F4-F5 Visual 008-02 Filter IOM
F4-F5 Visual 008-02 Filter IOM
Top Cap
Outlet
Inlet Moisture Indicator
O-ring (Optional)
1 2 3 4 5
Determine how quickly condensation Isolate the filter dryer. If the filter Drain the filter dryer to vent any Unscrew the body from the Unscrew the filter cartridge from
Body or free liquids accumulate in the dryer is not equipped with the pressure remaining in the body. top cap. the top cap.
filter dryer by frequently draining optional bypass, close the outlet
Filter Cartridge the Filter dryer. valve on the pneumatic supply
source and shut down any
instrumentation connectedto the
filter dryer. If the filter dryer is
equipped with the optional bypass,
open the bypass valve, and then
close the inlet and outlet valves on
Liquid Collection the filter dryer.
Area
Drain