API 650 Tank Annex L - Data Sheet
API 650 Tank Annex L - Data Sheet
API
API Std 650 Storage Tank Data Data Sheet Status:
Page 1 of 8
Sheet
* For boxes marked with *, if blank, Mfr. shall determine and submit as per Annex L. For all lines, see Annex L for line-by-line instructions.
Design Internal Pressure Design External Pressure Internal Pressure Combination Factor
External Pressure Combination ■Facto■r Maximum Fill Rate Maximum Emptying Rate Flotation Considerations? Yes No Flot.
Suppl. Spec:* Applied Supplemental Load Spec.
8. Seismic Design? Yes ■ ■ No Annex E ■ Alternate Seismic Criteria Seismic Use Group _ MBE Site Class Vertical Seismic
Basis of Lateral Acceleration (Select one): ■ Mapped Seismic Parameters? S5 S1 So ; ■ Site-Specific Procedures? MCE
■
9.
Freeboard Required for SUG I Design Roof Tie Rods@ Outer Ring?* Yes
Wind Velocity for non-U.S. sites, 50-yr wind speed (3-sec Gust)*
■■ No
Top Wind Girder Style* Dimensions* Use Top Wind Girder as Walkway? Yes I No I Intermediate Wind Girders?*
Yes ■■ No Intermediate Wind Girder Style* Dimensions* Check Buckling in Corroded Cond.? Yes ■■ No
Centerline-Stacked? Yes ■ ■ No
Plate Widths (Shell course heights) and Thicknesses* Numbers below Indicate Course Number.
Flush-Stacked? Yes ■ ■ ■ No Inside Outside ■
1. 2. 3. 4. 5.
6. 7. 8. 9. 10.
11. 12. 13. 14. 15.
Joint Efficiency* % Shell-to-Bottom Weld Type* Shell-to-Bottom Weld Exam Mthd* Exceptions to Seal-welded Attachments (see
Section 5.1.3.7):
API
API Std 650 Storage Tank Data
Sheet
11. Open-Top and Fixed Roofs: (See Sheet 6 for Floating Roofs) Open Top? * Yes ■ ■ No
Fixed Roof Type* Roof Support Columns*: Pipe ■ Or Structural Shape ■
Cone Slope* . Dome or Umbrella Radius* Weld Joints*
(Lap, Butt, Other)
Seal Weld Underside of Lap-Joints? Yes ■ ■; No Seal Weld Underside of \Mnd Girder Joints? Yes ■ ■ No Gas-tight? Yes ■ ■ No Joint Effi
%
Thickness*
App. Suppl. Load Spec.* Column Lateral Load Normal Venting Devices*
In. Snow Load *
Em
Venting Devices*
Free Vents in Areas Where Snow and Ice May Block Vent* ■ ■; ■■
For Non-Frangible Roofs: Seal Weld Roof Plates to Top Angle on the Inside? Yes No Weld rafters to Roof Plates Yes No
Foundation Design Loads: Base Shear Force: Wind* Seismic* Overturning Moment: Wind* Seismic* \ Ring Forces: Weight
Roof New* Corroded* Roof Live Load* Internal Pressure* _ Partial Vacuum* Wind* Seismic
Hydrates! Exemption design per 7.3.6, Item 2) a)
Bottom Forces: Floor Wt. New* Corroded* Product Wt.* Water Wt.* Internal Pressure*
Partial Vacuum* Other Foundation Loads* Min. Projection of Fdn. Above Grade:
14. Exemption from hydrates!? Yes ■ ■No Responsibility for Heating Water, if Required: Purchaser ■ Manufacturer ■
■Hydro-Test Fill Height* Settlement Measurements Required? Yes ■ ■ No Extended Duration of Hydro-Test:
Predicted Settlement Profile is Attached
■Application of coating on weld joints shall be performed after hydrostatic testing is performed, unless otherwise specified to be
before hydrostatic testing is performed. ■ ■
Responsibility for Setting Water Quality: Purchaser Manufacturer Supplemental Test Water Quality Spec. ■ ■
Test Water Source & Disposal Tie-In Locations Hydro-Test Annex J Tank? Yes No
Post-Pressure-Test Activities Required of the Manufacturer: Broom Clean ■ Potable Water Rinse ■ Dry Interior ■ Other ■
15. Inspection by in Shop; in Field
Supplemental NOE Responsibility Supplemental NOE Spec. Positive Material Id
■ Top of Tank, H ■ 1
/3 H, 2/3 H and H ■ Top of Each Shell Course ■ Other:
