Professional Documents
Culture Documents
LM一80认证PCT3030 TH LM-80 S-F3-10-THI
LM一80认证PCT3030 TH LM-80 S-F3-10-THI
Administrative Information
DUT Identification
DUT Characteristics
DGY.S-F3-10-THI
4 175 1.085 2 2 0.6 0.1
I
DGY.S-F3-10-THI
4 175 1.05 2 2 0.5 0.1
II
Table of Contents
1.General Information....................................................................................................................................... 5
1.1 Description of LED Light Sources ......................................................................................................... 5
1.2 Standards Used ..................................................................................................................................... 5
1.3 Test equipment list ................................................................................................................................ 5
1.4 Drive Level ............................................................................................................................................. 6
1.5 Ambient Conditions for Maintenance Test ............................................................................................ 6
1.6 Photometric Measurement Method ....................................................................................................... 6
1.7 Sample Set ............................................................................................................................................ 7
2. SUMMARY OF TEST RESULT ..................................................................................................................... 8
3.Test Data....................................................................................................................................................... 11
3.1 Data Set 1, 85°C, 175mA (Lumen Maintenance) ................................................................................ 11
3.2 Data Set 1, 85°C, 175mA (Photosynthetic Photon Flux Maintenance) ...............................................12
3.3 Data Set 1, 85°C, 175mA (Forward Voltage) ...................................................................................... 13
3.4 Data Set 1, 85°C, 175mA (Chromaticity Shift) .................................................................................... 14
3.5 Data Set 2, 105°C, 175mA (Lumen Maintenance) .............................................................................. 15
3.6 Data Set 2, 105°C, 175mA (Photosynthetic Photon Flux Maintenance) .............................................16
3.7 Data Set 2, 105°C, 175mA (Forward Voltage) .................................................................................... 17
3.8 Data Set 2, 105°C, 175mA (Chromaticity Shift) .................................................................................. 18
4 . EUT PHOTO ................................................................................................................................................ 19
4.1 Mechanical Dimensions ...................................................................................................................... 19
4.2 EUT Photo ........................................................................................................................................... 19
1.General Information
Sample Size:
50Pcs samples were received on 2019-04-14 ,The samples were numbered from S1 to S25 and S26 to S50.
Power: 1.2W
CRI: 80
Sampling Method:
LED samples for IESNA LM-80 testing consist of units built from three manufacturing lots with each manufacturing lot built
from different wafer lots built on non-consecutive days.These manufacturing lots are picked to represent a wide parametric
distribution.
Each Sample is soldered to all of the reliability stress boards for a given set of IESNA LM-80 tests.
▪ ANSI/IES LM-80-15 IES Approved Method for Luminous Flux and Color Maintenance of LED Packages,Arrays and
Modules
▪ ENERGY STAR® Requirements for the use of LM-80 Data(This standard was not accredited by NVLAP )
Statement of Traceability: Guangdong Meide Testing Technology Co., Ltd.attested that all calibration has been performed using
suitable standards traceable to national primary standards and International System of Unit(SI).
Samples are driven with a constant direct current (DC) during maintenance test, photometric and electrical measurement.
The current value was regulated to within ±3% of the specified value of the manufacturer during maintenance test, and
was within ±0.5% during photometric and electrical measurement test.
For lumen maintenance test, samples within one data set, were installed on cooling boards in thermal chambers with minimal
ambient airflow.The case temperature and ambient temperature was monitoredby thermocouples which one was soldered to
the coldest DUTs’ case (TMPLED) location, while the other is mounted at a distance of 5 mm above the TMP location.
During life testing, TMPLED of the coldest LEDs were maintained at a temperature that was greater than or equal to 2°C below
the corresponding nominal case temperature. Surrounding air was maintained at a temperature that was greater than or equal
to 5°C below the corresponding nominal case temperature. Thermocouples were shielded from direct DUT optical radiation
and comply with ASTM E230 Table 1 “Special Limits”.
Samples were connected to DC power supply in series circuits with a constant current.The forward current was regulated to
within ±3% of the specified value of the manufacturer.
The relative humidity within chamber was kept less than 65% during test.
For photometry measurement, the ambient temperature during test was set to 25°C ± 2°C, RH<65%.
