Download as pdf or txt
Download as pdf or txt
You are on page 1of 81

FORM- Z

Project: PROPOSED STATE UNIVERSITY AT VILLAGE PUNWARKA,DISTRICT SAHARANPUR, U.P.

AMOUNT (IN LAC) AMOUNT (IN LAC) AS


SR.N DESCRIPTION OF ITEM VARIATION REMARK
AS PER DPR PER REVISED DPR

1 TOTAL COST OF PROJECT 8006.04 8395.17 389.13

LESS 5% 5% NOT DEDUCTED IN REVISED


400.30 419.76
AMOUNT

TOTAL 7605.73 7975.41 389.13

2 CONTINGENCIES CHARGES @ 1.0% 76.06 79.75 0.00

3 SUPERVISION CHARGES @ 2% 152.11 159.51 0.00

4 AGENCY CHARGES@3% 228.17 239.26 0.00

5 ADD FOR @ 1.0% LABOUR CESS 76.06 79.75 3.89

6 ADD FOR GST @ 12% UP TO 18 JULY 912.69 957.05 46.70

7 ADD FOR ELECTRICAL CONNECTION AND UTILITY SHIFTING


153.71 153.71 0.00
CHARGES
8 TOTAL COST OF PROJECT 9204.53 9644.45 439.72
9 AMOUNT PUT TO TENDER = TOTAL COST - 2-3-4-7 8594.48
10 AMOUNT QUOTED BY CONTRACTOR 7900.00
11 TOTAL VALUE OF WORK DONE 501.26
12 TOTAL REMAINING AMOUNT AS PER 12% GST 7398.74
13 REMAINING AMOUNT AS PER GST WITH 18% 7842.66
14 VARIATION OF GST AMOUNT 443.92
15 TOTAL VARIATION ESTIMATE 883.65
AMOUNT AS PER DPR AMOUNT AS PER REVISED DPR VARIATION
TOTAL QTY
TOTAL QTY
S. No. DESCRIPTION OF WORK UNIT Rate AS PER Rate REMARKS
AS PER DPR
UPSOR DSR 2018 NSR REVISED DPR UPSOR DSR 2018 NSR IN AMOUNT

CIVIL WORK
(i) Cleaning jungle including up rooting of rank, vegetations grass,
push, wood trees and amplings of grith upto 30 cms. measured at
1 a height of 1 M. above ground level and removal of rubbish up Sqm 10512.44 3.20 33639.81 10859.55 3.20 34750.56
to a distance of 50M. out side the periphery of area cleared.

(a) Excavation in foundation in ordinary soil (Loam, clay or sand)


including lift upto 1.50 M. and lead upto 30 M. and including filling
watering and ramming of excavated earth into the trenches or into
the space between the building and the sides of foundation
2 Cum 10135.67 90.00 912209.87 10377.81 90.00 934002.47
trenches or into the plinth and removal and disposal of surplus
earth as directed by the Engineer-in charge upto a distance of 30
M. from the foundation trenches. (where machine can not move )

3 CARTED EARTH (UPTO 10 KM) Cu.M 1864.86 219.65 409615.98 1899.44 219.65 417211.48

(a) Sand filling in plinth and under floor including supply of


necessary quantity of sand from a distance not exceeding 8 Kms.
from the site of work and including watering, dressing etc. labour
4 Cum 1818.45 380.00 691010.40 1860.39 380.00 706947.60
and T&P etc. required for proper complition of the work. saplings
of girth upto 30 cms. measured at a height of 1 M. above ground
level and removal of rubbish upto a distance of 50 M. out side the
periphery of area cleared. including cost of sand.

Providing and injecting chemical for preconstruction anttermite


treatment and creating and chemical barrier under and around the
column pits wall trenches basement excavation top surface in
plinth filling junction of wall and floor, along the external per
meter of binding expansion joints surrounding or pipes and
conduit etc. complete (plinth area of the building at ground floor
only shall be measured as per I.S. 6313 (part II 1981) Aldrine
emulsifiable concentrate or any other approved material such as
5
heptachlor of chlordane will be used. The rate of application of
chemical emulsion shall be as follows :-
1.Treatment for massonary and foundation 5 liters per sqm.
2.Back fill in immediate contact with foundation 7.5 liters per sqm.
3.Treatment of surface of plinth filling 5 liters per sqm.
4.Treatment of soil along external perameter of Building 7.5 liters
per sqm
5. Treatment of soil under external parameter 5 liters per sqm.

sqm 12520.36 200.00 2504072.00 12867.47 200.00 2573494.00

Providing & applying a coat of residual petroleum bitumen of


grade of VG-10 of approved quality using 1.7kg per square metre
6 on damp proof course after cleaning the surface with brushes and sqm 384.99 110.00 42348.43 384.99 110.00 42348.43
finally with apiece of cloth lightly soaked in kerosene oil.

B SUB HEAD II : CONCRETE WORKS


Cement Concrete with 4 cm gauge approved stone ballast approved
course sand cement proportion of 8:4:1 include supply of all material and
1 Cum 1558.25 3030.00 4721511.92 1633.78 3030.00 4950361.76
T&P etc. required for proper completion of work

Making plinth protection 50mm thick of cement concrete 1:2:4 (1 cement


: 2 coarse sand (zone - III) : 4 graded stone aggregate 20 mm nominal
size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well
Sqm 1983.94 614.05 1218238.36 2026.40 614.05 1244310.92
rammed and consolidated and grouted with fine sand, including
necessary excavation, leveling & dressing & finishing the top smooth.
C SUB HEAD III : REINFORCED CEMENT CONCRETE WORK
Centering and shuttering including strutting, propping etc.
1
and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
a Sqm 5108.83 284.85 1455250.88 5238.21 284.85 1492104.77
Walls (any thickness) including attached pilasters, buttresses,
b Sqm 580.89 609.30 353935.06 580.89 609.30 353935.06
plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
c Sqm 17297.52 693.05 11988046.37 17367.13 693.05 12036289.59
Arches, domes, vaults up to 6 m span Sqm 249.25 1713.20 427015.10 318.86 1713.20 546270.95
Extra for shuttering in circular work (20% of respective centering
and shuttering items) Sqm

d Shelves (Cast in situ) Sqm 58.92 693.05 40834.51 58.92 693.05 40834.51
Lintels, beams, plinth beams, girders, bressumers and cantilevers
e Sqm 19886.58 552.05 10978387.13 20378.77 552.05 11250100.62
f Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 8884.11 733.70 6518269.31 9098.81 733.70 6675794.70
Weather shade, Chajjas, corbels etc., including edges Sqm
g Stairs, (excluding landings) except spiral-staircases Sqm 397.78 622.35 247558.38 418.97 622.35 260745.98
Small lintels not exceeding 1.5 m clear span, moulding as in
h cornices, window sills, string courses, bands, copings, bed plates, Sqm 850.56 284.85 242280.73 850.56 284.85 242280.73
anchor blocks and the like
i Edges of slabs and breaks in floors and walls
Under 20 cm wide mtr 1151.80 173.25 199549.35 1151.80 173.25 199549.35
j Weather shade, Chajjas, corbels etc., including edges Sqm 885.00 766.75 678573.75 901.79 766.75 691447.48
Extra for shuttering in circular work (20% of respective centering
K and shuttering items) 249.25 342.64 85403.02 318.86 342.64 109254.19

Extra for additional height in centering, shuttering where ever


required with adequate bracing, propping etc., including cost of de-
2 shuttering and decentering at all levels, over a height of 3.5 m, for
every additional height of 1 metre or part thereof (Plan area to be
measured).
Suspended floors, roofs, landing, beams and balconies (Plan area
Sqm 8678.80 287.50 2495155.00 8678.80 287.50 2495155.00
to be measured)

Add for plaster drip course/ groove in plastered surface or


3 metre 1180.00 58.90 69502.00 1180.00 58.90 69502.00
moulding to R.C.C. projections.

Steel reinforcement for R.C.C. work including straightening,


cutting,bending, placing in position and binding all complete upto
4
plinth level.Thermo-Mechanically Treated bars of grade Fe-500D
or more.
Thermo-Mechanically Treated bars of grade Fe-500D or more. Up
a kg 661563.50 70.81 46845311.44 676420.46 70.81 47897332.77
to plinth
Thermo-Mechanically Treated bars of grade Fe-500 D or more.
b kg 793737.83 70.81 56204575.43 815741.36 70.81 57762645.39
Above plinth

Providing and laying in position machine batched and machine


mixed design mix M-25 grade cement concrete for reinforced
cement concrete work, using cement content as per approved
design mix, including pumping of concrete to site of laying but
excluding the cost of centering, shuttering, finishing and
reinforcement, including admixtures in recommended proportions
5 as per IS: 9103 to accelerate, retard setting of concrete, improve
workability without impairing strength and durability as per
direction of Engineer-in-charge.
(Note :- The cement content considered in this item is @ 330
kg/cum. Excess/ less cement used as per design mix is
payable/recoverable separately).

a All works up to plinth level Cum 4830.74 8398.65 40571692.40 4936.86 8398.65 41462957.14
b All works above plinth level up to floor V level Cum 5764.36 9802.20 56503379.86 5921.53 9802.20 58043991.63

Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each
6 Cum 280.95 0.00 280.95 0.00
four floors or part thereof.

Providing and fixing in position Stainless steel Grade 304 plate-1.0


7
mm thick as per design for expansion joints.
a 200 mm wide. metre 675.20 711.90 480674.88 675.20 711.90 480674.88
b 300 mm wide. metre 1006.25 0.00 1006.25 0.00
Providing and fixing of expansion joint system related with floor
location as per drawings and direction of Engineer-In-Charge. The
joints system will be of extruded aluminum base members, self
aligning / self centering arrangement and support plates etc. as
per ASTM B221-02. The system shall be such that it provides
floor to floor /floor to wall expansion control system for various
vertical location in load application areas that accommodates multi
directional seismic movement without stress to it's components.
System shall consist of metal profiles with a universal aluminum
base member designed to accommodate various project
8 conditions and finish floor treatments. The cover plate shall be
designed of width and thickness required to satisfy projects
movement and loading requirements and secured to base
members by utilizing manufacturer’s pre-engineered self-
centering arrangement that freely rotates / moves in all directions.
The Self - centering arrangement shall exhibit circular sphere
ends that lock and slide inside the corresponding aluminum
extrusion cavity to allow freedom of movement and flexure in all
directions including vertical displacement.

Provision of Moisture Barrier Membrane in the Joint System to


have watertight joint is mandatory requirement all as per the
manufactures design and as approved by Engineer -in- Charge.
(Material shall confirm to ASTM 6063).
Floor Joint of 100 mm gap M 127.00 5594.85 710545.95 127.00 5594.85 710545.95

Providing and fixing of expansion joint system related with wall


joint (internal/ external) location as per drawings and direction of
Engineer-In- Charge. The joints shall be of extruded aluminum
base members, self aligning / centering arrangement and support
plates as per ASTM B221- 02. The material shall be such that it
provides an Expansion Joints System suitable for vertical wall to
wall/ wall to corner application, both new and existing construction
9
in office Buildings & complexes with no slipping down tendency
amongst the components of the Joint System. The Joint System
shall utilize light weight aluminum profiles exhibiting minimal
exposed aluminum surfaces mechanically snap locking the
multicellular to facilitate movement. (Material shall confirm to
ASTM 6063).

Wall Joint of 100 mm gap M 457.20 4658.30 2129774.76 457.20 4658.30 2129774.76

Providing and fixing of expansion joint system related with wall


joint (internal/ external) location as per drawings and direction of
Engineer-In- Charge. The joints shall be of extruded aluminum
base members, self aligning / centering arrangement and support
plates as per ASTM B221- 02. The material shall be such that it
provides an Expansion Joints System suitable for vertical wall to
wall/ wall to corner application, both new and existing construction
10
in office Buildings & complexes with no slipping down tendency
amongst the components of the Joint System. The Joint System
shall utilize light weight aluminum profiles exhibiting minimal
exposed aluminum surfaces mechanically snap locking the
multicellular to facilitate movement. (Material shall confirm to
ASTM 6063).

Roof Joint of 100 mm gap M 91.00 5193.45 472603.95 91.00 5193.45 472603.95

D SUB HEAD IV : BRICK WORK

First class bricks work in 1:6 in cement and fine sand of 1.25 cf
mortar in foundation and plinth including supply of all materials,
1 Cum 471.97 3900.00 1840682.81 483.71 3900.00 1886468.81
labor and T&P etc. required for completion of the work.

Brick work with non modular fly ash bricks conforming to


IS:12894, class designation 10 average compressive strength in
2
super structure above plinth level up to floor V level in :

Cement mortar 1:6 (1 cement : 6 Coarse sand) Cum 6687.44 7280.70 48689228.73 6852.08 7280.70 49887923.18

Extra for brick work / AAC block masonry / Tile brick masonry in
3 superstructure above floor V level, for each four floors or part Cum 0.00 236.65 0.00 0.00 236.65 0.00
thereof by mechanical means.

E SUB HEAD V : STEEL


M.S. or iron work in heavy sizes such as truss ,builty up gates
4 record rack roof work gates etc, including rivetting or welding qtl 164.94 6100.00 1006117.99 164.94 6100.00 1006117.99
where neceessory
13
M.S. or iron work of small sizes and section such as holding down
bolts, hold fast, tie rods grating etc. wrought to required from KG. 9758.20 61.50 600129.30 11180.74 61.50 687615.51
including supply of steel bolts, nuts wastage etc. and their fixing
required for proper completion of the work.

Providing and fixing M.S. Tubular frames for doors, windows,


ventilators
and cupboard with rectangular/ L-Type sections, made of 1.60 mm
thick M.S. Sheet, joints mitred, welded and grinded finish, with KG. 9413.01 137.30 1292406.27 9413.01 137.30 1292406.27
profiles of required size, including fixing of necessary butt hinges
and screws and applying a priming coat of approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement
concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse
sand : 6 graded stone aggregate 20 mm nominal size)

Providing and fixing stainless steel ( Grade 304) railing made of


Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required) and
fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories &
5 stainless steel dash fasteners , stainless steel bolts etc., of Kg 20380.32 575.45 11727852.27 20380.32 575.45 11727852.27
required size, on the top of the floor or the side of waist slab with
suitable arrangement as per approval of Engineer-in charge, (for
payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts,
fasteners etc.).

Providing and fixing carbon steel galvanised (minimum coating 5


micron) dash fastener of 10 mm dia double threaded 6.8 grade
(yield strength 480 N/mm2), counter sunk head, comprising of 10
mm dia polyamide PA 6 grade sleeve, including drilling of hole in
frame, concrete/ masonry, etc. as per direction of Engineer-in-
charge. (For railing)
10 x80 mm NO. 324.00 109.00 35316.00 324.00 109.00 35316.00

Supplying and fixing rollingSHUTTERS of approved make made


80x125mm (3"x5") cold rolled M.S. lath inter locked throughout
their entire length and joined together at the end by end locks and
mounted on specially designed pipe shaft with brackets, side 120.26 1550.00 186395.25 120.26 1550.00 186395.25
guides and arrangements for inside and outside locking with push
and pull operation complete but excluding the cost of top cover
and springs.
Providing and fixing 27.5cm long wire spring grade 2 for rolling
34.00 820.00 27880.00 34.00 820.00 27880.00
shutters.
providing and fixing top cover for rolling shutters 2.50 meter wide.
17.00 940.00 15980.00 17.00 940.00 15980.00
Providing and fixing ball bearing for rolling shutters. 34.00 880.00 29920.00 34.00 880.00 29920.00

F SUB HEAD VI : WOOD AND P. V. C. WORK


Providing and fixing factory made single extruded WPC (Wood
Polymer Composite) solid door/window/Ceosetory window s &
other Frames/Chowkhat comprising of virgin PVC polymer of K
value 58-60 (Suspension Grade), calcium carbonate and natural
fibers (wood powder/ rice husk/wheat husk) and non tox ic
additives (maximum toxicity index of 12 for 100 gms) fabricated
with miter jo ints after applying PVC solvent cement and screwed
with full body threaded star headed SS screws having
minimum f rame density of 750 kg/cum, screw withdrawal strength
of 2200 N (Face) & 1100 N (Edge) , minimum compressive
strength of 58 N/mm2, modulus of least icity 900 N/mm2 and
1 resistance to spread of flame of Class A category with property of
being termite/borer proof, water/moisture proof and fire retardant
and fixed in position with M.S hold fast/lugs/SS dash fa steners of
required dia and length complete as per direction of Engineer-In -
Charge . (M.S hold fast/lugs or SS dash fasteners shall be paid for
separate ly).
Note: For WPC solid door/window frames , minus 5mm tolerance
in dimensions i.e. depth and width of profile shall be acceptable .
Variation in profile dimensions on plus side shall be acceptable le
but no extra payment on this account shall be made.

Frame size 65 x 150 mm mtr 4031.85 1543.80 6224370.03 4031.85 1543.80 6224370.03

Melamine polishing on wood work (one or more coat). sqm 78.20 110.75 8660.87 78.20 110.75 8660.87

Supply & fixing of 4.5 Cm. thick teak wood part panelled and part
glazed door and window shutter including supply & fixing of
wooden cleats and stops and including fixing & adjustment of
hinges, bolts, locks, handles spring and or other fittings but
excluding their supply and including painting with two coats of
black Japan on all iron fitting if necessary. Including fixing the
glass panes with putty for bradglass and glass to be 4 mm. thick.
Fitting with necessary screws to be supplied by the deptt.(For
Main Entrance door)

As in item no. 409 above but fully panelled. 59.46 4550.00 270543.00 59.46 4550.00 270543.00

Supply and fixing of flush Doors commercial quality conforming


to I.S 2202 Part 1(1983) including fixing of wooden class and
stoppers and including fixing and adjustment of hinges, bolts,
2
handles, springs fitting with necessary screws complete.

35 mm thick including ISI marked Stainless Steel butt hinges


sqm 2058.89 3023.95 6225980.42 2083.34 3023.95 6299915.99
with necessary screws

3 (D) For double leaf shutters add extra in over all rates sqm 478.90 200.00 95779.00 478.90 200.00 95779.00

Extra for providing vision panel not exceeding 0.1 sqm in all type
4 of flush doors (cost of glass excluded) (overall area of door shutter
to be measured):
Rectangular or square Sqm 712.21 173.95 123889.36 712.21 173.95 123889.36

Extra for providing lipping with 2nd class teak wood battens 25
5 mm minimum depth on all edges of flush door shutters (over all 509.22 401.40 204398.90 533.67 401.40 214213.13
area of door shutter to be measured).

6 Providing and fixing curtain rods of 1.25 mm thick chromium


plated brass plate, with two chromium plated brass brackets fixed
with C.P. brass screws and wooden plugs, etc., wherever necessary
complete :
25 mm dia. Metre 1228.15 480.15 589696.22 1228.15 480.15 589696.22

7
Providing and fixing M.S. grills of required pattern in frames of
windows etc. with M.S. flats,square or round bars etc. including
priming coat with approved steel primer all complete.
Fixed to steel windows by welding KG 41470.17 165.3 6855019.10 41470.17 165.30 6855019.10
8
Providing and fixing aluminium extruded section body tubular type
universal hydraulic door closer (having brand logo with ISI, IS :
each 1483.00 851.60 1262922.80 1483.00 851.60 1262922.80
3564, embossed on the body, door weight upto 36 kg to 80 kg and
door width from 701 mm to 1000 mm) with double speed
adjustment with necessary accessories and screws etc. complete.

9 Providing and fixing aluminium sliding door bolts ISI marked


anodised (anodic coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour or shade with nuts
and screws etc. complete :
300x16 mm each 846.00 150.00 126900.00 856.00 150.00 128400.00

10 Providing and fixing aluminium tower bolts ISI marked anodised


(anodic coating not less than grade AC 10 as per IS : 1868 )
transparent or dyed to required colour or shade with necessary
screws etc. complete :
250x10 mm each 1664.00 52.00 86528.00 1674.00 52.00 87048.00
150x10 mm each 1990.00 43.00 85570.00 1990.00 43.00 85570.00

11 Providing and fixing aluminium handles ISI marked anodised


(anodic coating not less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour or shade with necessary
screws etc. complete:
125mm each 1813.00 48.00 87024.00 1832.00 48.00 87936.00
100mm each 1982.00 33.00 65406.00 1832.00 33.00 60456.00

12 Providing and fixing aluminium hanging floor door stopper ISI


marked anodised (anodic coating not less than grade AC 10 as per
IS : 1868) transparent or dyed to required colour and shade with
necessary screws etc. complete.
Twin rubber stopper each 1034.00 62.05 64159.70 1044.00 62.05 64780.20

14 Providing and fixing bright finished 100mm mortice lock with 6


levers without pair of handles for aluminium door with necessary
each 705.00 637.05 449120.25 705.00 637.05 449120.25
screws etc complete (Best make of approved quality) as per
direction of Engineer-in-charge.

15 Providing and fixing fly proof stainless steel grade 304 wire gauge,
to windows and clerestory windows using wire gauge with average
width of aperture 1.4 mm in both directions with wire of dia. 0.50
mm all complete.
With 12 mm mild steel U beading. Sqm 1786.34 1001.50 1789014.50 1786.34 1001.50 1789014.50

Providing and fixing 2nd class teak wood lipping/ moulded beading
or taj beading of size 18X5 mm fixed with wooden adhesive of
16 approved quality and screws/ nails on the edges of the Pre- MTR. 1976.40 78.85 155839.14 1976.40 78.85 155839.14
laminated particle board as per direction of Engineer-in-charge.

Providing and fixing wire gauge shutters using stainless steel


grade 304 wire gauge with wire of dia 0.5 mm and average width
of aperture 1.4 mm in both directions for doors, windows and
clerestory windows with necessary screws :
Second class teak wood
MTR. 42.10 4352.20 183227.62 42.10 4352.20 183227.62

Providing and fixing fire resistant door frame of section 50 x 60


mm on horizontal side & 35 x 60 mm on vertical sides having built
in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not
less than 120gm/ m²) suitable for mounting 120 min Fire Rated
Glazed Door Shutters. The frame shall be filled with Mineral wool
Insulation having density min 96Kg/m³ . The frame will have a
provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style
17 & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the mtr 369.30 1512.95 558732.44 373.32 1512.95 564814.49
opening along with Factory made Template for SS Ball Bearing
Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter .
The frame shall be finished with a approved fire resistant primer or
Powder coating of not less than 30 micron in desired shade as per
the directions of Engineer - in- charge . (Cost of SS ball bearing
hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door
shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or
EN1634-1:1999, tested and certified as per laboratory approved
by Engineer-in-charge, with suitable mounting on door frame,
consisting of vertical styles, top rail & side rail 60 mm x 60 mm
wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick
G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral
18 sqm 71.70 8379.30 600795.81 71.70 8379.30 600795.81
wool insulation having density min 96 kg/ m³ and fixing with
necessary stainless steel ball bearing hinges of size 100x89x3mm
of approved make, including applying a coat of approved fire
resistant primer or powder coating not less than 30 micron etc all
complete as per direction of Engineer-in-charge (panelling to be
paid for seperately).

Providing and fixing glazing in fire resistant door shutters, fixed


panels & partitions etc., with G.I. beading made out of 1.6 mm
thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x
33 mm screwed with M4 x 38 mm SS screws at distance 75 mm
from the edges and 150 mm c/c , including applying a coat of
approved fire resistant primer/ powder coating of not less than 30
micron on G.I. beading, & special ceramic tape of 5 x 20 mm size
etc complete in all respect as per NBC 2016, IS 16231 (Part
3):2016 and as per direction of Engineer-incharge with glass of
required thickness having 120 minutes of fire resistance both
19 integrity & radiation control (EW120) and minimum 20 minutes of sqm 132.65 39395.30 5225589.57 132.65 39395.30 5225589.57
insulation (EI20). The manufacturer have to give test
report/certification of fire glass and the glass should have the
stamp showing the value of E, EW & EI. The glass shall be tested
in approved NABL accredited lab or by any other accreditation
body which operates in accordance with ISO/IEC 17011 and
accredits labs as per ISO/IEC 17025 for testing and calibration
scopes shall be eligible. The maximum glazing size shall not be
more than 1100x2200 mm (w x h) or 2.42 sqm.

Providing and fixing panic bar / latch (Double point) fitted with a
single body, Trim Latch & Lock on back side of the Panic Latch of
20 each 88.00 7134.85 627866.80 88.00 7134.85 627866.80
reputed brand and manufacture to be approved by the Engineer-
in- charge, all complete.

Providing & Fixing decorative high pressure laminated sheet of


plain / wood grain in gloss / matt/ suede finish with high density
21 protective surface layer and reverse side of adhesive bonding
quality conforming to IS : 2046 Type S, including cost of adhesive
of approved quality.
1.0 mm thick sqm 0.00 717.65 0.00 0.00 717.65 0.00

Providing and fixing cup board shutters 25 mm thick, with Pre-


laminated flat pressed three layer particle board or graded wood
particle board IS: 12823 marked, exterior grade (Grade l Type ll),
having one side decorative lamination and other side balancing
22 sqm 145.35 1928.90 280371.40 145.35 1928.90 280371.40
lamination, including IInd class teak wood lipping of 25 mm wide
x12 mm thick with necessary screws and bright finished stainless
steel piano hinges, complete as per direction of the Engineer-in-
Charge

Providing and fixing 50 mm bright finished brass cup board or


23 wardrobe knob with necessary screws (best make of approved 36.00 62.70 2257.20 36.00 62.70 2257.20
quality)
Providing & fixing of windows made of pre-painted steel (Base
steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per
IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of
5-7 microns thick, finish painted with a polyester paint of 12-16
microns thick and back coated with 5-7 microns thick alkyd
backer. Section for outer frame should be of 72x55mm, centre
mullion should be of 72x50mm, section for fixed glass beading
should be of 12x12mm and section for shutter should be of 47 x
20mm . Outer frame & mullion sections to have rebate for glazed
shutters, WITH fly mesh and 20 mm provision for guard bars/
grills fly mesh shutter section should be of 20x40mm. The
24 KG 129.25 7911.00 1022457.20 129.25 7911.00 1022457.20
sections are to be cut to length mitre joined with corner bracket.
Centre mullions to be fixed with mullion cap. Elixir or equivalent
stay, handles 2nos of heavy duty stain less steel pivot hinges
shall be provided per shutter. The windows should be paneled with
4 mm thick plain float glass and S.S. Mesh for fly mesh shutter
(304 grade). Rubber Gaskets are provided all around the glass.
The above frames should be fixed to the concrete/masonry wall by
means of self expanding screws. Including 10mm square guard
bars with 6” (152.4mm) pitch, complete for finished item of work.

Two track two panels sliding door made of (big series) frame
67 x 50 mm & sash 46 x 82 mm both having wall thickness
SQM 152.21 6005.00 914021.05 152.21 6005.00 914021.05
of 2.3 ± 0.2 mm and single glazing bead / double glazing
bead of appropriate dimension.

Providing and fixing pressed steel door frames confirming to IS:


4351 manufactured from commercial mild steel sheet of 1.25 mm
thickness including hinges jamb, lock jamb, bead and if required
angle threshold of mild steel angle of section 50x25mm, or base
ties of 1.25mm pressed mild steel welded or rigidly fixed together
by mechanical means, adjustable lugs with split end tail to each RMT. 100.35 473.80 47545.83 100.35 473.80 47545.83
jamb including steel butt hinges 2.5mm thick with mortar guards,
lock strike-plate and shock absorbers as specified and applying a
coat of approved steel primer after pre-treatment of the surface as
directed PROFILE -E

Providing and fixing carbon steel galvanised (minimum coating 5


micron) dash fastener of 10 mm dia double threaded 6.8 grade
(yield strength 480 N/mm2), counter sunk head, comprising of 10
27.00 109.00 2943.00 27.00 109.00 2943.00
mm dia polyamide PA 6 grade sleeve, including drilling of hole in
frame, concrete/ masonry, etc. as per direction of Engineer-in-
charge.

F SUB HEAD VII :FLOORING


Providing and fixing 18mm thick gang saw cut mirror polished
premoulded and prepolished) machine cut for kitchen platforms,
vanity counters, window sills , facias and similar locations of
required size of approved shade, colour and texture laid over
20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand)
1
with joints treated with white cement, mixed with matching
pigment, epoxy touch ups, including rubbing, curing, moulding and
polishing to edges to give high gloss finish etc. complete at all
levels.

Granite of any colour and shade


Area of slab over 0.50 sqm Sqm 822.43 4007.65 3296011.59 822.43 4007.65 3296011.59

Providing and laying flamed finish Granite stone flooring in


required design and patterns, in linear as well as curvilinear
portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick
base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and
jointed with cement slurry and pointing with white cement slurry
308.74 2476.45 764574.22 376.59 2476.45 932601.35
admixed with pigment of matching shade including rubbing, curing
and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge :
11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red,
Elite Brown, Cat Eye or equivalent.

Providing edge moulding to 18 mm thick marble stone counters,


Vanities etc., including machine polishing to edge to give high
2 gloss finish etc. complete as per design approved by Engineer-in-
Charge.

Granite work MTR 422.88 673.25 284703.96 422.88 673.25 284703.96


Extra for fixing marble /granite stone, over and above
corresponding basic item, in fascia and drops of width up to 150
3 MTR 194.06 434.25 84270.56 194.06 434.25 84270.56
mm with epoxy resin based adhesive, including cleaning etc.
complete.

Extra for providing opening of required size & shape for wash
basin/ kitchen sink in kitchen platform, vanity counter and similar
4 location in marble/ Granite/ stone work, including necessary holes Each 179.00 734.55 131484.45 179.00 734.55 131484.45
for pillar taps etc. including moulding, rubbing and polishing of cut
edges etc. complete.

25 mm wooden planking, tongued and grooved in flooring,


5 including fixing
with iron screws complete with :
Second class teak wood Sqm 68.29 4152.45 283562.51 68.29 4152.45 283562.51
Providing and fixing of ‘Optra Acoustical Wall Panelling’ with
square edges made of fibre glass substrate 25mm thick and
wrapped on the front side with an acoustically transparent and
classified for Fire reaction ASTM E-84 : Class A fabric with an
option of colors – Husk JT-06, Copper JT-13, Sangria JT-17,
Sesame VL-27B, Coffee VL-08N, Charcoal JT-14, Titanium JT-07,
Flame JT-16, Peanut JT-12, Shell VL-22 as per the choice of the
Architect of size 600X600/1200/1800 mm providing a minimum
sound absorption level of 0.85 NRC to be affixed to wall using
Wall panel impalers supplied by M/s of Industries India Pvt Ltd
and construction adhesives as per the instructions laid down by
6 the manufacturer. Sqm 115.92 4152.45 481352.00 115.92 4152.45 481352.00

INSTALLATION:
3/4/5 nos. of wall panel Impalers of shall be fixed to the wall
surface using self-tapping screws. Silica based construction
adhesive to be dabbed on to the projecting elements (spikes) of
the impalers. of Optra wall panels shall be pierced through the
spikes of the impalers ensuring the line and level of the panels are
maintained.
Installation to be carried out by of Trained Installation team &
Installation should be carried out as per of recommended
procedure.

Providing and laying Polished Granite stone flooring in required


design and patterns, in linear as well as curvilinear portions of the
building all complete as per the architectural drawings with 18 mm
thick stone slab over 20 mm (average) thick base of cement
7 mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement
slurry and pointing with white cement slurry admixed with pigment
of matching shade including rubbing , curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge.

Polished Granite stone slab jet Black, Cherry Red, Elite Brown,
Sqm 6546.52 3526.60 23086955.10 6546.52 3526.60 23086955.10
Cat Eye or equivalent.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown,
Sqm 64.35 2476.45 159359.56 64.35 2476.45 159359.56
Cat Eye or equivalent.

Extra for pre finished nosing to treads of steps of marble/granite


8 metre 1288.80 530.25 683386.20 1288.80 530.25 683386.20
stone.

Providing and fixing Ist quality ceramic glazed wall tiles conforming
to
IS: 15622 (thickness to be specified by the manufacturer), of
approved
make, in all colours, shades except burgundy, bottle green, black
of
any size as approved by Engineer-in-Charge, in skirting, risers of
steps Sqm 1472.16 1030.30 1516766.45 1472.16 1030.30 1516766.45
and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement :
3
coarse sand) and jointing with grey cement slurry @ 3.3kg per
sqm,
including pointing in white cement mixed with pigment of
matching shade
complete.
Providing and fixing 1st quality ceramic glazed floor tiles
conforming to
IS : 15622 (thickness to be specified by the manufacturer ) of
approved
make in all colours, shades except burgundy, bottle green, black of
any
size as approved by Engineer-in-Charge in skirting, risers of steps Sqm 1736.60 927.90 1611386.50 1736.60 927.90 1611386.50
and
dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3
coarse
sand) and jointing with grey cement slurry @ 3.3kg per sqm
including
pointing in white cement mixed with pigment of matching shade
complete.

Supply and fixing 6 mm. (¼") China white glazed tiles in flooring or
in skirting or dado laid with 1:3 Cement and approved coarse sand
9 mortar finished with white cement slurry, jointing and polishing 1919.80 900.00 1727822.70 1944.77 900.00 1727822.70
complete, including supply of all materials, labour and Tools and
Plants.

Providing and laying matt finished vitrified tile of size


100x100x16mm having water absorption less than 0.5% and
conforming to IS: 15622 of approved make in all colours and
shades in out door floors such as footpath, court yard multi
Sqm 557.12 1933.75 1077330.80 557.12 1933.75 1077330.80
models etc., laid on 20mm thick baseof cement mortar 1:4
(1cement : 4 coarse sand) in all shapes &patterns including
grouting the joints with white cement mixed withmatching
pigments etc. complete as direction of Engineer-in-Charge
Providing and laying matt finished vitrified tile of size
100x100x16mm having water absorption less than 0.5% and
conforming to IS: 15622 of approved make in all colours and
shades in out door floors such as footpath, court yard multi
Sqm 5.63 1264.80 7120.82
models etc., laid on 20mm thick baseof cement mortar 1:4
(1cement : 4 coarse sand) in all shapes &patterns including
grouting the joints with white cement mixed withmatching
pigments etc. complete as direction of Engineer-in-Charge

Supply and fixing of Kota stone in floor ing 20 mm thick and joint
filled with 1:2 cement and coarse sand with approved colouring
materials to be given an even shade with 12 mm base coat
(bedding) of 1:2 cement & coarse sand morter and polished by
10 Sqm 2395.82 900.00 2156238.00 2531.81 900.00 2278629.00
hand or machine and finally finished with french manson polish or
other approved polish including supply of all materials, labour,
Tools & plants etc. required for proper completion of the work.

Supply and fixing 10 to 12 mm thick Kota stone tiles in skirting or


dado laid with 1:2 cement and approved coarse sand morter
finished with in its cement colour slurry, jointing and polished of
11 577.84 880.00 508494.80 581.73 880.00 511918.00
approved quality complete, including supply of all materials,
labour, tools and plants etc. required for proper completion of the
work.

