SHIMADZU Solutions for Science since 1875 SHIMADZU= =5 5 TG-DTA Sim Measuring Iq OD) Simultaneous TG/DTA improves ease of operation, sensitivity and analytical accuracy of conventional standalone systems If flexibility and high performance is needed in Atmosphere control is programmable. As in various applications, the new DTG-60/60H. DSC, the TA-GOWS provides advanced combines them all: Basic functions required by acquisition, analysis and report functions which simultaneous thermogravimetry/differential ensure comfortable simultaneous measurement, thermal analysis (TG/DTA) measurements are improved. Des ee eae Cie ‘The balance assembly is the heart of every thermogrametric analyzer. The newly designed X-shaped fulcrum provides. high sensitivity and excellent vibration-proof structure because of the light weight and extremely reduced friction and resistance. New A/D technology allows the DTG-60/60H to operate in a very large dynamic mass range. DTG-60/60H has the unique feature of lfferential weight measurement. eee ‘Thermal Analysis Data Fumace Photoelectric conversion ment DTG-60/60H provides a true DTA setup, The sample and the reference position are located at the ends of the balance beam. This differential balance system minimizes baseline drits caused buoyancy or convection during the heating process, ensuring a stable baseline even at high ‘temperatures. Boeke eens Clay shows distinctive characteristics depending on its producing area and composition. In particular, differential thermal analyses (DTA) for clay minerals show distinctive patterns of (1) “Endothermic peak between 50 and 200'C", (2) "Endothermic peak between 300 ‘and 800°C", and (8) "Endothermic/Exothermic peak between 900 and 120°C" depending on the type of clay minerals. Therefore, it can be used for qualitative analysis. ‘The exothermic peak around 1015°C is caused by a change in the crystal structure, With thermogravimetry (T), weight reduction is observed in two steps, corresponding to dehydration of adsorbent water and OH, Mio hun nena ren ‘easour cass [SOLENOID VALVE During TG/DTA measurements, qualitative and quantitative analysis, examination of reaction mechanisms and evaluation of heat resistance are performed by studying various reactions and interactions between a sample and special atmospheres. The unique channel structure of the DTG-60/60H offers the solution for these applications. While an inert gas purges the balance, reactive gases are directly ‘connected to the reaction pan. In combination with the FC~ 0A the measurement is fully software controlled. Tr ee es ‘Tne DTA detector of DTG-60/60H is well balanced between contradictory factors “sensitivity” and “resolution”. Since symmetrical arrangement of two detectors in the furnace provides excellent temperature distribution, even very smal DTA signals such as noise and drift are well matched. Using the convenient plug-in method, the DTA detector ean be quickly replaced. \Specifications \iSpecifications ‘Model DTG-60 (P/N 346-68750-02/89) TA COWS OTe s0/eoH DTG-60H (P/N 346-68700-82/83) S906 ACIPOY,~B3 ar C2900 Balance type Parallel guide diferential top pan type Temperature range | DTG-60: Room temperature to 1100°C DTG-60H: Room temperature to 1500°C Range 500mg. £1000 Readability ‘on0ima ‘Sample quantity | 19 max in gross weight ‘Atmosphere Reaction gas, purge gas and cleaning gas can 'bo supplied. Gas can be exhausted for gas replacement Dimensions W867 D650 1453 (am) ight 5g {installation requirements Power supply: DIG-60: AG100,120V 1300VA So/60Hz DTG-60H:AC100.120V 1S00VA Save0Hiz ‘Ambient temperature: | 5 to 40°C (No condensation) ‘Atmosphere gas control: | A gas cylinder, pressure governor, piping components and Shimadzu atmosphere gas contrller FC-60A are required, System construction: _| Shirsadzu Thermal Analysis Data Processing System TA-GOWS, commercially-avallable personal ‘computer (Windows"85/98/Me/NT), perioheral equipment (e.g. printer) and software (OS and driver) are required, ‘Autosampler: “The Autosampler can be mounted when ordering the DTG-60/60H or afterward General environment: | Do not install this equipment ina dusty place or in a place where it may be directly exposed to sunlight, wind from a coaling/heating appliance, vibration or large temperature fluctuations. * We reserve the right to modify he appearance and specifications of our products without a prior notice. EE) SHIMADZU SHOT CORPORATION. ran! Meating Dvn stamons 90 arast. couénco rok SHAOZY SEITE NSTRUMENT, so (ONG Won) UTED 708 Aennd Onn, Cabs, and 206, US Sura 18 Oca Gea Tem Sh TH Haman HONG HENS stozy OETSCHLAND Gab ene tes svamoas isa ACE) PTE LT sons SomITACNSTRUMENTS (OCEANA) FY LO URL http:liwww.shimadzu.com

You might also like