Integrating sphere and spectroradiometer is used to measure luminous flux and chromaticity coordinate u’v’.2π measurement
was used and sample was drived by DC power supply. The forward current was regulated to within ±0.5% of the nominal value.
The test system was calibrated by halogen reference lamp.The ambient temperature during test was set to 25°C ± 2°C, RH <65%.
The temperature measurement point was located in the sphere and the temperature was detected by a temperature probe.
The uncertainty of the light output(luminous flux) measurements is U=2.1%(K=2),at the 95% confidence level.The uncertainty
of the correlated color temperature measurements is U=18K(K=2),at the 95% confidence level.The uncertainty of the
temperature is U=0.6°C(K=2),at the 95% confidence level.
Number of Units: 25
Number of Units: 25
Data Sample Failures Test Test Reported TM-21 Reported TM-21 L90
α β
Set: Size Observed: Interval Duration L70 Lifetime Lifetime
1 25 0 1000hrs 9000hrs 2.712E-06 3.177E-06 >54000hours 42000hours
Data Set: 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000hrs 8000hrs 9000hrs
Average Photosynthetic Photon Flux Maintenance (Percentage of Initial Photosynthetic Photon Flux)
Data Set: 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000hrs 8000hrs 9000hrs
Data Set: 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000hrs 8000hrs 9000hrs
3.Test Data
3.1 Data Set 1, 85°C, 175mA (Lumen Maintenance)
PPF
Photosynthetic Photon Flux Maintenance (%)
Sample (μmol/s)
Number
0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000hrs 8000hrs 9000hrs
S1 2.529 100.23 100.12 99.87 99.62 99.44 99.14 98.74 98.28 97.91
S2 2.521 99.92 100.00 99.83 99.59 99.31 99.12 98.89 98.60 98.36
S3 2.545 100.15 100.05 99.94 99.69 99.58 99.27 98.85 98.39 98.02
S4 2.539 100.06 99.85 99.49 99.37 99.22 99.06 98.91 98.41 98.10
S5 2.521 100.00 100.02 99.82 99.63 99.51 99.38 98.65 98.27 98.13
S6 2.540 100.04 99.77 99.61 99.42 99.21 99.11 98.93 98.56 98.21
S7 2.521 100.17 99.97 99.79 99.53 99.38 99.14 98.91 98.57 98.18
S8 2.582 100.20 99.93 99.84 99.61 99.39 99.19 98.96 98.66 98.27
S9 2.498 100.16 100.01 99.95 99.79 99.52 99.27 98.95 98.63 98.31
S10 2.540 100.26 100.20 99.84 99.62 99.42 99.24 98.89 98.66 98.23
S11 2.539 100.18 99.89 99.57 99.42 99.17 99.04 98.80 98.61 98.22
S12 2.603 99.88 99.62 99.57 99.34 99.22 99.10 98.90 98.64 98.35
S13 2.513 100.14 100.03 99.88 99.81 99.59 99.29 99.00 98.70 98.44
S14 2.535 100.21 100.23 99.97 99.64 99.36 99.15 98.90 98.64 98.39
S15 2.479 99.92 99.95 99.63 99.48 99.23 98.97 98.63 98.41 98.17
S16 2.531 100.03 100.02 99.93 99.74 99.68 99.41 99.02 98.74 98.28
S17 2.535 100.01 99.86 99.80 99.67 99.54 99.39 99.11 98.79 98.35
S18 2.514 100.19 100.21 99.98 99.75 99.54 99.45 99.28 98.83 98.49
S19 2.514 100.23 100.10 99.83 99.61 99.42 99.14 99.00 98.66 98.24
