1802 A 216 K Unit 105 RCP
1802 A 216 K Unit 105 RCP
SIGNATURE:
2106 350 2683
275
KBF FOR ECCC
510
600
KITCHEN
COPYRIGHT EAST COAST CONSTRUCTION COMPANY
CH-2250 PTY. LTD.
1400
1402
REPRODUCTION OF THE WHOLE OR PART OF THE
600
DOCUMENT CONSTITUTES AND INFRINGES
KITCHEN LINE COPYRIGHT. THE INFORMATION, IDEAS AND
BELOW
800
AP CONCEPTS CONTAINED IN THIS DOCUMENT ARE
CURTAIN TRACK CONFIDENTIAL. THE RECIPIENT(S) OF THIS DOCUMENT
290
ARE PROHIBITED FROM DISCLOSING SUCH
INFORMATION IDEAS AND CONCEPTS TO ANY PERSON
LAUNDRY WITHOUT PRIOR WRITTEN CONSENT OF THE
COPYRIGHT HOLDER. ECCC HOLDS A LICENSE FROM
CH-2250 682 3134 600 722 3477 ARBT IN RESPECT OF PROPRITARY ITEMS
3226
2389 20 5525 250 NOTE THIS DRAW ING IS PREPARED BY EAST COAST
614
CONSTRUCTION COMPANY UNDER ITS QBCC LICENCE
FOR THE USE OF EAST COAST CONSTRUCTION
351
1826
CH-2538 REPORT ANY DISCREPANCIES OR OMISSIONS TO THIS
1979
600
SEC 3
A 250
600
559
AG
450
120
AG AG
10
153
10
10
120
AG AG
120
239
363
387
600
600
600
CH-2200 CH-2200 K 10.08.2020 MG DAN REVISED AS PER FLOOR PLAN
150
AP 2114 J 21.01.2020 JN BB RREVISED AS PER COMMENTS
H 06.01.2020 JN BB RREVISED AS PER COMMENTS
600
CH-2200 BED-2 700 1313 672 172 224 D 09.09.2019 ASM BB PRELIMINARY ISSUE
C 10.08.2019 ASM BB PRELIMINARY ISSUE
BED-1
250
2982
REV DATE DRN CHK DESCRIPTION
243
CH-2200
318
CLIENT:
2627
2626
ENSUITE
AP CH-2250
ASIA PACIFIC
BULK HEAD
600
600
172
710 1985 262
600 730 600 967
AG
DESIGN & CONSTRUCTION:
188 290 2460
CH-2435
670
595
General Notes:
LEGENDS:
1. All penetrations for services through metal stud joists and supports shall be fitted
with snap bushes to protect services from sharp edges.
2. All services shall be securely clamped to avoid displacement and damage through - 9.5mm UNISPAN BORAL BOARD - CH-2538 FROM STRAKEN PANEL (DROP 162mm)
transport, movement , water hammer etc and as detailed in the services layout RCP Bradman Technologies Private Limited
31/22,Victoria Cresent Rd.Egmore,Chennai - 8,India
drawing. TEL: +91 44 42043347 Email: info@bradmanit.com
3. False ceilings linings, framing etc shall be fabricated with non combustable PROJECT:
materials. - 6mm FC HUME BOARD - CH-2250 FROM STRAKEN PANEL (DROP 450mm)
PROPOSED RESIDENTIAL AT PLOT-50&
4. Fixings for services and fixings for wall studs below fire ceiling layer shall not be REFERENCE DRAWINGS: 54,CARL STREET,
WOOLOONGABBA,QLD,AUSTRALIA
located at fire sheet joints.
- 9.5mm UNISPAN BORAL BOARD - CH-2250 FROM STRAKEN PANEL (DROP 450mm) A 250 - SECTIONAL & BLOWN UP DETAILS
5. All fire ceiling joints shall be taped and set prior to installation of false ceilings and
full height walls and sheets laid in a staggered pattern. DRAWING TITLE:
Notes:
6. penetrations through fire ceiling layer for vertical plumbing pipes shall be made - 9.5mm UNISPAN BORAL BOARD - BULK HEAD DROP
with clean square edges with casing bead left ready for site fixed linings and fire FOR CURTAIN TRACK - CH - 2435 FROM STRAKEN PANEL (DROP 265mm) - ALL THE CEILING HEIGHTS ARE MEASURED FROM STRAKEN PANEL UNIT 105 - RCP
collars as detailed . - ALL DROPS ARE MEASURED FROM FIRE CEILING LEVEL
8/10/2020 4:46:45 PM
- ALL TOILET CELINGS & LAUNDRY CEILINGS ARE FIXED AT SITE ONLY
- DIMENSIONS ARE ALL MEASURED FROM FINISH TO FINISH DRAWN: CHECKED:
7. Fire linings shall be completed to full perimeter edge of modules. - 10mm PLYWOOD BOARD - CH-2250 FROM STRAKEN PANEL (DROP 450mm) - ACCESS PANEL LOCATION IN TOILET TO BE VERIFED BY FACTORY ASM BB
8. Check and confirm items 1 to 7 above prior to sheeting false ceilings FIRST ISSUE: SCALE:
AG - AIR GRILL 01.05.2019 1 IN 40 @ A3
9. For Lighting layout refer electrical drawing.
PROJECT NO DRAWING NO REVISION
AP - ACCESS PANEL
1802 A 216 K