**See Data Sheet Instructions for the Maximum Allowable Additional Radial Tolerance.
API
API Std 650 Storage Tank Data
Sheet
Page 3 of 8
16. Coatings:
Internal Coatings by: Per Spec.*
(Not Req'd., Others, Tank Mfg.)
External Coating by: Per Spec.*
(Not Req'd., Others, Tank Mfg.)
Under-Bottom Coating by: Per Spec.*
(Not Req'd., Others, Tank Mfg.)
20. Tank Measurement System: Required? ■ ■ Yes No Type: Float and tape gauge
Servo gauge: Hydrostatic gauge: MTG multifunction gauge: Other gauge: Remote Capability Required? Yes
■ ■ No
By:* Per Spec.*
21. Weight of Tank: Full of Water* Empty* Shipping* Brace/Lift Spec.*
22. References*:
API Std 650, Annex L
23. Remarks*:
Approvals: Revisions: Title:
By: Ck'd: Date:
Drawing No.: Sheet of
API
API Std 650 Storage Tank
Data Sheet Page 4 of 8
Component Head Type* Bolt or Anchor Material* Nut Material* Thread Series* C.A.
Flange Bolting ++
Structural Bolting ++
Anchor Bolts ++
Size, NPS, or Neck Sch or Full Pen. Flange Gasket Bearing Gasket Mat'I.
Dia. (In.) Wall Thick. Reinf. Plate On Open. Flange Class or Surf. Dimen. and Gasket Thick. and Descript.
Dimensions (Y/N) Type Thick. Finish and Dimen.
Mark Service
Approvals: Revisions: Title:
By: Ck'd:
I Date:
Drawing No.: Sheet of
API
API Std 650 Storage Tank
Data Sheet
Page 5 of 8
* If box is blank, Manufacturer shall determine and submit as per Annex L.
OTHER TANK APPURTENANCES
29. Various Other Items: Welded Flush-Type: Shell Connection ■ Cleanout Fitting ■ Waive Application of Annex P? Yes ■ ■ No
Miscellany #1 Miscellany #2
Miscellany #3 Miscellany #4
Miscellany #5 Miscellany #6
Service or
Mark Quantity Description Size Orientation Height from Datum Material Remarks
Approvals: Revisions: Title:
By: Ck'd: Date:
Drawing No.: Sheet of
WELDED TANKS FOR OIL STORAGE L-25
API
API Std 650 Storage Tank Data
Sheet
Page 6 of 8
• If box is blank, Manufacturer shall determine and submit as per Annex L.
