SOR - Annexure - I

RFQ document number: AGP/RFQ/C&P/039/DBS-EW


Supply, Fabrication, Installation, Testing & Commissioning of Electrical Works for CNG Daughter Booster Stations for all GA’s
Approx.
Qty Per Unit Total Amount
Sr. No. Item Description UOM
DBS Rates Per station
station
Supply,Installation, Testing and Commissioning of 125 Amp. Switch Fuse Unit (SFU) HRC type with weatherproof enclosure box suitable for fixing on wall/Pole for
1 EA 1 10500 10500
isolation of main Supply from Transformer area.
Supply of 1.1 KV grade, 3C X 2.5 Sq.mm Copper stranded conductor, XLPE insulated, Formed Wire armoured, FRLS PVC Outer sheath (2XWY) Power cables as per
2 M 700 111 77700
technical specifications mentioned in tender.

Laying, Testing and Commissioning of 1.1 KV grade, 3C X 2.5 Sq.mm Copper stranded conductor, XLPE insulated, Formed Wire armoured, FRLS PVC Outer sheath
(2XWY) Power cables in surface trench / on wall / structural surface / in GI pipes / conduits as per site requirements and scopes mentioned in tender. The unit rate shall
2a include laying with necessary trays/trench with GI pipes , glanding with adequate size, weatherproof or flameproof as per area classification ,double compression type M 700 10 7000
brass cable glands and tinned copper / AL. lugs including cutting/stripping of cable insulation, fixing of cable glands, crimping the lugs, termination, connection of cable
armour with earth bar, tools, hardware, PVC insulated tape and all other material required.

Supply of 1.1 KV grade, 3.5C X 50 Sq.mm Copper stranded conductor, XLPE insulated, Formed Wire armoured, FRLS PVC Outer sheath (2XWY) Power cables as per
3 M 50 1225 61250
technical specifications mentioned in tender.

Laying, Testing and Commissioning of 1.1 KV grade, 3.5C X 50 Sq.mm Copper stranded conductor, XLPE insulated, Formed Wire armoured, FRLS PVC Outer sheath
(2XWY) Power cables in surface trench / on wall / structural surface / in GI pipes / conduits as per site requirements and scopes mentioned in tender. The unit rate shall
3a include laying with necessary trays/trench with GI pipes , glanding with adequate size weatherproof or flameproof as per area classification double compression type M 50 25 1250
brass cable glands and tinned copper / AL. lugs including cutting/stripping of cable insulation, fixing of cable glands, crimping the lugs, termination, connection of cable
armour with earth bar, tools, hardware, PVC insulated tape and all other material required.

Supply, Installation, testing & commissioning of UPS systems for 3KVA load with 2 hours battery backup, with its separate battery rack as per Drawing, Specification.
The unit rate shall include loading/unloading, shifting from site store to the place of installation, assembling the UPS / battery rack including mounting & wiring of
4 loose parts by manufacturers, interconnection of batteries, installation on readymade false floor / trench / floor, aligning, levelling, grouting, testing and setting of EA 1 120000 120000
relays and meters including all hardware.(3 kVA load – 1phase input & 1phase output with INBUILT ISOLATION TRANSFORMER (Online ups Unbalance type), with
proper alignment & Support with 2 hr full load battery back up.complete with c/o swtch and interlocking to function either off UPS. )