Supply and fixing 6 mm. (¼") China white glazed tiles in flooring or
in skirting or dado laid with 1:3 Cement and approved coarse sand
12 mortar finished with white cement slurry, jointing and polishing 1272.43 900.00 1145187.90 1372.82 900.00 1235538.90
complete, including supply of all materials, labour and Tools and
Plants.

Providing and laying double charged vitrified floor tiles in different


sizes (thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades, laid on 20mm thick
13
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey
cement slurry @ 3.3kg/sqm including grouting the joints with white
cement and matching pigments etc., complete.

Size of Tile 600x600 mm Sqm 2544.26 1500.55 3817791.22 2544.26 1500.55 3817791.22
Size of Tile 800x800 mm Sqm 4456.29 1758.70 7837277.22 4456.29 1758.70 7837277.22
Providing and laying Vitrified tiles in different sizes (thickness to
be specified by manufacturer), with water absorption less than
0.08 % and conforming to I.S. 15622, of approved make, in all
colours & shade, in skirting, riser of steps, over 12 mm thick bed
Sqm 333.86 1758.70 587159.58 333.86 1758.70 587159.58
of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey
cement slurry @ 3.3kg/sqm including grouting the joint with white
cement & matching pigments etc. complete.

Size of Tile 800x800 mm

Providing and laying Vitrified tiles in different sizes (thickness to


be specified by manufacturer), with water absorption less than
0.08 % and conforming to I.S. 15622, of approved make, in all
colours & shade, in skirting, riser of steps, over 12 mm thick bed
Sqm
of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey
cement slurry @ 3.3kg/sqm including grouting the joint with white
cement & matching pigments etc. complete.

Size of Tile 600x600 mm 366.19 1400.00 512666.00

2.5 cm (1") thick 1:2:4 plain cement concrete floor with cement,
approved coarse sand and 2 cm. (1") graded approved stone grit,
laid in panels finished with 3 mm. (1/8") floating coat of neat
cement of cement and marble dust in ratio 5:1 as specified over
and including 8 cm (3") thick base concrete consisting of cement,
fine sand of 1.25 fineness modulus and brick ballast 4 cm. (1½") 152.06 50.00 7603.13 152.06 50.00 7603.13
gauge in the proportion of 1:4:8 and removing any overlapping
mortar at the joints of the penals if any and giving them a uniform
finish, including supply of all materials, labour, Tools & plants etc.
required for proper completion of the work.

G SUB HEAD VIII :ROOFING


Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 stone aggregate 10 mm and down gauge),
1 including finishing with cement mortar 1:3 (1 cement : 3 fine sand)
as per standard design :

In 75x75 mm deep chase mtr 1161.93 237.25 275667.89 1204.39 237.25 285741.53

Making khurras 45x45 cm with average minimum thickness of 5


cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1
2 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 each 166.00 244.05 40512.30 170.47 244.05 41603.20
cement : 3 coarse sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet complete.

Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300


mm x 20 mm) with SRI (solar refractive index) > 78, solar
reflection
> 0.70 and initial emittance > 0.75 on waterproof and sloped
surface
of terrace, laid on 20 mm thick cement sand mortar in the ratio of
1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of
white cement & marble powder in ratio of 1:1, including rubbing
3 and each 3861.62 1374.10 5306252.04 3861.62 1374.10 5306252.04
polishing of the surface upto 3 cuts complete, including providing
skirting upto 150 mm height along the parapet walls in the same
manner.

H SUB HEAD IX : FINISHING WORK


1 12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand) Sqm 41051.86 263.55 10819218.78 42001.36 263.55 11069459.51

15 mm cement plaster on the rough side of single or half brick wall


2 of mix :

1:6 (1 cement: 6 fine sand) Sqm 28196.54 303.90 8568927.90 28723.27 303.90 8729001.15

6 mm cement plaster of mix :


3
1:3 (1 cement : 3 fine sand) Sqm 14047.03 227.35 3193591.99 14681.90 227.35 3337929.69
Providing wall putty on New surface with approvel quality
4 Sqm 77166.02 67.00 5170123.41 82817.00 67.00 5548739.07
material of Berger/J.K./Birla or similar make 2 coats

Wall painting with plastic emulsion paint of approved brand and


5 manufacture to give an even shade:

One or more coats on old work Sqm 53841.10 84.65 4557648.77 55425.46 84.65 4691764.85

6 Graniza (Natural Finish- 5 Shades) Sqm 3246.01 1399.45 4542621.70 3310.19 1399.45 4632438.40

Finishing walls with textured exterior paint of required shade :


7
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and
including priming coat of exterior primer applied @ 2.20kg/10 sqm Sqm 13953.61 232.00 3237237.11 14480.34 232.00 3359438.47

Distemper one coat with oil bound distemper of approved brand


manufacture and required shade on decoreted wall surfaces to
give an even shade over and including a priming coat with cement
primer of approved brand and manufacture such as of british,
shalimar, asian paints after throughly brushing surface free from Sqm 13250.60 78.00 1033547.06 13250.60 78.00 1033547.06
mortar droppings and other foreign matter and also including
preparing the surface even also sand prepared smooth including
cost of all materials. As in item no. 649 above but for every coat
after the first coat.

Finishing wall with water proof cement paint of approved make


and quality on new work with two coat to give an even shade
Sqm 752.26 83.00 62437.58 752.26 83.00 62437.58
including supply of all materials, labour, Tools & plant etc.
required for proper completion of the work.

Painting or varnishing with valsper or other approved high grade


enamel or super par synthetic clean varnish complete one coat
over previously painted surface including supply of all materials, Sqm 709.97 69.00 48987.59 709.97 69.00 48987.59
labour, Tools & plants etc. required for proper completion of the
work. Paint to be used ISI Marked.

Painting wood work with Deluxe Multi Surface Paint of required


shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under
Sqm 490.84 130.25 63932.17 490.84 130.25 63932.17
coat of primer applied @0.75 ltr/10 sqm of approved brand and
manufacture

I SUB HEAD X : ALUMINIUM WORK


Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard tubular
sections/ appropriate Z sections and other sections of approved
make conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up
the gaps at junctions, i.e. at top, bottom and sides with required
EPDM rubber/ neoprene gasket etc. Aluminium sections shall be
1
smooth, rust free, straight, mitred and jointed mechanically
wherever required including cleat angle, Aluminium snap beading
for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of
Engineer-in-charge. (Glazing, paneling and dash fasteners to be
paid for separately) :

For fixed portion


Anodised aluminium (anodised transparent or dyed to required
shade according to IS: 1868, Minimum anodic coating of grade Kg 10557.05 423.95 4475662.41 10885.91 423.95 4615082.60
AC 15)

For shutters of doors, windows & ventilators including providing


and fixing hinges/ pivots and making provision for fixing of fittings
wherever required including the cost of EPDM rubber / neoprene
gasket required (Fittings shall be paid for separately)

Anodised aluminium (anodised transparent or dyed to required


shade according to IS: 1868, Minimum anodic coating of grade kg 3721.81 513.40 1910775.97 3721.81 513.40 1910775.97
AC 15)
Anodised aluminium (anodised transparent or dyed to required
shade according to IS: 1868, Minimum anodic coating of grade kg 149.47 546.35 81662.93 149.47 546.35 81662.93
AC 15)
Providing and fixing glazing in aluminium door, window, ventilator
shutters and partitions etc. with EPDM rubber / neoprene gasket
etc. complete as per the architectural drawings and the directions
2
of Engineer-in-charge . (Cost of aluminium snap beading shall be
paid in basic item):

With float glass panes of 5.50 mm thickness Sqm 4474.63 1296.40 5800907.09 4525.22 1296.40 5866491.97

Providing and fixing carbon steel galvanised ( minimum coating 5


micron) dash fastener of 10 mm dia double threaded 6.8 grade
(yield strength 480 N/mm2), counter sunk head, comprising of 10
Sqm 942.41 134.25 126518.88 990.41 134.25 132962.88
mm dia polyamide PA 6 grade sleeve, including drilling of hole in
frame , concrete/ masonry, etc. as per direction of Engineer-in-
charge. 10 x 120 mm

Filling the gap in between aluminium frame & adjacent RCC/


Brick/ Stone work by providing weather silicon sealant over backer
3 rod of approved quality as per architectural drawings and direction
of Engineer-in-charge complete.

Up to 5mm depth and 5 mm width M 1188.60 79.45 94434.27 1188.60 79.45 94434.27

Providing and fixing 12 mm thick frameless toughened glass door


shutter of approved brand and manufacture, including providing
and fixing top & bottom pivot & spring type fixing arrangement and
4 making necessary holes etc. for fixing required door fittings, all Sqm 26.33 4447.90 117131.00 28.41 4447.90 126382.63
complete as per direction of Engineer-in-charge (Door handle,
lock and stopper etc. to be paid separately).

J SUB HEAD XI : WATER PROOFING

Providing and laying "brick coba" 12mm thick laid with M-150
class brick bat coba 7.50 cm thick with gap of 15mm to each
other, over 20mm thick base of cement mortar 1:4 cement and
coarse sand mixed with water proofing compound spreading
cement slurry mixed with aerelic cement concrete water proofing
compound filled gaps of coba & top of coba mortar mixed with
water proofing compound in 1:4 cement and coarse sand mortar
finished smooth & top mashed false square 30cm x cm and side 7551.55 910.00 6871909.59 7884.19 910.00 7174611.99
wall parapet shall be mono tythic plaster wall upto 30 cm higher
and junction and corner shall be rounded by brick ballast cement
and coarse sand masonary Coba with top finished plaster mixed
with acetic water proofing compound @ 2% by weight & including
S/o all material, labour, T&P etc complete for proper completion of
work.

Providing and laying integral cement based water proofing


treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc consisting of following
operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of
cement admixed with water proofing compound conforming to IS.
2645 and approved by Engineer-in-charge over the RCC slab
5 including adjoining walls upto 300 mm height including cleaning
the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25
mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5
coarse sand) admixed with water proofing compound conforming
to IS : 2645 and approved by Engineer-in-charge over 20 mm thick
layer of cement mortar of mix 1:5 (1 cement :5 coarse sand)
admixed
with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge to required slope and treating
similarly the adjoining walls upto 300 mm height including
rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of
cement slurry using 2.75 kg/ sqm of cement admixed with water
proofing compound conforming to IS : 2645 and approved by
Engineerin-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar
of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineerin-
charge including laying glass fibre cloth of approved quality in top
layer of plaster and finally finishing the surface with trowel with
neat cement slurry and making pattern of 300x300 mm square 3
mm deep
(e) The whole terrace so finished shall be flooded with water for a
minimum period of two weeks for curing and for final test. All
above operations to be done in order and as directed and
specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at
Sqm 3891.62 1398.50 5442430.57 3891.62 1398.50 5442430.57
khurra as 65 mm.
Providing and laying water proofing treatment to vertical and
horizontal surfaces of depressed portions of W.C., kitchen and the
like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with
6
water proofing compound conforming to IS 2645 in recommended
proportions including rounding off junction of vertical and
horizontal surface.

(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse


sand) mixed with water proofing compound in recommended
proportion including rounding off junction of vertical and horizontal
surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot Sqm 2186.37 705.70 1542918.94 2186.37 705.70 1542918.94
at 1.7 kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints
of PVC sheet should be 100 mm wide and pasted to each other
with bitumen @ 1.7 kg/ sqm).

Providing and laying broken AAC Block in sunken portion of W.C.


& kitchen. These broken Block mixed with cement mortar 1:8 ( 1
cement : 8 coarse sand) laid and compacted properly including Cum 429.75 3861.00 1659254.13 429.75 3861.00 1659254.13
supply of labour, material, and tools and plant etc. as per
instruction of Engineer-in-charge

Supplying and Stacking Filling sunken floor with over burnt jhama
brick aggregate 120mm to 40mm including compacting of
7 Cum 158.60 819.85 130030.26 158.60 819.85 130030.26
materials complete as specified and directed for all levels.

SUB HEAD XII : STRUCTURAL GLAZING ALUMINIUM


K
COMPOSITE PANEL
Providing and supplying aluminium extruded tubular and other
aluminium sections as per the architectural drawings and
approved shop drawings , the aluminium quality as per grade
6063 T5 or T6 as per BS 1474,including super durable powder
coating of 60-80 microns conforming to AAMA 2604 of required
1 colour and shade as approved by the Engineer-in-Charge. (The Kg 2896.97 370.45 1073181.97 3354.62 370.45 1242718.42
item includes cost of material such as cleats, sleeves, screws etc.
necessary for fabrication of extruded aluminium frame work.
Nothing extra shall be paid on this account).

For shutters of doors, windows & ventilators including


providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost
of EPDM rubber / neoprene gasket required (Fittings
shall be paid for separately)
Powder coated aluminium (minimum
103.09 546.35 56322.35 131.88 546.35 72051.76
thickness of powder coating 50 micron)
Designing, fabricating, testing, protection, installing and fixing in
position semi (grid) unitized system of structural glazing (with open
joints) for linear as well as curvilinear portions of the building for
all heights and all levels, including:
(a) Structural analysis & design and preparation of shop drawings
for the specified design loads conforming to IS 875 part III (the
system must passed the proof test at 1.5 times design wind
pressure without any failure), including functional design of the
2
aluminum sections for fixing glazing panels of various
thicknesses, aluminium cleats, sleeves and splice plates etc.
gaskets, screws, toggles, nuts, bolts, clamps etc., structural and
weather silicone sealants, flashings, fire stop (barrier)- cum-smoke
seals, microwave cured EPDM gaskets for water tightness,
pressure equalisation & drainage and protection against fire
hazard including:

(b) Fabricating and supplying serrated M.S. hot dip galvanised /


Aluminium alloy of 6005 T5 brackets of required sizes, sections
and profiles etc. to accommodate 3 Dimensional movement for
achieving perfect verticality and fixing structural glazing system
rigidly to the RCC/ masonry/structural steel framework of building
structure using stainless steel anchor fasteners/ bolts, nylon
separator to prevent bimetallic contacts with nuts and washers
etc. of stainless steel grade 316, of the required capacity and in
required numbers.
(c) Providing and filling, two part pump filled, structural silicone
sealant and one part weather silicone sealant compatible with the
structural silicone sealant of required bite size in a clean and
controlled factory / work shop environment , including double
sided spacer tape, setting blocks and backer rod, all of approved
grade, brand and manufacture, as per the approved sealant
design, within and all around the perimeter for holding glass

(d) Providing and fixing in position flashings of solid aluminium


sheet 1 mm thick and of sizes, shapes and profiles, as required as
per the site conditions, to seal the gap between the building
structure and all its interfaces with curtain glazing to make it
watertight.
(e) Making provision for drainage of moisture/ water that enters
the curtain glazing system to make it watertight, by incorporating
principles of pressure equalization, providing suitable gutter
profiles at bottom (if required), making necessary holes of
required sizes and of required numbers etc. complete. This item
includes cost of all inputs of designing, labour for fabricating and
installation of aluminium grid, installation of glazed units, T&P,
scaffolding and other incidental charges including wastages etc.,
enabling temporary structures and services, cranes or cradles etc.
as described above and as specified. The item includes the cost
of getting all the structural and functional design including shop
drawings checked by a structural designer, dully approved by
Engineer-in-charge. The item also includes the cost of all mock
ups at site, cost of all
samples of the individual components for testing in an approved
laboratory, field tests on the assembled working structural glazing
as specified, cleaning and protection till the handing over of the
building for occupation. In the end, the Contractor shall provide a
water tight structural glazing having all the performance
characteristics etc. all complete as required, as per the
Architectural drawings, as per item description, as specified, as
per the approved shop drawings and as directed by the Engineer-
in-Charge.
Note:- 1. The cost of providing extruded aluminium frames,
shadow boxes, extruded aluminium section capping for fixing in
the grooves of the curtain glazing and vermin proof stainless steel
wire mesh shall be paid for separately under relevant items under
this sub- head. However, for the purpose of payment, only the
actual area of structural glazing (including width of grooves ) on
the external face shall be measured in sqm. up to two decimal
places. Note:- 2. The following performance test are to be
conducted on structural glazing system if area of structural glazing
exceeds 2500 Sqm from the certified laboratories accreditated by
NABL(National Accreditation Board for Testing and Calibration
Laboratories), Department of Science & Technologies, India. Cost
of testing is payable separately. The NIT approving authority will
decide the necessity of testing on the basis of cost of the work,
cost of the test and importance of the work. Performance Testing Sqm 658.10 2949.30 1940919.58 658.10 2949.30 1940919.58
of Structural glazing system Tests to be conducted in the NBL
Certified laboratories (1) Performance Laboratory Test for Air
Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per
ASTM E-283-04 testing method for a range of testing limit 1 to
200 mVhr (2) Static Water Penetration Test. (50pa to 1500pa) as
per ASTME- 331-09 testing method for a range up to 2000 ml.(3)
Dynamic Water Penetration (50pa to 1500pa) as per AAMA
501.01- 05 testing method for a range up to 2000 ml (4) Structural
Performance Deflection and deformation by static air pressure test
(1.5 times desing wind pressure without any failure) as per
ASTME-330-10 testing method for a range up to 50 mm (5)
Seismic Movement Test (up to 30 mm) as per AAMA501.4-09
testing method for Qualitative test. Tests to be conducted on site.
(6) Onsite Test for Water Leakage for a pressure range 50 kpa to

Providing and supplying Spandrel Glass Panels comprising of 6


mm
thick heat strengthened monolithic float glass of approved colour
and shade with reflective soft coating on surface # 2 of approved
colour and shade so as to match the colour and shade of the
IGUs in
the vision panels etc. ,all complete for the required performances
as
specified, as per the Architectural drawings, as per the approved
shop drawings, as specified, and as directed by the Engineer- in-
Charge.
For payment, only the actual area of glass on face # 1 of the glass
panels (but excluding the area of grooves and weather silicone
sealant)
3 provided and fixed in position, shall be measured in sqm.
(Payment
for fixing of Spandrel Glass Panels in the curtain glazing is
included
in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick
substrate with reflective soft coating on face # 2, having properties
as visible Light transmittance (VLT) of 25 to 35 %, Light reflection
internal 10 to 15%, light reflection external 10 to 20 %, shading
coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. .
The
properties of performance glass shall be decided by technical
sanctioning authority as per the site requirement.

Sqm 979.69 2127.95 2084729.21 1069.50 2127.95 2275840.40

Extra for openable side / top hung vision glass panels (IGUs)
including providing and supplying at site all accessories and
hardwares for the openable panels as specified and of the
approved make such as heavy duty stainless steel friction hinges,
min 4 -point cremone locking sets with stainless steel plates,
4 Sqm 131.62 3163.10 416324.06 131.62 3163.10 416324.06
handles, buffers etc. including necessary stainless steel screws/
fasteners, nuts, bolts, washers etc. all complete as per the
Architectural drawings, as per the approved shop drawings, as
specified and as directed by the Engineering- Charge.
Providing and fixing dry cladding upto 10 metre heights with
30mm thick
gang saw cut stone with (machine cut edges) of uniform colour
and
size upto 1mx1m, fixed to structural steel frame work and/ or with
the
5 help of cramps, pins etc. and sealing the joints with approved Sqm 471.55 2407.40 1135197.43 603.23 2407.40 1452203.87
weather
sealant as per Architectural drawing and direction of Engineer-in-
charge.
(The steel frame work, stainless steel cramps and pins etc. shall
be
paid for separately)
White sand stone - 30mm thick gang saw cut stone

Providing and fixing false ceiling at all heights with integral


densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595 mm of approved texture, design and patterns
having NRC (Noise Reduction coefficient) of 0.50 (minimum) as
per
IS 8225:1987, Light reflectance of 85% (minimum). Non
combustible
as per BS:476 (part-4), fire performance as per BS:476 (part 6
&7),
humidity resistance of 100%, thermal conductivity < 0.043 W/m K
as per ASTM 518:1991, in true horizontal level suspended on
interlocking
metal powder coated T-Grid of hot dipped galvanised iron
6 section of 0.40 mm thick on Silhouette profile,rotary stiched Sqm 13849.26 1952.70 27043441.02 14366.26 1952.70 28052986.92
double
webbed white with 6mm reveal profile (white/black),comprising of
main-T runners of size 15x42mm of length 3000 mm, cross - T of
size 15x42 mm of length 1200 mm and secondary intermediate
cross-
T of size 15x42 mm of length 600mm to form grid module of size
600 x 600 mm, suspended from ceiling using galvanised mild
steel
items (galvanizing @ 80 graing
coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. .
The
properties of performance glass shall be decided by technical
sanctioning authority as per the site requirement.to 200 mVhr (2)
Static Water Penetration Test. (50pa to 1500pa) as per ASTME-
With 15 mm thick integral densified micro edge light
weight calcium silicate false ceiling tiles

Providing and Fixing 15 mm thick densified tegular edged eco


friendly light weight calcium silicate false ceiling tiles of approved
texture of size 595 x 595 mm in true horizontal level, suspended
on inter locking metal grid of hot dipped galvanised steel sections
(galvanising @ 120 grams per sqm including both side) consisting
of main ‘T’ runner suitably spaced at joints to get required length
and of size 24x38 mm made from 0.33 mm thick (minimum) sheet,
spaced 1200 mm centre to centre, and cross “T” of size 24x28
mm made out of 0.33 mm (Minimum) sheet, 1200 mm long
spaced between main’T’ at 600 mm centre to centre to form a grid
of 1200x600 mm and secondary cross ‘T’ of length 600 mm and
size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be
inter locked at middle of the 1200x 600 mm panel to from grid of
size 600x600 mm, resting on periphery walls /partitions on a
Perimeter wall angle pre-coated steel of size(24x24X3000 mm
made of 0.40 mm thick (minimum) sheet with the help of rawl
plugs at 450 mm centre to centre with 25 mm long dry wall screws
@ 230 mm interval and laying 15 mm thick densified edges
calicum silicate ceiling tiles of approved texture in the grid,
including, cutting/ making opening for services like diffusers, grills,
light fittings, fixtures, smoke detectors etc., wherever required.
Main ‘T’ runners to be suspended from ceiling using G.I. slotted
cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and
50 mm long dash fasteners, 4 mm G.I. adjustable rods with
galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at
1200 mm centre to centre along main ‘T’, bottom exposed with 24
mm of all Tsections shall be pre-painted with polyster baked paint,
for all heights, as per specifications, drawings and as directed by
Engineer-in-Charge.
Note :- Only calcium silicate false ceiling area will be measured
from wall to wall. No deduction shall be made for exposed frames/
opening (cut outs) having area less than 0.30 sqm.The calcium
silicate ceiling tile shall have NRC value of 0.50 (Minimum), light
SQM. 548.37 1643.95 901492.86 613.87 1643.95 1009171.59
reflection > 85%, non- combustible as per B.S. 476 part IV, 100%
humidity resistance and also having thermal conductivity <0.043
w/ mK.

TOTAL 134573035.97 368715452.14 7705685.03 TOTAL 139069238.62 376174642.77 7795501.73 COST INCREASE IS
Less 14.05 % GST on DSR Item 323292812.05 329833093.18 DUE TO THE INCREASE
Less 1 % Labour Cess on DSR Item 320091893.12 326567418.99 IN AREA DUE TO
TOTAL 134573035.97 320091893.12 7705685.03 TOTAL 139069238.62 326567418.99 7795501.73 MERGER OF LIBRARY &
TOTAL COST OF CIVIL WORK 462370614.11 473432159.34 11061545.23 ADMIN BLOCK

B INTERNAL PLUMBING
1.0 Sanitary Fixtures & CP Brass Fittings
Providing and fixing vitreous china water closet squatting pan (Indian
1.1
type).

1.1.1 Orissa pattern W.C. pan size 580x440 mm Each 3 1820.00 5460.00 3 1820 5460

Providing and fixing P.V.C. low level flushing cistern with manually
1.2 controlled device (handle lever) conforming to IS 7231, with all fittings Each 3 1130.00 3390.00 3 1130 3390
and fixtures complete. 10 litre capacity – white

Providing and fixing vitreous china dual purpose closet suitable for use
as squatting pan or European type water closet (Anglo Indian W.C. pan)
with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre
low level flushing cistern with fitting and brackets, 40 mm flush bend, 20
1.3
mm over flow pipe, with specials of standard make and mosquito proof
coupling of approved municipal design complete, including painting of
fittings and brackets, cutting and making good the walls and floors
wherever required.

White vitreous china dual purpose W.C. pan with white solid plastic seat
1.3.1 and lid with white vitreous china flushing cistern and C.P. flush bend ISI Each 8500.00 0.00 0 8500 0
Mark Kajaria equivalent Indian made Brand.

Providing and fixing white vitreous china extended wall mounting water
closet of size 780x370x690 mm of approved shape including providing
& fixing white vitreous china cistern with dual flush fitting, of flushing
1.4 Each 246 10800.00 2656800.00 246 10800 2656800
capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat
cover, and cistern fittings, nuts, bolts and gasket etc
complete. ISI Mark Kajaria eqvilent Indian made Brand.

Providing and fixing 8 mm dia C.P./ S.S. Jet with flexible tube upto 1
1.5 metre long with S.S. triangular plate to European type W.C. of quality Each 515.00 0.00 515 0
and make as approved by Engineer–in-charge

Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass
pillar taps, 32 mm C.P. brass waste of standard pattern, including
1.6
painting of fittings and brackets, cutting and making good the walls
wherever require:

White Vitreous China Wash basin size 630x450 mm with a single 15


1.6.1 Each 183 2500.00 457500.00 183 2500 457500
mm C.P. brass pillar tap

Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass
single hole basin mixer of approved quality and make, including painting
1.7
of fittings and brackets, cutting and making good the walls wherever
required:-

White Vitreous China Wash basin size 550x400 mm with a 15 mm C.P.


1.7.1 Each 73 4403.80 321477.40 73 4403.8 321477.4
brass single hole basin mixer.

Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS 13983 with C.I. brackets and stainless steel plug 40 mm including
1.8
painting of fittings and brackets, cutting and making good the walls
wherever required :

1.8.1 Kitchen sink with drain board 510x1040 mm bowl depth 200 mm Each 29 3930.00 113970.00 29.00 3930.00 113970

Providing and fixing white vitreous china laboratory sink with C.I.
brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and
1.9 40mm C.P. brass trap with necessary C.P. brass unions complete,
including painting of fittings and brackets, cutting and making good the
wall wherever required :

1.9.1 Size 600x450x200 mm Each 10 5460.45 54604.50 10 5460.45 54604.5

Providing and fixing 600x450 mm beveled edge mirror of superior glass


1.10 (of approved quality) complete with 6 mm thick hard board ground fixed Each 256 975.00 249600.00 256 975 249600
to wooden cleats with C.P. brass screws and washers complete.

Providing and fixing P.V.C. Waste pipe for sink or wash basin
1.11
including P.V.C. waste fittings complete.

1.11.1 Semi rigid pipe, 40 mm dia. Each 29 105.00 3045.00 29 105 3045
Providing and fixing CP Brass 32mm size Bottle Trap of approved
1.12 Each 256 883.05 226060.80 256.00 883.05 226060.8
quality & make and as per the direction of Engineer-in-charge.

Providing and fixing CP Brass Single lever telephonic wall mixer of


1.13
quality & make as approved by Engineer in charge.

1.13.1 (a) 15 mm nominal dia Each 70 6113.60 427952.00 70 6113.6 427952

Providing and fixing toilet paper holder standrad size ISI marked C.P.
1.14 Each 246 220.00 54120.00 246 220 54120
brass as per direction Engineer-in-charge

Providing and fixing white vitreous china battery based infrared sensor
operated urinal of approx. size 610 x 390 x 370 mm having pre & post
1.15 flushing with water (250 ml & 500 ml consumption), having water inlet Each 72 6913.90 497800.80 72.00 6913.90 497800.8
from back side, including fixing to wall with suitable brackets all as per
manufacturers specification and direction of Engineer-in-charge.

Providing and fixing C.P. brass bib cock of approved


1.16
quality conforming to IS:8931.

1.16.1 15 mm nominal bore Each 249 525.00 130725.00 249 525 130725

Providing and fixing C.P. brass long nose bib cock of approved quality
1.17
confirming to ISI standards and weighing not less than 810 gms.

1.17.1 15 mm nominal bore Each 65 595.00 38675.00 65 595 38675

Providing and fixing C.P. brass angle valve for basin mixer and geyser
1.18
points of approved quality confirming to IS:8931

1.18.1 15 mm nominal bore Each 982 485.00 476270.00 982 485 476270

1.19 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :

1.19.1 150 mm diameter Each 70 188.80 13216.00 70 188.8 13216

Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of


1.20 Each 1444 61.25 88445.00 1444 61.25 88445
approved make and quality as per direction of Engineer-in-charge.

Providing and fixing uplasticised PVC connection pipe with brass unions
1.21 :

1.21.1 45 cm length, 15 mm nominal bore Each 982 83.00 81506.00 982 83 81506

Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm
high and 112 mm distance from wall of standard shape with bracket of
1.22 the same materials with snap fittings of approved quality and colour, Each 260 158.55 41223.00 260 158.55 41223
weighing not less than 105 gms.

Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement
1.23
of approved quality and colour.

600 mm long towel rail with total length of 645 mm, width 78 mm and
1.23.1 Each 82 595.50 48831.00 82 595.5 48831
effective height of 88 mm, weighing not less than 190 gms.

Providing and fixing PTMT soap Dish Holder having length of 138mm,
breadth 102mm, height of 75mm with concealed fitting arrangements,
1.24 Each 82 130.50 10701.00 82 130.5 10701
weighing not less than 106 gms.

Providing and fixing health faucet with 1 m long flexible tube and wall
1.25 hook including all fittings Jaguar Cat. No. ALD-IVC-593 or approved Each 246 919.00 226074.00 246.00 919.00 226074
equivalent.

Providing and fixing 15mm C.P brass Sink Mixer Jaguar Model. No.
FLR-5165 or approved equivalent.) for kitchen sink with swinging spout
1.26 Each 29 3130.00 90770.00 29.00 3130.00 90770
complete. Including cutting and making good the walls wherever
required .
Providing & fixing SS Grab Bar Euronics Model No. EGR (S02) & SS
1.27 Grab Rail Euronics Model No. EGR 01 or approved equivalent,Including Each 8 8337.00 66696.00 8.00 8337.00 66696
cutting and making good the walls wherever required.

Providing and fixing vertical storage type hot water heater fixed to wall
with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP
1.28 brass non-return valve complete including making connections with
15mm dia CP connecting pipes on inlet and outlet, suitable length of
power cable and 15 amps plug.

1.28.1 Capacity 25 Litres Venus Model Magma 25GV Each 27 9446.00 255042.00 27.00 9446.00 255042

Providing and fixing 150 litre/ hr. cooling and storage capacity,fully
stainless steel electric storage type water cooler (Blue Star model No.
1.29 SDLX 15150 or equvalant) with inlet hose connection inbuilt float valve. Each 16 57982.00 927712.00 16.00 57982.00 927712
2 Nos. outlet foucet, drain tray with waste and pipe up to fllor trap heavy
compressor and wire up to socket, 3 pin plug etc complete in all respect.

Supplying, installation, testing and commissioning of skid mounted fully


1.30 automatic Reverse Osmosis System of output capacity 50 litres / hour Each 16 108716.00 1739456.00 16.00 108716.00 1739456
designed at a minimum Flux at inlet complete as required.

1.31 Providing and Fixing of C.P. Brass Shower set comprising of :

One No. CP brass Single Lever Concealed Diverter Make Jaquar Cat.
No. FON-40079K + ALD-079.
One No. CP brass OH shower head Make Jaquar Cat. No. OHS-1989 &
Shower Arm Make Jaquar No.SHA-483.
One No. CP brass Bath Spout Make Jaquar Cat. No. SPJ-81429.
Including cutting and making good the walls wherever required.
Shower set as described above. Each 12 7508.00 90096.00 12.00 7508.00 90096
2.0 Soil, Waste, Vent & Rain Water Pipes

Providing and laying Cement Concrete with 2 cm gauge approved stone


grit, coarse sand & cement in the proportion of 4:2:1 including supply of
2.1 Cum 17 5280.00 89760.00 17.00 5280.00 89760
all materials, labour, Tools & plants etc. required for proper completion
of the work.

Making khurras 45x45 cm with average minimum thickness of 5 cm


cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron,
2.2 Each 154 244.05 37583.70 154.00 244.05 37583.7
finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a
coat of neat cement, rounding the edges and making and finishing the
outlet complete.

Providing and fixing on wall face unplasticised - PVC moulded


fittings/accessories for unplasticised Rigid PVC rain water pipes
2.3
conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS :5382, leaving 10 mm gap for thermal expansion.

2.3.1 75 mm diameter Metre 73 201.10 14680.30 73 201.1 14680.3


2.3.2 110 mm diameter Metre 914 305.05 278815.70 914 305.05 278815.7

Providing and fixing on wall face unplasticised - PVC moulded


fittings/accessories for unplasticised Rigid PVC rain water pipes
2.4
conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS :5382, leaving 10 mm gap for thermal expansion.

2.4.1 Coupler

2.4.1.1 75 mm Each 24 77.85 1868.40 24 77.85 1868.4


2.4.1.2 110 mm Each 102 117.80 12015.60 102 117.8 12015.6

2.4.2 Bend 87.5°

2.4.2.1 75 mm Bend Each 48 89.90 4315.20 48 89.9 4315.2


2.4.2.2 110 mm Bend Each 204 129.85 26489.40 204 129.85 26489.4

2.4.3 Shoe (Plain)

2.4.3.1 75 mm Shoe Each 24 79.20 1900.80 24 79.2 1900.8


2.4.3.2 110 mm Shoe Each 102 113.80 11607.60 102 113.8 11607.6

Providing and fixing to the inlet mouth of rain water pipe cast iron
2.5 Each 154 47.25 7276.50 154.00 47.25 7276.5
grating 15 cm diameter and weighing not less than 440 grams.

2.6 Providing and fixing soil, waste and vent pipes :

100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as
2.6.1 Metre 2729 825.00 2251425.00 2729.00 825.00 2251425
per IS: 3989

Providing and fixing bend of required degree with access door, insertion
2.7 rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S
as per IS - 3989.

2.7.1 100 mm dia.


2.7.1.1 Sand cast iron S&S as per IS - 3989 Each 37 461.65 17081.05 37.00 461.65 17081.05

2.8 Providing and fixing plain bend of required degree.

2.8.1 100 mm dia.


2.8.1.1 Sand cast iron S&S as per IS - 3989 Each 792 390.75 309474.00 792 390.75 309474

2.9 Providing and fixing heel rest sanitary bend

2.9.1 100 mm dia.


