uniform (SMP) line of products used with the following
design, programming and training. • Portable substation protection equipment:
• Reclosers
The versatile Form 6 control • NOVAE
can be used in the following
• NOVA triple-single
line applications:
• RXE
• Main line sectionalizing
• RVE
• Automatic reconfiguration
• PeerComm communication • WE
protocol automation • WVE
• Loop sectionalizing • VWE
• Sectionalizing laterals • VWVE
• Power quality monitoring • VSA
• VSO
• PWE
• PWVE
• Pad-mounted switchgear
(custom applications)
• Breakers (with 5A input
or 1 A CT inputs)
Take control of power quality with Eaton’s knowledge-based
data analysis tools—designed to improve power quality

Use one control for multiple applications:


ProViewE software supports maximum flexibility
and the highest performance standards.
Easy to use: Complex control schemes are easy with
the Idea WorkbenchE feature and detailed help files.
Test your protection logic: Simulate different fault
events to test virtual responses prior to field exposure
with the Virtual Test SetE feature.

• Oscillography • Duty cycle monitor


Simultaneously monitors the Measures and records duty
integrated performance of for each phase to accurately
a recloser and the control, predict contact life of recloser
showing user-defined cycles interrupters and can be
before and after a trigger point adjusted or reset if recloser
is changed or serviced
• Oscillography replay
Previews how the control • Application diagram
will behave for the same fault Saves troubleshooting costs
with altered settings to reduce by allowing you to quickly view
future fault occurrences your system in one window
where active logic elements
• Data profiler
of the control and distribution
Can be customized for sample
system are displayed
rate and metering forms like
weekly load profiles, daily • Comprehensive metering
harmonic disturbances or Reduces operating costs
hourly voltage fluctuations by providing accurate load
current measurements to
• Sequence of events log
balance feeders, improves
Provides detailed reporting of
system planning with real-time
system operations, including
data reports, and increases
current and voltage values
efficiency through quick fault
for a minimum of 90 events.
location and identification
The last five events are
conveniently displayed in
the front panel LCD for
easy access

For Eaton’s Cooper


Eaton
1000 Eaton Boulevard Power series product
Cleveland, OH 44122 information, visit
United States
Eaton.com www.eaton.com/
Eaton’s Power Systems Division cooperpowerseries
2300 Badger Drive
Waukesha, WI 53188
United States
Eaton.com/cooperpowerseries

© 2017 Eaton
All Rights Reserved Follow us on social media to get the
Printed in USA Eaton is a registered trademark. latest product and support information.
Publication No. PA280009EN / Z19455
Supersedes B280-08010 All other trademarks are property
May 2017 of their respective owners.

You might also like