S20 2.534 100.16 99.82 99.70 99.53 99.47 99.20 98.84 98.46 98.13
S21 2.510 100.18 100.03 99.87 99.65 99.43 99.29 99.03 98.76 98.34
S22 2.502 100.01 99.89 99.63 99.48 99.41 99.21 98.80 98.56 98.25
S23 2.492 100.06 99.94 99.89 99.72 99.56 99.36 99.03 98.77 98.39
S24 2.502 100.27 100.29 100.02 99.77 99.41 99.21 98.96 98.49 98.14
S25 2.498 100.24 99.90 99.87 99.68 99.52 99.29 99.03 98.70 98.31
Ave. 2.525 100.12 99.99 99.80 99.61 99.42 99.22 98.92 98.59 98.25
Med. 2.521 100.16 100.00 99.84 99.62 99.42 99.21 98.91 98.63 98.25
St dev 0.0268 0.1134 0.1531 0.1456 0.1316 0.1357 0.1234 0.1386 0.1527 0.1323
Min. 2.4792 99.88 99.62 99.49 99.34 99.17 98.97 98.63 98.27 97.91
Max. 2.603 100.27 100.29 100.02 99.81 99.68 99.45 99.28 98.83 98.49
PPF
Sample Photosynthetic Photon Flux Maintenance (%)
(μmol/s)
Number
0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000hrs 8000hrs 9000hrs
S26 2.429 100.18 99.92 99.72 99.33 98.96 98.69 98.33 98.06 97.82
S27 2.430 99.94 99.80 99.42 99.24 98.97 98.63 98.41 97.86 97.76
S28 2.455 99.94 99.80 99.53 99.22 98.71 98.38 98.16 97.85 97.55
S29 2.537 99.96 99.77 99.53 99.28 99.00 98.79 98.39 98.01 97.64
S30 2.422 100.12 99.89 99.61 99.33 99.10 98.78 98.38 98.14 97.69
S31 2.466 99.76 99.64 99.40 99.09 98.86 98.57 98.38 97.96 97.50
S32 2.482 99.88 99.62 99.38 99.03 98.90 98.64 98.25 97.89 97.81
S33 2.512 99.89 99.35 99.24 99.04 98.77 98.54 98.15 97.95 97.81
S34 2.457 100.21 99.96 99.70 99.60 99.19 99.05 98.70 98.29 97.86
S35 2.445 100.00 99.83 99.65 99.40 99.27 98.83 98.44 98.14 97.76
S36 2.469 100.05 99.88 99.63 99.35 99.07 98.74 98.30 98.11 97.91
S37 2.428 100.14 99.95 99.52 99.47 99.20 98.76 98.54 98.18 97.88
S38 2.443 99.99 99.89 99.60 99.34 98.92 98.54 98.46 98.09 97.88
S39 2.463 99.93 99.74 99.49 99.29 98.95 98.71 98.37 98.19 97.75
S40 2.467 100.11 99.89 99.58 99.45 98.95 98.77 98.29 98.05 97.92
S41 2.500 99.79 99.70 99.46 99.25 99.04 98.81 98.56 98.12 97.92
S42 2.466 99.82 99.61 99.36 99.24 99.09 98.63 98.36 98.03 97.52
S43 2.440 100.00 99.74 99.42 99.22 98.89 98.61 98.24 98.05 98.02
S44 2.485 99.86 99.61 99.27 99.15 98.90 98.37 98.06 97.83 97.61
S45 2.477 99.83 99.69 99.48 99.14 98.90 98.55 98.14 97.89 97.71
S46 2.473 100.06 99.93 99.66 99.26 98.83 98.47 98.33 97.92 97.61
S47 2.486 99.77 99.63 99.50 98.98 98.82 98.44 98.16 97.85 97.58
S48 2.515 100.02 99.69 99.55 99.32 99.13 98.83 98.45 97.93 97.57
S49 2.485 99.88 99.64 99.59 99.34 99.18 98.87 98.64 98.15 97.93
S50 2.510 99.82 99.54 99.28 99.12 98.85 98.61 98.40 98.18 97.70
Ave. 2.470 99.96 99.75 99.50 99.26 98.98 98.67 98.35 98.03 97.75
Med. 2.467 99.94 99.74 99.52 99.26 98.95 98.64 98.37 98.05 97.76
St dev 0.0301 0.1303 0.1513 0.1332 0.1442 0.1452 0.1641 0.1569 0.1283 0.1471
Min. 2.422 99.757 99.347 99.241 98.982 98.711 98.37 98.06 97.83 97.497
Max. 2.537 100.209 99.964 99.718 99.595 99.268 99.053 98.7 98.289 98.015
4 . EUT PHOTO
TMPLED