2.9.1.1 Sand cast iron S&S as per IS - 3989 Each 105 432.20 45381.00 105.00 432.20 45381

2.10 Providing and fixing double equal plain junction of required degree.

2.10.1 100x100x100x100 mm
2.10.1.1 Sand cast iron S&S as per IS - 3989 Each 34 865.70 29433.80 34.00 865.70 29433.8

Providing and fixing single equal plain junction of required degree with
2.11 access door, insertion rubber washer 3 mm thick, bolts and nuts
complete.
2.11.1 100x100x100 mm
2.11.1.1 Sand cast iron S&S as per IS - 3989 Each 129 722.55 93208.95 129.00 722.55 93208.95

2.12 Providing and fixing single equal plain junction of required degree.

2.12.1 100x100x100 mm
2.12.1.1 Sand cast iron S&S as per IS - 3989 Each 361 667.70 241039.70 361.00 667.70 241039.7

2.13 Providing and fixing terminal guard.

2.13.1 100 mm
2.13.1.1 Sand cast iron S&S as per IS - 3989 Each 105 389.40 40887.00 105.00 389.40 40887

2.14 Providing and fixing collar

2.14.1 100 mm
2.14.1.1 Sand cast iron S&S as per IS - 3989 Each 62 409.45 25385.90 62 409.45 25385.9

Providing lead caulked joints to sand cast iron/centrifugally cast (spun)


2.15
iron pipes and fittings of diameter :

2.15.1 100 mm Each 3545 481.45 1706740.25 3545.00 481.45 1706740.25

Providing and fixing MS Stay clamps for sand cast iron/ centrifugally
2.16
cast (spun) iron pipes of diameter.

2.16.1 100 mm dia Each 105 126.50 13282.50 105.00 126.50 13282.5

Providing and fixing trap of self cleansing design with screwed down or
2.17 hinged with or without vent arm complete, including cost of cutting and
making good the walls and floors.

2.17.1 100 mm inlet and 100 mm outlet


2.17.1.1 Sand cast iron S&S as per IS: 3989 Each 338 1512.55 511241.90 338.00 1512.55 511241.9

Painting sand cast iron/ centrifugally cast (spun) soil, waste, vent pipes
2.18 and fittings with paint of any colour such as chocolate grey, or buff etc.
over a coat of primer (of approved quality) for new work.

2.18.1 100 mm diameter pipe Metre 2729 64.20 175201.80 2729.00 64.20 175201.8

Providing and fixing G.I. pipes complete with G.I. fittings and clamps,
2.19
i/c cutting and making good the walls etc. (Internal work)

2.19.1 32 mm dia nominal bore Metre 385 529.70 203934.50 385.00 529.70 203934.5
2.19.2 40 mm dia nominal bore Metre 132 639.60 84427.20 132.00 639.60 84427.2
2.19.3 50 mm dia nominal bore Metre 251 786.75 197474.25 251.00 786.75 197474.25

Painting GI pipes and fittings with two coats of anti-corrosive bitumastic


2.20
paint of approved quality.

2.20.1 32 mm dia. nominal bore Metre 385 17.05 6564.25 385.00 17.05 6564.25
2.20.2 40 mm dia. nominal bore Metre 132 19.40 2560.80 132.00 19.40 2560.8
2.20.3 50 mm dia. nominal bore Metre 251 23.35 5860.85 251.00 23.35 5860.85

Providing and fixing M.S. holder-bat clamps of approved design to Sand


Cast iron/cast iron (spun) pipe embedded in and including cement
concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4
2.21
graded stone aggregate 20 mm nominal size), including cost of cutting
holes and making good the walls etc. :

2.21.1 For 100 mm dia pipe Each 835 287.45 240020.75 835.00 287.45 240020.75
2.21.2 For 75 mm dia pipe Each 29 283.40 8218.60 29.00 283.40 8218.6

Providing and fixing uPVC agricultural pipes conforming to IS:4985 (6


kg/sqcm) including all fittings, e.g. couplings, tees, bends, reducers and
2.22
screwed adoptors jointing with solvent cement joint as per
manufacturers' recommendations. [for Waste Pipes & Rain Water Pipes]

2.22.1 160 mm OD Metre 80 1008.00 80640.00 80.00 1008.00 80640


Providing and fixing of GI split pipe support clamps with EPDM rubber
lining, Zinc plated for support of vertical/hanging horizontal soil, waste,
vent and rain water pipes, embedded in walls with anchor fastner,
2.23
including recommended size GI threaded rod of required length etc.
including cost of cutting holes and making good the walls complete in all
respects.

2.23.1 For 150 mm dia Pipe (Thickness of clamp 2.0 mm) Each 32 319.00 10208.00 32.00 319.00 10208

Providing and fixing cast brass floor clean out plug with suitable insert
keys for opening, male threaded joint with GI threaded socket drip seal
2.24
to soil / waste pipe of CI pipe as required complete as per drawing
approved sample and direction of engineer in charge.

2.24.1 100 mm dia Each 88 1239.00 109032.00 88.00 1239.00 109032

Providing and fixing in position 110x63 mm dia uPVC reducing elbow


2.25 Each 164 131.00 21484.00 164.00 131.00 21484
including fix to floor with cement mortar.

Providing and fixing 100 mm dia GI inlet fitting/ Extension Piece with 2
2.26 or 3 inlets of 32 to 50 mmdia, fixed to CI trap with lead joint and set in Each 338 787.00 266006.00 338.00 787.00 266006
cement concrete as per drawing complete.

Providing and fixing in position 125x125 mm stainless steel grating for


2.27 Each 502 277.00 139054.00 502.00 277.00 139054
floor trap/floor drain including fix to floor with cement mortar.
3.0 Water Supply System

Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,


having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m
3.1 spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the same
including testing of joints complete as per direction of Engineer in
Charge.
Concealed work including cutting chases and making good the walls
etc.

3.1.1 15 mm nominal outer dia .Pipes. Metre 2030 260.00 527800.00 2030.00 260.00 527800
3.1.2 20 mm nominal outer dia .Pipes. Metre 985 300.00 295500.00 985.00 300.00 295500
3.1.3 25 mm nominal outer dia .Pipes. Metre 655 350.00 229250.00 655.00 350.00 229250
3.1.4 32 mm nominal outer dia .Pipes. Metre 310 440.00 136400.00 310.00 440.00 136400
3.1.5 40 mm nominal outer dia .Pipes. Metre 100 440.00 44000.00 100.00 440.00 44000

Providing and fixing G.I. pipes complete with G.I. fittings and clamps,
3.2
i/c cutting and making good the walls etc.
Internal work - Exposed on wall
3.2.1 15 mm dia nominal bore Metre 105 284.90 29914.50 105 284.9 29914.5
3.2.2 20 mm dia nominal bore Metre 665 344.10 228826.50 665 344.1 228826.5
3.2.3 25 mm dia nominal bore Metre 960 438.00 420480.00 960 438 420480
3.2.4 32 mm dia nominal bore Metre 830 529.70 439651.00 830 529.7 439651
3.2.5 40 mm dia nominal bore Metre 810 639.60 518076.00 810 639.6 518076
3.2.6 50 mm dia nominal bore Metre 595 786.75 468116.25 595 786.75 468116.25
3.2.7 65 mm dia nominal bore Metre 140 1076.00 150640.00 140 1076 150640
3.2.8 80 mm dia nominal bore Metre 35 1252.00 43820.00 35 1252 43820
0 0
Providing and fixing gun metal gate valve with C.I. wheel of approved
3.3 0 0
quality (screwed end) :
0 0
3.3.1 20 mm dia nominal bore Each 195 460.20 89739.00 195 460.2 89739
3.3.2 25 mm dia nominal bore Each 102 497.15 50709.30 102 497.15 50709.3
3.3.3 32 mm dia nominal bore Each 50 581.25 29062.50 50 581.25 29062.5
3.3.4 40 mm dia nominal bore Each 24 678.40 16281.60 24 678.4 16281.6
3.3.5 50 mm dia nominal bore Each 10 869.20 8692.00 10 869.2 8692
3.3.6 65 mm dia nominal bore Each 5 1488.10 7440.50 5 1488.1 7440.5
3.3.7 80 mm dia nominal bore Each 3 2217.90 6653.70 3 2217.9 6653.7

Painting G.I. pipes and fittings with synthetic enamel white paint with
3.4 two coats over a ready mixed priming coat, both of approved quality for
new work :

3.4.1 15 mm dia nominal bore Metre 105 15.20 1596.00 105.00 15.20 1596
3.4.2 20 mm dia nominal bore Metre 665 18.15 12069.75 665.00 18.15 12069.75
3.4.3 25 mm dia nominal bore Metre 959 23.70 22728.30 959.00 23.70 22728.3
3.4.4 32 mm dia nominal bore Metre 830 28.40 23572.00 830.00 28.40 23572
3.4.5 40 mm dia nominal bore Metre 810 33.40 27054.00 810.00 33.40 27054
3.4.6 50 mm dia nominal bore Metre 591 39.80 23521.80 591.00 39.80 23521.8
3.4.7 65 mm dia. nominal bore Metre 125.69 42.00 5278.98 125.69 42.00 5278.98
3.4.8 80 mm dia. nominal bore Metre 35 49.00 1715.00 35.00 49.00 1715

Providing and placing on terrace (at all floor levels) polyethylene water
storage tank lSI: 12701 marked(Sintex or equivalent) with cover and
3.5 suitable locking arrangement and making necessary holes for inlet, outlet Litre 79500 6.25 496875.00 79500 6.25 496875
and overflow pipes but without fittings and the base support for tank
complete as per direction of Engineer-in-charge.

Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a


elastomeric flexible material having hermetic blister closed cell structure
3.6 of expanded synthetic rubber over pipes of following nominal bores and
thickness including all required accessories complete as per
specification.

3.6.1 For 20 mm dia Pipe 6 mm thick (Concealed Pipes) Metre 610 54.00 32940.00 610.00 54.00 32940
3.6.2 For 25 mm dia Pipe 6 mm thick (Concealed Pipes) Metre 120 58.00 6960.00 120.00 58.00 6960
3.6.3 For 32 mm dia Pipe 9 mm thick (Concealed Pipes) Metre 80 89.00 7120.00 80.00 89.00 7120
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing, a
elastomeric flexible material having hermetic blister closed cell structure
of expanded synthetic rubber over pipes of following nominal bores and
3.7
thickness including protection by wrapping with 24 gauge alumminium
sheet with riveted screw joints all required accessories complete as per
specification.

13 mm thick (Exposed Pipes)

3.7.1 For 20 mm dia Pipe Metre 125 102.00 12750.00 125.00 102.00 12750
3.7.2 For 25 mm dia Pipe Metre 200 120.00 24000.00 200.00 120.00 24000
3.7.3 For 32 mm dia Pipe Metre 80 139.00 11120.00 80.00 139.00 11120

Providing and fixing forged brass single acting air release valve with
3.8 Each 22 726.00 15972.00 22.00 726.00 15972
screwed inlet 25 mm dia.

Providing and fixing of Single phase electrical actuator operated wafer


type rubber lined butterfly valve with by pass arrangement as per
drawing attached including level controller, 3 nos. normal butter fly
3.9
valves,necessary control and Power cables (Maximum 10 M. Length of
each type) and control panel installed on OH tank filling line near the
tanks complete in all respects.

3.9.1 25 mm dia. Each 8 25263.00 202104.00 8.00 25263.00 202104


3.9.2 32 mm dia. Each 8 25904.00 207232.00 8.00 25904.00 207232
3.9.3 40 mm dia. Each 4 26447.00 105788.00 4.00 26447.00 105788
3.9.4 50 mm dia. Each 2 26977.00 53954.00 2.00 26977.00 53954
4.0 Solar Water Heating System

Supply, Installation, Testing & Commissioning of Flat Plate collector


based on thermo syphon solar water heating System suitable for
Pressurized feed water comprising of 10 numbers of Flat Plate
4.1 collectors, internal system piping, insulated hot water storage tank with
heat exchanger, valves on inlet & outlet, Y strainer temperature gauge,
MS Angle frame etc. Details of each items used in system are mentioned
below

10 Nos. Solar Flat Plate collector having collector area should be min. 2
Sq, Mtr. (Collectror should be BIS & MNRE approved.

One No. Horizontal/Vertical hot water storage tank of 1000 ltr capacty
shall be made out by 4.0 mm thick stainless steel 316 grade,100 mm
thick rock wool/glass wool slab insulation (density of glass wool 64
Kg/Sqm.) covered with chicken mesh & 22 SWG aluminum sheet
cladding outside the tank. Tank shall be provided with flanges for inlet
outlet, over flow/ drain connection & Vent pipe with M H cover of 450
mm internal dia., Temperature and pressure release valve should be on
top of water storage tank

1 Lot of Inter-connected G.I. C-Class system piping size 25 mm dia with


fittings, insulated with 50 mm glasswool/rockwool insulation covered
with chicken mesh & 26SWG aluminum cladding to connect the
collectors with hot water storage tank.

Providing and fixing a lot of Temperature Gauge, vent pipe, ball valve,
NRV, CI/brass Y strainer, PT - 100 sensors with thermocople wire ,MS.
Angle stand for hot water tank .

One No. Heat Exchanger cage type inbuild the hot water storage tank of
SS 316 having surface area not less than 2.4 Sq. Mtr.
One No. Control Panel for electric heaters & recirculation pump having
DTC with contractor, MCBs, and cycling timer for pump.

Two Nos. Electric heater of 4.5 Kw each. With Thermostatic control.

4.1.1 Solar System as described above Set 5 333699.00 1668495.00 5.00 333699.00 1668495

Supply, installation, testing & commissining of package type solar water


heating system of capacity 300 ltrs each consisting of ISI Marked solar
flat plate type collectors 3 nos of size 2 x 1 mtr approx, laser or
ultrasonic welded of area 12 M2 with necessary MS stands, supports,
rubber EPDM gaskets with nut & bolts, rubber gasket for flanges,
Clamps etc. including with coiled type heat exchanger. Also included
500 ltrs capacity SS 316 pressurized hot water storage tank duly
4.2 Set 2 164283.00 328566.00 2.00 164283.00 328566
insulated with 100mm thick EPS / glass wool / rock wool insulation
covered with polythene, chicken mesh & 24 SWG aluminium cladding
with heat exchanger of suitable surface area with necessary make up
tank, necessary pipings between solar panels & solar hot water tank
including one no tempreature gauge, two nos ball valves. The system
shall be capable to produce hot water 55 to 60 deg on clear sunny days
and the efficiency of collectors should not be less than 72%.

Supply, installation, testing & commissioning of following pumps


suitable for 415 Volts connected with T.E.F.C. induction motor,
M.S.channel, base plate complete with vibration isolators, isolating
valve on suction and discharge, non return valve on discharge,
pressure gauges with stop cock and dial type thermometer on suction
4.3
or discharge. The pump shall have mechanical seal. The pump shall
be SS casing, impeller, shaft and CI (Epoxy coated) base & EPDM
Mechanical seal (suitable for hot water temperature up to 85 deg C.)
including Valves, NRV, Strainers, Pressure Gauge, Thermometer &
Cabling etc. complete in all respects.

4.3.1 Hot Water Return Pumps


Pump (2 Nos. 1W+1SB)
Flow - 1.0 LPS
Head - 15 mtrs Set 3 61606.00 184818.00 3.00 61606.00 184818

Total C/F to Summary 8260565.00 8784434.45 6891082.98 8260565 8784434.45 6891082.98


LESS GST 7702266.068 7702266.068
LESS CESS 7626006.007 7626006.007
TOTAL AMOUNT OF INTERNAL PLUMBING (B) 22777653.99 22777653.99 0.00

C INTERNAL ELECTRIFICATION
A PART (A) - SCHEDULED ITEMS ( AS PER UP SOR 2018)

1 Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrand
single core Copper Conductor cable in thick PVC conduit pipe
partly concealed in wall & partly laid in slab along with the
reinforcement before concreting complete with 1.5 Sq.mm copper earth
continuity wire & modular type switch & ceiling rose / angle / batten NOS 2686.00 654.00 1756644.00 2686.00 654.00 1756644
holder on 3 mm thick phenolic laminated backelite sheet etc complete in
all respects as directed, including matching color wash.

2 Wiring point for two way light with 1.5 sq.mm FR P.V.C. insulated
multistrand single core Copper Conductor cable in thick PVC
conduit pipe partly concealed in wall & partly laid in slab along with
the reinforcement before concreting complete with 1.5 Sq.mm copper
earth continuity wire and two no two way modular type switchws & NOS 52.00 956.00 49712.00 52.00 956.00 49712
ceiling rose / angle / batten holder on 3 mm thick phenolic laminated
backelite sheet etc complete in all respects as directed, including
matching color wash

3 Wiring point for fan/fresh air fan (light duty exhaust/ Ceiling fan)
with 1.5 sq.mm FR P.V.C. insulated multistrand single core Copper
Conductor cable in thick PVC conduit pipe partly concealed in wall
& partly laid in slab along with the reinforcement before concreting
complete with 1.5 Sq.mm copper earth continuity wire & modular type
switch & ceiling rose / angle / batten holder on 3 mm thick phenolic NOS 1167.00 715.00 834405.00 1167 715 834405
laminated backelite sheet etc complete in all respects as directed,
including matching color wash.

4 Wiring point for plug with 1.5 sq.mm FR P.V.C. insulated multistrand
single core Copper Conductor cable in thick PVC conduit pipe partly
concealed in wall & partly laid in slab along with the reinforcement
before concreting complete with 1.5 Sq.mm copper earth continuity wire
& modular type switch & socket etc complete in all respects including NOS 1383.00 410.00 567030.00 1383.00 410.00 567030
matching color wash.

5 Wiring point for call bell with 1.5 sq.mm FR P.V.C. insulated
multistrand single core Copper Conductor cable in thick PVC conduit
pipe partly concealed in wall & partly laid in slab along with the
reinforcement before concreting complete with 1.5 Sq.mm copper earth
NOS 30.00 652.00 19560.00 30.00 652.00 19560
continuity wire & modular type bell push or 2 pin socket etc complete
in all respects including matching color wash

6 Supply and fixing of power plug with 15A/250 volt flush type switch and
5 pin 15A/250V flush type universal socket in suitable M.S. box of
175mm x 100mm x 50mm size with phenolic laminated bakelite sheet
cover 3mm thick fixed with brass machine screw and cup washer. NOS 776.00 340.00 263840.00 776.00 340.00 263840

7 Supply and fixing of power plug with 20 Amp./250 volt flush type
modular switch and 5 pin 20 A/250 volt flush type universal modular
socket switch on concealed M.S box including supply of all material,
labour T&P etc. required for proper completion of work. NOS 238.00 625.00 148750.00 238.00 625.00 148750

8 Supply and fixing of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve


NOS 2640.00 260.00 686400.00 2640.00 260.00 686400
(CAT-A)
9 Supply & wiring of sub main with FRLSH P.V.C. insulated 1100
volts grade single core copper conductor cable in heavy gauge
thick PVC coduit partly concealed in wall and partly laid in slab along
with the reinforcement before concreting complete with one no. 14
SWG copper earth continuity wire complete in all respects.

a 2 x 1.5 sq. mm. with 1.5 sq.mm earth wire In 20 mm dia conduit. M 4270.00 121.00 516670.00 4270.00 121.00 516670
b 2 x 2.5 sq. mm. with 1.5 sq.mm earth wire In 20 mm dia conduit. M 46300.00 149.00 6898700.00 46300.00 149.00 6898700
c 2 x 4 sq. mm. with 2.5 sq. mm earth wire In 25mm dia conduit. M 27955.00 204.00 5702820.00 27955.00 204.00 5702820
d 2 x 6 sq. mm. with 4 sq. mm earth wire In 32mm dia conduit. M 7405.00 272.00 2014160.00 7405.00 272.00 2014160
e 2 x 10 sq. mm. with 6 sq. mm earth wire In 32mm dia conduit. M 1450.00 395.00 572750.00 1450.00 395.00 572750
f 2 x 16 sq. mm.with 10 sq. mm earth wire In32mm dia conduit. M 1675.00 463.00 775525.00 1675.00 463.00 775525
g 4 x 6 sq. mm. with 2 x 4 sq. mm earth wire In 32mm dia conduit. M 1050.00 360.00 378000.00 1050.00 360.00 378000
h 4 x 10 sq. mm.with 2 x 6 sq. mm earth wire In 32mm dia conduit. M 3900.00 505.00 1969500.00 3900.00 505.00 1969500
i 4 x 16 sq. mm. with 2 x 10 sq. mm earth wire In 32mm dia conduit.
M 3150.00 723.00 2277450.00 3150.00 723.00 2277450
10 Supply fixing and concealing 2mm thick PVC conduit pipe with ISI
mark embossed and with PVC accessories confirming to IS no 3419 for
drawing wires duly sealed at joints with original resin/ adhesive to make
the complete piping rigid, plastering with cement sand mortar finised to
the level with matching colour wash including cost of all material labour
and T&P etc required for proper completion of work. (for Telephone /
Television / circuits)

20 mm dia. conduit (16 SWG) thick M 6440.00 62.00 399280.00 6440.00 62.00 399280
25 mm dia. conduit (16 SWG) thick M 2715.00 72.00 195480.00 2715.00 72.00 195480
32 mm dia. conduit (16 SWG) thick M 1175.00 87.00 102225.00 1175.00 87.00 102225
11 S/F of surface/flush mounting SPN distribution board with additional
metal door without MCB complete in all respect as directed at site by
Engineer-in-charge..

8 WAYS ( CAT A ) NOS 12.00 1900.00 22800.00 12 1900 22800


12 WAYS ( CAT A ) NOS 10.00 2250.00 22500.00 10.00 2250.00 22500
12 S/F of surface/flush mounting TPN distribution board with additional
metal door without MCB complete in all respect as directed at site by
Engineer-in-charge..

6 WAYS ( CAT A ) NOS 12.00 4370.00 52440.00 12.00 4370.00 52440


8 WAYS ( CAT A ) NOS 10.00 5210.00 52100.00 10 5210 52100
12 WAYS ( CAT A ) NOS 58.00 7740.00 448920.00 58.00 7740.00 448920
13 S/F of 40 Amp DP MCB (10 KA) ( CAT A ) NOS 34.00 1180.00 40120.00 34.00 1180.00 40120
14 S/F of 63 Amp TP MCB (10 KA) )( CAT A ) NOS 150.00 1790.00 268500.00 150.00 1790.00 268500
S/F of surface/flush mounting 6 ways V TPN distribution board with
15 additional metal door without DPX3 160 mccb complete in all respect each 2.00 11980.00 23960.00 2.00 11980.00 23960
as directed at site by Engineer-in-charge. (Cat A)
S/F of surface/flush mounting 8 ways V TPN distribution board with
16 additional metal door without DPX3 160 mccb complete in all respect each 4.00 13130.00 52520.00 4.00 13130.00 52520
as directed at site by Engineer-in-charge. (Cat A)
S/F of surface/flush mounting 12 ways V TPN distribution board with
additional metal door without DPX3 160 mccb complete in all respect
17 each 4.00 17400.00 69600.00 4.00 17400.00 69600
as directed at site by Engineer-in-charge. (Cat A)

S&F of 160 Amp 4 Pole MCCB (25KA) thermal magnetic release (Cat
18 each 13.00 12660.00 164580.00 13.00 12660.00 164580
A)
Eraction and testing of ceiling fan and regulator for room height upto 3.5
19 meters including including supply of 3mm thick GI pipe 19mm dia, Duly each 905.00 140.00 126700.00 905.00 140.00 126700
painted, completed in all respect.
Add extra to item (1116) for 15cm or part there of for room height from
20 each 0.00 40.00 0.00 0.00 40.00 0
3.5 to 5.00 meter.
21 Erection and testing of exhaust/ wall fan on the existing hole with
suitable size of rag bolts nuts and washers etc complete in all respects.
NOS 237.00 195.00 46215.00 237.00 195.00 46215

22 S/F of hexagonal fan box with hexagonal/ round GP Fan box of


approved make made up of 1.0 mm thick ISI marled GP sheet spot
welded four to eight holes of 25.4 mm for pip[e entry of the box. Holes
should be semi shuttered tyupe with 0.5 mm GP sheet made upper &
lower cover duly screwed fitted with 300mm round zink coated MS bar
X 12mm & brand name should be embossed.Fixing with wiring conduit NOS 905.00 150.00 135750.00 905.00 150.00 135750
laid in the R.C.C. roof before concreting along with supply of all
materials, labour, T&P etc. for proper completion of work.

23 Supply & fixing of electronic Fan regulator, dimmer, 120-280 V ISI


marked, on the existing switch board including making connections,
required material, labour T/P etc. for proper completion of work to NOS 911.00 267.00 243237.00 911.00 267.00 243237
the satisfaction of Engineer of work.

24 S/F of door chime on Polished M.D.F.E.G. board including making


connections etc. complete in all respects. NOS 37.00 200.00 7400.00 37 200 7400

25 S/F of danger board fabricated from 10 gauge M.S. sheet as per E/I
NOS 12.00 85.00 1020.00 12 85 1020
rules.
26 S/F of shock treatment chart ( prescribed under I.E.rules ) duly
framed with glass and supported from back with hard board or soft
board with supply of all material labour T & P etc for proper completion NOS 12.00 305.00 3660.00 12.00 305.00 3660
of work.

27 Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered


rubber matting of tested quality. NOS 5.00 2550.00 12750.00 5 2550 12750

Supply and laying of aluminium conductor PVC insulated amoured


served sheathed cables 1100 Volts grade at depth of 750mm below
ground level over a cushion of 75mm. Thick sand all around and
protected with burnt bricks on sides and on top. On surface the cable run
28 shall be fixed on M.S. clamps etc. of suitable respect. The armouring of
the cable shall be properly connected with the earth conductor by clamps.
etc.

a 6 sq.mm 3 core Mtr. 600.00 284.00 170400.00 600.00 284.00 170400


b 10 sq.mm 4 core Mtr. 0.00 327.00 0.00 0.00 327.00 0
c 16 sq.mm 4 core Mtr. 500.00 343.00 171500.00 500.00 343.00 171500
d 25 sq.mm 3.5 core Mtr. 0.00 373.00 0.00 0.00 373.00 0
e 35 sq.mm 3.5 core Mtr. 800.00 422.00 337600.00 800.00 422.00 337600
f 50 sq.mm 3.5 core Mtr. 1245.00 492.00 612540.00 1245.00 492.00 612540
g 70 sq.mm 3.5 core Mtr. 400.00 613.00 245200.00 400.00 613.00 245200
h 95 sq.mm 3.5 core Mtr. 200.00 700.00 140000.00 200.00 700.00 140000
i 120 sq.mm 3.5 core Mtr. 300.00 824.00 247200.00 300.00 824.00 247200
j 150 sq.mm 3.5 core Mtr. 0.00 957.00 0.00 0.00 957.00 0
k 185 sq.mm 3.5 core Mtr. 700.00 1140.00 798000.00 700.00 1140.00 798000
l 240 sq.mm 3.5 core Mtr. 200.00 1379.00 275800.00 200.00 1379.00 275800
m 300 sq.mm 3.5 core Mtr. 900.00 1613.00 1451700.00 900.00 1613.00 1451700
0.00 0
Supply and fixing of brass nickle plated compression gland for PVC
insulated & armoured served sheathed, underground cable including
29 rubber ring etc. complete in all respect. The armouring of the cable shall
be properly connected with the earth as per direction of Engineer-
Incharge.
a 6 sq.mm 3 core Each 36.00 76.00 2736.00 36.00 76.00 2736
b 10 sq.mm 4 core Each 0.00 87.00 0.00 0.00 87.00 0
c 16 sq.mm 4 core Each 6.00 87.00 522.00 6.00 87.00 522
d 25 sq.mm 3.5 core Each 0.00 123.00 0.00 0.00 123.00 0
e 35 sq.mm 3.5 core Each 8.00 178.00 1424.00 8.00 178.00 1424
f 50 sq.mm 3.5 core Each 26.00 178.00 4628.00 26.00 178.00 4628
g 70 sq.mm 3.5 core Each 12.00 199.00 2388.00 12.00 199.00 2388
h 95 sq.mm 3.5 core Each 4.00 222.00 888.00 4.00 222.00 888
i 120 sq.mm 3.5 core Each 2.00 243.00 486.00 2.00 243.00 486
j 150 sq.mm 3.5 core Each 0.00 305.00 0.00 0.00 305.00 0
k 185 sq.mm 3.5 core Each 12.00 397.00 4764.00 12.00 397.00 4764
l 240 sq.mm 3.5 core Each 0.00 473.00 0.00 0.00 473.00 0
m 300 sq.mm 3.5 core Each 10.00 505.00 5050.00 10.00 505.00 5050

30 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip


Galvanized), Length upto 2000mm, outer pipe 50mm, inner pipe 25,
terminal dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12
SWG with Hot Dip Galvanization upto 100 micron filled with crystalline
conductive mixture (CCM) having anti corrosive & conductive property
with 50 kgs activated soil (BFC) capable of reducting the soil resistivity
with good mixture of retaining capacity along with 30cm square C.I. Each 80.00 6450.00 516000.00 80 6450 516000
frame with hinged cover & masonry husing (from electrode terminal to
switch board, cost of 25 x 3 G.I. strip with be extra)
Make: As approved in U.P.P.W.D., & C.P.R.I Certified.

31 Supply and fixing of horizontal air termination (roof conductor) of 25mm


x 3mm G.I. strip, G.I. clamps on surface complete in all respects as Metre 2070.00 170.00 351900.00 2070 170 351900
approved by Engineer-in-charge.
32 Supply and fixing of vertical air termination final rod comperising of
300mm long x 25 mm dia. Coper rod with one one pointed prong and Each 48.00 1330.00 63840.00 48 1330 63840
100mm dia x 3 mm thick base plate etc complete in all respect.
33 Supply and fixing of vertical down conductor of 32mm x 6mm G.I. strip
etc on approved clamps on surface for lighting conductor complete in all Metre 0.00 310.00 0.00 0.00 310.00 0
respect ( for two storyed buildings)
34 As in item 713(A) but for three or four storyed buildings Metre 1680.00 355.00 596400.00 1680.00 355.00 596400
35 As in item 713(A) but for five and above storyed buildings Metre 0.00 390.00 0.00 0.00 390.00 0
36 Supplying & Laying of 25mm x 3mm. G.I. strip for earthing purpose as
required complete in all respects. M 2460.00 90.00 221400.00 2460.00 90.00 221400
37 Supply and fixing of one number 8 SWG G.I. wire in 15mm dia G.I. pipe
for earthing, laid in ground or in wall duty concealed including the cost
of cement, sand, labour, T&P other material required for proper M 2230.00 200.00 446000.00 2230.00 200.00 446000
completion of the work as directed at site.

38 S&F of 63 Amp. four pole change over switch on 40mm x 40mm x 6mm
angle iron frame, including the cost of labour, T&P, painting and other
NOS 3.00 4760.00 14280.00 3.00 4760.00 14280
material required for proper completion of the work as per direction and
satisfaction of Engineer in charge.
39 Supply and fixing of recess/surface/ Pendent mounting round 6 Watt to 8
Watt LED Down Lighter having Powder coated die cast aluminium
Each 227.00 770.00 174790.00 227.00 770.00 174790
housing with extended heat sink, diffuser/ Reflector and driver set
completed in all respects. ( CAT - AAA )
40 Supply and fixing of recess/surface/ Pendent mounting round 10 Watt to
15 Watt LED Down Lighter having Powder coated die cast aluminium
Each 1185.00 1350.00 1599750.00 1185.00 1350.00 1599750
housing with extended heat sink, diffuser/ Reflector and driver set
completed in all respects. ( CAT - AAA )
41 Supply and fixing of LED tube light with batten suitable for uo to 1 x 22
watt LED tube light fitting including tube on surface completein all Each 1386.00 1190.00 1649340.00 1386.00 1190.00 1649340
respect. (CAT - AAA)
42 Supply and fixing of single LED light wall bracket 3 to 6 watt on
matching M.D.F.E.G Board base etc. completed in all respects. ( CAT - Each 378.00 2600.00 982800.00 378.00 2600.00 982800
AAA )
43 Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire
with driver set confirming to IP 65 as above Protection . complete in all Each 72.00 1400.00 100800.00 72.00 1400.00 100800
respect.( CAT AAA )
44 Supply and fixing of factory wired integral LED flood light luminaires
with die cast aluminium housing built with dirver set suitable for 140 to
Each 34.00 13190.00 448460.00 34.00 13190.00 448460
150 Watt. Confirming to IP 66 protection complete in all respect.

PART (B) - SCHEDULED ITEMS ( AS PER DSR 2018)


1 Wiring for group controled (looped) light point/fan point/exhaust fan
point/call bell point with 1.5 Sq.Mm FRLC PVC insulated copper
conductor single core cable in surface / recessed medium class PVC
conduit, with modular switch, modular plate,suitable GI box and earthing
the point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single
core cable etc. as required.
1.1 Group A Point 0.00 463.00 0.00 463.00
1.2 Group B Point 208.00 508.00 105664.00 208.00 508.00 105664
1.3 Group C Point 302.00 555.00 167610.00 302.00 555.00 167610
2 Supplying and fixing following size / modules, GI box along with
modular base & cover plate for modular switches in recess etc. as
required
2.1 1 or 2 Module (75mmX75mm) Each 296.00 243.00 71928.00 296.00 243.00 71928
3 Supplying and fixing following modular switch / socket on the existing
modular plate & switch box including connections but excluding 0.00 0
modular plate etc as required
3.1 Telephone Socket outlet Each 197.00 119.00 23443.00 197.00 119.00 23443
3.2 TV Antenna socket outlet Each 99.00 119.00 11781.00 99.00 119.00 11781
4 Supply and drawing following pair, 0.5 sq.mm. FR PVC insulated
annealed copper conductor, unarmoured telephone cable in the existing 0.00 0
surface / recessed steel/ PVC conduit as required
4.1 1 Pair M 4890.00 19.00 92910.00 4890.00 19.00 92910
5 Supply and drawing co-axial TV cable RG-6 grade, 0.7 mm. Solid
copper conductor PE insulated, shielded with fine tinned copper braid
M 2185.00 33.00 72105.00 2185.00 33.00 72105
and protected with PVC sheath in the existing surface / recessed steel/
PVC conduit as required.
6 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing
0.00 0
surface/ recessed steel/ PVC conduit as required
6.1 1 Run of Cable Mtr 4100.00 49 200900.00 4100.00 49.00 200900
7 Extra for fixing the louvers / shutters complete with frame fro exhaust
each 219.00 168.00 219.00 168.00
fans of all sizes.
8 Providing, laying and fixing following dia RCC pipe NP2 class (light
duty) in ground complete with RCC collars, jointing with cement mortar
0.00 0.00 0.00 0
1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and
refilling etc as required..
8.1 150 mm dia Mtr 130.00 598.00 77740.00 130.00 598.00 77740
8.2 250 mm dia Mtr 630.00 701.00 441630.00 630.00 701.00 441630
9 Supplying and Fixing suitable size GI box with modular plate and cover
in front on surface or in recess or in recess including providing and
each 25.00 639.00 15975.00 25.00 639.00 15975
fixing 25A modular socket outlet and 25A modular SP MCB 'C' curve
including connections, painting etc as required.