5 Supply & installation of GI perforated cable tray with cover - 100 mm (W) X 50 mm (H) X 2.5 mm (TH) M 10 441 4410
6 Supply & installation of 2" NB GI pipes, Class B (Medium type) as per IS:1239 M 50 378 18900
Supply & installation of 6-7.5 Mtrs Lighting Poles (410 SP) as per IS 2713 complete with Flameproof Well Glass Fixtures-125 W, FLP Junction box (IP 65) suitable for 4C, 6
7 EA QRO 22000 0
sq.mm. YWY cable, necessary excavation, Civil foundation etc. as per approved drg.
Supply & Installation of bracket mounting 50 mm dia. Pipe suitable for lighting fixture installation on wall / structure surface complete with accessories & Flameproof
8 EA QRO 483 0
Junction box having terminal, suitable for 4C 6 sq. mm YWY cable.
Supply & Installation of 250 W Metal halide (T), flood light luminaries integral type complete with tube & control gearbox etc. (CGL type FADT 1125 IH (CA) or
9 EA QRO 4500 0
equivalent).
Supply & Installation of 250 W, HPMV, Flameproof and Weatherproof Floods Lighting Fixture, Non-integral type, Construction - Cast Aluminium Alloy LM6 as per IS
10 EA QRO 10200 0
2148, Epoxy finish, Ingress Protection - IP 65 Area Classification - Zone 1 & 2, Gas Group IIA & IIB, Temperature class-T3.
Supply, Fabrication & erection of items fabricated from structural steel covered under various items listed like local control station support, Panel support, Cable tray
11 Kgs. 40 80 3200
support, bracket for lighting fittings, junction box and other Electrical structures.
Supply of GI, 3 Mtr.Long Maintenance Free Earthing Electrode, 100 mm Dia.-Dual pipe technology, adequately filled composition of highly conductive metallic
12 EA 4 6895 27580
compound as per approved specifications.
Supply of Copper bonded, 3 Mtr. Long Maintenance Free Earthing Electrode, 80 mm Dia.-Dual pipe technology, adequately filled composition of highly conductive
13 EA 4 7293 29172
metallic compound as per approved specifications.
Installation, Testing of GI/Cu, 3 Mtr. Long Maintenance Free Earthing Electrode, 100/80 mm Dia at 3 Meters depth by auguring / excavation of soil (Natural / Rocky),
14 EA 8 3312 26496
backfilling including construction of earth pit as per standard IS:3043 .
15 Supply & installation of GI (99 %) Earthing Strips - 40x6 mm M 70 180 12600
16 Supply & installation of Copper (99 %) Earthing Strips - 25x3 mm M 50 450 22500
17 Supply,Laying and Termination of 1C X 16 Sq.mm Copper Flexible wires for Earthing Connectivity M 25 140 3501.5

18 Supply & installation of Heavy Clamp crocodile type Clamps connected with 5 mtrs earthing flexible 25 Sq.mm wire LCV/HCV as per instruction of EIC. EA 7 219 1533

19 Supply & Installation of Earth Markers-PVC/Acrylic (12"X8") as per AGP design & Instruction. EA 8 399 3192
Charges for obtaining of HT/LT Power connection for CNG Station from concerned power supplier within time frame by required liaison work with EB officials /
20 Electrical Inspector, preparation of drawings, filling application, approval of dwgs., arranging site visits required follow-ups, conveyance, any other liaison as required (if EA QRO 43000 0
any), except Statutory fees.
Extending consulting liasoning services for rerouting of LT/HT Overhead line from CNG plot area including application, liasoning, follow-ups, clarification/attending
21 EA QRO 35000 0
queries of authorities, site visit with officials till completion of job etc…. (Upto 50 meters Line)
22 Supply of Aluminium ladder for 7.5 Mtrs. height complete with castors for movability and easy access for maintenance as per approved drawing & instruction of EIC. EA 1 14500 14500

Supply & Installation of Cable Route Markers as per Indian standard size and instruction of AGP including Painting & Stencilling (Contractor shall provide details of
23 EA 3 186 558
cable route markers as per direction of EIC).
Supply & Installation of Emergency Switch with weatherproof encloser arrangement (outside compressor area) for emergency shutdown of Compressor & Electrical
24 EA 2 315 630
panel.
25 Supply & Installation of Danger Caution Board for 440V/11000V/22000V as per AGP/standard design. EA 6 214 1284

26 Supply & Installation of Shock treatment charts confirming to IE rules, laminated with glass and teak wood frame including supply of necessary hardware EA 2 298 596

