Professional Documents
Culture Documents
Brochures - CLIMAVENETA AISLE CONTAINMENT
Brochures - CLIMAVENETA AISLE CONTAINMENT
Brochures - CLIMAVENETA AISLE CONTAINMENT
CONFIGURATIONS
The CLIMAVENETA AISLE CONTAINMENT SYSTEM Climaveneta Hot Aisle Containment system
is available in two different configurations aimed confines and isolates the server’s hot air
at containing both the hot and cold aisles: discharge from the rest of the environment.
Climaveneta Cold Aisle Containment system The choice of one solution over another greatly
provides strict control over the cold air feeding depends on several factors:
the servers. Environment dimensions, layout, loads trend,
kind of air cooling system, redundancy.
ADVANTAGES
1,2 1,7
2,3
ENHANCED 3,1
EFFICIENCY 1,9
1,5 2,8
MODULAR
STRUCTURE
for perfect integration in PERFECT CONTAINMENT
in-row racks (FLEX) OF HOT AND COLD AISLES
REDUCED INITIAL
INVESTMENT
EASY
EXPANSION
in fast-changing data center
environments
The cold air coming from the perimeter air conditioners is directed Up to 30% increased efficiency thanks to a larger
to the front of the rack through the raised floor. Thanks to the temperature gap between inlet and outlet air
Climaveneta Containment System, the cold air is then contained Constant temperature on the front of the rack at any height,
in the cold aisle, avoiding any mixing between cold air and hot air. as the containment eliminates the normally existing thermal
After that, the air that passes through the rack absorbs the servers’ gradient.
heat and then, is released from the back of the rack and conducted
to the perimeter air conditioners. Thanks to the Cold Air Containment System there is no chance
for the hot exhaust air to mix with the cold inlet air. Therefore,
Well managed airflow and the control over the air temperature the air needed to cool the servers is just inside the aisle,
provide several advantages to the air conditioning system: considerably increasing the system’s efficiency.
Greater control over the temperature of the airflows
KEY FEATURES
CRAC
Stable and uniform temperature levels
at any height of the rack
Higher thermal efficiency and reduced
energy consumption
Baffle
Reduced space occupancy Floor Brush
Seals
HOT AISLE CONTAINMENT SYSTEM
In the Hot Aisle Containment System, the hot airflow generated As a consequence, the difference between the air
by IT devices is contained in a hot aisle. temperature in the corridor and the cooled air is high enough
(>15°C) to ensure the greatest efficiency of the system.
Cold air inside the rack becomes hot as it absorbs the heat from
the server and is then ejected from the back of the rack. The Climaveneta Hot Aisle Containment System is therefore
The Climaveneta Containment System encloses this hot exhaust the best solution to isolate hot air without compromising the
air in the corridor, keeping it separate from airflows with different environment’s temperature, while maintaining high efficiency
temperatures. of the cooling system.
KEY FEATURES
Return Air Plenum
POLYCARBONATE
TRANSPARENT COVERAGE
FAIRLEAD
THERMAL INSULATION
AT THE BASE