PART-C MARKET RATE ITEMS


1 Providing, fixing, connecting & testing of Telephone Tag Block krone
type in a suitable size 1.6 mm thick dust and vermin proof Sheet steel
enclosure duly painted by synthetic enamel over anti corrosive primer,
lockable and hinged cover with provision for cable through glands
complete in all respects.
a 5 pair Tag Block Nos 102.00 163.00 16626 102 163 16626
b 10 pair Tag Block Nos 8.00 182.00 1456 8 182 1456
c 20 pair Tag Block Nos 10.00 194.00 1940 10 194 1940
d 50 pair Tag Block Nos 1.00 275.00 275 1 275 275
e 100 pair Tag Block Nos 1.00 438.00 438 1 438 438
2 Supplying, laying, testing and commissioning of following size anealed
tinned copper conductor PVC insulated and sheathed armoured copper
telephone cables 0.5mm with suitable clamps, saddles and including
making terminal joints complete as required

a 5 pair M 72.00 40.00 2880 72 40 2880


b 10 pair M 370.00 56.00 20720 370 56 20720
c 20 pair M 930.00 150.00 139500 930 150 139500
d 50 pair M 100.00 382.00 38200 100 382 38200
e 100 pair M 100.00 750.00 75000 100 750 75000

3 Supply of AC 230/250 volts, 50 HZ ceiling fan with standard down


rod, blades, 2 nos. caps & regulator etc. ISI marked complete as required.

1200 mm sweep, 50W, 350 RPM Nos 900.00 2107.00 1896300 900 2107 1896300
4 Supply of AC 230/250 volts, 50 HZ exhaust fan including providing
nuts, bolts, mounting frame and other accessories etc. complete

250 mm sweep 1250 rpm Nos 223.00 2348.00 523604 223 2348 523604
5 Supply of AC 230/250 volts, 50 HZ Wall fan including providing nuts,
bolts, mounting frame and other accessories etc. complete
400 mm sweep 1350 rpm Nos 41.00 2348.00 96268 41 2348 96268

6 MAIN BUIDLING PANEL


Supply, installation, testing & commissioning of front operated front
access cuibical type indoor duly floor / wall / recess / surface mounting,
totally enclosed dust and vermin proof (minimum protection IP 54)
panels with neoprene gaskets, fabricated from 2mm thick CRCA sheets
with powder coated finish (minimum thickness 50 micron)suitable for
415 volts 3 phase 4 wire 50 Hz system to withstand syummetrical fault
level of 35 kA at 415V, 3 phase, 4 wire, 50 Hz system including
interconnections, bonding to earth etc. and flush door conforming to
relevant IS standard including complete as per specification & drawings
as required and as given below. All internal wiring in the panels shall be
carried out using FRPVC swires capable of withstanding high
temperature. panel shall be approved by architect.

Incoming
400A FP 35kA MCCB with thermal magnetic release with adjustable
OL, SC and EF protection - 1 nos.
1- set Red/Green ON/OFF indicating lamps
1- set of three phase (red, yellow, blue) indicating lamps
Amber healthy trip indicating lamps
1 nos MFM
Bus Bars
Electrolytic high conductivity Aluminium three phase and neutral
busbars rated at 600 A having a maximum current density of 1.0 A per
sq mm suitable to with stand symmetrical fault level of 35kA at 415 V.

Outgoings
160 A, 4P 35 KA MCCB -- 1 no
100 A, 4P 35 KA MCCB -- 4 no
63 A, 4P 35 KA MCCB -- 2 no
The switchboard shall be complete with all inter connections, risers,
each 3.00 350000.00 1050000 3 350000 1050000
internal wiring, labels etc complete as required

Supply, fixing, testing and commissioning & automatic Linear


pneumatic Tube Detection based Novec 1230 System for Electrical
Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),
consisting of the following components
5 LB capacity Novec 1230, DLP Assembly witth automatic valve, push
in connector for tube, 5 LB Novec 1230 gas mounting bracket, End of
No. 4.00 129569.00 518276 4 129569 518276
Line adopter and low pressure switch for monitoring system activation.(
Utility Panel, UPS Panel)
10 LB capacity Novec 1230, DLP Assembly witth automatic valve, push
in connector for tube, 10 LB Novec 1230 gas mounting bracket, End of
Line adopter and low pressure switch for monitoring system activation. No. 5.00 207248.00 1036240 5 207248 1036240
(2 nos VCB panel, 2 nos LT Panel, 1 nos DG Panel etc)

Linear pneumatic heat Detection Tube with all necessary fittings &
Meter 135.00 2056.00 277560 135 2056 277560
supports.
Master Control Unit for controllin each system, complete with pressure
switches, buzzers and electronic hooters, including all necessary
No. 9.00 5277.00 47493 9 5277 47493
acessories +electrical writing to make each entire system functional.

7 FLOOR PANEL
Supply, installation, testing & commissioning of front operated front
access cuibical type indoor duly floor / wall / recess / surface mounting,
totally enclosed dust and vermin proof (minimum protection IP 54)
panels with neoprene gaskets, fabricated from 2mm thick CRCA sheets
with powder coated finish (minimum thickness 50 micron)suitable for
415 volts 3 phase 4 wire 50 Hz system to withstand syummetrical fault
level of 35 kA at 415V, 3 phase, 4 wire, 50 Hz system including 0 0
interconnections, bonding to earth etc. and flush door conforming to
relevant IS standard including complete as per specification & drawings
as required and as given below. All internal wiring in the panels shall be
carried out using FRPVC swires capable of withstanding high
temperature. panel shall be approved by architect.

Incoming 0 0
100A FP 25kA MCCB with thermal magnetic release with adjustable
0 0
OL, SC and EF protection - 1 nos.
1- set Red/Green ON/OFF indicating lamps
1- set of three phase (red, yellow, blue) indicating lamps
Amber healthy trip indicating lamps
1 nos MFM
Bus Bars
Electrolytic high conductivity Aluminium three phase and neutral
busbars rated at 200 A having a maximum current density of 1.0 A per
sq mm suitable to with stand symmetrical fault level of 25kA at 415 V.

Outgoings
63 A, 4P 35 KA MCB -- 5 no
40 A, 4P 10 KA MCB -- 2 no
The switchboard shall be complete with all inter connections, risers,
each 5.00 195000.00 975000 5 195000 975000
internal wiring, labels etc complete as required

7A Supply, installation, testing & commissioning of front operated front


access cuibical type indoor duly floor / wall / recess / surface mounting,
totally enclosed dust and vermin proof (minimum protection IP 54)
panels with neoprene gaskets, fabricated from 2mm thick CRCA sheets
with powder coated finish (minimum thickness 50 micron)suitable for
415 volts 3 phase 4 wire 50 Hz system to withstand syummetrical fault
level of 35 kA at 415V, 3 phase, 4 wire, 50 Hz system including
interconnections, bonding to earth etc. and flush door conforming to
relevant IS standard including complete as per specification & drawings
as required and as given below. All internal wiring in the panels shall be
carried out using FRPVC swires capable of withstanding high
temperature. panel shall be approved by architect.

Incoming
100A FP 25kA MCCB with thermal magnetic release with adjustable
OL, SC and EF protection - 1 nos.
1- set Red/Green ON/OFF indicating lamps
1- set of three phase (red, yellow, blue) indicating lamps
Amber healthy trip indicating lamps
1 nos MFM
Bus Bars
Electrolytic high conductivity Aluminium three phase and neutral
busbars rated at 200 A having a maximum current density of 1.0 A per
sq mm suitable to with stand symmetrical fault level of 25kA at 415 V.

Outgoings
63 A, 4P 35 KA MCB -- 5 no
40 A, 4P 10 KA MCB -- 2 no
The switchboard shall be complete with all inter connections, risers,
each 4.00 155000.00 620000 4 155000 620000
internal wiring, labels etc complete as required

7B DG PANEL
Supply, installation, testing & commissioning of front operated front
access cuibical type indoor duly floor / wall / recess / surface mounting,
totally enclosed dust and vermin proof (minimum protection IP 54)
panels with neoprene gaskets, fabricated from 2mm thick CRCA sheets
with powder coated finish (minimum thickness 50 micron)suitable for
415 volts 3 phase 4 wire 50 Hz system to withstand syummetrical fault
level of 35 kA at 415V, 3 phase, 4 wire, 50 Hz system including
interconnections, bonding to earth etc. and flush door conforming to
relevant IS standard including complete as per specification & drawings
as required and as given below. All internal wiring in the panels shall be
carried out using FRPVC swires capable of withstanding high
temperature. panel shall be approved by architect.

Incoming
100A FP 25kA MCCB with thermal magnetic release with adjustable
OL, SC and EF protection - 1 nos.
1- set Red/Green ON/OFF indicating lamps
1- set of three phase (red, yellow, blue) indicating lamps
Amber healthy trip indicating lamps
1 nos MFM
Bus Bars
Electrolytic high conductivity Aluminium three phase and neutral
busbars rated at 200 A having a maximum current density of 1.0 A per
sq mm suitable to with stand symmetrical fault level of 25kA at 415 V.

Outgoings
63 A, 4P 10 KA MCB -- 5 no
40A, DP 10 KA MCB -- 2 no
The switchboard shall be complete with all inter connections, risers,
each 1.00 125000.00 125000 1 125000 125000
internal wiring, labels etc complete as required

8 UPS PANEL
Supply, installation, testing & commissioning of front operated front
access cuibical type indoor duly floor / wall / recess / surface mounting,
totally enclosed dust and vermin proof (minimum protection IP 54)
panels with neoprene gaskets, fabricated from 2mm thick CRCA sheets
with powder coated finish (minimum thickness 50 micron)suitable for
415 volts 3 phase 4 wire 50 Hz system to withstand syummetrical fault
level of 35 kA at 415V, 3 phase, 4 wire, 50 Hz system including 0 0
interconnections, bonding to earth etc. and flush door conforming to
relevant IS standard including complete as per specification & drawings
as required and as given below. All internal wiring in the panels shall be
carried out using FRPVC swires capable of withstanding high
temperature. panel shall be approved by architect.

Incoming 0 0
63A FP 25kA MCCB with thermal magnetic release with adjustable OL,
0 0
SC and EF protection - 1 nos.
1- set Red/Green ON/OFF indicating lamps 0 0
1- set of three phase (red, yellow, blue) indicating lamps 0 0
Amber healthy trip indicating lamps 0 0
1 nos MFM 0 0
Bus Bars
Electrolytic high conductivity Aluminium three phase and neutral
busbars rated at 100 A having a maximum current density of 1.0 A per
sq mm suitable to with stand symmetrical fault level of 25kA at 415 V.

Outgoings
40 A, 4P 10 KA MCB -- 4 no
40 A, SP 10 KA MCB -- 2 no
The switchboard shall be complete with all inter connections, risers,
each 6.00 120000.00 720000 6 120000 720000
internal wiring, labels etc complete as required

EXTRA ITEMS

UPS
1 Supply, installation, testing and commissioning and testing of 20KVA
N+1, 415V, 3ph input & 3 ph output ON-LINE UPS system back up
protection for 30 minutes as per EN/ IEC standared with all accessories
as required.
Details of UPS :-
(IGBT based rectifier & inverter) True Online UPS Systems having 30
Minutes battery Backup with each UPS System with MS Rack, Interlink
Cables and DC cables with all accessories. UPS shall be provided with
SNMP protocol for BMS interface.
Details of SMF Batteries:-
Sealed Maintenance free (SMF) Batteries for 30 Mins. backup with open
type MS Rack for installation of batteries and their respective battery
leads copper cables / Interlink between batteries, copper cables between
UPS & batteries, DC Isolator, with suitable size of Rack for batteries (as
per battery manufacturer's standard) and etc. as required. Make :- Exide
/ Quanta/ Amaron.

Isolation ;- Inbuilt at the input side of UPS System.


Back-up time :- 30 min. with SMF Batteries upto 0.99 Load Power
Factor
VAH required :- Suitable size VAH for 20 KVA
Display :- Should have LCD Display
Upgradeability :- Should be upgradable to work as parrallel redundent
UPS in load sharing mode.
30 Minutes on Full Load. ( calculation need to be provided ) as per OEM
( Battery Configuration has to be mentioned ) with racks
Display : Should have LCD display with event logging facility.
Flexi DC Bus of 30 to 44 Nos of 12 V SMF batteries to be available.

Should be Parallable in the Eco Mode configuration


The Energy Efficenecy requirment of UPS system at 100 Load shall be
vary from 91.9% to 93.8% or more.
Input Frequecy Range: 40-70 Hz
Including 5 (3P+2N+2E) runs of suitable size copper cable from the
circuit breaker in UPS room to the UPS and from UPS to the UPS panel.

Total cost of 100 KVA UPS with batteries and other acessories
each 3.00 360000.00 1080000 3 360000 1080000
DG SET
2 Supply, installation, testing and commissioning of 200 kVA 415V Diesel
Generating Set with AMF Control Panel, Water cooled, three phase as
Nos 1.00 2550000.00 2550000 1 2550000 2550000
Per CPWD specification and CPCB-II Norms with minimum 1 years
warranrty as per OEM specifications.
IP EPABAX SYSTEM 0 0
3 Supply,installation,testing and commisioning of Redundant IP based on
IP core with hot standby configuration & geographical redundancy
support . System shall support Busy hour call completion 3,00,000.0
calls . IPv6 support from day 1 and model shall be TEC approved along
with the following specifications:
1. 100 IP Extensions with CLI Expandable to 250 Ports
2. 16 IP Port trunk with CLI and Power Failure Transfer and with
Protection modules.
3. 02 PRI. Nos 2.00 1550000.00 3100000 2 1550000 3100000
4. 02 nos Operator Console with 30 Direct selection Keys each.
5. 08 Port Voice Guidance to announce Extension Busy status, Wake up
call announcement and other important telephone features, Auto
Attendant facility for Welcome message announcement.
6. 02Nos -100 pair MDF(wall mountable)
7. 01 No. Call Billing and monitoring Software.
8. Charger/UPS with Batteries for backup of 1 hour.

LAN SYSTEM 0 0
3A Supply, installation, testing and commissioning of 63 kVA 415V Diesel
Generating Set with AMF Control Panel, Water cooled, three phase as
No 1.00 6,05,000.00 605000 1 605000 605000
Per CPWD specification and CPCB-II Norms with minimum 1 years
warranrty as per OEM specifications.
4 Supply,installation,testing and commisioning of 12 port unmanaged
No 13.00 21,865.00 284245 13 21865 284245
ethernet switch with 2 nos fiber ports
5 Supply,installation,testing and commisioning of 24 port unmanaged
No 28.00 32,889.00 920892 28 32889 920892
ethernet switch with 2 nos fiber ports
6 Supply,installation,testing and commisioning of Cat-6 shuttered 12 port
No 10.00 4,111.00 41110 10 4111 41110
fully loaded patch panel with 2 nos fiber ports
7 Supply,installation,testing and commisioning of 24 port Patch panel
No 39.00 4,581.00 178659 39 4581 178659
fully loaded, Cat-6 UTP Keystone Type.
8 Supply,installation,testing and commisioning of Cat-6 UTP 24AWG
No 1250.00 288.00 360000 1250 288 360000
patch cord, 1 meter, Plug 30U, snaglless etc as required.
9 Supply,installation,testing and commisioning of Cat-6 UTP 24AWG
No 204.00 327.00 66708 204 327 66708
patch cord, 2 meter, Plug 30U, snaglless etc as required.
10 Supply , Installation , Testing and Commissioning of 24 PoE
10/100/1000 BaseT, 2 SFP+ 1G/10G ports, one expansion slot. Includes
No 11.00 54,815.00 602965 11 54815 602965
an internal 390W PoE PSU, power cord, manuals access card, RJ-45 to
DB-9 adaptor with 2 nos fiber ports
11 Supply,installation,testring and commisioning of Floor mounted 42 U
Server Rack along with all standard accessories 800mm (W), 800mm
(D), approx. Wt.150 Kg, CRCA 'D' grade 1.6mm thick sheet, pwoder
coated for cabinet RAL- 9002, 4mm Toughened Tinted Glass Door and
along with following accessories:-
1. Cooling fan 220/230V AC, of 90 CFM-------4 Nos.
2. Cable manager Metal 4 Nos.
3. PDU- 230V /AC 1 No.
4. Cable Channel 100mm wide. 2 Nos.
5. Heavy Duty Stationary Shelf 600mm(W)X475mm(D) -1
6. Mounting Hardware (20 Sets of M-6 screws, washers,cage, nuts
(Nickle Coated)- 3 Nos.
7. Earthing strips copper 150mm H 1 No.
8. Door Lock 1 No.
9. Caster Wheels (with breake) 2 Nos.
10. Caster Wheels (without breake) 2 Nos.
11. Front Metal Band 1 No
42 U Network Rack as mention above No 5.00 85,374.00 426870 5 85374 426870
12 Supply,installation,testring and commisioning of 24 port LIU with SFP
Modules with 1 U rack size(SC)-SM having LC connection with all
No 6.00 21,988.00 131928 6 21988 131928
accessories including splice tray, LC adapter plate and pigtail.

13 Supply, installation, testing and commissioning of LC -LC duplex 3


No 30.00 1,919.00 57570 30 1919 57570
meter fiber patch cord.
14 Supply, installation, testing and commissioning of multi mode fiber trans
No 27.00 10,962.00 295974 27 10962 295974
receiver.
15 Supply & laying of 6 Core Multimode Indoor OM2 Lazer 50/125 micron
Meter 1300.00 97.00 126100 1300 97 126100
Indoor Fiber cable in existing pipe.
CONFERENCE SYSTEM 0 0
16 Supply, Installation,Testing & Commissioning of Projection System with
LCD Technology with native resolution of 1280 x 800 , 5000 ANSI
Each 2.00 177564 355127.955 2 177563.9775 355127.955
lumens , 16:10 aspect ratio. Contrast 2000:1 and above. Projector Should
be supplied with Ceiling Mount Kit
17 Supply, Installation,Testing & Commissioning of 120" Diagonal
Each 2.00 66587 133173.6315 2 66586.81575 133173.6315
Motorized Projector Screen with Tensioned
18 Supply, Installation,Testing & Commissioning of 55 " Flat Panel
Professional Display with speaker and Brightness 350 nits (cd/m2)
Each 2.00 81383 162766.7633 2 81383.38163 162766.7633
typical , Contrast ​1200:1 full field, Resolution ​1920 x 1080 (16:9) . With
Wall mounting kit. as per technical specification.
19 Supply, Installation,Testing & Commissioning of Cable Cubby (1
Each 8.00 18348 146786.913 8 18348.36413 146786.913
HDMI,1 VGA , 1 Power, 1 lan).
20 Supply Installation Testing & Commissioning of 5"+1.5" Coaxial Ceiling
speaker with ABS cover, 30W, 100V, cutout 185mm, ABS baffle & back
cover, metal grille. The Speaker shall have following Feature: Max SPL Each 8.00 6215 49717.395 8 6214.674375 49717.395
> 102 dB, Frequency Response 90-20kHZ. The Speaker shall have
Multiple tapping
21 Supply, Installation,Testing & Commissioning of handheld Wireless
Mic system set with two transmitters dynamic microphone, Frequency
Response 40Hz-20,000 Hz, Dynamic Range >100dB, THD < 0.5%, S/N Each 2.00 50310 100620.0195 2 50310.00975 100620.0195
ratio > 105dB, Carrier frequency range 200 - 270 MHz, Power
Consumption < 85mA.
22 Supply Installation testing and comisioning of 120W RMS Dual Channel
Class-D Digital Power Amplifier with Switch power technology for
power electricity saving, Separate PFC Design for highest reliability,
Separate Power Supply System. Amplifier shall have Following Features:
120W RMS per Channel, Amplifier Output 100V, Supply input AC 220 Each 2.00 102100 204199.2225 2 102099.6113 204199.2225
+/- 10% - 50/60Hz, Short Circuit, Power, Tempreature, Overload
Protection, Auto Cooling Fans. THD <0.1%, Frequency Response 40Hz -
20kHz, AC & DC Fuse, SNR >80dB.

23 Supply Installation Testing & Commissioning of 8-channel Phantom


Power Microphone/Line input, 8- channel circuit Output; Loudspeaker
Management System Frequency Response 20Hz ~ 20KHz, THD
<0.003%, Channel Seperation >92dB,Seperate Mute Control each
channel,CMRR>80dB, 8 independent parametric EQ, adjustable gain
range up to 20dB, With, RS232 and internet to connect PC,High-speed Each 2.00 244151 488301.5865 2 244150.7933 488301.5865
processing DSP Chip, the new generation of AFC algorithm to eliminate
the feedback faster and make system more stable.Application includes
Auto Mixer (Limiter threshold and Gain), Routing, Audio Processing
and special signal extension Processing.
24 Supply, Installation,Testing & Commissioning of Intelligent conference
system .it can support 60 units delegate and chairman microphone, it
could be extended to support 200 units microphone by adding more
Extension power supply unit , suitable for government, restaurants,
conference rooms, training and education, the board of directors of the Each 2.00 273745 547489.1468 2 273744.5734 547489.1468
company meeting room with Frequency response 100 Hz - 16000 Hz,
Input Voltage 18V, Limit Switch and Free speech Mode.

25 Supply, Installation,Testing & Commissioning of Intelligent conference


system, Flush mount boundry layer delegate microphone unit, speaking
button, LED for the indication and with Frequency Response 40Hz - Each 8.00 37584 300674.829 8 37584.35363 300674.829
16KHz, Sensitivity -42dB±2dB,Reference sound-receiving distance 20-
120cm.
26 Supply Installation Testing & Commissioning of Touch Control
Network Controller System with 32-bit embedded processor of frequency
max 533MHz, built-in 8M memory storage and 16M FLASH storage, to
be high-speed computing complex logic instructions. Its highly
integrated chip to support to the CPU, allowing a variety of complex
arithmetic and control to run smoothly. 8 independent programmable RS- Each 2.00 287062 574123.095 2 287061.5475 574123.095
232 control interface, 8 independent programmable IR infrared
transmitter port, 8 -channel digital I / 0 input and output port, with
protection circuit, 8 -channel low current relay control interface,
Embedded intelligent IR learning module,

27 SITC of Infrared Cable for Integration with IR Devices Each 2.00 2959 5918.367 2 2959.1835 5918.367
28 Supply Installation Testing & Commissioning of 8 Port Wifi Router Each 2.00 3551 7102.29975 2 3551.149875 7102.29975
Supply Installation Testing & Commissioning of Blu ray DVD Player
29 Each 2.00 6659 13317.6225 2 6658.81125 13317.6225
Supply & Fixing of 2 Core 1.5 Sq MM Speaker Cables. Flexible Copper
30 Conductor of cross section 1.5 Sq. mm / 2.5 Sq. mm insulated, RM 200.00 61 12189.45 200 60.94725 12189.45
PVCFRLS sheathed control Cable as per IS 694
31 Supply & Fixing of 18 AWG -24/0.20mm x 2 core Microphone Cable
RM 100.00 62 6224.4 100 62.244 6224.4
32 Supply & Fixing connectors required Lot 2.00 36992 73984.7745 2 36992.38725 73984.7745
33 Supply,installation,testring and commisioning of 12U rack with Front
glass door, Rear Perforated door with handle Lock & key. Front/Rear 19"
Each 2.00 3575 7150 2 3575 7150
mounting angles, top, bottom open, RAL 9005 with all other accessories

34 Supply,installation,testring and commisioning of HD Video Conference


System Omnidirection Microphone as per technical specification. Full
duplex echo cancelling depth: 65dB; Full duplex echo cancelling time:
500 ms; Dual Noise Compression: 18dB; Line echo cancelling depth:
25dB; Line echo cancelling time: 32 ms.Microphone frequency Each 2.00 51591 103181.1008 2 51590.55038 103181.1008
response: 100Hz-20KHz Microphone pickup range: 5 m Microphone
pickup angle: 360 degree,Microphone QTY: 4 pcs , Speaker frequency
response: 100Hz-20KHz.

BUILDING MANAGMENT SYSTEM 0 0


Server for BMS software 0 0
35 Supply, installation, testing and commissioning of core i7-4790k or
Xeon E5-1650 v3 processor, Memory of 32 GB, Hard disk size (2x 800
GB Professional/Enterprise SSD with SATA or SAS), Giga speed
Network card with 2 GB Graphic card of Resolution 2.560 x 1600 with
Onboard Intel 4600 HD Windows 8.1, 64 bit Edition or Windows Server
2008 R2 and original anti virus software with 22" Monitor Full HD with Nos. 2.00 202876 405751.5 2 202875.75 405751.5
Resolution 1920x1080 as per Tender Specifications. Accessories
included Optical Mouse, Key Pad, Laserjet colour A4 printer with the
above BMS System configuration.

36 Supply, installation, testing and commissioning of 500 VA UPS with half


Nos. 2.00 76133 152265 2 76132.5 152265
an hour battery backup. (Approved Make: REPUTED)
BUILDING MANAGEMENT SYSTEM WEB-BASED SERVER
0 0
SOFTWARE
37 Supply, installation, testing and commissioning of the multi user with
simultaneous minimum 5 user web based Server license Software for
Building Management System with dynamic graphics. The Web-Based
Server software shall permit use of Standard Web-Browsers such as Lot 2.00 625767 1251534 2 625767 1251534
Microsoft Internet Explorer, Netscape Navigator, etc with EMAIL / SMS
OPTION AVAILABLE.

38 Supply, installation, testing and commissioning of dedicated Energy


Reporting & Analysis software capable of fetching the energy data from
energy meter and storing it the same BMS PC as per Tender Lot 2.00 245399 490798.5 2 245399.25 490798.5
Specifications.(Shall be installted with the same BMS Software).
PROGRAMMABLE & APPLICATION SPECIFIC CONTROLLER
0 0
(DDC) - UL LISTED
39 Supply, installation, testing and commissioning of Programmable and
Application specific - 32 bit, UL Listed BACnet (BTL certified) Real-
Time controllers with programmable memory, field mounted, configured
as per given Data Point summary for respective building services, and as
per given distributions. Each DDC shall have built-in Minimum of 20
IO Points (UI-8, DI-2, AO-2, DO-4, ) and further expandable using IO
Modules, the modem speed should be atleast 9600 bps on RS-232 /RJ-
45. The controller shall be housed in vandal proof lockable MS cabinets.
TThe controllers must be multi-protocol supporting open industry
standards, including BACnet IP. The controllers ought to be stand-alone
Direct Digital Controllers (DDCs) / Automation Server Controllers, with
I/O modules., no Proprietry Protocol shall not be accepted Each DDC
must have miniumum 15% spare I/O points. . No Digital output to 0 0
Analog output, Analog output to Digital output Module shall be allowed
to integrate with the system. Proprietary Protocol shall not be accepted.
No external I/O module or Multiplexer shall be allowed. The power
supply for BMS controllers must be of same make as of controller (UL
listed) using 24 VDC power for power ON, TRIAC o/p. The controller
must feature a jog-dial and a graphical display (128 x 64) with blacklight
and response time down to 10ms. DDCs shall have alarming/trending
and scheduling feature and must have storage capacity to store graphical
pages/data.

DCC controllers for VRV system centerlized controller Lot 0.00 552148 0 0 552147.75 0
DCC controllers for pressurization system Nos. 0.00 64785 0 0 64785 0
DCC controllers for ventilation fans (DDC/IO module) Lot 2.00 383657 767313 2 383656.5 767313
DCC controllers for DG system Lot 1.00 64785 64785 1 64785 64785
DCC controllers for LT Energy Meters/Breakers Lot 7.00 58896 412272 7 58896 412272
DCC controllers for Water tanks Lot 0.00 58896 0 0 58896 0
DCC controllers for Lifts Lot 4.00 58896 235584 4 58896 235584
SYSTEM INTEGRATION UNITS FOR 3RD PARTY SYSTEM
SOFTWARE INTEGRATION - UL listed Controllers. 0.00 0 0 0

40 Supply, installation, testing and commissioning of BACnet/ IP Based


System Integration unit consisting of microprocessor based controller
units as required to communicate between the Network Controller & the
individual 3rd party microprocessor system controllers like Chillers, 0.00 0 0 0
DGs, VFDs, VAV terminal units, UPS, Multifunction Digital Electronic
Meters, Fire Detection Systems, STP, Elevators etc. as per distribution
given below :
For VRV system centerlized controller on Bacnet/IP Set 0.00 47117 0 0 47116.5 0
For pressurization system on Bacnet/Modbus/MSTP lot 0.00 60859 0 0 60858.75 0
For UPS on bacnet IP/Modbus Set 2.00 48098 96196.5 2 48098.25 96196.5
For DG System points mentioned in IO summary on Modbus Set 1.00 47117 47116.5 1 47116.5 47116.5
LT Energy Meter points mentioned in IO summary on Modbus Set 7.00 60859 426011.25 7 60858.75 426011.25
Lift integartion Set 4.00 56933 227730 4 56932.5 227730
41 Supply, Installation, Testing & Commissioning of 2C X 1.0 Sq. mm,
Flexible, PVC Sheathed, Tinned Copper Cable for the Sensors( AI& AO) Rmt 300.00 62 18675 300 62.25 18675

42 Supply, Installation, Testing & Commissioning of 2C X1.0 Sq. mm,


Flexible, Shielded, PVC Sheathed, Tinned Copper Cable for the Rmt 400.00 71 28200 400 70.5 28200
Communication(DI & DO)
43 Supply, Installation, Testing & Commissioning of 2C X 1.5 Sq. mm,
Power Cable, PVC Sheathed, Flexible Cable for the Power of DDC Rmt 300.00 72 21600 300 72 21600
Panels

1 S/F of danger board fabricated from 10 gauge M.S. sheet as per E/I
NOS 5.00 85.00 425.00 5 85 425
rules.
2 S/F of shock treatment chart ( prescribed under I.E.rules ) duly
framed with glass and supported from back with hard board or soft
board with supply of all material labour T & P etc for proper completion NOS 10.00 305.00 3050.00 10 305 3050
of work.

3 Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered


rubber matting of tested quality. NOS 50.00 2550.00 127500.00 50 2550 127500
Supply and laying of aluminium conductor PVC insulated amoured
served sheathed cables 1100 Volts grade at depth of 750mm below
ground level over a cushion of 75mm. Thick sand all around and
protected with burnt bricks on sides and on top. On surface the cable run
4 shall be fixed on M.S. clamps etc. of suitable respect. The armouring of 0.00 0
the cable shall be properly connected with the earth conductor by clamps.
etc.

a 6 sq.mm 3 core Mtr. 550.00 284.00 156200.00 550 284 156200


b 10 sq.mm 4 core Mtr. 200.00 327.00 65400.00 200 327 65400
c 16 sq.mm 4 core Mtr. 200.00 343.00 68600.00 200 343 68600
d 25 sq.mm 3.5 core Mtr. 200.00 373.00 74600.00 200 373 74600
e 35 sq.mm 3.5 core Mtr. 100.00 422.00 42200.00 100 422 42200
f 50 sq.mm 3.5 core Mtr. 1650.00 492.00 811800.00 1650 492 811800
g 70 sq.mm 3.5 core Mtr. 200.00 613.00 122600.00 200 613 122600
h 95 sq.mm 3.5 core Mtr. 100.00 700.00 70000.00 100 700 70000
i 120 sq.mm 3.5 core Mtr. 1850.00 824.00 1524400.00 1850 824 1524400
j 150 sq.mm 3.5 core Mtr. 1750.00 957.00 1674750.00 1750 957 1674750
k 185 sq.mm 3.5 core Mtr. 1950.00 1140.00 2223000.00 1950 1140 2223000
l 240 sq.mm 3.5 core Mtr. 520.00 1379.00 717080.00 520 1379 717080
m 300 sq.mm 3.5 core Mtr. 650.00 1613.00 1048450.00 650 1613 1048450
0.00 0
Supply and fixing of brass nickle plated compression gland for PVC
insulated & armoured served sheathed, underground cable including
5 rubber ring etc. complete in all respect. The armouring of the cable shall 0.00 0
be properly connected with the earth as per direction of Engineer-
Incharge.
a 6 sq.mm 3 core Each 8.00 76.00 608.00 8 76 608
b 10 sq.mm 4 core Each 4.00 87.00 348.00 4 87 348
c 16 sq.mm 4 core Each 4.00 87.00 348.00 4 87 348
d 25 sq.mm 3.5 core Each 4.00 123.00 492.00 4 123 492
e 35 sq.mm 3.5 core Each 2.00 178.00 356.00 2 178 356
f 50 sq.mm 3.5 core Each 8.00 178.00 1424.00 8 178 1424
g 70 sq.mm 3.5 core Each 4.00 199.00 796.00 4 199 796
h 95 sq.mm 3.5 core Each 4.00 222.00 888.00 4 222 888
i 120 sq.mm 3.5 core Each 12.00 243.00 2916.00 12 243 2916
j 150 sq.mm 3.5 core Each 6.00 305.00 1830.00 6 305 1830
k 185 sq.mm 3.5 core Each 8.00 397.00 3176.00 8 397 3176
l 240 sq.mm 3.5 core Each 12.00 473.00 5676.00 12 473 5676
m 300 sq.mm 3.5 core Each 10.00 505.00 5050.00 10 505 5050
0.00 0
6 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip
Galvanized), Length upto 2000mm, outer pipe 50mm, inner pipe 25,
terminal dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12
SWG with Hot Dip Galvanization upto 100 micron filled with crystalline
conductive mixture (CCM) having anti corrosive & conductive property
with 50 kgs activated soil (BFC) capable of reducting the soil resistivity
with good mixture of retaining capacity along with 30cm square C.I. Each 40.00 6450.00 258000.00 40 6450 258000
frame with hinged cover & masonry husing (from electrode terminal to
switch board, cost of 25 x 3 G.I. strip with be extra)
Make: As approved in U.P.P.W.D., & C.P.R.I Certified.

7 Supply and fixing of horizontal air termination (roof conductor) of 25mm


x 3mm G.I. strip, G.I. clamps on surface complete in all respects as Metre 200.00 170.00 34000.00 200 170 34000
approved by Engineer-in-charge.
8 Supply and fixing of vertical air termination final rod comperising of
300mm long x 25 mm dia. Coper rod with one one pointed prong and Each 10.00 1330.00 13300.00 10 1330 13300
100mm dia x 3 mm thick base plate etc complete in all respect.
9 Supply and fixing of vertical down conductor of 32mm x 6mm G.I. strip
etc on approved clamps on surface for lighting conductor complete in all Metre 200.00 310.00 62000.00 200 310 62000
respect ( for two storyed buildings)
10 As in item 713(A) but for three or four storyed buildings Metre 0.00 355.00 0.00 0 355 0
11 As in item 713(A) but for five and above storyed buildings Metre 0.00 390.00 0.00 0 390 0
12 Supplying & Laying of 25mm x 3mm. G.I. strip for earthing purpose as
required complete in all respects. M 2000.00 90.00 180000.00 2000 90 180000

13 Supply and fixing of one number 8 SWG G.I. wire in 15mm dia G.I. pipe
for earthing, laid in ground or in wall duty concealed including the cost
of cement, sand, labour, T&P other material required for proper M 4000.00 200.00 800000.00 4000 200 800000
completion of the work as directed at site.