27 Supply of First aid box with front door having clear glass and first aid material conforming to IE rules with prescribed medicines. EA 2 1222 2444
28 Supply of Rubber hand gloves duly tested ISI, IE Rules.- 1100V grade EA 4 750 3000
29 Supply of Rubber hand gloves duly tested ISI, IE Rules - 28 KV grade EA QRO 900 0
Supply of Fire Retardant Neoprene Rubber Mats- with well embossed KV Rating, Reference standards IS 15652: 2006 (new) for Electrical Room. (width 1 Meter,3 mm
30 M 5 1500 7500
thick).- 415V grade.
31 Supply of CO2 type Fire Extinguishers - 4.5 KGs capacity with stand. EA 1 4463 4463
32 Supply of Sand Bucket (GI), 20 Gauge, with Stand / Hook, Durable with Red Paint. EA 4 893 3572
33 Excavation work in normal soil upto minimum 1.5 meter depth for Cable trench on PCC / land surface. M QRO 125 0
34 Excavation work upto minimum 1.5 meter depth for Cable trench for electrical installation work on RCC land / surface including RCC breaking. M QRO 250 0
Supply, Installation,Testing & commissioning of Trivectometer Flush mount 96 x 96 x 80 mm load manager type Enercon EM 6400 or equivalent meter of accuracy class
35 EA 1 6630 6630
1 as per IS 13779.( 3 phase, 4 wire measuring)
Supply, Installation, Testing & Commissioning of standard make Energy Meter 3 Phase 4 wire, Class 1 (one) analogue type with necessary required CT along seal
36 EA 1 4500 4500
standard make panel box on wall / in panel.(Energy Meter shall be supplied of approved vendor only).
Supply & installation of 6-7.5 Mtrs Lighting Poles (410 SP) as per IS 2713 complete with Flameproof LED TYPE Well Glass Fixtures-125 W, FLP Junction box (IP 65)
37 EA 5 20000 100000
suitable for 4C X 6 sq.mm. YWY cable, necessary excavation, Civil foundation etc. as per approved drg.
38 Supply & Installation of 250 W LED Type flood light luminaries integral type complete with control gearbox etc. (CGL type FADT 1125 IH (CA),or equivalent). EA 5 5500 27500

Supply & Installation of 250 W,,LED, Flameproof and Weatherproof Floods Lighting Fixture, Integral type, Construction - Cast Aluminium Alloy LM6 as per IS 2148,
39 EA 5 11000 55000
Epoxy finish, Ingress Protection - IP 65 Area Classification - Zone 1 & 2, Gas Group IIA & IIB, Temperature class-T3.
Supply of 1.1 KV grade, 4C X 25 sq.mm. Copper stranded conductor, XLPE insulated, GS strips Armoured, FRLS PVC Outer sheath (2XFY) Power cable as per technical
40 EA 200 830 166000
specifications mentioned in tender.

Laying, Testing and Commissioning of 1.1 KV grade, 4C X 25 sq.mm. Copper stranded conductor, XLPE insulated, GS strips Armoured, FRLS PVC Outer sheath (2XFY)
Power cables in surface trench / on wall / structural surface / in GI pipes / conduits as per site requirements and scopes mentioned in tender. The unit rate shall include
41 laying with necessary trays/trench with GI pipes , glanding with adequate size weatherproof or flameproof as per area classification double compression type brass EA 200 25 5000
cable glands and tinned copper / AL. lugs including cutting/stripping of cable insulation, fixing of cable glands, crimping the lugs, termination, connection of cable
armour with earth bar, tools, hardware, PVC insulated tape and all other material required.

Supply of 1.1 KV grade, 3C X 6 Sq.mm Copper stranded conductor, XLPE insulated, Formed Wire armoured, FRLS PVC Outer sheath (2XWY) Power cable as per technical
42 EA QRO 170 0
specifications mentioned in tender.

Laying, Testing and Commissioning of 1.1 KV grade, 3C X 6 Sq.mm Copper stranded conductor, XLPE insulated, Formed Wire armoured, FRLS PVC Outer sheath (2XWY)
Power cable cables in surface trench / on wall / structural surface / in GI pipes / conduits as per site requirements and scopes mentioned in tender. The unit rate shall
43 include laying with necessary trays/trench with GI pipes , glanding with adequate size weatherproof or flameproof as per area classification double compression type EA QRO 10 0
brass cable glands and tinned copper / AL. lugs including cutting/stripping of cable insulation, fixing of cable glands, crimping the lugs, termination, connection of cable
armour with earth bar, tools, hardware, PVC insulated tape and all other material required.

