Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 4

UNIT 2 DEFECTS

Responsibility No of Defects
JP Shrivastav 2
Sanjoy Dutta 6
Sudhir Singh 11
Vinit Pradhan 2
Total 21
Sr. No. Notification Order Description
1 3000482692 U#2 Sump pit P/P A&B not start in auto.
2 3000446071 Unit-2 ECU-A cooling motor N/A
3 3000471337 U2 EBD MOV-2 sound coming during opening
4 3000471613 u2 ID fan B lub oil filter A oil seepage
5 3000417916 300394235 Unit-2 RH attemperation root MOV not ope
6 3000470660 Unit-2 IBD tank drain line leakage
7 3000475993 ?U2 CF-B CLEANING MOTOR SHAFT BROKEN
8 3000491664 U-2 pass-B SH attemperation before MOV i
9 3000434617 IP governing valve,MS stop valve , TVL,T
10 3000471549 U-2 cond cycle water I/L pr showing wron
11 3000471547 300452657 U-2 tbn brg temp no-2 high
12 3000475334 u2 vacuum breaker MOV circuit fault alar
13 3000476100 U2 TURBINE BEARING NO.2 RTD OIL SEEPAGE
14 3000485149 U#2 SSC temp not show in systaem
15 3000481477 u#2 3rd BP attemp MOV1 ckt fault
16 3000483934 U#2 Generator stator winding temperature
17 3000484900 U#2 Gen stator core temp-8 running high.
18 3000485304 300465791 U#2 Corner 4 burner tilt got stuck at 68 update: nop beyo
19 3000486102 u2 MS pressure high false alarm coming
20 3000479391 U2 D/A Pegging line lkg near MIV
21 3000487662 u#2 3rd bypass attemperation mov-1 NOP
22 3000485523 LPDP B breaker mechanism issue
23 HPH2 drip to D/A demetering req
24 3000485339 GCW cooler cleaning req
26 LPBP CV passing
27 Hotwell makep CV passing DM water showing 0
28 3000488826 BFP 2A oil water mixing
29 3000478594 VCP 2A shutoff vacuum low
31 Oil gun AB3 guide pipe damaged
32 CWP B discharge valve passing
33 3000481902 ESP field 1A2 2A2 2A3 spark coming
34 3000469817 ID fan B RPM not showing
35 3000488501 U2 GCW tank level deviation in DCS & Local
36 U2 GCW filter dp high
39 3000487517 U-2 HPBP after drain PCV NOP
40 3000489708 U#2 CWP A thrust brng temp high
41 ICW A pump DE heavy gland leakage
Priority Responsibility Target date colour
JP Shrivastav
JP Shrivastav
1 Sanjoy Dutta
1 Sanjoy Dutta
1 Sanjoy Dutta
Sanjoy Dutta
1 Sanjoy Dutta
1 Sanjoy Dutta
Sudhir Singh
Sudhir Singh
Sudhir Singh
Sudhir Singh
1 Sudhir Singh
Sudhir Singh
Sudhir Singh
Sudhir Singh
1 Sudhir Singh
1 Sudhir Singh
Sudhir Singh
1 Vinit Pradhan
1 Vinit Pradhan
1 JP Shrivastav
1 Vinit Pradhan
1 Vinit Pradhan
1 Vinit Pradhan
1 Vinit Pradhan
1 Vinit Pradhan
1 Vinit Pradhan
1 Sanjoy Dutta
1 Vinit Pradhan
1 JP Shrivastav
Sudhir Singh
1 Sudhir Singh
1 Vinit Pradhan
Sudhir Singh
1 JP Shrivastav
1 Vinit Pradhan
Remarks
Now ok, Notification to be closed

Job completed, point attened

Not operating beyond 40%

You might also like