14 Supply and fixing of decorative 40 to 45 Watt LED Post top indirect light
luminaire having Pressure die cast aluminium body and Clear glass with
Each 4.00 8410.00 33640.00 4 8410 33640
driver set
confirming to IP 65 and above protection complete in all respect.
15 Supply and fixing of factory wired integral LED flood light luminaires
with die cast aluminium housing built with dirver set suitable for 140 to
Each 36.00 13190.00 474840.00 36 13190 474840
150 Watt. Confirming to IP 66 protection complete in all respect.

16 Supply and fixing of factory wired integral LED flood light luminaires
with die cast aluminium housing built with dirver set suitable for 170 to
Each 36.00 22750.00 819000.00 36 22750 819000
200 Watt. Confirming to IP 66 protection complete in all respect.

17 Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia
70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm
thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation Each 10.00 14750.00 147500.00 10 14750 147500
bolt including the cost of foundation, excavation & back filling and
Required T&P completee in all respect.
18 Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia
70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm
thikness with single arm bracket (1 Mtr length) on RCC foundation
including the cost of foundation, foundation bolts, excavation & back Each 12.00 20890.00 250680.00 12 20890 250680
filling and Required T&P completee in all respect.

19 Supply and fixing of LED Street light Fitting having


die cast aluminium body and diffuser with driver set
Each 10.00 4940.00 49400.00 10 4940 49400
suitable for 45 watt to 50 Watt. Confirming to IP 66
protection complete in all respect..
20 Supply and fixing of LED Street light Fitting having
die cast aluminium body and diffuser with driver set
Each 12.00 8850.00 106200.00 12 8850 106200
suitable for 75 to 90 Watt. Confirming to IP 66 and
above Protection complete in all respect.
21 Supply & fixing of 20 mtr High mast shaft of approved
make with rising system hot dip glavanized inside & out
side dip,heaving pole sheet thickness 4 mm. Top dia
minium 150 mm, Bottom dia 410 mm base plate 32 mm
thick suitable for wind velocity as per IS 875 part 3 &
having no circumferential weld, with accessories for
high mast such as head frame suitable for 6 to 12 Each 6.00 314000.00 1884000.00 6 314000 1884000
luminaries & its control gear boxes 1.5 HP power tool
moter, 3 point suspension system with steel wire rope 8
mm dia, double drum winch, including making suitable
foundation as per manufature drawing/ site reuiment
along with foundation bolts nuts, washers, anchor plates
etc completee in all respect.
T O T A L (SCHEDULED ITEMS - UPPWD - 2018) 0.00 [A] 0 [A]
PART-C MARKET RATE ITEMS 0.00 0
UPS 0.00 0
1 Supply, installation, testing and commissioning and testing of 10KVA
N+1, 415V, 3ph input & 3 ph output ON-LINE UPS system back up
0.00 0
protection for 30 minutes as per EN/ IEC standared with all accessories
as required.
Details of UPS :- 0.00 0
(IGBT based rectifier & inverter) True Online UPS Systems having 30
Minutes battery Backup with each UPS System with MS Rack, Interlink
0.00 0
Cables and DC cables with all accessories. UPS shall be provided with
SNMP protocol for BMS interface.
Details of SMF Batteries:- 0.00 0
Sealed Maintenance free (SMF) Batteries for 30 Mins. backup with open
type MS Rack for installation of batteries and their respective battery
leads copper cables / Interlink between batteries, copper cables between
UPS & batteries, DC Isolator, with suitable size of Rack for batteries (as 0.00 0
per battery manufacturer's standard) and etc. as required. Make :- Exide
/ Quanta/ Amaron.

Isolation ;- Inbuilt at the input side of UPS System. 0.00 0


Back-up time :- 30 min. with SMF Batteries upto 0.99 Load Power
0.00 0
Factor
VAH required :- Suitable size VAH for 20 KVA 0.00 0
Display :- Should have LCD Display 0.00 0
Upgradeability :- Should be upgradable to work as parrallel redundent
0.00 0
UPS in load sharing mode.
30 Minutes on Full Load. ( calculation need to be provided ) as per OEM
0.00 0
( Battery Configuration has to be mentioned ) with racks
Display : Should have LCD display with event logging facility. 0.00 0
Flexi DC Bus of 30 to 44 Nos of 12 V SMF batteries to be available.
0.00 0
Should be Parallable in the Eco Mode configuration 0.00 0
The Energy Efficenecy requirment of UPS system at 100 Load shall be
0.00 0
vary from 91.9% to 93.8% or more.
Input Frequecy Range: 40-70 Hz 0.00 0
Including 5 (3P+2N+2E) runs of suitable size copper cable from the
circuit breaker in UPS room to the UPS and from UPS to the UPS panel. 0.00 0

Total cost of 100 KVA UPS with batteries and other acessories
each 1.00 180000.00 180000 1 180000 180000
LAN SYSTEM 0.00 0 0 0
2 Supply,installation,testing and commisioning of 12 port unmanaged
No 2.00 21865.00 43730 2 21865 43730
ethernet switch with 2 nos fiber ports
3 Supply,installation,testing and commisioning of 24 port unmanaged
No 6.00 32889.00 197334 6 32889 197334
ethernet switch with 2 nos fiber ports
4 Supply,installation,testing and commisioning of Cat-6 shuttered 12 port
No 2.00 4111.00 8222 2 4111 8222
fully loaded patch panel with 2 nos fiber ports
5 Supply,installation,testing and commisioning of 24 port Patch panel
No 9.00 4581.00 41229 9 4581 41229
fully loaded, Cat-6 UTP Keystone Type.
6 Supply,installation,testing and commisioning of Cat-6 UTP 24AWG
No 200.00 288.00 57600 200 288 57600
patch cord, 1 meter, Plug 30U, snaglless etc as required.
7 Supply,installation,testing and commisioning of Cat-6 UTP 24AWG
No 46.00 327.00 15042 46 327 15042
patch cord, 2 meter, Plug 30U, snaglless etc as required.
8 Supply , Installation , Testing and Commissioning of 24 PoE
10/100/1000 BaseT, 2 SFP+ 1G/10G ports, one expansion slot. Includes
No 6.00 54815.00 328890 6 54815 328890
an internal 390W PoE PSU, power cord, manuals access card, RJ-45 to
DB-9 adaptor with 2 nos fiber ports
9 Supply,installation,testring and commisioning of Floor mounted 42 U
Server Rack along with all standard accessories 800mm (W), 800mm
(D), approx. Wt.150 Kg, CRCA 'D' grade 1.6mm thick sheet, pwoder 0.00 0 0 0
coated for cabinet RAL- 9002, 4mm Toughened Tinted Glass Door and
along with following accessories:-
1. Cooling fan 220/230V AC, of 90 CFM-------4 Nos. 0.00 0 0 0
2. Cable manager Metal 4 Nos. 0.00 0 0 0
3. PDU- 230V /AC 1 No. 0.00 0 0 0
4. Cable Channel 100mm wide. 2 Nos. 0.00 0 0 0
5. Heavy Duty Stationary Shelf 600mm(W)X475mm(D) -1 0.00 0 0 0
6. Mounting Hardware (20 Sets of M-6 screws, washers,cage, nuts
0.00 0 0 0
(Nickle Coated)- 3 Nos.
7. Earthing strips copper 150mm H 1 No. 0.00 0 0 0
8. Door Lock 1 No. 0.00 0 0 0
9. Caster Wheels (with breake) 2 Nos. 0.00 0 0 0
10. Caster Wheels (without breake) 2 Nos. 0.00 0 0 0
11. Front Metal Band 1 No 0.00 0 0 0
42 U Network Rack as mention above No 1.00 85374.00 85374 1 85374 85374
10 Supply,installation,testring and commisioning of 24 port LIU with SFP
Modules with 1 U rack size(SC)-SM having LC connection with all
No 2.00 21988.00 43976 2 21988 43976
accessories including splice tray, LC adapter plate and pigtail.

11 Supply, installation, testing and commissioning of LC -LC duplex 3


No 12.00 1919.00 23028 12 1919 23028
meter fiber patch cord.
12 Supply, installation, testing and commissioning of multi mode fiber trans
No 9.00 10962.00 98658 9 10962 98658
receiver.
13 Supply & laying of 6 Core Multimode Indoor OM2 Lazer 50/125 micron
Meter 600.00 97.00 58200 600 97 58200
Indoor Fiber cable in existing pipe.

Design, comply to IEC 62271-100/200 ,Supply, Installation, Testing and


Commissioning of One Incomer and three outgoing intdoor type, 630
A, 33KV, 3 Phase, 50 Hz, earthedl Vacuum Circuit Breaker motor
operated, expandable type, type tested design enclosure (IP54) , load
bearing section of enclosure made of CRCA coated sheet steel, fully
Interlocked, Indoor industrial pattern, Metal clad, trolley mounted
14 Horizontal isolation, Horizontal draw out circuit breaker, floor mounting,
earthing trolley 1no. each for cable and bus earthing, copper bus bar with
heat shrink sleeves. The switchboard shall be suitable for short circuit
current and Major sub components should be of same make.

INCOMER : - 1 NO each equipped with the following :


Vacuum Circuit Breaker
33KV 630A 3P 31.5 kA as incomer
Current Transfomer-
Dual Core CT 31.5 kA for 1 sec : CT 33KV 100/5A 15VA Core-1
CL:0.5, Core-2 CL :5P10
Potential Transformer-
33kV/1.732 / 110V/1.732 , Class 1, 100VA
Relays- Schneider( Micom P127) /Siemens (7SJ62) or EQ.
IDMT 3 O/C + 1 E/F RELAY
Over voltage relay
Under voltage relay
Restricted earth fault relay
Master trip relay
METERS with required CTs
Digital Ammeter with selector switch (0-100A)
Digital Voltmeter with selector switch (0-15KV)
Multi Function Digital Meter EM6400NG
Set of indication Lamps-
Red-ON
Green-OFF
White-Trip Circuit Healthy
Amber-Trip Condition
Set of wiring, Ferrules & Fuses Power-Pack 110/24V DC Supply for
simultaneous tripping of three breakers.
Space provision with locking arrangement for providing HT metering
(TOD, CT & PT) as per KSEB requirment including all necessary
accesiories.
BUSBAR-
800A TP 33KV 31.5 KA Copper Busbars with heat shrinkable insulation
sleeves
OUTGOING :- 3 Nos each equipped with the following:
Vacuum Circuit Breaker
33KV 630A 3P 31.5 kA
Current Transfomer-
Dual Core CT 31.5 kA for 1 sec : CT 33KV 50/5A 15VA Core-1
CL:0.5, Core-2 CL :5P10
Relays- Schneider( Micom P122) /Siemens (7SJ62) or EQ.
IDMT 3 O/C + 1 E/F RELAY
Restricted earth fault relay
Transformer Fault Alarm/Trip Aux. Relay
Master trip relay
METERS with rerequired CTs
Digital Ammeter with selector switch
Digital Entergy meter
Multi Function Digital Meter EM6400NG
Set of indication Lamp-
Red-ON
Green-OFF
White-Trip Circuit Healthy
Amber-Trip Condition, Set of wiring, Ferrules & Fuses Power-Pack
110/24V DC Supply for simultaneous tripping of three breakers.

The item shall also include all necessary control and low power cabling
between the HT panel and LT panels.
In addition 33kV HT panel shall be with all requirements as per the
Nos 1.00 1550000.00 1550000 1 1550000 1550000
guidelines by Local E.B authorities and Electrical inspectorate.

Supply, installation, testing and commissioning of 2000 kVA,


33kV/433V, 3 phase, 50 Hz, Delta star, DYn11, Dry type, cast resin,
indoor, natually cooled, copper double wound transformer with Off load
tap changer from +5% to -15% in steps of ±2.5%, class F insulation,
complete with WTI and scanner for alarm & trip, unidirectional rollers,
cable end box for termination of HT cables & Bus duct for LT side
complete with rating and technical name plate, earthing terminals with
lugs, lifting lugs in all respect with all necessary standard accessories and
as per IS 11171. The transformer shall have suitable enclosure for
15 providing neutral CT on earthed star point with connector for connection
to REF relay provided in Main panel. All routing test as per IS shall be
conducted on the transformer. The Transformer Enclosure shall have
suitably designed Louvers for Air Circulation & efficient Cooling. The
enclosure shall be Epoxy Powder coated. The transformer shall be
subjected to all routine tests as per IS/IEC standards. Type test certificate
shall be submitted. The transformer shall meet latest ECBC
requirments.The transformer having permisible losses as per ECBC 2017
or updated.

2000 KVA Nos 2.00 3141107.00 6282214 2 3141107 6282214

MAIN PANEL
16 Supply, Installation, Testing & Commissioning of Main LT panel,
cubicle type, made out of min 2mm thick CRCA sheet (load bearing),
totally enclosed, IP42, free standing, floor mounting, dust and vermin
proof, powder coated, indoor, compartmentalised, suitable for operation
on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable
on both sides, including internal wiring with suitable size wires, rotary
handle, spreaders, 3mm thick gland plate, hinged type door with
neoprene / PU gasket, IS 8623 etc. The panel shall include supply &
installation of following switchgears, metering instruments and
accessories as per specification. The panel shall be suitable for receiving
Cable / Bus duct to the incomer ACB. Panel shall have potential free
contacts to interface with BMS.

Incomer
3000A, FP, 50kA, microprocessor based ACB electrical operated,
drawout type, motorised, with overload, instantaneous SC, delayed SC,
and ground fault protection with necessary communication port, shunt
trip coil, U/V release etc - 2 nos.
Neccesary provision and control cabling shall be done to trip LT panel
incomer on failure of 11kV HT supply.
Bus Coupler
3000A, FP, 50kA, ACB electrical operated, drawout type, motorised
with out protection with necessary communication port, shunt trip coil
etc - 1 no.
Busbar
8000 A TPN 50KA busbars of high conductivity electrolytic quality
copper alloy and suitable size earthing conductor through out the panel
for its earthing. Bus Bar Shall have 100% neutral.
Instruments
2A, C curve SP MCB - 4 set
RYB indication lamp, LED type - 4 set
On/Off, Trip indication lamp, LED type - 4 set
(0-500)V voltmeter, Digital type - 4 set
(0-2500)A ammeter, Digital type - 3 set
(0-1600)A ammeter, Digital type - 3 set
4 set 3 phase Digital Multi function meter to read V, A, F, kW, PF, kWH,
Acc class 1 and with necessary communication port
(Backnet/Modbus/RS:485) suited for BMS system
Low set earth fault relay using CT of 3000/5A 15VA Cl. 5P10 with
necessary control cable from CT at transformer neutral to 51G relay in
MSB panel- 2 set
3000/5A 15VA class 1 resin cast CT - 3 set
630/5A 15VA class 1 resin cast CT for connection to APFC panel -2 set

Outgoing.
1250A, FP, 50kA, microprocessor based ACB electrical operated,
drawout type, motorised, with overload, instantaneous SC, delayed SC,
and ground fault protection with necessary communication port, shunt
trip coil, U/V release etc - 2 nos.
800A, FP, 50kA, microprocessor based ACB electrical operated, drawout
type, motorised, with overload, instantaneous SC, delayed SC, and
ground fault protection with necessary communication port, shunt trip
coil, U/V release etc - 1 nos.
630A FP 50kA MCCB with microprocessor based release with
adjustable OL, SC and EF protection - 2 no.
400A FP 50kA MCCB with microprocessor based release with
adjustable OL, SC and EF protection - 2 no.
200A FP 50kA MCCB with microprocessor based release with
adjustable OL, SC and EF protection - 4 nos.
100A FP 50kA MCCB with microprocessor based release with
adjustable OL, SC and EF protection - 2 nos.
All outgoings expect capcitor panel shall have 3 phase Digital Multi
function meter to read V, A, F, kW, kWh with Acc class 1 including
respective feeder rating CT on the outgoing feeders
The switchboard shall be complete with all inter connections, risers,
Nos 1.00 2550000.00 2550000 1 2550000 2550000
internal wiring, labels etc complete as required
17 Supply, Installation, Testing & Commissioning of 600 kVAR APFC
panel, cubicle type, made out of min 2mm thick CRCA sheet (load
bearing), totally enclosed, IP42, free standing, floor mounting, dust and
vermin proof, powder coated, indoor, compartmentalised, suitable for
operation on 3 phase and neutral, 415 V, 50Hz AC system, including
internal wiring with suitable size wires, rotary handle, spreaders 3mm
thick gland plate, hinged type door with neoprene / PU gasket etc. The 0.00 0 0 0
panel shall include supply & installation of following switchgears,
metering instruments and accessories as per specification. Required nos.
of louvers and panel mounted cooling fans with auto/ manual control
shall be provided.

Incomer 0.00 0 0 0
1600A, FP, 50kA, microprocessor based ACB electrical operated,
drawout type, motorised, with overload, instantaneous SC, delayed SC,
and ground fault protection with necessary communication port, shunt
trip coil, U/V release etc - 1 nos.
Busbar
1 Set of 2000 Amp TPN busbars of high conductivity electrolytic quality
Aluminium alloy and suitable size earthing conductor through out the
panel for its earthing.
Instruments
1 No 3 phase Digital Multi function meter to read V, A, F with Acc class
1.
1 Set of phase indicating lamps, LED type, RYB.
1 Set of 2A 10kA C curve SP control MCB
1 Set of 800/5A, Class 1.0, 5VA, Cast Resin CT for metering.
1 no. 8 stage APFC relay
7 set On, Off push button
7 set On, Off LED type indication lamp
1 set Auto / manual selector switch.
Outgoing.
2 Nos 250A, TPN, 35kA, MCCB with Thermal Magnetic release, having
adjustable OL & SC protection.
4 Nos 100A, TPN, 35kA, MCCB with Thermal Magnetic release, having
adjustable OL & SC protection.
4 Nos 63A, TPN, 35kA, MCCB with Thermal Magnetic release, having
adjustable OL & SC protection.
2 Nos. 100 kVAR MPP heavy duty capacitor with capacitor duty
contactor & 7% detuned harmonic filter.
4 Nos. 50kVAR MPP heavy duty capacitor with capacitor duty contactor
& 7% detuned harmonic filter.
3 No. 25 kVAR MPP heavy duty capacitor with capacitor duty contractor
and 7% detuned harmonic filter.
1 No. 25 kVAR MPP heavy duty capacitor with 7% detuned harmonic
Nos 2.00 720000.00 1440000 2 720000 1440000
filter directly connected.

18 Supply, Installation, Testing & Commissioning of Main Lift Panel,


cubicle type, made out of min 2mm thick CRCA sheet (load bearing),
totally enclosed, IP42, free standing, floor mounting, dust and vermin
proof, powder coated, indoor, compartmentalised, suitable for operation
on 3 phase and neutral, 415 V, 50Hz AC system, including internal
wiring with suitable size wires, rotary handle, spreaders, 3mm thick
gland plate, hinged type door with neoprene / PU gasket, IS 8623 etc.
The panel shall include supply & installation of following switchgears,
metering instruments and accessories as per specification.

Incomer
200A FP 35kA MCCB with microprocessor based release with
adjustable OL, SC and EF protection - 1 nos.
Busbar
1 Set of 250 A TPN busbars of high conductivity electrolytic quality
Aluminium alloy and suitable size earthing conductor through out the
panel for its earthing.
Instruments
2A, C curve SP MCB - 3 nos.
RYB indication lamp, LED type - 3 nos.
1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh,
Acc class 1.
250/5A 5VA class 1 resin cast CT - 1 set
Outgoing.
63 A FP 25 kA MCCB, microprocessor based release having adjustable
Nos 1.00 180000.00 180000 1 180000 180000
O/L, SC protection - 7 nos.
19 Supply, Installation, Testing & Commissioning of Utility Panel, cubicle
type, made out of min 2mm thick CRCA sheet (load bearing), totally
enclosed, IP42, free standing, floor mounting, dust and vermin proof,
powder coated, indoor, compartmentalised, suitable for operation on 3
phase and neutral, 415 V, 50Hz AC system, including internal wiring
with suitable size wires, rotary handle, spreaders, 3mm thick gland plate,
hinged type door with neoprene / PU gasket, IS 8623 etc. The panel
shall include supply & installation of following switchgears, metering
instruments and accessories as per specification.

Incomer
630A FP 35kA MCCB with microprocessor based release with
adjustable OL, SC and EF protection - 1 nos.
Busbar
1 Set of 650 A TPN busbars of high conductivity electrolytic quality
Aluminium alloy and suitable size earthing conductor through out the
panel for its earthing.
Instruments
2A, C curve SP MCB - 3 nos.
RYB indication lamp, LED type - 3 nos.
1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh,
Acc class 1.
630/5A 5VA class 1 resin cast CT - 1 set
Outgoing.
250A FP 35kA MCCB with microprocessor based release with
adjustable OL, SC and EF protection - 2 nos.
200 A 4P 35kA MCCB,microprocessor based release having adjustable
O/L, SC protection - 1 nos.
160 A 4P 35kA MCCB, microprocessor based release having adjustable
O/L, SC protection - 1 nos.
100 A 4P 35kA MCCB, microprocessor based release having adjustable
Nos 1.00 220000.00 220000 1 220000 220000
O/L, SC protection - 2 nos.

20 Supply, Installation, Testing & Commissioning of Street lighting panel,


cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free
standing, floor mounting, dust and vermin proof, powder coated, outdoor
type, compartmentalised, suitable for operation on 3 phase and neutral,
415 V, 50Hz AC system, including internal wiring with suitable size
wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door
with neoprene gasket, IS 8623 etc. The panel shall include supply &
installation of following switchgears, metering instruments and
accessories as per specification.

Incomer
63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz,
complete with handle assembly having door interlock - 1 no.
Busbar
1 Set of 100 A TPN busbars of high conductivity electrolytic quality
Aluminium alloy.
Instruments
2A, C curve SP MCB - 3 nos.
RYB indication lamp, LED type - 3 nos.
1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.

63/5A 5VA class 1 resin cast CT - 1 set


Outgoing.
40A TP+NL C curve MCB - 1 nos.
16A TP+NL C curve MCB - 6 nos.
Necessary space provision and control wiring for satisfactory operation
of Astronimical time switch for automatic switching ON & OFF of street Nos 1.00 55000.00 55000 1 55000 55000
lights.

21 Supply, Installation, Testing & Commissioning of Feeder Pillar, cubicle


type, made out of 2mm thick CRCA sheet, totally enclosed, free
standing, floor mounting, dust and vermin proof, powder coated, outdoor
type, compartmentalised, suitable for operation on 3 phase and neutral,
415 V, 50Hz AC system, including internal wiring with suitable size
wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door
with neoprene gasket, IS 8623 etc. The panel shall include supply &
installation of following switchgears, metering instruments and
accessories as per specification.

Incomer
200A FP 35kA MCCB with microprocessor based release with
adjustable OL, SC and EF protection - 1 nos.
Busbar
1 Set of 250 A TPN busbars of high conductivity electrolytic quality
Aluminium alloy.
Instruments
2A, C curve SP MCB - 3 nos.
RYB indication lamp, LED type - 3 nos.
1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.

200//5A 5VA class 1 resin cast CT - 1 set


Outgoing.
100 A 4P 35kA MCCB, microprocessor based release having adjustable
O/L, SC protection - 2 nos.
63 A 4P 35kA MCCB, microprocessor based release having adjustable
O/L, SC protection - 2 nos.
Necessary space provision and control wiring for satisfactory operation
of Astronimical time switch for automatic switching ON & OFF of street Nos 2.00 95000.00 190000 2 95000 190000
lights.

22 Supply of 33kV (E) grade HFFR XLPE insulated sheathed compact


circular armoured aluminium conductor HT power cable, insulation
screened with extruded semi conducting compound in combination with
copper tape suitable for 33kV earthed system confirming to relavent
standard.
3 x 240 sq. mm Al. XLPE m 1000.00 1746.00 1746000 1000 1746 1746000

23 Supply and Fixing of All in One solar system with aesthetically


CIRCULR design luminaire & 4-6 MTR Solar Pole. 2500Lm Solar
Cirucular Light with Efficacy- 100lm/w. Life expectacy above 50,000Hr
, colour temperature 4000K, Standard Light Profile 6H 100% + 6H 50%,
Working Temperature -10 to +60 degree, IP67 (Min) CRI>70 Battery
capacity 60Ah LiFePo4, Life Cycle 2000 @90% DOD with IP68
Dimension 120x146x470mm 8.5Kg, Average Lighting beam angle
120degree, PV Module- Mono-Si, 180Wp/23Voc Dimension
172x172x2000mm, Solar cell Efficiency 16.4%, 4 site String, Total
Column Length 4Mtr,Aluminium bottom Aluminium housing powder
coated Part 2Mtr, Solar PV Module 2Mtr, Remote Monitoring, Run time
Extension, Total Nominal Peak power O/P 180Wp, Luminaire Housing
Pressure die cast aluminium with corrosion Resistance Polyester powder nos 43.00 123602.00 5314886 43 123602 5314886
coated, Impact Resistance >IK07, Lamp starting time should be not more
than 10Seconds. Thermal managment system should be provided and
LED must be mounting on neat sink condutive aluminium with suitable
large are surface be means of fins to dissipate the heat to ambient air.
Applications standard Fixture should confirm to applicable IEC 60598-1
IEC 61000-3-2, IEC 61547, Test compliance for LED is LM 80 (IS-
16105) and Test comliance at the time of delivery, tenderer shall submit
all technical test report as technical bid for the same at the time of
internal wiring fiber glass insulated multi stand wire. Protection
overvoltage

24 Supply and Fixing of All in One solar system with aesthetically design
luminaire & 6-8 MTR Solar Pole. 6000Lm Solar Light with Efficacy-
135lm/w. Battery capacity 100Ah LiFePo4, Life Cycle 2000 @ 90%
DOD with IP68 Dimension 120x146x470mm 12.2Kg, Life expectacy
above 50,000Hr , colour temperature 4000K, Standard Light Profile 6H
100% + 6H 50%, Working Temperature -10 to +60 degree, IP67 (Min)
CRI>70, Average Lighting beam angle 120degree, PV Module- Mono-
Si, 180Wp/23Voc Dimension 172x172x4000mm, Solar cell Efficiency
16.4%, 8 site String, Total Column Length 6Mtr,Aluminium housing
powder coated bottom Part 2Mtr, Solar PV Module 4Mtr, Remote
Monitoring, Run time Extension, Total Nominal Peak power O/P
360Wp, Luminaire Housing Pressure die cast aluminium with corrosion
Resistance Polyester powder coated, Impact Resistance >IK07, Lamp nos 86.00 187058.00 16086988 86 187058 16086988
starting time should be not more than 10Seconds. Thermal managment
system should be provided and LED must be mounting on neat sink
condutive aluminium with suitable large are surface be means of fins to
dissipate the heat to ambient air. Applications standard Fixture should
confirm to applicable IEC 60598-1 IEC 61000-3-2, IEC 61547, Test
compliance for LED is LM 80 (IS-16105) and Test comliance at the time
of delivery, Howerer the tenderer shall submit all technical test report as
technical bid for the same at the time of submission of bid, internal
wiring fiber glass insulated multi stand wire. Protection overvoltage.

0.00 0 0 0
25 Supply and Fixing 3000 Amp TPN Sandwich alumininum bus bar
trunking complete shutable for
IP 54 protection with top end cover plate of 1.6mm thik G.I. Sheet with meter 80.00 35500.00 2840000 80 35500 2840000
sutaible arrangement for fixing
etc complete in all respect.
0 0
RISING MAIN
Supply and Fixing 400 Amp TPN Sandwich alumininum bus bar
trunking complete shutable for IP 54 protection with top end cover plate
1 of 1.6mm meter 50.00 17800.00 890000 50 17800 890000
thik G.I. Sheet with sutaible arrangement for fixing etc complete in all
respect.
Supply and erection of 100 Amp. TPN tap off box on rising mains
2 EACH 4.00 19990.00 79960 4 19990 79960
complete with HRC fuses etc. complete in all respect.
Supply and erection of incoming adopter box for mounting 100 Amp.
3 TPN CFS unit including connectors of required capacity on to the rising EACH 2.00 8780.00 17560 2 8780 17560
Mains complete in all respect.
Supply and Fixing of Flange End for 400 Amp sandwich Al bus bar
4 EACH 2.00 25750.00 51500 2 25750 51500
trunking complete in all respect.

Providing, fixing, connecting & testing of 4MP Bullet Camera as


4 EACH 2.00 9500.00 19000 2 9500 19000
required in site.

LIFT

Supply, installation, testing & commissioning of lift of following


capacities and type suitable for operation on 415 V, 3 phase, 50 Hz AC
supply, having AC variable voltage and variable frequency type, with /
without machine room, Suitable speed, electromagnetic brake system,
simple operations, operating control panel with luminous buttons,
1 overload warning indicator, battery operated alarm bell, LED type
emergency light, intercom suitable for hook up to EPABX, infrared ray
sensing door protection for full height, reverse phase relay on controller,
fireman’s switch at ground floor, ARD system, operation and
maintanance contract of same OEM for 1 year.

Digital car positions indicator in car and at all positions indicator in car
and at all floors with Up/DOWN direction, all signal fixtures in stainless
stell faceplates, light fixtures, ventilation fan, etc complete with all
accessories including automatic rescue device in the event of power
failure etc., Complete with necessary scaffolding, electrical panel, logic
control panel and shaft lighting etc required for the erection of the
elevators as required.
Machine Room Type (MR) Type with the traction motor placed in Lift
Topp (suitable as per cpwd specification, simplex full collective
operation with/without attendant. Car/Hoistway Entrance, protected by
stainless steel hairline doors and clear center /side opening min as per
a site. 13 Pasanger Lift, suitable car size Inside dimensions and entrance
at front side on all the serving floors, provided with matt finish stainless
steel panel on all four side and ceiling, stretcher protection on three
sides complete as per requirment.

2 stops & 2 openings ,Total travel height is approximately 8-10M, Speed


SET 6.00 1565000.00 9390000 6 1565000 9390000
1.5 to 2 MPS

TOTAL 53428782.00 1281686.00 77033068.82 TOTAL 53428782 1281686 77033068.82


1123793.07 1123793.073
1112666.41 1112666.409
TOTAL AMOUNT OF INTERNAL
ELECTRIFICATION ( C)
131574517.23 131574517.2 0.00

D FIRE FIGHTING WORK

Amount
S. No. Description of Item Unit TOTAL QTY Rate
UPSOR DSR 2018 NSR

1.0 Fire Fighting System


1.1 Supplying, installation, testing and commissioning of electric driven
terrace pump suitable for automatic operation and consisting of
following, complete in all respects, as required: (Terrace Pump)

Horizontal type, multistage, centrifugal, split casing pump of cast iron


body & bronze impeller with stainless steel shaft, mechanical confirming
to IS : 1520

Suitable HP squirell cage induction motor TEFC type suitable for


operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of
protection for enclosure, horiziontal foot mounted type with Class-'F'
insulation, conforming to IS-325.

M.S.fabricated common base plate, coupling, coupling guard, foundation


bolts etc.as required.

Suitable cement concrete foundation duly plastered and with anti


vibration pads.

1.1.1 900 lpm at 35 m Head Set 0 100946.00 0.00 0 100946 0


1.1.2 450 lpm at 35 m Head Set 10 85291.00 852910.00 10 85291 852910

1.2 Providing laying, testing & commissioning of 'C' class heavy duty MS
Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges,
tapers, nuts bolts, gaskets etc. in ground including welding, excavation &
providing cement concrete blocks as supports, anticorrosive treatment
with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of
following sizes complete as required.

1.2.1 100 mm dia. Metre 65 1219.00 79235.00 65.00 1219.00 79235

1.3 Providing, laying, testing & commissioning of 'C' class heavy duty MS
pipe conforming to IS 3589/IS 1239 including Welding, fittings like
elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe
on the wall/ceiling with suitable clamp/support frame and painting with
two or more coats of synthetic enamel paint of required shade complete
as required :

1.3.1 25 mm dia Metre 78 471.00 36738.00 78.00 471.00 36738


1.3.2 50 mm dia Metre 40 787.00 31480.00 40.00 787.00 31480
1.3.3 80 mm dia Metre 56 1122.00 62832.00 56.00 1122.00 62832
1.3.4 100 mm dia Metre 630 1499.00 944370.00 630.00 1499.00 944370

1.4 Supplying and fixing single headed internal hydrant valve with
instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast
iron wheel ISI marked conforming to IS 5290 (Type -A) with blank
Gunmetal/Stainless Steel cap and chain as required :

1.4.1 Single headed Stainless steel Set 58 5987.00 347246.00 58.00 5987.00 347246

1.5 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6


rating with bronze/gunmetal seat duly ISI marked complete with nuts,
bolts, washers, gaskets conforming to IS 13095 of following sizes as
required :

1.5.1 50 mm dia Set 4 3671.00 14684.00 4.00 3671.00 14684


1.5.2 80 mm dia Set 58 4842.00 280836.00 58.00 4842.00 280836
1.5.3 100 mm dia Set 16 6454.00 103264.00 16.00 6454.00 103264

1.6 Supplying and fixing orifice plate made out of 6 mm thick stainless steel
(Grade 304) with orifice of required size to be fitted between flange &
landing valve of external and internal hydrants to reduce pressure at the 58 1291.00 74878.00 1291.00 74878
outlet to the level of 3.5 kg/cm2 complete as required.
Each 58.00

1.7 Providing, installation, testing and commissioning of non-return valve of


following sizes confirming to IS:5312 complete with rubber gasket, GI
bolts, nuts,washers etc.as required :

1.7.1 50 mm dia Set 2 5646.00 11292.00 2 5646 11292


1.7.2 100 mm dia Set 8 10836.00 86688.00 8.00 10836.00 86688

1.8 Providing, installation, testing and commissioning of stainless steel Y-


strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet
with 3 mm dia holes with stainless steel flange.

1.8.1 100 mm dia Each 26 6450.00 167700.00 26.00 6450.00 167700


1.9 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm
dia male and female couplings duly bound with GI wire, rivets etc.
conforming to IS 636 (type-A) as required :

1.9.1 Stainless Steel (Grade 304) Set 116 4434.00 514344.00 116.00 4434.00 514344

1.10 Supplying and fixing first-aid Hose Reel with MS construction spray
painted in post office red, conforming to IS 884 complete with the
following as required.
20 mm nominal internal dia water hose thermoplastic (Textile
reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S.
Pipe and socket.

1.10.1 40 m Set 41 10092.00 413772.00 41.00 10092.00 413772

1.11 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm
nominal internal diameter size nozzle conforming to IS 903 suitable for
nstantaneous connection to interconnect hose pipe coupling as required :

1.11.1 Stainless Steel (Grade 304) Set 58 1648.00 95584.00 58.00 1648.00 95584

1.12 Supplying and fixing of fire brigade connection of cast iron body with
gun metal male instantaneous inlet couplings complete with cap and
chain as reqd. for suitable dia MS pipe connection conforming to IS 904
as required :

1.12.1 2 way - 100 mm dia M.S. Pipe Set 7 6590.00 46130.00 7.00 6590.00 46130

1.13 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS
sheet, 1200 mm in height with air release valve on top and flanged
connection to riser, drain arrangement with 25 mm dia gun metal wheel 21 18009.00 378189.00 18009.00 378189
valve with required accessories, pressure gauge and paintingwith
synthetic enamel paint of approved shade as required.
Set 21.00

1.14 Supplying and installing following size of perforated pre-painted M.S.


cable trays with perforation not more than 17.5%, in convenient sections,
joined with connectors, suspended from the ceiling with M.S. suspenders
including bolts & nuts, painting suspenders etc as required.