44 Supply & Installation of GI Earthing Strips – 25 mm x 3 mm EA QRO 50 0


Supply, Installation, Testing and Commissioning of 125 AMP Main LT Panel (D.Booster)-Floor Mounted type as per SLD Ref.: AGP-CON-GEN-OMC-DBS-0017& technical
45 EA 1 300000 300000
specification mentioned in tender.(It includes all MCB,MCCB,capacitor bank with APFC,as per SLD)
Supply, Installation, Testing and Commissioning of 125 AMP Main LT Panel (D.Booster)-Floor Mounted type as per SLD Ref.: AGP-CON-GEN-OMC-DBS-0017& technical
46 EA QRO 300000 0
specification mentioned in tender.(It includes all MCB,MCCB,capacitor bank with contactor control,as per SLD)
Suuply, installation, testing & Commissioning of 60 KVA Oil Cooled, wheel mounted, Servo Stabliser (copper wounded, input range 340-470, output voltage 415±1%,
47 Overload 110% for 5 min, correction speed 35 volts per second) with Spike Suppression through MOV and Surge Arrestor. Fault Annunciation, Event Log facility shall be EA 1 156000 156000
there.
Total Amount Per Station 12,89,961.50
GST@18% 2,32,193.07
Grand Total Amount Per Station Incl. GST in Rs. 15,22,154.57
Sr. Description Approved Make

1 Power Capacitor Madhav / L&T/ Siemens / Malde / Legrand


2 MCCB Havells / L&T / Siemens / Schneider / GE/ CSC
MDS / Havells / L&T / Siemens / Merlin Gerin / Indo-Asian / Standard / Datar / GE /
3 MCB I ELCB I ELMCB I HRC
esc / Hager / Ligrand
4 Surge Arrester Phoeniex / OBO / Schneider / HPL / L&T / Siemens
Havells / Enercon / Conserve / L&T / Trinity /Rishabh / AE / IMP / Siemens /
5 Energy Meters / Measuring Instruments
Schneider
6 UV / OV Relay Minilec / Siemens / Rishabh / GIC (L&T)
7 Current Transformer AE / Meco / Ashok / Ashmor / Kappa / Indcoil
8 Fuse L&T / EE / CGl / GE / Schneider Electric / CSC
9 Distribution board s-Double door L&T / CGL / GE / Siemens / Schneider / CSC Legrand, Hensel, Indo Asian
10 Push Button Actuators / LED Indication Lamp / Selector Switch L&T / Siemens / Technique / GE /Salzer / Siemens / Vashinu / Concord
11 Switch Socket, Plugs, Accessories Roma Anchor / MK / MDS
12 Lighting Fixtures Crompton / Wipro / Philips / GE / Havells
13 Flameproof Light Fixture, FLP Junction Box & FLP Switch Socket FCG / CEAG / Flexpro / Crompton / Baliga / Sudhir / Flameproof Equipment
14 MF Earth Electrode JK / Earthrite / Ashlok
15 IT Cable / Wires Finolex / Polycab / Nieco / RPG / Incab / KEI /Universal / Avocab / CCIL / Gemscab
16 Control Wires Finolex / Havells / Polycab / Primecab
17 Rigid PVC FR LS LH SFT Conduit Precision plastic industries, Polyca b, AKG, Nihir
18 Cable Gland Control Switch Gear / Electromac / Commet / Baliga / Flameproof Control Gear
19 Cable lugs Dowels/ Comet / HMI / 3D
20 Terminals Elmex / (Connectwell / Tosha / Phoenix
Jindal/Fuji/Astech/Antandra/Farmax/Servocon/Purevolt/BELTRONICS / CRAYCART /
21 Servo Stabilizer
CONSUAL NEO WATT
22 UPS Luminous/Fuji/Schnider/Vertiv/Microtek/EMERSION / APC / EATON