FLOATING ROOF DATA
30. Floating Roof Selection
Design Basis: Annex C I Or Annex H I
Type of Roof: (External or Internal): Single Deck Pontoon* I Double Deck* I
(Internal Only): Tubular Pontoon* I Metallic Sandwich Panel* I
Other I Supplemental Spec.:
31. Seals
Primary Seal: Shoe I Envelope I I Other I Supplemental Spec:
Wiper/Compression Plate
Shoe Mechanism: Mfg. Std. I Other I Electrically Isolate Mechanism from Shoes? Yes I No I Wax Scrapers
Required? Yes I No I Minimum Shoe Thickness* Carbon Steel Shoes to be Galvanized? Yes I No I
Secondary Seal: Shoe I Envelope I Wiper I None I Other I Supplemental Spec:
Data for All Floating Roofs:
Overflow Openings in Shell Acceptable? Yes I No I Shell Extension? Yes I No I
Roof-Drain Check Valves Required? Yes I No I Roof-Drain Isolation Valves Required? Yes I No I
Freeze Protection for Roof Drains Required? No I Yes I Supplemental Requirements:
Roof-Drain Piping to External Nozzles: Mfg. Std. I Armored Flexible Pipe I Swivels in Rigid Pipe I Other I
Electrical Bonding: Shunts: Yesl No I Cables: Yes I No I Supplemental Spec. Qty of Non-Guide-Pole Gauge Wells Required
Qty of Sample Hatches Required
Guide Pole for Gauging? Yes I No I Slots in Guide Pole? Yes I No I Datum Plates? Yes I No I Striking Plates? Yes I No I
Guide Pole Emissions-Limiting Devices: Sliding Cover Pole Wiper I Pole Sleeve FloatI Float Wiper I Pole Cap I I I
Qty. of Roof Manholes* Alternative High-Roof Clearance Above Bottom: _ Alternative Low-roof Clearance Above the Highest Obstruction and the Floating Roof: _
Removable Leg Storage Racks? Yes I No I ; Leg Sleeves I or Fixed Low Legs I
33. Additional Data for External Floating Roofs:
Weather Shield? Yes I No I Suppl. Spec. Rolling Ladder Req'd? Yes No I I
Field Adjustable Legs? Yes I No I
Design Rainfall Intensity ln./Hr. (mm/hr) Based on a Minute Duration Associated with the Storm
Design Accumulated 24-Hour Rainfall In. (mm) Based on the Storm
Distortion and Stability Determinations Required? Yes I No I Supplemental Specification Landed Live Load*
Design Rainfall Intensity ln./Hr. (mm/hr) Based on a Minute Duration Associated with the Storm
Design Accumulated 24-Hour Rainfall In. (mm) Based on the Storm
Distortion and Stability Determinations Required? Yes I No I Supplemental Specification Landed Live Load*
API
API Std 650 Storage Tank Data
Sheet Page
Two-Position Legs? Yes ■■ No Cable-Supported Roof? Yes ■ ■ No Fixed-Roof Inspection Hatches Required?: Yes ■■ No Internal Roof Drain Required?
■ ■
Corrosion Gauge Required? Yes No ■ ■;
Fixed Ladder Required?: Yes
Supplemental Specification
No Type of Roof Vent:• Modified Minimum Point Load? Yes ■ ■ No
■
Mfr. to Leak Test•_% of Compartments in Assembly Yard ■ ■ in Erected Position Unknown; see separate contract terms Roof Erector's Flotation Test: ■
w/ tank hydro at
Flotation Test Items provided by Purchaser (see H.6.7): None■ ■ List Attached Responsible Party for Inspecting Roof during Initial Fill: Purchaser ■ ■ Other
----
API
API Std 650 Storage Tank
Data Sheet
Notes:
ess
ty: Maximum*
■ ■ No Suppl.
■
erations? Yes No Flot.
nd Girders?*
No ■
e ■ Plate Stacking Criteria*
Date:
of
ANMUGAM Not for Resale, 06/23/2020 07:23:41 MDT
L-21
Page 2 of 8
g Devices* Emergency
es Yes No
cturer ■
ro-Test:
fied to be
■ ■
s No
Other ■
in Field
Positive Material Identification?
ss? Yes No
e:
Ck'd: Date:
al.lJirlcgVr-tW\NMUGAMSheet of
- -
Page 3 of 8
Date:
Sheet of
L-23
Page 4 of 8
C.A.
+
+
ace I.
C.A.
++
++
++
Proj. to FF or CL
or from Datum
Lines
I Date:
Page 5 of 8
Remarks
Date:
t of
L-25
Page 6 of 8
es I No I Wax Scrapers
e Floating Roof: _
o I
oad*
oad*
Page 7 of 8
rain Required?
on Test: ■
w/ tank hydro at
r ■ ■ Other
C.A./Coating•
I
L-27
Page 8 of 8
Ck'd:
I Date:
No.: Sheet of