1.14.1 150 mm width x 50mm depth x 1.6 mm thickness. Metre 80 531.00 42480.00 80.00 531.00 42480

1.15 Providing and fixing of Weather proof hose cabinets fabricated from 14 g
M.S. Sheet with full glass door and mortise locking arrangement ,
suitable to accommodate one Hydrant landing valve, 2 nos. 15 M long
hose and 1 No branch pipe. The cabinet shall be painted with one coat of
primer and finished stove enamelled "Fire Red", "Fire Hose" written on 19 6698.00 127262.00 6698.00 127262
front including suitably mounted on a raised masonry platform as
required. (Approx 0.75mx0.6 m x 0.25 m).
Each 19.00

1.16 Providing and fixing MS partly glazed single/double hung lockable


shutter fabricated from MS section as required with 5 mm thick glass for
fire station complete including stove enamelled painting of door and
frame and words "Fire Hydrant" written on glass, suitable to
accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 39 6142.00 239538.00 6142.00 239538
63 mm dia hose,1-branch pipe, 1no. fire man's axe, fire extiguishers 2
nos, including suitably mounted on a raised masonry platform as
required. (Approx.size 0.90 m x 2.1m ) Each 39.00

1.17 Providing and fixing in position the industrial type pressure gauges with
58 1094.00 63452.00 1094.00 63452
gun metal / brass valves complete as required Each 58.00

1.18 Providing and fixing resilient rubber neoprene lined single arch
vibration eliminators with unit control suitable for raw water upto 450 C
temperature working pressure 25 kg and test pressure 37.5 kg/cm 2.

1.18.1 100 mm dia Each 20 5432.00 108640.00 20.00 5432.00 108640


1.19 Providing and fixing heavy duty PVC insulated, PVC armoured
conductor cables 1100 V grade including necessary support clamps and
connection lugs complete in all respects.

1.19.1 Power cable 3 core 16 sq mm aluminium conductor armoured cable.


Metre 96 104.00 9984.00 104.00 9984
96.00
1.19.2 Control cable copper 2 core 1.5 sq.mm Metre 150 62.00 9300.00 150.00 62.00 9300

1.20 Providing and fixing carbon-di-oxide type fire extinguishers consisting


of pressure tested single cast cylinder with rotary discharge valve and
high pressure discharge tube of minimum 1 m length, discharge horn,
suspension bracket conforming to IS:15683 finished externally with red
enamel paint and fixed to wall with brackets complete with internal
charge (Halon Free Gas)

1.20.1 Capacity 4.5 Kg. Each 62 8033.00 498046.00 62.00 8033.00 498046

1.21 Providing and fixing carbon-di-oxide fire extingushers trolley mounted


with all accessories internal discharge tube,high pressure discharge
hose,discharge nozzle, ISI marked as per IS:2878 finished externally
with red enamel paint. (Halon Free Gas)

1.21.1 Capacity 22.5 kg. Each 2 20674.00 41348.00 2.00 20674.00 41348

1.22 Providing and fixing ABC Powder type fire extinguishers consisting of
welded M.S. cylinderical body, squeeze lever discharge valve fitted with
pressure indicating guage internal discharge tube 30 cms long high
pressure discharge hose, discharge nozzle, suspension bracket
conforming to IS:15683 finished externally with red enamel paint and
fixed to wall with brackets complete with internal charge. (Halon Free
Gas)

1.22.1 Capacity 6.0 Kg. Each 62 3636.00 225432.00 62.00 3636.00 225432

1.23 Design, manufacture, supplying, fixing in position, testing and


commissioning of the following front operated cubicle type, front access
2mm thick mild steel sheet, free standing, dust and vermin proof,
switchboard with IP42 protection with hinged and lockable doors
complete with interconnections, tinned copper crimping lugs, bonding to
earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz
system and suitable for a fault level of 25 MVA symmetrical at 415
volts.

1.23.1 MCC for Fire Fighting Pumps at Terrace


INCOMING:
a) One 100 amp. TP +NL M.C.C.B. with rotary handle of breaking
capacity 25 KA
b) One-Volt Meter (0-500 V) with selector switch
c) One Set indicating lamps
BUS BARS OUTGOING
a) 100 Amp TPN BUS BAR (Aluminium).
b) One - 63 Amp.TP +NL M.C.C.B. with rotary handle of breaking
capacity 35KA
c) One Fully Automatic D.O.L Starter suitable for Jockey Pump Motor
15 KW with over load relay, timer push buttons and Auto/Manual
selector switch
d) One panel type Amp. meters one for each motor with ASS. CTS etc.

e) One sets of On/Off - neon indicating lamp.


i) All interconnecting power & control wires/cables suitable size within
the panel and from panel to motors , pressure switches, level
switches, cable Tray, pipes etc. including brass glands termination 10 43638.00 436380.00 43638.00 436380
within fire pump house and earthing as per specifications.
Set 10.00

Total 0.00 4568869.00 1775165.00 0 4568869 1775165


LESS GST 4006022.797 4006022.797
LES CESS 3966359.205 3966359.205
TOTAL AMOUNT OF FIRE FIGHTING (D) 5741524.20 5741524.205 0.00

E EXTERNAL PLUMBING
1.0 External Water Supply System

1.1 Providing and fixing G.I. pipes complete with G.I. fittings including
trenching and refilling etc.
1.1.1 20 mm dia nominal bore Metre 60 283.80 17028.00 60 283.8 17028
1.1.2 25 mm dia nominal bore Metre 160 364.55 58328.00 160 364.55 58328
1.1.3 32 mm dia nominal bore Metre 160 424.70 67952.00 160 424.7 67952
1.1.4 40 mm dia nominal bore Metre 260 483.15 125619.00 260 483.15 125619
1.1.5 50 mm dia nominal bore Metre 310 565.25 175227.50 310 565.25 175227.5
1.1.6 65 mm dia nominal bore Metre 485 716.00 347260.00 485 716 347260
1.1.7 80 mm dia nominal bore Metre 935 866.40 810084.00 935 866.4 810084

1.2 Providing and fixing gun metal gate valve with C.I. wheel of approved
quality (screwed end) :

1.2.1 20 mm dia nominal bore Each 0 460.20 0.00 0 460.2 0


1.2.2 25 mm dia nominal bore Each 33 497.15 16405.95 33 497.15 16405.95
1.2.3 32 mm dia nominal bore Each 10 581.25 5812.50 10 581.25 5812.5
1.2.4 40 mm dia nominal bore Each 6 678.40 4070.40 6 678.4 4070.4
1.2.5 50 mm dia nominal bore Each 5 869.20 4346.00 5 869.2 4346
1.2.6 65 mm dia nominal bore Each 5 1488.10 7440.50 5 1488.1 7440.5
1.2.7 80 mm dia nominal bore Each 8 2217.90 17743.20 8 2217.9 17743.2

1.3 Constructing masonry Chamber 30x30x50 cm inside, in brick work in


cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I.
surface box 100x100 x75 mm (inside) with hinged cover fixed in cement
concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), i/c necessary excavation, foundation
concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40
mm nominal size ) and inside plastering with cement mortar 1:3 (1
cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat
cement complete as per standard design :

1.3.1 With common burnt clay F.P.S.(non modular) bricks of class designation
27 1582.45 42726.15 1582.45 42726.15
7.5 Each 27

1.4 Constructing masonry Chamber 60x60x75 cm inside, in brick work in


cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I.
surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm
deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c
necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand
: 10 graded stone aggregate 40 mm nominal size ) and inside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished
with a floating coat of neat cement complete as per standard design :

1.4.1 With common burnt clay F.P.S.(non modular) bricks of class designation
22 9288.40 204344.80 9288.4 204344.8
7.5 Each 22

1.5 Painting G.I. pipes and fittings with two coats of anti-corrosive
bitumastic paint of approved quality :

1.5.1 20 mm dia nominal bore Metre 60 11.10 666.00 60.00 11.10 666
1.5.2 25 mm dia nominal bore Metre 160 14.15 2264.00 160.00 14.15 2264
1.5.3 32 mm dia nominal bore Metre 160 17.05 2728.00 160.00 17.05 2728
1.5.4 40 mm dia nominal bore Metre 260 19.40 5044.00 260.00 19.40 5044
1.5.5 50 mm dia nominal bore Metre 310 23.35 7238.50 310.00 23.35 7238.5
1.5.6 65 mm dia nominal bore Metre 485 28.95 14040.75 485.00 28.95 14040.75
1.5.7 80 mm dia nominal bore Metre 935 33.60 31416.00 935.00 33.60 31416

1.6 Providing and filling sand of grading zone V or coarser grade, allround
the G.I. pipes in external work :

1.6.1 20 mm dia nominal bore Metre 60 144.55 8673.00 60.00 144.55 8673
1.6.2 25 mm dia nominal bore Metre 160 148.40 23744.00 160.00 148.40 23744
1.6.3 32 mm dia nominal bore Metre 160 152.25 24360.00 160.00 152.25 24360
1.6.4 40 mm dia nominal bore Metre 260 154.15 40079.00 260.00 154.15 40079
1.6.5 50 mm dia nominal bore Metre 310 159.95 49584.50 310.00 159.95 49584.5
1.6.6 65 mm dia nominal bore Metre 485 252.45 122438.25 485.00 252.45 122438.25
1.6.7 80 mm dia nominal bore Metre 935 260.15 243240.25 935.00 260.15 243240.25

1.7 Providing and fixing C.I. double acting air valve of approved quality
with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers
etc if required will be paid separately) :

1.7.1 50 mm dia Each 2 5157.00 10314.00 2.00 5157.00 10314


1.8 Providing and fixing enclosed type water meter (bulk type) conforming
to IS : 2373 and tested by Municipal Board complete with bolts, nuts,
rubber insertions etc. (The tail pieces if required will be paid separately)
:

1.8.1 80 mm dia nominal bore Each 5 3135.52 15677.62 5.00 3135.52 15677.6224

1.9 Providing and fixing C.I. dirt box strainer for bulk type water meter with
nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :

1.9.1 80 mm dia nominal bore Each 5 3593.04 17965.19 5.00 3593.04 17965.1936

1.10 Providing and laying D.I. specials of class K-12 suitable for push-on
jointing as per IS : 9523 :

1.10.1 Up to 600 mm dia Quintal 5 17094.25 85471.25 5 17094.25 85471.25

1.11 Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or


Ductile Iron Pipes including testing of joints and the cost of rubber
gasket :

1.11.1 100 mm dia. Pipe Each 25 91.65 2291.25 25 91.65 2291.25

1.12 Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes
conforming to IS : 8329 :

1.12.1 100 mm dia Ductile Iron Class K-9 pipes Metre 210 1073.50 225435.00 210 1073.5 225435

1.13 Supplying, fixing, testing and commissioning of butterfly


valve of PN 1.6 rating with bronze/gunmetal seat duly ISI
marked complete with nuts, bolts, washers, gaskets
conforming to IS 13095 of following sizes as required

1.13.1 100 mm dia Each 2 5658.87 11317.73 2.00 5658.87 11317.7344

1.14 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,


having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of
joints complete as per direction of Engineer in Charge.
External Work
1.14.1 32 mm nominal outer dia pipes Metre 75 413.70 31027.50 75.00 413.70 31027.5
1.14.2 40 mm nominal outer dia pipes Metre 75 536.75 40256.25 75.00 536.75 40256.25
1.14.3 50 mm nominal outer dia pipes Metre 125 791.65 98956.25 125.00 791.65 98956.25
1.14.4 62.5 mm nominal inner dia pipes Metre 200 1552.30 310460.00 200.00 1552.30 310460
1.14.5 75 mm nominal inner dia pipes Metre 350 1965.85 688047.50 350.00 1965.85 688047.5
1.14.7 100 mm nominal inner dia pipes Metre 130 2779.55 361341.50 130.00 2779.55 361341.5

2.0 External Sewerage & Storm Water Drainage

2.1 Earth work in excavation by mechanical means (Hydraulic excavator) /


manual means in foundation trenches or drains (not exceeding 1.5 m in
width or 10 sqm on plan), including dressing of sides and ramming of
bottoms, lift upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m.

2.1.1 All kinds of soil. Cum 1359 252.30 342875.70 1359 252.3 342875.7

2.2 Excavating trenches of required width for pipes, cables, etc including
excavation for sockets, and dressing of sides, ramming of bottoms, depth
upto 1.5 m, including getting out the excavated soil, and then returning
the soil as required, in layers not exceeding 20 cm in depth, including
consolidating each deposited layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed, within a lead of 50 m :

2.2.1 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Metre 3000 364.20 1092600.00 364.20 1092600
3000.00

2.2.2 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm.
Metre 850 568.60 483310.00 568.60 483310
850.00
2.3 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for
depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over
corresponding basic item for depth upto 1.5 metre).

2.3.1 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
750 462.53 346900.50 462.53 346900.5
Metre 750.00
2.3.2 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm.
400 722.12 288848.80 722.12 288848.8
Metre 400.00

2.4 Filling available excavated earth (excluding rock) in trenches, plinth,


sides of foundations etc. in layers not exceeding 20cm in
340 219.65 74681.00 219.65 74681
depth,consolidating each deposited layer by ramming and watering, lead
up to 50 m and lift upto 1.5 m. Cum 340.00

2.5 Extra for every additional lift of 1.5m or part thereof in:

2.5.1 All kinds of soil (Manhole) Cum 1019 90.40 92117.60 1019.00 90.40 92117.6

2.6 Providing and laying cement concrete Cement Concrete with 4 cm gauge
approved stone grit, coarse sand & cement in the proportion of 8:4:1
155 4470.00 692850.00 4470.00 692850
including supply of all materials, labour, Tools & plants etc. required for
proper completion of the work. Cum 155.00

2.7 Providing, laying and jointing glazed stoneware pipes class SP-1 with
stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine
sand) including testing of joints etc. complete :

2.7.1 150 mm diameter Metre 200 500.20 100040.00 200 500.2 100040
2.7.2 200 mm diameter Metre 1100 794.25 873675.00 1100 794.25 873675
2.7.3 250 mm diameter Metre 600 1173.70 704220.00 600 1173.7 704220

2.8 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :
10 graded stone aggregate 40mm nominal size) all round S.W. pipes
including bed concrete as per standard design.

2.8.1 150 mm diameter Metre 200 999.15 199830.00 200 999.15 199830
2.8.2 200 mm diameter Metre 1100 1164.80 1281280.00 1100 1164.8 1281280
2.8.3 250 mm diameter Metre 600 1346.95 808170.00 600 1346.95 808170

2.9 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :
10 graded stone aggregate 40mm nominal size) up to haunches of
S.W/RCC pipes including bed concrete as per standard design.

2.9.1 250 mm diameter Metre 750 861.15 645862.50 750.00 861.15 645862.5
2.9.2 300 mm diameter Metre 350 993.65 347777.50 350.00 993.65 347777.5

2.10 Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber with water tight C.I. cover with
frame of 300 x300 mm size (inside) the weight of cover to be not less
than 4.50 kg and frame to be not less than 2.70 kg as per standard design
:

2.10.1 180x150 mm size P type with sewer bricks Each 75 2413.65 181023.75 75 2413.65 181023.75

2.11 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes
with collars jointed with stiff mixture of cement mortar in the proportion
of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :

2.11.1 250 mm dia. R.C.C. pipe Metre 750 754.45 565837.50 750.00 754.45 565837.5
2.11.2 300 mm dia. R.C.C. pipe Metre 350 863.65 302277.50 350.00 863.65 302277.5
2.11.3 450 mm dia. R.C.C. pipe Metre 400 1392.70 557080.00 400.00 1392.70 557080
2.11.4 500 mm dia. R.C.C. pipe Metre 200 1656.95 331390.00 200.00 1656.95 331390
2.11.5 600 mm dia. R.C.C. pipe Metre 250 1948.35 487087.50 250.00 1948.35 487087.5
2.12 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4
coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5
coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside
plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse
sand) finished with floating coat of neat cement and making making
channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) finished with a floating coat of neat
cement complete as per standard design :

2.12.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame
(light duty) 455x610 mm internal dimensions, total weight of cover and
frame to be not less than 38 kg (weight of cover 23 kg and weight of
frame 15 kg) :

2.12.1.1 With Sewer bricks conforming IS : 4885 Each 85 10915.65 927830.25 85 10915.65 927830.25

2.13 Extra for depth for manholes :

2.13.1 Size 90x80 cm


2.13.1.1 With Sewer bricks conforming to IS : 4885 Metre 28 7533.80 210946.40 28 7533.8 210946.4

2.14 Constructing brick masonary circular type manhole 0.91m internal dia at
bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse
sand) in side cement plaster 12 mm thick with cement mortar 1:3 (1
cement : 3 coarse sand) finished with a floating coat of neat cement,
foundation concrete 1 :3:6 mix (1 cement : 3 coarse sand : 6 graded
40mm nominal size), and making necessary channel in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm
nominal size) finished with a floating coat of neat cement all complete as
per standard design:

2.14.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade
designation) 560mm internal diameter confirming to I.S. 12592, total
weight of cover and frame to be not less than 182 kg., fixed in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) including centering shuttering all complete.
(Excavation, foot rests and 12 mm thick cement plaster at the external
surface shall be paid for separately) :

2.14.1.1 With common burnt clay F.P.S. (non modular) bricks of class
45 11038.10 496714.50 11038.10 496714.5
designation 7.5 Each 45.00
2.14.1.2 With Sewer bricks conforming IS : 4885 Each 25 11033.75 275843.75 25.00 11033.75 275843.75

2.15 Extra depth for circular type manhole 0.91m internal dia (at bottom) with
beyond 0.91m to 1.67m.

2.15.1 With common burnt clay F.P.S. (non modular) bricks of class
17 6448.40 109622.80 6448.40 109622.8
designation 7.5 Metre 17.00
2.15.1.2 With Sewer bricks conforming IS : 4885 Metre 10 6474.15 64741.50 10.00 6474.15 64741.5

2.16 Constructing brick masonry circular manhole 1.22m internal dia at


bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse
sand) inside cement plaster 12mm thick with cement mortar 1:3 (1
cement :3 coarse sand) finished with a floating coat of neat cement
foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 40mm nominal size) and making necessary channel in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) finished with a floating coat of neat cement, all
complete as per standard design :

2.16.1 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade
designation) 560mm internal diameter conforming to I.S. 12592, total
weight of cover and frame to be not less than 182kg. fixed in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) including centering, shuttering all complete.
(Excavation, foot rests and 12 mm thick cement plaster at the external
surface shall be paid for separately) :

2.16.1.1 With common burnt clay F.P.S. (non modular) bricks of class
30 21235.65 637069.50 21235.65 637069.5
designation 7.5 Each 30.00
2.16.1.2 With Sewer bricks conforming IS : 4885 Each 30 21254.90 637647.00 30.00 21254.90 637647
2.17 Extra depth for circular type manhole 1.22m internal dia (at bottom)
beyond 1.68 m to 2.29 m :

2.17.1 With common burnt clay F.P.S. (non modular) bricks of class
9 8368.40 75315.60 8368.40 75315.6
designation 7.5 Metre 9.00
2.17.2 With Sewer bricks conforming IS : 4885 Metre 9 8402.00 75618.00 9.00 8402.00 75618

2.18 Constructing brick masonry circular manhole 1.52m internal dia at


bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse
sand) inside cement plaster 12mm thick with cement mortar 1:3 (1
cement :3 coarse sand) finished with a floating coat of neat cement
foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 40mm nominal size) and making necessary channel in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) finished with a floating coat of neat cement, all
complete as per standard design :

2.18.1 2.30 m deep with SFRC Cover and frame (heavy duty HD-20 grade
designation) 560mm internal diameter conforming to I.S. 12592, total
weight of cover and frame to be not less than 182kg. fixed in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) including centering, shuttering all complete.
(Excavation, foot rests and 12 mm thick cement plaster at the external
surface shall be paid for separately) :

2.18.1.1 With common burnt clay F.P.S. (non modular) bricks of class
0 45459.15 0.00 45459.15 0
designation 7.5 Each 0.00
2.18.1.2 With Sewer bricks conforming IS : 4885 Each 20 45531.90 910638.00 20.00 45531.90 910638

2.19 Extra depth for circular type manhole 1.52m internal dia (at bottom)
beyond 2.30m :

2.19.1 With common burnt clay F.P.S. (non modular) bricks of class
0 19514.30 0.00 19514.30 0
designation 7.5 Metre 0.00
2.19.2 With Sewer bricks conforming IS : 4885 Metre 7 19601.35 137209.45 7.00 19601.35 137209.45

2.20 Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS :
1786 having minimum cross section as 23 mmx25mm and over all
minimum length 263 mm and width as 165mm with minimum 112 mm
space between protruded legs having 2 mm tread on top surface by
ribbing or chequering besides necessary and adequate anchoring
projections on tail length on 138 mm as per standard drawing and 1095 463.05 507039.75 463.05 507039.75
suitable to with stand the bend test and chemical resistance test as per
specifications and having manufacture's permanent identification mark to
be visible even after fixing, including fixing in manholes with 30x20x15
cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregate 20 mm nominal size) complete as per design.
Each 1095.00

2.21 Constructing bricks masonry road gully chamber 50x45x60 cm with


bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including
500x450 mm pre-cast R.C.C. horizontal grating with frame complete as
per standard design :

2.21.1 With common burnt clay F.P.S. (non modular) bricks of class
150 5209.10 781365.00 5209.10 781365
designation 7.5 Each 150.00

2.22 Extra for depth beyond 45 cm of brick masonry chamber

2.22.1 For 455x610 mm size

2.22.1.1 With common burnt clay F.P.S. (non modular) bricks of class
15 3979.10 59686.50 3979.10 59686.5
designation 7.5 Metre 15.00

3.0 Rain Water Harvesting System

3.1 Earth work in excavation by mechanical means (Hydraulic excavator) /


manual means in foundation trenches or drains (not exceeding 1.5 m in
width or 10 sqm on plan), including dressing of sides and ramming of
bottoms, lift upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m.
3.1.1 All kinds of soil. Cum 800 252.30 201840.00 800.00 252.30 201840

3.2 Filling available excavated earth (excluding rock) in trenches, plinth,


sides of foundations etc. in layers not exceeding 20cm in depth,
200 219.65 43930.00 219.65 43930
consolidating each deposited layer by ramming and watering, lead up to
50 m and lift upto 1.5 m. Cum 200.00

3.3 Extra for every additional lift of 1.5 m or part thereof in.

3.3.1 All kinds of soil. Cum 900 90.40 81360.00 900.00 90.40 81360

3.4 Providing and laying cement concrete with 4 cm gauge approved stone
grit, coarse sand & cement in the proportion of 8:4:1 including supply of
24 4470.00 107280.00 4470.00 107280
all materials, labour, Tools & plants etc. required for proper completion
of the work. Cum 24.00

3.5 Reinforced cement concrete work in beams, suspended floors, roofs


having slope up to 15° landings, balconies, shelves,chajjas, lintels,
bands, plain window sills, staircases and spiral stair cases up to floor five
level excluding the cost of centering, shuttering, finishing & 25 9763.80 244095.00 9763.80 244095
reinforcement with1:2:4 (1 cement: 2 coarse sand: 4 graded stone
aggregate 20 mm nominal size) Cum 25.00

3.6 Centring and shuttering including stutting, propping etc. and removal of
form for:

3.6.1 Suspended floors, roofs, landings, balconies and acees platform Sqm 90 693.05 62374.50 90.00 693.05 62374.5

3.7 Reinforcement for R.C.C. work including straightening, cutting, bending,


placing in position and binding all complete.
3.7.1 Thermo-Mechanically Treated bars of Grade Fe-500D or More. Kg 3000 83.50 250500.00 3000.00 83.50 250500

3.8 M-150 Brick Work in 1:6 cement and Coarse sand mortar (One cement
& six fine sand of 1.25 F.M.) mortar in foundation and plinth including
109 3750.00 408750.00 3750.00 408750
supply of all materials labour, Tools & plants etc. required for proper
completion of the work. Cum 109.00

3.9 Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS :
1786 having minimum cross section as 23 mmx25mm and over all
minimum length 263 mm and width as 165mm with minimum 112 mm
space between protruded legs having 2 mm tread on top surface by
ribbing or chequering besides necessary and adequate anchoring
projections on tail length on 138 mm as per standard drawing and
suitable to with stand the bend test and chemical resistance test as per 252 463.05 116688.60 463.05 116688.6
specifications and having manufacture's permanent identification mark to
be visible even after fixing, including fixing in manholes with 30x20x15
cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregate 20 mm nominal size) complete as per design.

Each 252.00

3.10 Providing and fixing in position precast RCC manhole cover and frame
of required shape and approved quality.

3.10.1 HD-20 circular shape 560 mm internal diameter. Each 24 1471.50 35316.00 24.00 1471.50 35316

3.11 Boring/drilling bore well of required dia for casing/ strainer pipe, by
suitable method prescribed in IS: 2800 (part I), including collecting
samples from different strata, preparing and submitting strata chart/bore
log, including hire & running charges of all equipments, tools, plants &
machineries required for the job, all complete as per direction of
Engineer –in-charge, upto 90 metre depth below ground level.

3.11.1 All types of soil


3.11.1.1 400 mm dia. Metre 360 717.20 258192.00 360.00 717.20 258192

3.12 Supplying, assembling, lowering and fixing in vertical position in bore


well, unplasticized PVC medium well casing (CM) pipe of required dia,
conforming to IS: 12818, including required hire and labour charges,
fittings & accessories etc. all complete, for all depths, as per direction of
Engineer –in-charge.

3.12.1 200 mm nominal size dia. Metre 30 1066.05 31981.50 30.00 1066.05 31981.5
3.13 Supplying, assembling, lowering and fixing in vertical position in bore
well unplasticized PVC medium well screen (RMS) pipes with ribs,
conforming to IS: 12818, including hire & labour charges, fittings &
accessories etc. all complete, for all depths, as per direction of Engineer-
in-charge.

3.13.1 200 mm nominal size dia. Metre 330 1135.80 374814.00 330.00 1135.80 374814

3.14 Supplying, filling, spreading & levelling stone boulders of size range 5
cm to 20 cm, in recharge pit, in the required thickness, for all leads & 39 1326.55 51735.45 1326.55 51735.45
lifts, all complete as per direction of Engineer-in-charge. Cum 39.00

3.15 Supplying, filling, spreading & levelling gravels of size range 5 mm to


10 mm, in the recharge pit, over the existing layer of boulders, in
39 1326.55 51735.45 1326.55 51735.45
required thickness, for all leads & lifts, all complete as per direction of
Engineer-in-charge. Cum 39.00

3.16 Supplying, filling, spreading & levelling coarse sand of size range 1.5
mm to 2 mm in recharge pit, in required thickness over gravel layer, for
39 1326.55 51735.45 1326.55 51735.45
all leads & lifts, all complete as per direction of Engineer –in-charge.
Cum 39.00

3.17 Gravel packing in tubewell construction in accordance with IS: 4097,


including providing gravel fine/ medium/ coarse, in required grading &
36 1497.70 53917.20 1497.70 53917.2
sizes as per actual requirement, all complete as per direction of Engineer-
in-charge. Cum 36.00

3.18 Development of tube well in accordance with IS : 2800 (part I) and IS:
11189, to establish maximum rate of usable water yield without sand
content (beyond permissible limit), with required capacity air
compressor, running the compressor for required time till well is fully
developed, measuring yield of well by "V" notch method or any other
approved method, measuring static level & draw down etc. by step draw 120 857.60 102912.00 857.60 102912
down method, collecting water samples & getting tested in approved
laboratory, i/c disinfection of tubewell, all complete, including hire &
labour charges of air compressor, tools & accessories etc., all as per
requirement and direction of Engineer-in-charge.
Hours 120.00

3.19 Providing and fixing suitable size threaded mild steel cap or spot welded
plate to the top of bore well housing/ casing pipe, removable as per
requirement, all complete for borewell of:

3.19.1 200 mm dia Each 6 280.95 1685.70 6.00 280.95 1685.7

3.20 Providing and fixing M.S. clamp of required dia to the top of casing/
housing pipe of tubewell as per IS: 2800 (part I), including necessary
bolts & nuts of required size complete.

3.20.1 200 mm clamp. Each 6 1691.15 10146.90 6.00 1691.15 10146.9

4.0 Water Supply, Drainage Pumps & Water Treatment Equipments

4.1 Supply, installation, testing & commissioning of vertical inline


multistage pumping set with Stainless steel-304 body, Stainless steel-304
impeller, Stainless steel-304 casing, Stainless steel-316 shaft and C.I.
base & head with mechanical seal, connected to a TEFC induction
motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply
with 150 mm dia pressure gauge with gunmetal isolation cock, vibration
eliminating pads under foundations, 80x40 mm I section base plate
bolted to cement concrete foundations complete including CC foundation
of suitable size with angle iron lining.Vendor to submit performance
curves and technical catalogue of the proposed model for review and
information.

4.1.1
Filter Feed Pump (Domestic Water) in Water Supply Pump Room
Set of Two Pumps (1 Working + 1 Standby)
Capacity 3.0 LPS
Head 30 M.
HP 2.0 HP Approx. Set 1 179684.00 179684.00 1.00 179684.00 179684

4.1.2 Raw Water Pumps from UGT to STP .


Set of Two Pumps (1 Working+ 1 Standby)
Capacity 3.5 LPS
Head 25-30 M.
HP 3.0 HP Approx. Set 1 195086.00 195086.00 1.00 195086.00 195086

4.2 Supply, installing, testing and commissioning of submersible dewatering


single stage single entry pumps with C.I.body and C.I. two vane
enclosed type impeller, SS-304 shaft connected to TEFC submersible
motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with
mechanical seal, pump connector unit with rubber diaphragm and bend,
vertical discharge pipe, guide pipe and chain in built level controller,
sequence running controller, arrangement for both pumps running
together in case of emenegency, audible hooter for failure or flooding,
dry running Protection complete in all respects.

(Pumps shall be installed in a set of two pumps One working and


One standby)

4.2.1 Pump Room Drainage Pumps


(Pumps to be suitable to handle solids upto 15 mm size)
Capacity - 4.5 LPS (Each)
Head - 15 M
H.P. - 1.5 HP Approx. Set 2 148881.00 297762.00 2.00 148881.00 297762

4.3 Providing, installing, testing and commissining of variable speed (VSPS)


hydropneumatic system mounted on a common base plate under cement
concrete foundation with angle iron lining comprising of vertical
centrifugal pumping set with Stainless steel-304 body, Stainless steel-
304 impeller, Stainless steel-304 casing, Stainless steel-316 shaft and
mechanical seal, shaft directly coupled to a TEFC induction motor
suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm
dia pressure gauge with gunmetal isolation cock, vibration eliminating
pads under foundation, one No. microprocessor based controller,
dedicated variable frequency drive for each pump, one No.remote
sensors, pressure transducers, sequence running cotroller, dry running
Protection, motor control centre, necessary power and control cabling
from MCC to pumps including required rating of MCB, one No. 100 litre
capacity M.S diaphragam tank with interchangeable butyl rubber
membrane or as per manufacturer calculation,complete in all respe
suitable large are surface be means of fins t

including stainless steel grade 316 pipe suction and delivery headers and
isolation/ control valves( ball valves/butterfly valves/ Non return valves/
vibration eliminators etc as required) , power box, equipped with fuses/
isolators/circuit breakers as required.

4.3.1 Hydropneumatic System for Domestic Water Supply in Water


Supply Pump Room
Set of Two Pumps (1 Working + 1 Standby)
Capacity 4.0 LPS
Head 50 M.
HP 5.0 HP Approx. Set 1 385037.00 385037.00 1.00 385037.00 385037

4.3.2 Hydropneumatic System for Flushing Water Supply in STP Pump


Room
Set of Two Pumps (1 Working + 1 Standby)
Capacity 3.0 LPS
Head 50 M.
HP 3.0 HP Approx. Set 1 359368.00 359368.00 1.00 359368.00 359368

4.3.3 Hydropneumatic System for Irrigation Water Supply at STP Pump


Room
Set of Two Pumps (1 Working + 1 Standby)
Capacity 5.0 LPS
Head 40-45 M.
HP 5.0 HP Approx. Set 1 462045.00 462045.00 1.00 462045.00 462045

4.4 Supply Installation,Testing & Commissioning of vertical self supporting


Filter fabricated from MS sheet as per IS: 2825, (minimum thickness of
shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI
class 'C' face piping, CI butterfly valves and all accessories , with initial
charge of filter media including anthracite, painting inside with epoxy
paint and outside with two coat of red oxide primer and two or more coat
of synthetic enamel paint, testing and commissioning complete
including CC foundation of suitable size.

4.4.1 Dual Media Filter For Domestic Water Supply


Capacity- 10800 LPH
Filtration rate- 14000 LPH/Sqm.
Filter dia approx. - 1000 MM
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm Each 1 164283.00 164283.00 1.00 164283.00 164283

4.4.2 Activated Carbon Filter For Domestic Water Supply


Capacity- 10800 LPH
Filtration rate- 14000 LPH/Sqm.
Filter dia approx. - 1000 MM
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm Each 1 179684.00 179684.00 1.00 179684.00 179684

4.5 Supply Installation,Testing & Commissioning of metering pump type


chemical doser with 200 lits. HDPE chemical grade solution
tank,injection fitting assembly,suction and delivery hose upto the point
of injection, capacity 0-12 lph, complete in all respects.

4.5.1 Chlorination of Domestic Water Each 1 28236.00 28236.00 1.00 28236.00 28236

4.6 Design, manufacture, supplying, fixing in position, testing and


commissioning of the following front operated cubicle type, front access
2mm thick mild steel sheet, free standing, dust and vermin proof,
switchboard with IP42 protection with hinged and lockable doors
complete with interconnections, tinned copper crimping lugs, bonding to
earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz
system and suitable for a fault level of 25 MVA symmetrical at 415
volts.

All switchboards shall have provision for entry of cables from the top or
bottom as required.
All live accessible parts shall be shrouded and all equipment shall be
finger touch proof. The busbars insulation shall be with heat shrinkable
sleeves. SMC/DMC shrouds and busbar supports shall be used.
Padlocking facility shall be provided on all outgoing feeders doors and
switch handles shall be lockable in OFF position.

4.6.1 Electric Panel For Water Supply Pumps at Water Supply Pump
Room

INCOMING
1 No. 150 amps TP + NL MCCB with the following accessories:
1 No. square flush mounting 0-500 volts scaled voltmeter with three way
and OFF switch.
Three phase indicating lights.
Electrolytic high conductivity three phase and neutral tinned alluminium
bus bar rated at 200 amps having a current density of 1 amp per Sqmm
suitable to with stand symmetrical fault level of 25 MVA at 415 volts.
The neutral bus bar is to be of 100% capacity.

