Track @ max.600 c/c Stud @ max.300 c/c Furring Channel @ max.450 c/c Non Combustible Rockwool
According to AS 1530.1 10 NO EXCEPTION MINOR COMMENT

450 450 450 450 450 450 120 250 TAKEN RESUBMISSION NOT REQUIRED

REJECTED FOR RECORD PURPOSE

REVISE AND RESUBMIT APPROVED FOR CONSTRUCTION

REVIEWED BY:
(NAME)

SIGNATURE:
120 120 DATE:

COPYRIGHT EAST COAST CONSTRUCTION COMPANY


PTY. LTD.

SEC
REPRODUCTION OF THE WHOLE OR PART OF THE

4
DOCUMENT CONSTITUTES AND INFRINGES
COPYRIGHT. THE INFORMATION, IDEAS AND
CONCEPTS CONTAINED IN THIS DOCUMENT ARE
CONFIDENTIAL. THE RECIPIENT(S) OF THIS DOCUMENT
ARE PROHIBITED FROM DISCLOSING SUCH
600 600 INFORMATION IDEAS AND CONCEPTS TO ANY PERSON
WITHOUT PRIOR WRITTEN CONSENT OF THE
COPYRIGHT HOLDER. ECCC HOLDS A LICENSE FROM
ARBT IN RESPECT OF PROPRITARY ITEMS

NOTE THIS DRAWING IS PREPARED BY EAST COAST


CONSTRUCTION COMPANY UNDER ITS QBCC LICENCE
FOR THE USE OF EAST COAST CONSTRUCTION
COMPANY PTY LTD AS THE CONTRACTOR ON THIS
PROJECT

SUB- CONTRACTORS TO CHECK AND VERIFY ALL


300 300 300 300 300 300 300 300 LEVELS, DATUMS & DIMENSIONS ON SITE AND SHALL
300 300 300 280 REPORT ANY DISCREPANCIES OR OMISSIONS TO THIS
OFFICE PRIOR TO START OF WORK & DURING THE
CONSTRUCTION PHASE.
THE DRAWING ARE TO BE READ IN CONJUNCTION
WITH STRUCTURAL, MECHANICAL, ELECTRICAL AND
OR ANY OTHER CONSULTANTS DOCUMENTATION AS
600 600 MAY BE APPLICABLE TO THE PROJECT PRIOR TO
STARTING & DURATION OF THE WORKS.

P-14
162 Rondo PS17
Rondo P01

450 max. 450 250


Lounge
CH-2538 600 600 Non Combustible Rockwool
According to AS 1530.1
Furring Channel @ 450mm c/c B 14-12-20 DS DD PRELIMINARY ISSUE
A 12-12-20 DS DD PRELIMINARY ISSUE
Track@ 600 c/c
REV DATE DRN CHK DESCRIPTION
Stud @ 300 c/c CLIENT:

9.5mm Unispan Board


ASIA PACIFIC
3
TYP.SECTION-4
SEC
4 Scale: 1:10
600

120 600 600 600 600


EAST COAST CONSTRUCTION COMPANY PTY LTD.
E-Mail : admin@ecccgroup.com.au
Telephone : +61 (448) 904 475

Design & Detailed Engineering:

Track Stud @ 300 c/c


Bradman Technologies Private Limited.
162 31/22, Victoria Cresent Rd. Egmore, Chennai-8, India
TEL: +91 44 42043347 | Email: info@bradmanit.com
False Ceiling PROJECT:

9.5mm Thk.Unispan Board


PROPOSED 12 STOREY
Rondo PS17 Furring Channel @ max.450mm c/c Non Combustible Rockwool RESIDENTIAL AT PLOT-50&
According to AS 1530.1 54,CARL STREET,
16 Thk. FR Board
WOOLOONGABBA,QLD,AUSTRALIA
Party Wall TYP.SECTION-3 LEGENDS :
3 Scale: 1:10 DRAWING TITLE :
P01 - CORNER BEADS TYPICAL CEILING FRAME DETAILS @
LIVING AREA
PS17 - INTERNAL CORNER BEADS DRW : DS CHD : DD

P11 - 6.5mm BOARD STOPPING BEADS PROJECT NO : 1802


DRAWING NO : A-260-2
P12 - 10mm BOARD STOPPING BEADS SCALE : AS SHOWN

P14 - 16mm BOARD STOPPING BEADS SIZE : A3 REV : B


DATE: 14.12.2020

You might also like