Professional Documents
Culture Documents
MSE Datasheet - 2022 - r30022
MSE Datasheet - 2022 - r30022
Performance Specifications
Inputs3 Fuels Natural Gas or Biogas with Grid-Parallel Load Tracking 20 kW/second up/down
Hydrogen blend up to 30% Power Output Range 0 to 100% power output
Input Pressure 8-25 psig (15 psig nominal)
Water Consumption None Backup6 Grid Parallel to Island Transfer < 10 sec
Maximum Step Load 120% nameplate kVA
Efficiency4 Electrical (LHV, net AC) 45% Building Soft Start Capability Yes
Heat Rate (HHV, net AC) 8,416 BTU/kWh
Other • UL 2200 package • Remote monitoring
Emissions5 NOx < 2.5 ppm (<0.07 lb/MWh) • UL 1741 SA grid-tie inverter • Secure customer portal
Noise < 70 dBA @ 6 feet
1 Projects greater than 1.5 MW can be optimally designed with the use of external inverters.
2 Rated capacity is reduced by 10 kW if operated in the South Coast AQMD..
Physical Weight 20 tons 3 100% hydrogen and 100% ammonia capable with field UL certification.
Dimensions (L x W x H) 20.5’ x 8.5’ x 9.5’ 4 Measured according to ASME PTC 50 at 15 C and 1 atm.
5 Products comply with emissions limits in South Coast AQMD.
6 Performance with purchase of internal backup kit and additional site relays and controls equipment.