OUTGOING UNITS

6 Nos 25 Amp. TPN MCB of breaking capacity 10KA


1 No. TPN MCB of 63 A with 10 KA service breaking capacity for
domestic water hydropneumatic pumps. (Only connection to inbuilt
panel of domestic water hydropneumatic system)
6 Nos. fully automatic DOL starters with push buttons and ON/OFF
indicating lights and overload relays for 2.0 to 5.0 HP pumps.

6 Nos. selector switch for selecting mode of operation i.e.


auto/manual/off.
6 Nos.cyclic relay for automatic duty changeover of pumps.
6 No. single phase preventors.
6 Nos. square flush mounting 0-30 amps scaled ammeters with three way
and OFF selector switch.
Space for 4 Nos. Level Controllers.
Switchgear shall be suitable for the HP of various motors.
2 No.25 Amp. TPN MCB Spare.
The motor control panel shall be prewired with colour coded wires with
1 179684.00 179684.00 179684.00 179684
identification labels complete in all respects as required. Set 1.00

4.7 Supplying, installing, testing and commissioning controllers with low


voltage relays, stainless steel probes and PVC shroud wiring from tank
top to probes.

4.7.1 For Water Supply Pump:


To start pump when water level is low in Domestic Water U.G. tank and
shut off pump when Domestic Water U.G. tank is full. Also to stop
5 6674.00 33370.00 6674.00 33370
when water level is low in raw water underground tank.
Each 5.00

4.7.2 For Sump Pumps:


To start pump when water level is high in sump and shut off pump when
sump is empty. Both pumps are start when sump is over flowing. 2 6674.00 13348.00 6674.00 13348
Each 2.00

4.8 Providing, laying, testing & commissioning of 'B' class heavy duty G.I.
pipe conforming to IS 1239 including welding, fittings like elbows, tees,
flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the
wall/ceiling with suitable clamp/support frame and painting with two or
more coats of synthetic enamel paint of required shade complete as
required :

4.8.1 50 mm dia Metre 19 859.00 16321.00 19.00 859.00 16321


4.8.2 65 mm dia Metre 25 1076.00 26900.00 25.00 1076.00 26900
4.8.3 80 mm dia Metre 30 1252.00 37560.00 30.00 1252.00 37560
4.8.4 100 mm dia Metre 29 1627.00 47183.00 29.00 1627.00 47183

4.9 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6


rating with bronze/gunmetal seat duly ISI marked complete with nuts,
bolts, washers, gaskets conforming to IS 13095 of following sizes as
required :

4.9.1 50 mm dia Each 12 3671.00 44052.00 12.00 3671.00 44052


4.9.2 65 mm dia Each 6 4149.00 24894.00 6.00 4149.00 24894
4.9.3 80 mm dia Each 8 4842.00 38736.00 8.00 4842.00 38736
4.9.4 100 mm dia Each 4 6554.00 26216.00 4.00 6554.00 26216

4.10 Providing, installation, testing and commissioning of non-return valve of


following sizes confirming to IS: 5312 complete with rubber gasket, GI
bolts, nuts, washers etc.as required :

4.10.1 50 mm dia Each 4 5646.00 22584.00 4.00 5646.00 22584


4.10.2 65 mm dia Each 4 6274.00 25096.00 4.00 6274.00 25096
4.10.3 80 mm dia Each 2 7539.00 15078.00 2.00 7539.00 15078

45.11 Providing and fixing resilient rubber neoprene lined style arch vibration
eliminators suitable for raw water upto 45 deg.C. Temperature
working pressure upto 25 Kg/Sqcm.

4.11.1 50 mm dia Each 8 3287.00 26296.00 8.00 3287.00 26296


4.11.2 65 mm dia Each 4 3932.00 15728.00 4.00 3932.00 15728
4.11.3 80 mm dia Each 2 4248.00 8496.00 2.00 4248.00 8496

4.12 Providing and fixing heavy duty armoured cables 1.1 KVA grade
including necessary support clamps at ceiling level and connection lugs
complete in all respects.

4.12.1 Power cable Copper 3 core 10 sq.mm Metre 35 302.00 10570.00 35.00 302.00 10570
4.12.2 Power cable 3 core 6 sqmm Metre 50 188.00 9400.00 50.00 188.00 9400
4.12.3 Power cable Copper 3 core 4 sq.mm Metre 50 137.00 6850.00 50.00 137.00 6850
4.12.4 Control cable copper 2 core 1.5 sq.mm Metre 128 62.00 7936.00 128.00 62.00 7936

4.13 Providing, installation, testing and commissioning of stainless steel Y-


strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet
with 3 mm dia holes with stainless steel flange.

4.13.1 80 mm dia. Each 4 4573.00 18292.00 4.00 4573.00 18292


4.13.2 100 mm dia. Each 2 6450.00 12900.00 2.00 6450.00 12900

1208880.00 22773409.90 2562863.00 1208880 22773409.9 2562863


19967917.49 19967917.49
19770215.34 19770215.34
TOTAL AMOUNT OF EXTERNAL PLUMBING ( E) 23541958.34 23541958.34 0.00

F Sewage Treatment Plant (MBR Technology)

Design, Supplying, installing, testing & commissioning of fully


automatic Sewage Treatment Plant of 150 KLD based on MBR
Technology for the following duty:
Nature of effluent - Domestic Sewage from toilet, kitchen waste water,
domestic Laundry waste (if any) shall be discharged into the STP.
Design to take consideration of same.

INLET EFFLUENT CHARACTERSTICS


pH - 6.5 – 8.5
BOD - 500 Mg/L
S. Solids - 250 Mg/L
COD - 750 Mg/L
Oil & Grease - 50 Mg / L (after oil and grease trap)

DISCHARGE EFFLUENT CHARACTERSTICS AFTER


TREATMENT
pH - 6.0 – 8.0
BOD - Less than 5 Mg/L
S. Solids - Less than 50 Mg/L
COD - Less than 20 Mg/L
Oil & Grease - below detectable level
Turbidity - Less than 1 NTU
E coli Removal - below detectable level

6.1 STP Cap 150 KLD Electrical & Mechanical Works

Design, supplying, installing, testing & commissioning of 150 KLD


Sewage Treatment Plant for Domestic Waste/Kitchen (excluding all
Civil & construction work) for the following duty:-

Supply, installation, testing & commissioning of 2 Nos. Stainless Steel-


316 Perforated Corrugated Screen of size 800mm x 800mm fabricated
through 5mm thick plate having holes of 8 mm at a distance of 10 mm
with suitable lifting arrangement. This is to slide in the fixed ss channels
fixed on the side walls. Set-1

Supply and installation of MS Class 'C' with hot dip galvanized puddle
flange 25 to 150 mm dia. in accordance to relevant IS pipe standards as
required to be provided (in the structural slab & wall) of various
diameter. Puddle flanges shall be provided for all the structural
component of the STP/ETP. Lot-1

Supply and fixing of mechanical punched hole fine screen for 2-3 mm
size complete as required MOC- SS 304. Set-1

Supply and fixing of meachenical belt type oil skimmer basin MS


housing with 500 liter HDPE tank for 1/2 Lph flow rate capacity
complete in all respect. Set-1

Supply and fixing of electronic type level indicator and controller for
automatic operation of the system with high/low level alarm complete
with auxillary NO/NC contacts for each tank. Lot-1

Supply and fixing of sight tube (of 3.5 to 4.5 m length) with isolation
valve at top/bottom, demarcation on tube & for making the installation
complete. Lot-1

Supplying and fixing of fully submersible, centrifugal non-clog sewage


handling type pump for raw sewage transfer from equalization tank to
Anoxic Tanks. The pump shall have CI casing, CI impeller and SS 304
shaft, TEFC induction motor suitable for 415+10%Volt, 3 Phase, 50
Cycles AC Power supply, Mechanical seal, Pump connector unit with
rubber diaphragm and bend including pressure gauge, lifting
arrangement/lifting device of pull chain/guide rail for the pump,
sequence running controller, dry running protection, level controller
complete with probs complete in all respect including delivery header &
delivery pipe (interconnecting piping) with GI 'C' class pipe of required
dia, isolation valves, NRV & vibration eliminators on delivery side of
Pumps. Set-1

Equlisation Transfer Pump


Capacity/Flow rate - 10 m3/h
Pumping Head - 8-10 Mtr
Solid Handling: 45 mm
Set of 2 Nos. Pumps (1 Working +1 Standby)
Supply and fixing of 2 Nos. twin type rotary air blowers (1W + 1S)
capable of delivering 200 cum/hr of free air at 0.5 kg/cm2 for Aeration
Tank and Equlisation tank. driven through “V” belt or directly coupled
through flexible coupling to a TEFCmotor of suitable HP Suitable for
415 ± 10% volts, 3 phase, 50 cycles A/C supply.1225 RPM with all
accessories complete in all respects.Set-1

Supply and fixing Disc type, EPDM membrane based, non clog type air
dispersion system capable of handling 3-5 cfm of air with oxygen
transfer efficiency of 3-4% per/meter water depth. Air dispersion grid
shall be assembled in modular form so that they can be replaced /
repaired easily from plat form at the top. (Imported fine bubble
membrane diffusers for equalisation tank, aeration tank & sludge holding
tank) Lot-1

Supply and fixing Tube type, silicon membrane based, non clog type air
dispersion system capable of handling 3-5 cfm of air with oxygen
transfer efficiency of 3-4% per/meter water depth. Air dispersion grid
shall be assembled in modular form so that they can be replaced /
repaired easily from plat form at the top. (Imported fine bubble
membrane diffusers for MBR tank) Lot-1

Note : Air dispersion system shall be provided for Equalisation tank,


Aeration tank, MBR tank and Sludge holding tank.

Providing, Laying, testing & Commissioning of "C" Class Heavy duty


MS Pipe 32 to 150 mm dia as required conforming to IS: 1239 including
fittings like elbows, tees, flanges, nut bolts, gaskets with suitabke clamps
& painting with Two or more coats of synthetic enamel paint of required
shade over a coat of steel primer complete as required. For
Interconnecting Lines and Air Lines. Lot-1

Providing, Laying, testing & Commissioning of stainless steel grade-304


schedule-10, 25 to 80 mm dia. as required including fittings like elbows,
tees, flanges, nut bolts, gaskets with suitable clamps.Lot-1

Providing & fixing butterfly valve tested to a pressure not less than 15
Kg/Sq.cm. 50 to 150 mm dia as required Including rubber gasket, 2 nos.
table-E flanges, nuts, bolts, washers & painting complete as required.Lot-
1

Providing & fixing dual plate CI wafer type check valve 50 to 150 mm
dia. as required tested to a pressure of 10 Kg/sqcm. Including rubber
gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting
complete as required. Lot-1

Providing and fixing forged brass ball valve with SS ball suitable for
test pressure of not less than 15 kg / sq.cm of the 25 to 40 mm dia. Lot-
1:

Supply, installation, testing & commissioning of MBR modules of


hollow fibre reinforced filteration membranes with SS – 316 skid for
housing the membrains & air grid for sccouring the sludge, permeate S.S
piping etc. complete in all respect as required.

Membrane Tank of RCC - Membrane Accessories, Valve, Instrument,


Permeate Collection and air distribution header piping etc. Backwash
tank of FRP, Permeate pump with VFD : CI 1w+1s capacity : 10 m3/hr,
backwash pump with VFD : CI 1w+1s capacity : 15 m3/hr , Membrane
blower without acoustic hood MOC : CI 1w +1S capacity : 300 Nm3/hr,
Type : Twin lobe type, Chemical dosing system : 1W, * Membrane shall
have max pore size of 0.04 micron. Membrane shall have 2 year full
replacement cliff warrenty. Lot-1
Supply and fixing of ultravoilet dis-infection unit. The unit shall have
over 99.9 % bacterial reduction from inlet to outlet. The dis-infection
chamber shall be constructed of SS 316L on all welted parts. The UV
lamp shall be of low pressure mercury vapour type with hard glass
enclosure, the sockets shall be water tight & vibration resistant. The
lamp life shall be rated for 6000 hours. The unit shall be complete with
temperature safety control, lamp out alert circuit & UV radiometer with 4
– 20 mA output as of manufacturers recomendation in all respects. The
UV unit shall have with reactor, cabinet housing, cabinet cooling,
treatment chamber, electrical panel, temperature safety control, lampout
alert, UV radiometer along with UV monitoring system and UV
monitoring readout panel. The UV Dosage should be > 60,000 uW – Sec
/ sq.cm. The lamps should be selected based upon the flow requirement
of respective unit. as recomended by manufacturer complete in all
respects.

Flow Rate :5 M3/hr Set-1

Supply and fixing of horizontal, centrifugal Sludge disposal pump for the
disposal of sludge from tube settler to sludge holding tank. The pumps
shall have CI casing, CI/bronze Impeller & SS 304 shaft & sleeve with
mechanical rotary shaft seal connected by a flexible tier type coupling to
TEFC induction motor suitable for 415+10% Volts, 3 Phase, 50Hz, AC
Power Supply mounted on a common channel base-plate with coupling
guard, 150 mm dia pressure gauge with GM isolation cock, suitable
vibration eliminator pads under foundation of approved design, dry
running protection including all necessary piping, valves, level controller
complete with probs and other accessories complete as required. Set-1

Sludge Recycling Pump


Capacity/Flow rate - 4 M3/h
Pumping Head - 8-10 Mtr
(Solid handling size for this pump shal be 7-10 mm)
Set of 2 Nos. Pumps (1 Working +1 Standby)

Supply and fixing of basket/Screw/Solid bowl type centrifuge with top


discharge of suitable for 3 batches in a day with interconnecting piping,
lifting arrangement, pump and poly dosing system. The basket shall be in
SS 304 construction complete in all respects. Set-1

Supply and fixing of Centrifuge Feed pump of suitable capacity with CI


body, SS-Impeller and Shift complete (Screw Type) - 2 Nos.
(1working+1standby) Set-1

Supply and fixing of following instrument for the auto operation of


System and saftey of MBR modules.

2 Nos. Electro-magnetic flow meter cum totalizer at the sewage inlet and
outlet of membrane suction pump of suitable size.

1 No. pH Meter at membrane suction pump outlet for measurement of


pH.

1 Set Diffrential pressure switch transmittor and for pressure alarm high
and low, flow switch for flow alarm high and low.

1 Set Online rotameter for checking the air flow to the MBR module.

1 Set Air Rotameter for Biological Air supply and Air scouring

6.1.1 STP As Describe Above Set 1 4620447.00 4620447 1 4620447 4620447

6.2 ELECTRICAL WORKS

Supply and fixing of the following front operated cubicle type


compartmentalition, front access totally enclosed sheet steel clad, free
standing, dust and vermin proof, switchboards with IP 42 protection
with hinged, gasketed and lockable doors including interconnections,
copper crimping lugs, brass glands, bonding to earth and painting,
suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system, and with 25
kA rupturing capacity at 415 volts complete as per specifications, as
required and as below.
All switchboards shall have provision for entry of cables from the top or
bottom as required.

All live accessible parts shall be shrouded and all equipment shall be
finger touch proof. The busbars insulation shall be with heat shrinkable
sleeves. SMC/DMC shrouds and busbar supports shall be used.
Padlocking facility shall be provided on all outgoing feeders doors and
switch handles shall be locakble in OFF position.

INCOMING

1 No. 250 Amp 25 kA TPN MCCB with Thermal over load and magnetic
short circuit release site settable

INDICATING PANEL

The incomers shall have the following indicating panel


Square flush mounting 0-150 amp scaled ammeter with 3 way and OFF
selector switch
3 nos. Cast resin current transformers of 150/5 ratio Class 1.0, 15 VA
burden for metering
Three phase indicating lamps
Square flush mounting voltmeter scaled 0-500 volt with 3 way and OFF
selector switch

BUSBAR

Electrolytic high conductivity aluminium three phase and neutral busbars


rated at 300 amps having a maximum current density of 1 amp per sq
mm suitable to with stand symmetrical fault level of 25 kA at 415 volts
for 1 second. The neutral busbar is to be of 50% capacity.

OUTGOING UNITS

2 Nos 63 Amp. TPN MCCB of breaking capacity 10KA (For 7.5 KW Air
Blowers for EQT, AT & SHT)
2 Nos. fully automatic DOL starters with push buttons and ON/OFF
indicating lights and overload relays for 7.5 KW Air Blower .

2 Nos. selector switch for selecting mode of operation i.e.


auto/manual/off.
2 Nos. single phase preventors.
2 Nos. square flush mounting 0-30 amps scaled ammeters with three way
and OFF selector switch.
Space for 1 no Level Controllers.

2 Nos 63 Amp. TPN MCCB of breaking capacity 10KA (For 10 KW Air


Blowers for MBR Tank)
2 Nos. fully automatic Star Delta starters with push buttons and ON/OFF
indicating lights and overload relays for 10 KW Air Blower .

2 Nos. selector switch for selecting mode of operation i.e.


auto/manual/off.
2 Nos. single phase preventors.
2 Nos. square flush mounting 0-30 amps scaled ammeters with three way
and OFF selector switch.
Space for 1 no Level Controllers.

2 Nos 32 Amp. TPN MCB of breaking capacity 10KA (For 3 Kw,


centrifuge feed pumps)
2 Nos. fully automatic DOL starters with push buttons and ON/OFF
indicating lights and overload relays for 2.0 KW pump .
2 Nos. selector switch for selecting mode of operation i.e.
auto/manual/off.
2 Nos. single phase preventors.
2 Nos. square flush mounting 0-30 amps scaled ammeters with three way
and OFF selector switch.
Space for 1 no Level Controllers.

10 Nos 25 Amp. TPN MCB of breaking capacity 10KA (For 2 Kw, Eq.
transfer, MBR suction, sludge feed, MBR permeate, MBR backwash
pumps)
10 Nos. fully automatic DOL starters with push buttons and ON/OFF
indicating lights and overload relays for 2.0 KW pump .
10 Nos. selector switch for selecting mode of operation i.e.
auto/manual/off.
10 Nos. single phase preventors.
10 Nos. square flush mounting 0-30 amps scaled ammeters with three
way and OFF selector switch.
Space for 5 nos Level Controllers.

2 Nos 16 Amp. TPN MCB of breaking capacity 10KA (For 0.5 Kw,
Hydro dosing solution pump and citric solution dosing pump)
2 Nos. fully automatic DOL starters with push buttons and ON/OFF
indicating lights and overload relays for 0.5 KW pump .
2 Nos. selector switch for selecting mode of operation i.e.
auto/manual/off.
2 Nos. single phase preventors.
2 Nos. square flush mounting 0-30 amps scaled ammeters with three way
and OFF selector switch.

2 No. 63 Amp. TPN MCCB Spare.


2 No. 40 Amp. TPN MCB Spare.
2 Nos. 32 Amp. TPN MCB Spare.

The Switchboard shall be complete with all interconnections, risers,


internal wiring, labels etc complete as required

Supplying & laying of following 1100 volt grade XLPE insulated PVC
sheathed copper conductor armoured cables required size & length as
per specification in existing trenches, cable trays, ducts, clamped to wall
with suitable clamps including providing and fixing of all fixing
accessories, connecting, testing and commissioning. 1 Lot

6.2.1 Electrical Work as Descrive Above Set 1 282361.00 282361 1 282361 282361

TOTAL AMOUNT OF STP (MEP) (F) 4902808 4902808 0

G STP CIVIL
Earth work in surface excavation not exceeding 30 cm in depth but
exceeding 1.5 m in width as well as 10 sqm on plan including getting out
and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed
by Engineer-in- Charge:
All kinds of soil 100Sq
8.07 92.55 746.94 8.07 92.55 746.943285
m
Earth work in excavation by mechanical means (Hydraulic excavator) /
manual means in foundation trenches or drains (not exceeding 1.5 m in
width or 10 sqm on plan), including dressing of sides and ramming of
bottoms, lift upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m.

All kinds of soil Cum 4035.35 252.30 1018118.81 4035.35 252.3 1018118.805
Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
Cum 1383.32 219.65 303845.69 1383.32 219.65 303845.6889
consolidating each deposited layer by ramming and watering, lead up to
50 m and lift upto 1.5 m.
Supplying chemical emulsion in sealed containers including delivery as
specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% litre 161.41 200.85 32420.00 161.41 200.85 32420.0019

Diluting and injecting chemical emulsion for POST-


CONSTRUCTIONAL anti-termite treatment (excluding the cost of
chemical emulsion) :Treatment of soil under existing floors using
chemical emulsion @ one litre per hole, 300 mm apart including drilling Sqm 807.07 227.05 183245.24 807.07 227.05 183245.2435
12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement :
2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane
E.C. 20% with 1% concentration
Total
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40
Cum 58.42 5789.60 338228.43 58.42 5789.6 338228.432
mm nominal size)
Total
REINFORCED CEMENT CONCRETE WORK
Centering and shuttering including strutting, propping etc. and removal
of form for:
Foundations, footings, bases of columns etc. for mass concrete. Sqm 69.90 284.85 19911.87 69.90 284.85 19911.86955
Wall (any thikness) including attached pilasters, butteresses, plinth and
Sqm 2363.42 609.30 1440029.37 2363.42 609.3 1440029.369
string courses etc.
Suspended floors, roofs, landings, balconies, and access platform. Sqm 606.89 693.05 420605.11 606.89 693.05 420605.1145
Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 0.00 301.00 0.00 301
Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 0.00 390.00 0.00 390
Steel reinforcement for R.C.C. work including straightening,
cutting,bending, placing in position and binding all complete above
plinth level.
Steel reinforcement for R.C.C. work including straightening,
cutting,bending, placing in position and binding all complete upto plinth
kg 137559.76 83.50 11486239.63 137559.76 83.5 11486239.63
level.Thermo-Mechanically Treated bars of grade Fe-500D or more.

Providing and laying in position machine batched and machine mixed


design mix M-25 grade cement concrete for reinforced cement concrete
work, using cement content as per approved design mix, including
pumping of concrete to site of laying but excluding the cost of centering,
shuttering, finishing and including retard setting of concrete, improve
workability without impairing strength andadmixtures in recommended
proportions as per IS: 9103 to accelerate,reinforcement,durability as per
direction of Engineer-incharge. Note:- Cement content considered in this
item is @ 330 kg/ cum. Excess or less cement used as per design mix is
payable or recoverable separately.

All work upto plinth level Cum 1144.77 8398.65 9614512.48 1144.77 8398.65 9614512.482
All work from plinth level upto floor V level Cum 1.56 9802.20 15315.94 1.56 9802.2 15315.9375
Total
Brick work
Providing and laying autoclaved aerated cement blocks masonry with
150mm/230mm/300 mm thick AAC blocks in super structure above
plinth level up to floor V level with RCC band at sill level and lintel level
with approved block laying polymer modified adhesive mortar all Cum 9.66 6636.95 64112.94 9.66 6636.95 64112.937
complete as per direction of Engineer-in-Charge. (The payment of RCC
band and reinforcement shall be made for seperately).

Total
WOOD AND P. V. C. WORK
Providing and fixing flush door shutters conforming to IS : 2202 (Part-I)
non-decorative type.core of block board construction with frame of 1st
class tiard wood and well mathched commercial 3 ply veneering wiih
vertical grains or cross bands and face veneers on both faces of shutters.

30mm thick including ISI marked Stainless Steel butt hinges with
Sqm 2.10 1819.80 3821.58 2.10 1819.8 3821.58
necessary screws
Providing and fixing aluminium extruded section body tubular type
universal hydraulic door closer (having brand logo with ISI, IS : 3564,
embossed on the body, door weight upto 36 kg to 80 kg and door width Each 1.00 851.60 851.60 1.00 851.6 851.6
from 701 mm to 1000 mm), with double speed adjustment with
necessary accessories and screws etc. complete.
Providing and fixing factory made s›ngIe extruded WPC (Wood Pol
ymer Composite) solid door/window/Ceasetory window & other
Frame/Chowkhat comprising of virgin PVC polymer of K value 58-60 (
Suspension Grade), calcium carbonate and natural fibers (wood powder/
rice husk/whent husk) and non toxic additives (maximum oxicily index
of 12 for 100 gms) fabricated wilh miter joints after applying PVC
solvent cement and screwed wilh full body threaded star headed SS
screws having minimum frame density of 750 kg/ cum screw withdraw
strength Of 2200 N (Face) & 1100 N (Edge), minimum compressive
strength of 58N/mm2. modules of elasticity 900 N/mm2 and resistance
to spread of flame of Class A category with properly of being termite/
borer proof, water/moisture proof and fire retardant and fixed in position
with M. S. hold fast/lugs/SS dash fasteners of required dia and length
complete as per direction of Engineer-in-Chargo (M. S hold fast/lugs Or
SS dash fasteners shall be paid for separately).
Nole: For WPC solid door/window frames. minces. 5mm tolerance in
dimension i.e. depth and width of profile shall be acceptabe Variation in
profile dimensions on plus side be acceptable but no extra payment on
this account shall be made.

Frame size 65 x 125mm Rmt 5.20 1091.00 5673.20 59.00 1091 64369
Providing and fixing aluminium tower bolts anodised (anodic coating not
less than grade AC 10 as per IS:1868) transparent or dyed to required
colour or shade with necessary screws etc. complete:

300x10mm Each 1.00 116.80 116.80 1.00 116.8 116.8


100x10 mm Each 1.00 58.15 58.15 1.00 58.15 58.15
Providing and fixing aluminium sliding door bolts, ISI marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868), transparent
or dyed to required colour or shade, with nuts and screws etc. complete :

300x16 mm Each 1.00 257.15 257.15 1.00 257.15 257.15


250x16 mm Each 1.00 231.70 231.70 1.00 231.7 231.7
Providing and fixing aluminium handles anodised (anodic coating not
less than grade AC 10 as per IS:1868) transparent or dyed to required
colour or shade with necessary screws etc. complete:
125mm Each 2.00 59.65 119.30 2.00 59.65 119.3
Providing and fixing aluminium hanging floor door stopper anodised
(anodic coating not less than grade AC 10 as per IS:1868) transparent or
dyed to required colour and shade with necessary screws etc. complete.

Twin rubber stopper Each 1.00 62.05 62.05 1.00 62.05 62.05
Providing and fixing aluminium work for doors, windows, ventilators
and partitions with extruded built up standard tubular sections/
appropriate Z sections and other sections of approved make conforming
to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and
size, including necessary filling up the gaps at junctions, i.e. at top,
bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including
cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass /
stainless steel screws, all complete as per architectural drawings and the
directions of Engineer-in-charge. (Glazing, paneling and dash fasteners
to be paid for separately) :
For fixed portion

Powder coated aluminium (minimum thickness of powder coating 50


kg 10.40 267.00 2775.47 10.40 267 2775.465
micron)
For shutters of doors, windows & ventilators including providing and
fixing hinges/ pivots and making provision for fixing of fittings wherever
required including the cost of EPDM rubber / neoprene gasket required
(Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50
kg 13.37 309.00 4129.79 13.37 309 4129.785
micron)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/
Stone work by providing weather silicon sealant over backer rod of
approved quality as per architectural drawings and direction of Engineer- mtr 6.90 68.00 469.20 6.90 68 469.2
in-charge complete.
Upto 5mm depth and 5 mm width
Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and
Sqm 1.49 880.00 1306.80 1.49 880 1306.8
1.4mm wide aperture with matching beading
Providing and fixing glazing in aluminium door, window, ventilator
shutters and partitions etc. with EPDM rubber / neoprene gasket etc.
complete as per the architectural drawings and the directions of Engineer-
in-charge . (Cost of aluminium snap beading shall be paid in basic item):

With float glass panes of 5.00 mm thickness (weight not less then 12.50
Sqm 2.97 903.00 2681.91 2.97 903 2681.91
kg/sqm)

Total
Steel Work
Steel work welded in built up sections/framed worK including cutting
hoisting, rixing in position and applying a priming coat of approved steel
primer using structural steel, etc. as required.
In gratings, frames, guard bar, ladders, railings, brackts. gates & similar
Kg 1044.55 95.00 99232.25 1044.55 95 99232.25
works.
Supplying and fixing rolling shutters of approved make, made of
required size M.S. laths, interlocked together through their entire length
and jointed together at the end by end locks, mounted on specially
designed pipe shaft with brackets, side guides and arrangements for
inside and outside locking with push and pull operation complete,
including the cost of providing and fixing necessary 27.5 cm long wire
springs manufactured from high tensile steel wire of adequate strength
conforming to IS: 4454 - part 1 and M.S. top cover of required thickness
for rolling shutters.

80x1.25 mm M.S. laths with 1.25 mm thick top cover Sqm 0.00 2303.00 0.00 2303
Providing and fixing ball bearing for rolling shutters. Each 0.00 364.00 0.00 364
Extra for providing mechanical device chain and crank operation for
operating rolling shutters.
Exceeding 10.00 sqm and up to 16.80 sqm in the area Sqm 0.00 960.00 0.00 960
Extra for providing grilled rolling shutters manufactured out of 8 mm dia
M.S. bar instead of laths as per design approved by Engineer-in- charge, Sqm 0.00 871.00 0.00 871
(area of grill to be measured).
Total
FLOORING AND CLADDING WORK
Providing and fixing Ist quality ceramic glazed wall tiles conforming to
IS: 15622 (thickness to be specified by the manufacturer), of approved
make, in all colours, shades except burgundy, bottle green, black of any
size as approved by Engineer-in-Charge, in skirting, risers of steps and
dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sqm 1742.25 902.00 1571504.99 1742.25 902 1571504.99
sand) and jointing with grey cement slurry @ 3.3kg per sqm, including
pointing in white cement mixed with pigment of matching shade
complete.

Providing and laying Ceramic glazed floor tiles of size 300x300 mm


(thickness to be specified by the manufacturer) of 1st quality conforming
to IS : 15622 of approved make in colours such as White, Ivory, Grey,
Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 sqm 371.24 1006.00 373467.44 371.24 1006 373467.44
Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including
pointing the joints with white cement and matching pigment etc.,
complete.

62 mm thick cement concrete flooring with concrete hardener topping,


under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand
: 4 graded stone aggregate 20mm nominal size) and top layer 12mm
thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2
graded stone aggregate, 6mm nominal size) by volume, hardening sqm 152.15 854.30 129981.75 152.15 854.3 129981.745
compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s
specifications. This includes cost of cement slurry, but excluding the cost
of nosing of steps etc. complete.

Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1


cement : 3 coarse sand), finished with a floating coat of neat cement.

18 mm thick sqm 15.22 521.15 7929.30 15.22 521.15 7929.29725

Total
ROOF & FALSE CEILING WORK
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 stone aggregate 10 mm and down gauge), including finishing
with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :

In 75x75 mm deep chase MTR 103.46 237.25 24545.89 103.46 237.25 24545.885
Making khurras 45x45 cm with average minimum thickness of 5 cm
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400
micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse Each 4.00 244.05 976.20 4.00 244.05 976.2
sand) and a coat of neat cement, rounding the edges and making and
finishing the outlet complete.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x
20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70
and initial emittance > 0.75 on waterproof and sloped surface of terrace,
laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4
coarse sand) and grouting the joints with mix of white cement & marble
powder in ratio of 1:1, including rubbing and polishing of the surface up Sqm 523.39 1374.10 719190.20 523.39 1374.1 719190.199
to 3 cuts complete, including providing skirting up to 150 mm height
along the parapet walls in the same
manner.

Total
FINISHING WORK
12 mm cement plaster of mix :
1:6 (1 cement: 6 sand) Sqm 298.84 150.00 44825.93 298.84 150 44825.925
15 mm cement plaster on rough side of single or half brick wall of mix :

1:6 (1 cement: 6 sand) Sqm 298.84 206.00 61560.94 298.84 206 61560.937
6 mm cement plaster of mix :
1:3 (1 cement: 3 sand) Sqm 606.89 134.00 81323.26 606.89 134 81323.26
Neat Cement Punning` sqm 371.24 40.00 14849.60 371.24 40 14849.6
Distempering with oil bound washable distemper of approved brand and
manufacture to give an even shade :
New work (two or more coats) over and including water thinnable
Sqm 570.32 153.45 87515.45 570.32 153.45 87515.45055
priming coat with cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with
Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and
including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Sqm 103.00 161.15 16598.45 103.00 161.15 16598.45

Painting with synthetic enamel paint of approved brand and manufacture


of required colour to give an even shade:
Two or more coats on new work over an under coat of suitable shade
Sqm 208.91 177.15 37008.41 208.91 177.15 37008.4065
with ordinary paint of approved brand and manufacture.
Total 0.00 0
WATER PROOFING WORK 0.00 0
Providing and laying integral cement based treatment for water proofing
on horizontal surface at all depth below ground level for under ground
structures as directed by Engineer-in-Charge and consisting of :
(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone
slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse
sand) mixed with water proofing compound conforming to IS:2645 in the
recommended proportion over the leveling course (leveling course to be
paid separately). Joints sealed and grouted with cement slurry mixed
with water proofing compound.
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse
sand) mixed with water proofing compound in recommended
proportions.
(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size
spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.

Using rough kota stone. sqm 645.01 1353.70 873150.04 645.01 1353.7 873150.037
Providing and laying integral cement based treatment for water proofing
on the vertical surface by fixing specified stone slab 22 mm to 25 mm
thick with cement slurry mixed with water proofing compound
conforming to IS:2645 in recommended proportions with a gap of 20 mm
(minimum) between stone slabs and the receiving surfaces and filling the
gaps with neat cement slurry mixed with water proofing compound and
finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3
coarse sand) 20 mm thick with neat cement punning mixed with water
proofing compound in recommended proportion complete at all levels
and as directed by Engineer-in-charge :

Using rough Kota stone sqm 509.15 1738.00 884909.65 509.15 1738 884909.652
Providing and laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement
admixed with water proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including adjoining
walls up to 300 mm height including cleaning the surface before
treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm
to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 coarse sand) admixed

with water proofing compound conforming to IS : 2645 and approved by


Engineer-in-charge to required slope and treating similarly the adjoining
walls up to 300 mm height including rounding of junctions of walls and
slabs.
(c) After two days of proper curing applying a second coat of cement
slurry using 2.75 kg/ sqm of cement admixed with water proofing
compound conforming to IS : 2645 and approved by Engineering-charge.

(d) Finishing the surface with 20 mm thick jointless cement mortar of


mix 1:4 (1 cement :4 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineering-charge
including laying glass fibre cloth of approved quality in top layer of
plaster and finally finishing the surface with trowel with neat cement
slurry and making pattern of 300x300 mm square 3 mm deep

(e) The whole terrace so finished shall be flooded with water for a
minimum period of two weeks for curing and for final test. All above
operations to be done in order and as directed and specified by the
Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as
Sqm 523.39 1178.00 616553.42 523.39 1178 616553.42
65 mm.
30605010.28 30605010.28
-4300003.945 -4300003.945
26305006.34 26305006.34
-263050.0634 -263050.0634
AMOUNT OF STP CIVIL (G) 26041956.28 26041956.28 0.00

H UG TANK

Earth work in excavation by mechanical means (Hydraulic


excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in
1 width as well as 10 sqm on plan) including getting out and disposal of 685.27 181.85 124617.08 181.85 124617.0769
excavated earth lead upto 50 m and lift upto 1.5 m, as directed by
Engineer-in-charge. All kinds of soil
CUM. 685.274

Filling available excavated earth (excluding rock) in trenches, plinth,


sides of foundations etc. in layers not exceeding 20cm in depth,
2 67.51 219.65 14829.45 219.65 14829.4501
consolidating each deposited layer by ramming and watering, lead up to
50 m and lift upto 1.5 m. CUM. 67.514
TOTAL

B METAL FILLING
4 300mm thick crushed stone CUM. 44.85 1986.18 89080.17 44.85 1986.18 89080.173

C PCC WORK

Providing and laying Cement concrete 1:5:10 including supply of all


materials, labour and T&P etc. required for proper completion of the
5 15.44 5520.30 85255.51 5520.3 85255.5132
work and curing complete, also including cost of formwork in
foundation. CUM. 15.444
TOTAL

D RCC WORK

6 Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per approved
design mix, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work, including pumping of R.M.C.
from transit mixer to site of laying , excluding the cost of centering,
shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability
as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum.
Excess/ less cement used as per design mix is payable/recoverable
separately).

All works upto plinth level CUM. 54.05 8398.65 453980.63 54.054 8398.65 453980.6271

Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per approved
design mix, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work, including pumping of R.M.C.
from transit mixer to site of laying , excluding the cost of centering,
7 shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability
as per direction of the Engineer - in - charge.
(Note :- Cement content considered in this item is @ 330 kg/cum.
Excess/ less cement used as per design mix is payable/recoverable
separately).

All works above plinth level upto floor V level CUM. 118.08 9802.20 1157443.78 118.08 9802.2 1157443.776

TOTAL
E SHUTTERING WORK

Centering and shuttering including strutting, propping etc. and removal


8
of form for :
Foundations, footings, bases of columns, etc. for mass concrete Sqm 123.55 284.85 35193.79 123.552 284.85 35193.7872
Walls (any thickness) including attached pilasters, butteresses, plinth and
458.44 609.30 279327.49 609.3 279327.492
string courses etc. Sqm 458.44
Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 336.77 552.05 185913.88 336.77 552.05 185913.8785
Suspended floors, roofs, landings, balconies and access platform Sqm 163.14 693.05 113064.18 163.14 693.05 113064.177

TOTAL

F REINFORCEMENT STEEL WORK

Steel Reinforcement for R.C.C. work including straightening, cutting,


bending, placing in position and binding all complete plinth lvl. & above
9 23253.00 83.50 1941625.50 83.5 1941625.5
plinth level. Thermo-Mechanically Treated bars.
KG 23253
TOTAL

G 230 MM BRICKWORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class
10 designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1
cement : 6 coarse sand)
CUM. 7.56 6157.65 46577.33 7.56414 6157.65 46577.32667
TOTAL

H PLASTER WORK

12 mm cement plaster in single coat on rough side of single or half brick


wall for interior plastering upto floor two level including brick wall for
interior plastering upto floor two level including internal rounded angles
11 chamfers and/or rounded angles not exceeding 80mm in girth and
finished evenand smooth no. extra for mixing and additive. (iii) 1cement
:6 COARSE sand
SQM. 183.20 263.55 48282.36 183.2 263.55 48282.36

15 mm cement plaster on rough side of single or half brick wall of mix:


12 1:6 (1 cement: 6 coarse sand)

SQM. 5.56 303.90 1689.68 5.56 303.9 1689.684

13 WATER PROOFING
Providing and laying water proofing treatment in sunken portion of WCs,
bathroom etc., by applying cement slurry mixed with water proofing
cement compound consisting of applying :

First layer of slurry of cement @ 0.488 kg/sqm mixed with


water proofing cement compound @ 0.253 kg/ sqm. This layer will be
0.00 0
allowed to air cure for 4 hours.

Second layer of slurry of cement @ 0.242 kg/sqm mixed with water


proofing cement compound @ 0.126 kg/sqm. This layer will be allowed
to air cure for 4 hours followed with water curing for 48 hours.

The rate includes preparation of surface, treatment and sealing of all


joints, corners, junctions of pipes and masonry with polymer mixed 238.93 465.60 111243.48 465.6 111243.48
slurry.) 238.925
4688124.30 4688124.302
TOTAL -658681.46 -658681.4644
4029442.84 4029442.837
-40294.43 -40294.42837
AMOUNT OF UG TANK (H) 3989148.41 3989148.409 0.00

I OHT
Earth work in exacavation in trenches for foundations in ordinary
soil(loan clay or sand) including lift upto 1.5 m and dressing of sides and
1. CUM 176.63 90.00 15896.25 90.00 15896.25
ramming of bottom sand disposal of surplus excavated earth as directed
by the Engineer i/c with in alead of 50m. 176.63
Providing and laying Cement concrete 1:4:8 (1cement :4 C. sand :8
graded stone ballast 40 mm. nominal size) including supply of all
2. materials, labour and T&P etc. required for proper completion of the CUM 16.39 4470.00 73266.88 4470.00 73266.88
work and curing complete, also including cost of formwork in
foundation. 16.39

Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per approved
design mix, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work, including pumping of R.M.C.
3 from transit mixer to site of laying , excluding the cost of centering, CUM 5.40 8594.65 46411.12 8594.65 46411.12
shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability
as per direction of the Engineer-in-charge.

5.40
Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per approved
design mix, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work, including pumping of R.M.C.
4 from transit mixer to site of laying , excluding the cost of centering, CUM 59.23 8594.65 509060.92 8594.65 509060.92
shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability
as per direction of the Engineer-in-charge.

59.23
0.00 0.00
Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per approved
design mix, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work, including pumping of R.M.C.
5 from transit mixer to site of laying , excluding the cost of centering, CUM 33.30 8594.65 286199.32 8594.65 286199.32
shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability
as per direction of the Engineer-in-charge.

33.30
Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per approved
design mix, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work, including pumping of R.M.C.
6 from transit mixer to site of laying , excluding the cost of centering, CUM 38.53 7364.01 283718.99 7364.01 283718.99
shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability
as per direction of the Engineer-in-charge.

38.53
Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per approved
design mix, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work, including pumping of R.M.C.
7 from transit mixer to site of laying , excluding the cost of centering, 0.00 0.00
shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability
as per direction of the Engineer-in-charge.

A All works upto plinth level CUM 0.83 7364.01 6104.47 0.83 7364.01 6104.47
0.00 0.00
Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per approved
design mix, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work, including pumping of R.M.C.
B from transit mixer to site of laying , excluding the cost of centering, CUM 13.56 8594.65 116584.73 8594.65 116584.73
shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability
as per direction of the Engineer-in-charge.

13.56
0.00 0.00
T.M.T.-FE-500 steel or iron in plain work such as reinforced concrete or
reinforced, brick work (when not included in over all rates ) wrought to
8 required shape as necessary including bending for proper completion of QTL 283.52 7321.35 2075770.21 7321.35 2075770.21
the work and including supply of all steel and wastage & over lapping &
hooks. 283.52

Structural steel work riveted, bolted or welded in built up sections,


trusses
9 KG 3519.97 89.22 314035.03 89.22 314035.03
and framed work, including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer all complete. 3519.97

Painting or vanishing two coats on iron works in small areas or new


wood work with one coat of ready mixed priming paint & one coat of
approved superior quality ready mixed paint of clear synthetic varnish
10 including supply of all materials labour and T & P etc. required for SQM 3519.97 90.18 317430.89 90.18 317430.89
proper completion of work.Paint to be used should confirm to the I.S.I
No.103 1950 3519.97

11 Stairs, (excluding landings) except spiral-staircases SQM 36.00 545.68 36.00 545.68

12 Arches, domes, vaults up to 6 m span SQM 346.43 1502.15 520385.24 346.43 1502.15 520385.24

13 Lintels, beams, plinth beams, girders, bressumers and SQM 135.50 484.04 65588.82 135.50 484.04 65588.82
cantilevers

14 Foundations, footings, bases of columns, etc. for mass concrete SQM 9.20 249.76 2297.78 9.20 249.76 2297.78

15 Columns, Pillars, Piers, Abutments, Posts and Struts SQM 143.94 643.31 92597.12 143.94 643.31 92597.12

16 M-150 brick work in 1:4 cement and coarse sand of 2.25 coarseness
modulus mortar in super-structure. Above plinth level up to floor two
level (up to two storey) including necessary cutting and molding of brick 1.80 4300.00 7,740.00 4300.00 7740.00
work as required and also including honey combed brick work in
thickness of wall 12cms. Cu.M 1.80

17 15mm cement plaster in single coat on fair side of single or half brick
wall for exterior plastering up to floor two level including internal
rounded angles chamfers, and/or rounded angles not exceeding 80mm in Sq.M 300.92 181.25 54,540.84 181.25 54540.84
girth and finished even and smooth. (1) 1 cement : 6 coarse sand
(1.25FM) 300.92

18 Providing and applying plaster of paris putty of 2 mm thickness over


plastered surface to prepare the surface even and smooth complete. Sq.M 150.91 172.47 26,026.75 172.47 26026.75
150.91

19 Finishing wall with water proof cement paint of approved make and
quality on new work with two coats to give an even shade including
Sq.M 150.91 83.00 12,525.32 83.00 12525.32
supply of all materials , laour ,tools and pants etc. required for proper
completion of the work. 150.91

Providing and laying water proofing treatment in sunken portion of WCs,


bathroom etc., by applying cement slurry mixed with water proofing
cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed
20 to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Sq.M 290.46 408.24 118576.69 408.24 118576.69
kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm.
This layer
will be allowed to air cure for 4 hours followed with water curing for 48
hours. 290.46
Providing and laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations: (a) Applying a
21 slurry coat of neat cement using 2.75 kg/sqm of cement admixed with
water proofing compound conforming to IS. 2645 and approved by
Engineer-in-charge over the RCC

With average thickness of 120 mm and minimum


SQM 236.92 1226.22 290515.07 1226.22 290515.07
thickness at khurra as 65 mm. 236.92

62 mm thick cement concrete flooring with concrete hardener topping,


under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm
thick cement hardener consisting of mix 1:2 (1 cement hardener
mix : 2 graded stone aggregate, 6mm nominal size) by volume,
22 hardening compound mixed @ 2 litre per 50 kg of cement or as per SQM 113.04 749.06 84673.45 749.06 84673.45
manufacture’s specifications. This includes cost of cement slurry, but
excluding the cost of nosing of steps etc. complete.

113.04

23 Extra cost for scaffholding with different staging 1000000.00 1000000.00

24
a. providing and fixing G.I.pipescomplete with
G.I. fitting and clamps including
cuttingand making good the walls.
40 mm dia nominal bore (inlet) R.M. 40.00 560.81 22432.27 40.00 560.81 22432.27
65 mm dia nominal bore (outlet) R.M. 25.00 627.79 15694.87 25.00 627.79 15694.87
40 mm dia nominal bore (wash out) R.M. 25.00 560.81 14020.17 25.00 560.81 14020.17
65 mm dia nominal bore (overflow) R.M. 30.00 627.79 18833.84 30.00 627.79 18833.84

b. 40 mm dia nominal bore pump room to OHT pipeline R.M. 250.00 560.81 140201.67 250.00 560.81 140201.67
65 mm dia nominal bore OHT to building line R.M. 214.00 627.79 134348.09 214.00 627.79 134348.09

c. Painting G.I. pipes and fittting with


synthetic enamel white paint over a ready
mixed priming coat, both of approved
quality for new work
40 mm dia nominal bore R.M. 90.00 29.29 2635.69 90.00 29.29 2635.69
65 mm dia nominal bore R.M. 25.00 34.90 872.42 25.00 34.90 872.42

d providing and fixing gun metal gate valve


with C I wheels of approved
qualityn(serewed ends)
40 mm dia nominal bore EACH 3.00 594.83 1784.48 3.00 594.83 1784.48
65 mm dia nominal bore EACH 2.00 1304.78 2609.56 2.00 1304.78 2609.56
AMOUNT OF OHT (I) 6673378.94 6673378.94 0.00

J BOUNDARY WALL
1 Earth -work in exacavation in trenches for foundation and for pipes,
cable etc. in ordinary soil (Loan clay or sand) including lift upto 1.5 m
lead upto 50 m. and dressing of sides and ramming of bottoms and Cu.M 1602.24 90.00 1,44,202.03 1910.41 90.00 1,71,936.47
disposal of surplus excavated earth as directed by the Engineer. i/c
within a lead of 30 m. .
2 2.5cm thick Damp proof course with cement concrete consisting of 1 part
cement ,1.5 pats approved coarse sand and 3 parts approved 10 mm
graded stone grit and including water proofing material as orderd by the Sq.M 423.69 300.00 1,27,108.38 505.18 300.00 1,51,555.19
Engineer Incharge in the proportion as specified by the manufacture.

3 Providing & applying a coat of residual petroleum bitumen of grade of


VG-10 of approved quality using 1.7kg per square metre on damp proof
course after cleaning the surface with brushes and finally with apiece of Sq.M 423.69 110.00 46,606.41 505.18 110.00 55,570.24
cloth lightly
soaked in kerosene oil.
0.00 0.00
4 Providing and laying Cement concrete 1:4:8 (1cement :4 C. sand :8
graded stone ballast 40 mm. nominal size) including supply of all
materials, labour and T&P etc. required for proper completion of the Cu.M 180.16 4470.00 8,05,303.76 214.81 4470.00 9,60,188.18
work and curing complete, also including cost of formwork in
foundation.
5 Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per approved
design mix, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work, including pumping of R.M.C.
from transit mixer to site of laying , excluding the cost of centering, 0.00 0.00
shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability
as per direction of the Engineer-in-charge.

5.A All works upto plinth level CUM 439.47 8398.65 36,90,925.18 523.99 8398.65 44,00,802.45
5.B All works above plinth level upto floor V level CUM 221.55 9802.20 21,71,707.55 264.16 9802.20 25,89,393.03
0.00 0.00
6 T.M.T.-FE-500 steel or iron in plain work such as reinforced concrete or
reinforced, brick work (when not included in over all rates ) wrought to
required shape as necessary including bending for proper completion of QTL 616.56 7081.00 43,65,832.26 735.14 7081.00 52,05,514.71
the work and including supply of all steel and wastage & over lapping &
hooks.
0.00 0.00
7 M-150 brick work in 1:6 cement and coarse sand of 2.25 fineness
modulous mortar in foundation and plinth including supply of all
Cu.M 646.13 3900.00 25,19,923.59 770.41 3900.00 30,04,581.60
materials, labour and tools and plants etc. required for proper completion
of the work.
0.00 0.00
8 M-150 brick work in 1:6 cement and coarse sand mortar in super
structure including necessary cutting and moulding of bricks required
and also including honey comb brick work thickness of walls more than Cu.M 635.54 4330.00 27,51,896.38 757.78 4330.00 32,81,169.82
one brick and for extra labour to above items

0.00 0.00
9 Proving & injecting chamical emulsion for preconstructional anti-termite
treatment and creating a chemical barrier under & alround the column
pits wall trenches basement excavation top surface if plinth filling
junction of wall & floor along the external perimeter of building
expansion joints surrounding of pipes & coduits etc.complete plinth area
of the building at ground floor only shall be measured as per I.S.63/3( 0 0.00
part II 1981 ) Aldrine emlsifiable concentrate or any other approved
material such as Htrachlore or Chlordance will be used . The rate of
application of chemical emulsion shall be as follows:

(I) Treatment for masonary & foundation 5litres/ sqm. 0.00 0.00
(II) Back fill in immediate contract with foundation 7.5 litres / sqm. 0.00 0.00
(III) Treatment of top surface of plinth filling 5 litres/sqm . 0.00 0.00
(IV) Treatment of junction of wall and floor 7.5litres/sqm. 0.00 0.00
(V) Treatment of soil along external perimeter of building 7.50 0.00 0.00
litres/sqm.
(VI) Treatment of soil under Apron along external perimeter 5litres/sqm
Sq.M 1592.28 200.0 3,18,456.68 1898.53 200.0 3,79,705.59
0.00 0.00
10 12 mm cement plaster in single coat on rough side of single or half
brick wall for interior plastering up to floor two level including internal
Sq.M 3043.20 263.55 8,02,035.36 3628.50 263.55 9,56,291.18
rounded angles not exceeding 80 mm in girth and finshed even and
smooth. (1)1 cement : 6 coarse sand.
0.00 0.00
11 15mm cement plaster in single coat on fair side of single or half brick
wall for exterior plastering up to floor two level including internal
rounded angles chamfers, and/or rounded angles not exceeding 80mm in Sq.M 3043.20 303.90 9,24,828.48 3628.50 303.90 11,02,701.15
girth and finished even and smooth. (1) 1 cement : 6 coarse sand
(1.25FM)
0.00 0.00
12 Providing wall putty on old surface with approvel quality material of
Sq.M 6086.40 54.00 3,28,665.60 7257.00 54.00 3,91,878.00
Berger/J.K./Birla or similar make 2 coats
0.00 0.00
13 White washing one coat including supply of all materials , labour and T
& P etc required for proper completion of work. Sq.M 6086.40 22.00 1,33,900.80 7257.00 22.00 1,59,654.00

14 M.S or iron work of small sizes and section such as holding down bolts,
hold fast ,tie rods, grading etc, ( When not including in an overall rates )
wrought to required shape as necessary for bending etc including supply
of steel and its wastage including cost of bolts nuts if required and 0.00 0.00
welding ,grinding and making holes as required for proper completion of
works
Fabrication of M.S grill / MS hollow bar over boundary wall KG 36518.40 61.50 22,45,881.60 43542.00 61.50 26,77,833.00
15 Painting or vanishing two coats on iron works in small areas or new
wood work with one coat of ready mixed priming paint & one coat of Sq.M 1217.28 104.00 1,26,597.12 1451.40 104.00 1,50,945.60
approved superior quality ready mixed paint of clear synthetic varnish
including supply of all materials labour and T & P etc. required for
FORM WORK 0.00 0.00
16 Centering and shuttering including strutting, propping etc. and removal
of form for : 0.00 0.00

Foundations, footings, bases of columns, etc. for mass concrete 2958.80 284.85 8,42,814.73 3527.87 284.85 10,04,913.66
0.00 0.00
Lintels, beams, plinth beams, girders, bressumers and
921.08 552.05 5,08,479.56 1098.23 552.05 6,06,275.66
cantilevers
1,38,67,768.19 89,87,397.27
LESS GST 14.05 % 78,80,225.58 16534962.17 1,07,15,947.35
LESS 1% LABOUR CESS ON DSR( ON TOTAL AFTER
79,59,027.83 93,95,832.84
DEDUCTION 14.05%)
1,38,67,768.19 79,59,027.83 1,65,34,962.17 94,89,791.17
AMOUNT INCREASE DUE
TO ADDITIONAL
AMOUNT OF BOUNDARY WALL (J) 2,18,26,796.02 2,60,24,753.34 41,97,957.32 LENGTH OF BOUNDARY
WALL AFTER MERGER
OF DEGREE COLLEGE
K ENTRANCE GATE
1.
Excavation in foundation in ordinary soil (Loam,clay or sand) including
lift upto 1.50 M and lead upto 30 M.and including filling watering and
ramming of excavated earth into the trenches or into the space between 23.04 90.00 2073.22 23.0358 90 2073.222
the building and the sides of foundation trenches or into the plinth and
removal and disposal of surplus earth as directed by the Engineer-in-
charge upto a distance of 30 M from the foundation trenches. CUM

2 (a) Sand filling in plinth and under floor including supply of necessary
quantity of sand from a distance not exceeding 8 Kms. from the site of
work and including watering, dressing etc. labour and T&P etc.
required for proper complition of the work. saplings of girth upto 30
cms. measured at a height of 1 M. above ground level and removal of 16.13 380.00 6127.52 16.12506 380 6127.5228
rubbish upto a distance of 50 M. out side the periphery of area cleared.
including cost of sand.
CUM

3 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand


:8 stone grit 40 mm nominal size) and curing complete,including cost of 1.20 3030.00 3626.64 1.1969125 3030 3626.644875
form- work,in foundation and floors. CUM

4 Providing and laying in position ready mixed M-25 grade concrete for
reinforced cement concrete work, using cement content as per approved
design mix, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work, including pumping of R.M.C.
from transit mixer to site of laying , excluding the cost of centering,
shuttering finishing and reinforcement, including cost of admixtures in
recommended proportions as per IS : 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability
as per direction of the Engineer-in-charge.

4A All works upto plinth level CUM 5.71 8398.65 47,930.76 5.70696 8398.65 47930.7596
4B All works above plinth level upto floor V level CUM 2.96 9802.20 29,011.08 2.95965 9802.2 29011.08123
in1:1.5:3having strength not less than M
150. (PWD- 289 ) CUM 2.56 9600.00 24537.60 2.556 9600 24537.6

7. Mild steel or iron in plain work such as


reinforced concrete or reinforced, brick

5 Mild steel or iron in plain work such as reinforced concrete or reinforced,


brick work (when not included in anover all rates ) wrought to
required shape as necessary including bending for proper completion of
the work and including supply of steel its wastage bend hooks and 8.450 7081.00 59833.10921 8.44981065 7081 59833.10921
authorised over lapping shall be measured upto floor two level.
QTL.
6 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25
fineness modulus) mortar in foundation & plinth including supply of all
1.766 3900.00 6888.375 1.76625 3900 6888.375
materials, labour and T & P etc required for proper completion of the
work. CUM

7 Brick work with non modular fly ash bricks conforming to IS:12894,
class designation 10 average compressive strength in super structure
above plinth level up to floor V level in : Cement mortar 1:6 (1 cement :
6 coarse sand) 2.687 7280.70 19565.57072 2.68732 7280.7 19565.57072

CUM

8 Brick work with non modular fly ash bricks conforming to IS:12894,
class designation 10 average compressive strength in super structure
above plinth level up to floor V level in : Cement mortar 1:6 (1 cement :
6 coarse sand) 0.215 7280.70 1567.389096 0.21528 7280.7 1567.389096

CUM

9 12 mm cement plaster in single coat on rough side of single or half


brick wall for interior plastering up to floor two level including internal
7.91 156.00 1233.96 7.91 156 1233.96
rounded angles not exceeding 80 mm in girth and finshed even and
smooth. (1)1 cement : 6 coarse sand SQM

10 Finishing walls with acrylic smooth extarior paint with silicon addtives
of required shed. Two or more coat applied @1.43 ltr/10sqm. Over and
4.14 164.70 681.86 4.14 164.7 681.858
including base coat of water proofing cement paint applied @ 2.20kg/10
sqm. SQM

11 Wall lining butch work upto 10m height with Dholpur stone 40 mm thick
rough facing on the exposed surface with stone strips of minimum length
300 mm and required width, including embedding every tenth layer and
bottom most layer in masonry or concrete after making necessary chases
of size 75x75 mm and by providing layer of 75 mm thick strips i/c 12 0.00 2388.00 0.00 0 2388 0
mm thick bed of cement mortar 1:3 (1 Cement : 3 coarse sand) i/c ruled
pointing in cement mortar 1:2 (1 white cement : 2 stone dust) with an
admixture of pigment to match the shade of stone complete as per
direction of Engineer-in-charge. SQM

12 Providing wall putty on New surface with approvel quality material of


4.14 67.00 277.38 4.14 67 277.38
Berger/J.K./Birla or similar make 2 coats SQM

13 P/L in cement concrete 1: 2: 4 (1 cement: 2 coarse sand : 4 graded


stone grit 20mm nominal size and curing complete including cost of
form work for fixing of hold fasts including of supply of all materials 0.00 5280.00 0.00 0 5280 0
labour T&P etc.required for proper completion of work. Strength should
not be less than M-150. CUM

14 Same as in item 502 above but in heavy sizes such as trusses, built up
gates, record racks, roof work, Gates etc. including rivetting or welding 270.00 61.50 16605.00 270 61.5 16605
where necessary. KG

15 Painting Ist coat over priming coat (but excluding cost of priming coat)
on steel and other metal surfaces up to 10 cm. width or girth or
small articles not exceeding 0.10sqm in area white superior synthetic
enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX
specified brushing to give an even shade and including cleaning the 4.50 104.00 468.00 4.5 104 468
surface of all dirt,dust and other foreign matter sand papering and
stoping including cost of all materials, labour tools and plants etc.
required for proper completion of the work.
SQM

121670.81 98756.66 121670.8139 98756.65865

-13875.31 -13875.31054
84881.35 84881.34811
121670.81 121670.8139
N.TOTAL 206552.16 N.TOTAL 206552.162
G TOTAL 206552.16 G TOTAL 206552.162
AMOUNT OF ENTRANCE GATE (K) FOR 2 NOS 413104.324 FOR 2 NOS 413104.324 0

L CC ROAD
Earth work in exacavation in trenches for foundations in ordinary soil(loan clay or
sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand
1 disposal of surplus excavated earth as directed by the Engineer i/c with in alead CUM 7501.33 90 675119.7 7501.33 90 675119.7
of 50m.(PWD-251)

2 CARTED OF EART FILLING CUM 13891.36 318.1 4418840.821 13891.36 318.1 4418840.821

Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8


graded stone aggregate 40 mm nominal size) and curing complete, including cost
3 of form-work, in foundation and floors.(PWD-281) CUM 3505.25 4470 15668467.5 3505.25 4470 15668467.5

M-150 Brick Work in 1:4 (One cement & four Corse sand)
4 mortar.foundation and plinth including supply of all materials labour, CUM 3195.01 4300 13738543 3195.01 4300 13738543
Tools & plants etc. required for proper completion of the work 305-B

Construction of un-reinforced, dowel jointed at expansion and construction joint


only, plain cement concrete pavement, thickness as per disign, over a prepared
sub base with 43 grade cement or any other type as per Clause 1501.2.2 (1:1½:3)
coarse and fine aggregates confirming to IS 383 maximum size of coarse
aggregate not exceeding 25 mm, mixed in a concrete mixer of not less then 0.2
cum capacity and appropriate weight batcher using approved mix design, laid in
approved fixed side form work (steel channel, laying and fixing of 125 micron thick
polythene film, wedges, steel plates including levelling the formwork as per
drawing), spreading the concrete with shovels. rakes, compacted using needle,
screed and plate vibrators and finished in continuous operation including provision
5 CUM 4630.45 6500 30097925 4630.45 6500 30097925
of contraction and expansion, construction joints as per norms, applying debonding
strips primer, sealant, dowel bars, near approaches to bridge/ culvert and
construction, joints, admixtures as approved, curing of concrete slabs for 14-days,
curing compound (Where specified) and water finishing to lines and grade as per
drawing and Technical Specification Clause 1501 including Cost of Polythene
Sheet and Dowel bar and also including complete shifting of matrials & Concrete
etc.(M-20

Providing and laying in position bitumen hot sealing compound for expansion joints
6 etc. (DSR- 16.46.1)
RM 9260.91 2.91 26949.25 9260.91 2.91 26949.25
Using grade 'A' sealing compound.

2 cm premix carpet surfacing with 2.4 cum of stone chippings 11.2


mm nominal size per 100 sqm and bitumen emulsion (medium setting
7 min. 65% bitumen content) complying with IS : 8887, using 96 kg SQM 23306.61 142.59 3323289.52 23306.61 142.59 3323289.52
per cum of chippings, including consolidation with road roller of 6 to
9 tonne capacity etc. complete.

AMOUNT OF CC ROAD (L) 67949134.79 67949134.79 0

M PATHWAY
Earth work in exacavation in trenches for foundations in ordinary soil(loan clay or
sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand
1 disposal of surplus excavated earth as directed by the Engineer i/c with in alead CUM 2805.71 90 252513.9 2805.71 90 252513.9
of 50m.(PWD-251)

Cement Concrete with proportions of 8:4:1 stone Ballast, Coarse sand and
2 cement.including supply of all materials, labour, Tools & plants etc. required for CUM 1870.47 4470 8361000.9 1870.47 4470 8361000.9
proper completion of the work.

M-150 Brick Work in 1:4 (One cement & four Corse sand)
3 mortar.foundation and plinth including supply of all materials labour, CUM 898.87 4300 3865141 898.87 4300 3865141
Tools & plants etc. required for proper completion of the work

(a) Sand filling in plinth and under floor including supply of necessary quantity of
sand from a distance not exceeding 8 Kms. from the site of work and including
watering, dressing etc. labour and T&P etc. required for proper complition of the
work. saplings of girth upto 30 cms. measured at a height of 1 M. above ground
4 level and removal of rubbish upto a distance of 50 M. out side the periphery of CUM 779.36 380 296156.8 779.36 380 296156.8
area cleared. including cost of sand.
Supply of 80mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically
compressed interloking cement concerete paver blocks, smooth high gloss finish, skid
resistant; manufactured from rubber moulds through vibro-compression mechanism. high
pressure and control vibration machine having plan dimension 200 x (160+120mm) with
5 minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The SQM 7793.64 726.6 5662858.824 7793.64 726.6 5662858.824
Compressive strength of concerete paver block shall not be less than 40 MPa and weight
4.50 kg per No. confirming to IS: 15658-2006 including cost of material, labour, T & P
(ii ) Color

AMOUNT OF PATHWAY (M) 18437671.42 18437671.42 0

N OVERHEAD & CANTILEVER SIGN BOARD


Supply, fixing and hoisting of 12.00 - 15.00 M span Overhead Structure
in position with two vertical posts of 6.00 M. clear height from the top of
R.C.C. foundation made of 300 mm. dia pipe welded with 10 mm thick
MS plate at bottom supported with 10 mm thick MS plate stiffeners &
two nos.10 mm thick MS plates at top welded with structure of 50 mm
NB (M) pipe comprising of horizontal, vertical pipe of 40 mm NB (M)
and bracing pipe of 32 mm NB (M) as per structural design requirements
and approved drawing with vertical and lateral clearance given in clause
802.2 and 802.3 including one coat of primer and two coat of synthetic Each 4 233000.00 932000 4 233000 932000
enamel paint on the whole structure and installed as per clause 802.7
over a designed support system made up of concrete including
excavation, lean concrete with 1:4:8 cement, coarse sand and approved
20 mm grit and R.C.C. 1:2:4 with cement, coarse sand and approved 20
mm grit complete for fixing the complete structure in position as per
direction of E/I. charge. With 7 years warranty. Rates include design,
fabrication, supply, transportation and erection of the sign board and
also inclusive of all taxes, oyalty, etc
Providing and erecting direction and place identification retro-
reflectiorised sign as per IRC-67 made of high intensity grade sheeting
the retro- reflecive sheeting type -IV shall be tested for 3 year outdoor
weathering test in Indian conditions as per IRC 67-2012 & proof of the
same in form of Government report shall be uploaded while quoting
tender vide MOR&TH clause 801.3 fixed over aluminium sheeting 2mm
thick with area exceeding 0.9 sqm supported on a miled steel single
angle iron post 75x75x6 mm firmly fixed to the ground by means of
property designed foundation with M-15 grade cement concrete Sqm 20 6990.00 139800 20 6990 139800
45x45x60 cm below ground level as per approved drawing complete. as
per direction E-In- Charge
Note : The Composite warranty jointly signed by original
manufacturer & authorized converter of at least 7 years shall be
furnished on non judicial stamp of required denomination both for
retro reflective sheet and also complete signage.

Retro Reflective Signs (Type-IV Sheet) for single side


Providing and fixing retro-reflective signboards comprising of
customised modular PU Epoxy Coated MS angle iron frame work,
aluminum composite panel (ACP) as base board. micro prismatic retro-
reflective sheet and electro cut colored overlay film/latex printing. The
horizontal and vertical members including inclined outer members of the
MS frame module shall be made of pair MS angle iron. No panel size
shall be more than one sqm and each panel shall be braced diagonally
(one way only) with MS angle. The MS frame module shall have length
not more than 3 mtr. The aluminum composite panel (ACP) shall have a
thickness of 4mm with 0.5 mm thick skin of aluminum on both sides.
The ACP shall be fixed on the MS frame with pop riveting or with self
taping SS screws 5mm dia spaced not more than 300mm centre to centre
sqm 20 4949 98980 20 4949 98980
ensuring that no riveting is seen on either face of the frame. On the front
visible face of the ACP, micro prismatic retro-reflective sheet
conforming to Type-IV of ASTM. D 4956-09 shall be pressure fixed. The
retro-reflective sheeting shall be tested for 3 year outdoor weathering test
in Indian conditions as per IRC 67 2012 & proof of the same in form of
government report shall be uploaded with quoting tender. The rate
include all materials, labour, equipments, fabrication, transportation,
erection, installation and incidentals all complete as per direction of the
Engineer-in-Charge. Signage on MS angle frame of (35x35x5)mm
Supply, fixing and hoisting of 6.00-7.00 m. span Cantilever Structure in
position with one vertical post of 6.00 M. clear height from the top of
R.C.C. foundation made of 300 mm. dia pipe welded with 10 mm thick
MS plate at bottom supported with 10 mm thick MS plate stiffners & two
nos. 8 mm thick MS plates at top welded with structure of 40 mm NB
(M) pipe comprising of horizontal, vertical & bracing pipe of 32 mm NB
(M) as per structural design requirements & approved drawing with
vertical & lateral clearance given in clause 802.2 & 802.3 including one
coat of primer and two coats of synthetic enamel paint on the whole
structure & installed as per clause 802.7 over a designed support system EACH 8 125000 1000000 8 125000 1000000
made up of concrete including excavation, lean concrete 1:4:8 cement,
coarse sand and approved 20 mm grit and R.C.C. 1:2:4 with cement,
coarse sand and approved 20 mm grit complete for fixing the complete
structure in position as per direction of E/I charge. With 7 years
warranty. Rates include design, fabrication, supply, transportation and
erection of the signage structure inclusive of all taxes,

AMOUNT OF OVERHEAD & CANTILEVER SIGN BOARD (N) 2170780 21,70,780 0

O TUBEWELL
TUBEWELL 1 2192486 2192486 1 2192486 2192486

AMOUNT OF TUBEWELL (O) 2192486.00 2192486 0.00

G. TOTAL 'A' (A+B+C+D+E+F+G+H+I+J+K+L+M+N+O) 800603532.06 811665077.29 11061545.23

ELEVATION FEATURE AMOUNT DUE TO VARIATION 16695698.97


ADDITIONAL LIFTS 6 NOS 9390000

VARIATION IN BOUNDARY WALL DUE TO CHANGE IN


41,97,957.32
LENGTH

TOTAL 30283656.29
PERCENTAGE BELOW AT WHICH CONTRACTOR HAS
2431777.60
QUOTED FROM THE TENDERED AMOUNT @8.03%
TOTAL AMOUNT OF VARIATION 'B' 27851878.69
278.52 LACS

AMOUNT INCREASED
DUE TO MERGER OF
G. TOTAL (A+B) AS ADMIN & LIBRARY
BLOCK, INCREASE IN
G. TOTAL AS PER DPR 800603532.06 PER REVISED DPR + 839516955.97 38913423.92 BOUNDARY WALL
VARIATION LENGTH, ADDITIONAL
LIFTS & FAÇADE WORK

You might also like